{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T10:14:50Z","timestamp":1794305690840,"version":"4.9.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Semi-implantable bone conduction implants (BCI) and active middle ear implants (AMEI) for patients with sensorineural, conductive or mixed hearing loss commonly use an amplitude modulation technology to transmit power and sound signals from an external audio processor to the implant. In patients, the distance dependence of the signal amplitude is of minor importance as the skin thickness is constant and only varies between 3\u20137\u2009mm. In this range, critical coupling transmission technique sufficiently reduces the variability in amplitude, but fails to provide well-defined amplitudes in many research and clinical applications such as intraoperative integrity tests where the distance range is exceeded by using sterile covers. Here we used the BCI Bonebridge (BB, Med-El, Austria) as an example to develop and demonstrate a system that synthesizes the transmission signal, determines the distance between the transmitter and the receiver implant coil and compensates transmission losses. When compared to an external audio processor (AP304) on an artificial mastoid, our system mainly decreased amplitude variability from over 11\u2009dB to less than 3\u2009dB for audio frequencies (0.1\u201310\u2009kHz) at distances up to 15\u2009mm, making it adequate for intraoperative and audiometric tests.<\/jats:p>","DOI":"10.1038\/s41598-020-58512-7","type":"journal-article","created":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T11:02:47Z","timestamp":1580814167000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["A Precision Driver Device for Intraoperative Stimulation of a Bone Conduction Implant"],"prefix":"10.1038","volume":"10","author":[{"given":"Mohammad","family":"Ghoncheh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Lenarz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannes","family":"Maier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,2,4]]},"reference":[{"key":"58512_CR1","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.heares.2013.02.003","volume":"301","author":"AM Huber","year":"2013","unstructured":"Huber, A. M. et al. The Bonebridge: Preclinical evaluation of a new transcutaneously-activated bone anchored hearing device. Hear. Res. 301, 93\u201399 (2013).","journal-title":"Hear. Res."},{"issue":"10","key":"58512_CR2","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.3109\/00016489.2013.799293","volume":"133","author":"Maurizio Barbara","year":"2013","unstructured":"Barbara, M., Perotti, M., Gioia, B., Volpini, L. & Monini, S. Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a fi rst series of patients with mixed hearing loss. 1\u20137. https:\/\/doi.org\/10.3109\/00016489.2013.799293 (2013).","journal-title":"Acta Oto-Laryngologica"},{"key":"58512_CR3","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1097\/MAO.0b013e31828bb541","volume":"34","author":"G Sprinzl","year":"2013","unstructured":"Sprinzl, G. et al. First European multicenter results with a new transcutaneous bone conduction hearing implant system: Short-term safety and efficacy. Otol. Neurotol. 34, 1076\u20131083 (2013).","journal-title":"Otol. Neurotol."},{"key":"58512_CR4","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1109\/TBME.1984.325404","volume":"31","author":"ES Hochmair","year":"1984","unstructured":"Hochmair, E. S. System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission. IEEE Trans. Biomed. Eng. BME 31, 177\u2013186 (1984).","journal-title":"IEEE Trans. Biomed. Eng. BME"},{"key":"58512_CR5","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1109\/10.55682","volume":"37","author":"CM Zierhofer","year":"1990","unstructured":"Zierhofer, C. M. & Hochmair, E. S. High-efficiency coupling-insensitive transcutaneous power and data transmission via an inductive link. IEEE Trans. Biomed. Eng. 37, 716\u2013722 (1990).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"58512_CR6","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1007\/BF02457921","volume":"15","author":"WH Ko","year":"1977","unstructured":"Ko, W. H., Liang, S. P. & Fung, C. D. F. Design of radio-frequency powered coils for implant instruments. Med. Biol. Eng. Comput. 15, 634\u2013640 (1977).","journal-title":"Med. Biol. Eng. Comput."},{"key":"58512_CR7","unstructured":"Terman, F. Circuit theory, 1st edition. Radio engineer\u2019s handbook. 3, 135\u2013172 (McGRAW-HILL BOOk COMPANY Inc (1943)."},{"key":"58512_CR8","unstructured":"Clarke, K. & Hess, D. Communication Circuits: Analysis and Design. In 31\u201338, 347\u2013400 (Addison-Welsley Publishing Company (1971)."},{"key":"58512_CR9","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1088\/0143-0815\/8\/4A\/002","volume":"8","author":"R Pethig","year":"1987","unstructured":"Pethig, R. Dielectric Properties of Body Tissues. Clin. Phys. Physiol. Meas. 8, 5\u201312 (1987).","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"58512_CR10","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.heares.2015.12.019","volume":"340","author":"M Ghoncheh","year":"2016","unstructured":"Ghoncheh, M., Lilli, G., Lenarz, T. & Maier, H. Outer ear canal sound pressure and bone vibration measurement in SSD and CHL patients using a transcutaneous bone conduction instrument. Hear. Res. 340, 161\u2013168 (2016).","journal-title":"Hear. Res."},{"key":"58512_CR11","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1097\/MAO.0000000000000351","volume":"35","author":"J Schnabl","year":"2014","unstructured":"Schnabl, J. et al. Intraoperative Measurement for a New Transcutaneous Bone Conduction Hearing Implant. Otol. Neurotol. 35, 1242\u20131247 (2014).","journal-title":"Otol. Neurotol."},{"key":"58512_CR12","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1097\/AUD.0000000000000572","volume":"39","author":"W Hodgetts","year":"2018","unstructured":"Hodgetts, W., Scott, D., Maas, P. & Westover, L. Development of a Novel Bone Conduction Verification Tool Using a Surface Microphone. Ear Hear. 39, 1157\u20131164 (2018).","journal-title":"Ear Hear."},{"issue":"Suppl 1","key":"58512_CR13","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1515\/bmte.2002.47.s1b.726","volume":"47","author":"M Winter","year":"2002","unstructured":"Winter, M., Weber, B. P. & Lenarz, T. Measurement method for the assessment of transmission properties of implantable hearing aids. Biomed. Tech. (Berl). 47(Suppl 1), 726\u2013727 (2002).","journal-title":"Biomed. Tech. (Berl)."},{"key":"58512_CR14","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1097\/MAO.0b013e3181f0c612","volume":"31","author":"VJO Verhaegen","year":"2010","unstructured":"Verhaegen, V. J. O. et al. Intraoperative auditory steady state response measurements during vibrant soundbridge middle ear implantation in patients with mixed hearing loss: Preliminary results. Otol. Neurotol. 31, 1365\u20131368 (2010).","journal-title":"Otol. Neurotol."},{"key":"58512_CR15","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1097\/MAO.0b013e3181fcf167","volume":"32","author":"A Radeloff","year":"2011","unstructured":"Radeloff, A. et al. Intraoperative monitoring of active middle ear implant function in patients with normal and pathologic middle ears. Otol. Neurotol. 32, 104\u20137 (2011).","journal-title":"Otol. Neurotol."},{"key":"58512_CR16","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1177\/0194599811430808","volume":"146","author":"V Colletti","year":"2012","unstructured":"Colletti, V., Mandal\u00e0, M. & Colletti, L. Electrocochleography in round window vibrant soundbridge implantation. Otolaryngol. - Head Neck Surg. (United States) 146, 633\u2013640 (2012).","journal-title":"Otolaryngol. - Head Neck Surg. (United States)"},{"key":"58512_CR17","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1080\/14992027.2017.1314558","volume":"56","author":"M Cebulla","year":"2017","unstructured":"Cebulla, M., Geiger, U., Hagen, R. & Radeloff, A. Device optimised chirp stimulus for ABR measurements with an active middle ear implant. Int. J. Audiol. 56, 607\u2013611 (2017).","journal-title":"Int. J. Audiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58512-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58512-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58512-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,2]],"date-time":"2023-01-02T14:50:18Z","timestamp":1672671018000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58512-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,4]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["58512"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-58512-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,4]]},"assertion":[{"value":"14 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This work is part of the doctoral thesis of MG and was supported by the DFG Cluster of Excellence EXC 1077\/1 \u201cHearing4all\u201d. MG and HM received travel support to conferences by MED-El and TL declares no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1797"}}