{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T08:06:33Z","timestamp":1771488393669,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T00:00:00Z","timestamp":1582588800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T00:00:00Z","timestamp":1582588800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Intrathecal administration of nusinersen in adult spinal muscular atrophy (SMA) patients with scoliosis and spondylodesis requires image guidance, which is preferably achieved with multi-detector computed tomography (MDCT). As long-term treatment is necessary and patients are young, radiation doses should be reduced to a minimum whilst a sufficient image quality for precise interventional performance should be kept. We compared 44 MDCT standard-dose scans (133.0\u2013200.0\u2009mA) with a hybrid iterative reconstruction (iDose4) to 20 low-dose scans (20.0\u201367.0\u2009mA) with iterative model reconstruction (IMR), which were performed for procedure planning of intrathecal nusinersen administration in 13 adult patients with SMA and complex spinal conditions. Qualitative image evaluation, including confidence for intervention planning, was performed by two neuroradiologists for standard- and low-dose scans. All 64 MDCT-guided intrathecal administrations of nusinersen were successful. The dose length product (DLP) was significantly lower when using low-dose scanning with IMR (median DLP of standard-dose scans: 92.0 mGy\u2022cm vs. low-dose scans: 34.5 mGy\u2022cm; p\u2009&lt;\u20090.0001). Image quality was significantly reduced for low-dose compared to standard-dose scanning. However, bone\/soft tissue contrast and confidence for intervention planning were not significantly impaired in low-dose MDCT according to both readers, showing good inter-reader agreement. Thus, we hereby demonstrate a low-dose MDCT protocol combined with advanced image reconstruction for scanning during procedure planning as a viable option for image guidance in intrathecal nusinersen treatment of adult SMA patients with complex spinal conditions.<\/jats:p>","DOI":"10.1038\/s41598-020-60240-x","type":"journal-article","created":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T11:03:07Z","timestamp":1582628587000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Radiation dose reduction for CT-guided intrathecal nusinersen administration in adult patients with spinal muscular atrophy"],"prefix":"10.1038","volume":"10","author":[{"given":"Isabell","family":"Cordts","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcus","family":"Deschauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Lingor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Egon","family":"Burian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Baum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claus","family":"Zimmer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Maegerlein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nico","family":"Sollmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,2,25]]},"reference":[{"key":"60240_CR1","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/0092-8674(95)90460-3","volume":"80","author":"S Lefebvre","year":"1995","unstructured":"Lefebvre, S. et al. Identification and characterization of a spinal muscular atrophy-determining gene. Cell 80, 155\u2013165 (1995).","journal-title":"Cell"},{"key":"60240_CR2","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s00415-018-9124-0","volume":"266","author":"CD Wurster","year":"2019","unstructured":"Wurster, C. D. et al. Intrathecal administration of nusinersen in adolescent and adult SMA type 2 and 3 patients. Journal of neurology 266, 183\u2013194 (2019).","journal-title":"Journal of neurology"},{"key":"60240_CR3","doi-asserted-by":"publisher","first-page":"175628641880324","DOI":"10.1177\/1756286418803246","volume":"11","author":"B Stolte","year":"2018","unstructured":"Stolte, B. et al. Feasibility and safety of intrathecal treatment with nusinersen in adult patients with spinal muscular atrophy. Therapeutic advances in neurological disorders 11, 1756286418803246 (2018).","journal-title":"Therapeutic advances in neurological disorders"},{"key":"60240_CR4","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner, D. J. & Hall, E. J. Computed tomography\u2013an increasing source of radiation exposure. The New England journal of medicine 357, 2277\u20132284, https:\/\/doi.org\/10.1056\/NEJMra072149 (2007).","journal-title":"The New England journal of medicine"},{"key":"60240_CR5","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00256-009-0819-2","volume":"39","author":"PJ Richards","year":"2010","unstructured":"Richards, P. J., George, J. & Diagnostic, C. T. radiation and cancer induction. Skeletal Radiol 39, 421\u2013424, https:\/\/doi.org\/10.1007\/s00256-009-0819-2 (2010).","journal-title":"Skeletal Radiol"},{"key":"60240_CR6","doi-asserted-by":"crossref","unstructured":"Oldenburg, D. et al. Radiation exposure of image-guided intrathecal administration of nusinersen to adult patients with spinal muscular atrophy. Neuroradiology, 1-10 (2019).","DOI":"10.1007\/s00234-019-02189-x"},{"key":"60240_CR7","doi-asserted-by":"crossref","unstructured":"Cordts, I. et al. Intrathecal nusinersen administration in adult spinal muscular atrophy patients with complex spinal anatomy. Therapeutic advances in neurological disorders in press (2019).","DOI":"10.1177\/1756286419887616"},{"issue":"Suppl 2","key":"60240_CR8","doi-asserted-by":"publisher","first-page":"S39","DOI":"10.1097\/HP.0b013e3181d18d63","volume":"98","author":"JJ Bevelacqua","year":"2010","unstructured":"Bevelacqua, J. J. Practical and effective ALARA. Health Phys. 98(Suppl 2), S39\u201347, https:\/\/doi.org\/10.1097\/HP.0b013e3181d18d63 (2010).","journal-title":"Health Phys."},{"key":"60240_CR9","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1259\/bjr\/88081058","volume":"77","author":"KN Prasad","year":"2004","unstructured":"Prasad, K. N., Cole, W. C. & Haase, G. M. Radiation protection in humans: extending the concept of as low as reasonably achievable (ALARA) from dose to biological damage. Br. J. Radiol. 77, 97\u201399, https:\/\/doi.org\/10.1259\/bjr\/88081058 (2004).","journal-title":"Br. J. Radiol."},{"key":"60240_CR10","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1007\/s00330-012-2765-y","volume":"23","author":"MJ Willemink","year":"2013","unstructured":"Willemink, M. J. et al. Iterative reconstruction techniques for computed tomography Part 1: technical principles. European radiology 23, 1623\u20131631, https:\/\/doi.org\/10.1007\/s00330-012-2765-y (2013).","journal-title":"European radiology"},{"key":"60240_CR11","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1007\/s00330-012-2764-z","volume":"23","author":"MJ Willemink","year":"2013","unstructured":"Willemink, M. J. et al. Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality. European radiology 23, 1632\u20131642, https:\/\/doi.org\/10.1007\/s00330-012-2764-z (2013).","journal-title":"European radiology"},{"key":"60240_CR12","doi-asserted-by":"publisher","first-page":"2185","DOI":"10.1007\/s00330-018-5810-7","volume":"29","author":"MJ Willemink","year":"2019","unstructured":"Willemink, M. J. & Noel, P. B. The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. European radiology 29, 2185\u20132195, https:\/\/doi.org\/10.1007\/s00330-018-5810-7 (2019).","journal-title":"European radiology"},{"key":"60240_CR13","doi-asserted-by":"crossref","unstructured":"Cordts, I. et al. Intrathecal nusinersen administration in adult spinal muscular atrophy patients with complex spinal anatomy. Therapeutic advances in neurological disorders (2019).","DOI":"10.1177\/1756286419887616"},{"key":"60240_CR14","doi-asserted-by":"publisher","unstructured":"Sollmann, N. et al. Systematic Evaluation of Low-dose MDCT for Planning Purposes of Lumbosacral Periradicular Infiltrations. Clin Neuroradiol, https:\/\/doi.org\/10.1007\/s00062-019-00844-7 (2019).","DOI":"10.1007\/s00062-019-00844-7"},{"key":"60240_CR15","doi-asserted-by":"crossref","unstructured":"Kizina, K. et al. Clinical implication of dosimetry of computed tomography-and fluoroscopy-guided intrathecal therapy with nusinersen in adult patients with spinal muscular atrophy. Frontiers in Neurology 10 (2019).","DOI":"10.3389\/fneur.2019.01166"},{"key":"60240_CR16","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","volume":"380","author":"MS Pearce","year":"2012","unstructured":"Pearce, M. S. et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. The Lancet 380, 499\u2013505 (2012).","journal-title":"The Lancet"},{"key":"60240_CR17","doi-asserted-by":"publisher","DOI":"10.1186\/s12958-018-0432-0","volume":"16","author":"R Marci","year":"2018","unstructured":"Marci, R. et al. Radiations and female fertility. Reproductive Biology and Endocrinology 16, 112 (2018).","journal-title":"Reproductive Biology and Endocrinology"},{"key":"60240_CR18","doi-asserted-by":"crossref","unstructured":"Ahmad, G. & Agarwal, A. In Male Infertility 185\u2013196 (Springer, 2017).","DOI":"10.1007\/978-81-322-3604-7_12"},{"key":"60240_CR19","doi-asserted-by":"publisher","first-page":"e620","DOI":"10.1212\/WNL.0000000000006006","volume":"91","author":"A Veerapandiyan","year":"2018","unstructured":"Veerapandiyan, A. et al. Cervical puncture to deliver nusinersen in patients with spinal muscular atrophy. Neurology 91, e620\u2013e624 (2018).","journal-title":"Neurology"},{"key":"60240_CR20","doi-asserted-by":"crossref","first-page":"175628641877693","DOI":"10.1177\/1756286418776932","volume":"11","author":"CD Wurster","year":"2018","unstructured":"Wurster, C. D. & Ludolph, A. C. Antisense oligonucleotides in neurological disorders. Therapeutic Advances in Neurological Disorders 11, 1756286418776932 (2018).","journal-title":"Therapeutic Advances in Neurological Disorders"},{"key":"60240_CR21","doi-asserted-by":"publisher","first-page":"15","DOI":"10.2214\/AJR.14.12622","volume":"204","author":"H Kroll","year":"2015","unstructured":"Kroll, H. et al. Trends in lumbar puncture over 2 decades: a dramatic shift to radiology. American Journal of Roentgenology 204, 15\u201319 (2015).","journal-title":"American Journal of Roentgenology"},{"key":"60240_CR22","doi-asserted-by":"publisher","first-page":"1276","DOI":"10.3174\/ajnr.A5128","volume":"38","author":"P Hudgins","year":"2017","unstructured":"Hudgins, P., Fountain, A., Chapman, P. & Shah, L. Difficult lumbar puncture: Pitfalls and tips from the trenches. American Journal of Neuroradiology 38, 1276\u20131283 (2017).","journal-title":"American Journal of Neuroradiology"},{"key":"60240_CR23","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1136\/neurintsurg-2013-010745","volume":"6","author":"AD Brook","year":"2014","unstructured":"Brook, A. D., Burns, J., Dauer, E., Schoendfeld, A. H. & Miller, T. S. Comparison of CT and fluoroscopic guidance for lumbar puncture in an obese population with prior failed unguided attempt. Journal of neurointerventional surgery 6, 323\u2013327 (2014).","journal-title":"Journal of neurointerventional surgery"},{"key":"60240_CR24","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1177\/159101990901500109","volume":"15","author":"JM Debnam","year":"2009","unstructured":"Debnam, J. M. et al. Multidetector CT-guided lumbar puncture in patients with cancer. Interventional Neuroradiology 15, 61\u201366 (2009).","journal-title":"Interventional Neuroradiology"},{"key":"60240_CR25","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1055\/s-0033-1350368","volume":"185","author":"B Rogits","year":"2013","unstructured":"Rogits, B. et al. Prospective Evaluation of the radiologist\u2019s hand dose in CT-guided interventions. Rofo 185, 1081\u20131088, https:\/\/doi.org\/10.1055\/s-0033-1350368 (2013).","journal-title":"Rofo"},{"key":"60240_CR26","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1148\/radiol.2018181224","volume":"290","author":"TJ Dietrich","year":"2019","unstructured":"Dietrich, T. J. et al. Fluoroscopy-guided versus CT-guided Lumbar Steroid Injections: Comparison of Radiation Exposure and Outcomes. Radiology 290, 752\u2013759, https:\/\/doi.org\/10.1148\/radiol.2018181224 (2019).","journal-title":"Radiology"},{"key":"60240_CR27","doi-asserted-by":"publisher","first-page":"5261","DOI":"10.1007\/s00330-017-4904-y","volume":"27","author":"K Mei","year":"2017","unstructured":"Mei, K. et al. Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling? European radiology 27, 5261\u20135271, https:\/\/doi.org\/10.1007\/s00330-017-4904-y (2017).","journal-title":"European radiology"},{"key":"60240_CR28","doi-asserted-by":"publisher","first-page":"3606","DOI":"10.1007\/s00330-019-06090-2","volume":"29","author":"N Sollmann","year":"2019","unstructured":"Sollmann, N. et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. European radiology 29, 3606\u20133616, https:\/\/doi.org\/10.1007\/s00330-019-06090-2 (2019).","journal-title":"European radiology"},{"key":"60240_CR29","unstructured":"Chen, B. et al. In The Fifth International Conference on Image Formation in X-Ray Computed Tomography, Salt Lake City. 52\u201355."},{"key":"60240_CR30","unstructured":"Koesters, T., Knoll, F., Sodickson, A., Sodickson, D. K. & Otazo, R. In SPIE Medical Imaging. 7 (SPIE)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-60240-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-60240-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-60240-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T07:21:13Z","timestamp":1670311273000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-60240-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,25]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["60240"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-60240-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,25]]},"assertion":[{"value":"14 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"I.C. received travel reimbursement and honoraria as speaker from Biogen. M.D. received travel reimbursement from Biogen. P.L. received sponsoring for symposium organization from Biogen as well as personal fees from Desitin, BIAL, AbbVie, and Novartis outside the submitted work. E.B. reports no conflict of interest. T.B. reports no conflict of interest. C.Z. reports no conflict of interest. C.M. reports no conflict of interest. N.S. reports no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3406"}}