{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T08:10:48Z","timestamp":1770279048408,"version":"3.49.0"},"reference-count":71,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T00:00:00Z","timestamp":1585094400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T00:00:00Z","timestamp":1585094400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Abdominal aortic aneurysm (AAA) is an irreversible bulge in the artery with higher prevalence among the elderlies. Increase of the aneurysm diameter by time is a fatal phenomenon which will lead to its sidewall rupture. Invasive surgical treatments are vital in preventing from AAA development. These approaches however have considerable side effects. Targeted drug delivery using microbubbles (MBs) has been recently employed to suppress the AAA growth. The present study is aimed to investigate the surface adhesion of different types of drug-containing MBs to the inner wall of AAA through ligand-receptor binding, using fluid-structure interaction (FSI) simulation by using a patient CT-scan images of the vascular system. The effect of blood flow through AAA on MBs delivery to the intended surface was also addressed. For this purpose, the adherence of four types of MBs with three different diameters to the inner surface wall of AAA was studied in a patient with 40-mm diameter aneurysm. The effects of the blood mechanical properties on the hematocrit (Hct) percentage of patients suffering from anemia and diabetes were studied. Moreover, the impact of variations in the artery inlet velocity on blood flow was addressed. Simulation results demonstrated the dependency of the surface density of MBs (SDM) adhered on the AAA lumen to the size and the type of MBs. It was observed that the amount of SDM due to adhesion on the AAA lumen for one of the commercially-approved MBs (Optison) with a diameter of 4.5 \u03bcm was higher than the other MBs. Furthermore, we have shown that the targeted drug delivery to the AAA lumen is more favorable in healthy individuals (45% Hct) compared to the patients with diabetes and anemia. Also, it was found that the targeted drug delivery method using MBs on the patients having AAA with complicated aneurysm shape and negative inlet blood flow velocity can be severely affected.<\/jats:p>","DOI":"10.1038\/s41598-020-62410-3","type":"journal-article","created":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T11:03:32Z","timestamp":1585134212000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["Targeted Drug Delivery of Microbubble to Arrest Abdominal Aortic Aneurysm Development: A Simulation Study Towards Optimized Microbubble Design"],"prefix":"10.1038","volume":"10","author":[{"given":"Amir","family":"Shamloo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sina","family":"Ebrahimi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Amani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Famida","family":"Fallah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,3,25]]},"reference":[{"key":"62410_CR1","doi-asserted-by":"crossref","unstructured":"Lederle, F. A. et al. Prevalence and associations of abdominal aortic aneurysm detected through screening. Ann. Intern. Med. (1997).","DOI":"10.7326\/0003-4819-126-6-199703150-00004"},{"key":"62410_CR2","unstructured":"Chaikof, E. L. et al. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J. Vasc. Surg. (2018)."},{"key":"62410_CR3","unstructured":"Moll, F. L. et al. Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur. J. Vasc. Endovasc. Surg. (2011)."},{"key":"62410_CR4","doi-asserted-by":"crossref","unstructured":"Kumar, Y. et al Abdominal aortic aneurysm: pictorial review of common appearances and complications. Ann. Transl. Med. (2017).","DOI":"10.21037\/atm.2017.04.32"},{"key":"62410_CR5","doi-asserted-by":"crossref","unstructured":"Powell, J. T. et al. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years. British Journal of Surgery. (2017).","DOI":"10.1016\/j.jvs.2017.03.403"},{"key":"62410_CR6","doi-asserted-by":"crossref","unstructured":"Michel, M., Becquemin, J.-P., Marzelle, J., Quelen, C. & Durand-Zaleski, I. Editor\u2019s Choice \u2013 A Study of the Cost-effectiveness of Fenestrated\/branched EVAR Compared with Open Surgery for Patients with Complex Aortic Aneurysms at 2 Years, Eur. J. Vasc. Endovasc. Surg., vol. 56, no. 1, pp. 15\u201321, (Jul. 2018).","DOI":"10.1016\/j.ejvs.2017.12.008"},{"issue":"4","key":"62410_CR7","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1016\/j.ymthe.2018.02.010","volume":"26","author":"X Wang","year":"2018","unstructured":"Wang, X. et al. Dual-Targeted Theranostic Delivery of miRs Arrests Abdominal Aortic Aneurysm Development. Mol. Ther. 26(4), 1056\u20131065 (2018).","journal-title":"Mol. Ther."},{"key":"62410_CR8","doi-asserted-by":"crossref","unstructured":"Wang, Y. et al Inhibitory Effects of Cycloastragenol on Abdominal Aortic Aneurysm and its Related Mechanisms. Br. J. Pharmacol. (2018).","DOI":"10.1111\/bph.14515"},{"issue":"6","key":"62410_CR9","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1097\/HCO.0000000000000216","volume":"30","author":"FM Davis","year":"2015","unstructured":"Davis, F. M., Rateri, D. L. & Daugherty, A. Abdominal aortic aneurysm: Novel mechanisms and therapies. Curr. Opin. Cardiol. 30(6), 566\u2013573 (2015).","journal-title":"Curr. Opin. Cardiol."},{"key":"62410_CR10","doi-asserted-by":"crossref","unstructured":"Fraga-Silva, R. A., Trachet, B. & Stergiopulos, N. Emerging Pharmacological Treatments to Prevent Abdominal Aortic Aneurysm Growth and Rupture. Curr. Pharm. Des. (2015).","DOI":"10.2174\/1381612821666150826095346"},{"key":"62410_CR11","doi-asserted-by":"crossref","unstructured":"Wang, X. et al. Dual-Targeted Theranostic Delivery of miRs Arrests Abdominal Aortic Aneurysm Development. Mol. Ther. (2018).","DOI":"10.1016\/j.ymthe.2018.02.010"},{"issue":"1","key":"62410_CR12","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s10237-017-0955-x","volume":"17","author":"M Forouzandehmehr","year":"2018","unstructured":"Forouzandehmehr, M. & Shamloo, A. Margination and adhesion of micro- and nanoparticles in the coronary circulation: a step towards optimised drug carrier design. Biomech. Model. Mechanobiol. 17(1), 205\u2013221 (2018).","journal-title":"Biomech. Model. Mechanobiol."},{"key":"62410_CR13","doi-asserted-by":"crossref","unstructured":"Shamloo, A., Amani, A., Forouzandehmehr, M. & Ghoytasi, I. In Silico study of patient-specific magnetic drug targeting for a coronary LAD atherosclerotic plaque. Int. J. Pharm. (2019).","DOI":"10.1016\/j.ijpharm.2018.12.088"},{"key":"62410_CR14","doi-asserted-by":"crossref","unstructured":"Sutton, J. T., Haworth, K. J., Pyne-Geithman, G. & Holland, C. K. Ultrasound-mediated drug delivery for cardiovascular disease. Expert Opin. Drug Deliv. (2013).","DOI":"10.1517\/17425247.2013.772578"},{"key":"62410_CR15","doi-asserted-by":"crossref","unstructured":"M\u00fcller, K., Fedosov, D. A. & Gompper, G. Understanding particle margination in blood flow - A step toward optimized drug delivery systems. Med. Eng. Phys. (2016).","DOI":"10.1016\/j.medengphy.2015.08.009"},{"key":"62410_CR16","doi-asserted-by":"crossref","unstructured":"Korin, N. et al. Shear-activated nanotherapeutics for drug targeting to obstructed blood vessels. Science (80-.). (2012).","DOI":"10.1126\/science.1217815"},{"key":"62410_CR17","doi-asserted-by":"crossref","unstructured":"Carboni, E., Tschudi, K., Nam, J., Lu, X. & Ma, A. W. K. Particle Margination and Its Implications on Intravenous Anticancer Drug Delivery. AAPS Pharm. Sci. Tech (2014).","DOI":"10.1208\/s12249-014-0099-6"},{"key":"62410_CR18","doi-asserted-by":"crossref","unstructured":"Asgharian, B., Hofmann, W. & Bergmann, R. Particle deposition in a multiple-path model of the human lung. Aerosol Sci. Technol. (2001).","DOI":"10.1080\/02786820119122"},{"key":"62410_CR19","doi-asserted-by":"crossref","unstructured":"Liu, Y., Shah, S. & Tan, J. Computational Modeling of Nanoparticle Targeted Drug Delivery. Rev. Nanosci. Nanotechnol. (2012).","DOI":"10.1166\/rnn.2012.1014"},{"key":"62410_CR20","doi-asserted-by":"crossref","unstructured":"Mayer, C. R., Geis, N. a, Katus, H. A. & Bekeredjian, R. Ultrasound targeted microbubble destruction for drug and gene delivery. Expert Opin. Drug Deliv. (2008).","DOI":"10.1517\/17425247.5.10.1121"},{"key":"62410_CR21","doi-asserted-by":"crossref","unstructured":"Unger, E., Porter, T., Lindner, J. & Grayburn, P. Cardiovascular drug delivery with ultrasound and microbubbles. Advanced Drug Delivery Reviews. (2014).","DOI":"10.1016\/j.addr.2014.01.012"},{"key":"62410_CR22","doi-asserted-by":"crossref","unstructured":"Klibanov, A. L. Microbubble contrast agents: Targeted ultrasound imaging and ultrasound-assisted drug-delivery applications. Investigative Radiology. (2006).","DOI":"10.1097\/01.rli.0000199292.88189.0f"},{"issue":"5","key":"62410_CR23","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1517\/17425247.4.5.475","volume":"4","author":"JL Bull","year":"2007","unstructured":"Bull, J. L. The application of microbubbles for targeted drug delivery. Expert Opin. Drug Deliv. 4(5), 475\u2013493 (2007).","journal-title":"Expert Opin. Drug Deliv."},{"key":"62410_CR24","doi-asserted-by":"crossref","unstructured":"Postema, M. & Schmitz, G. Ultrasonic bubbles in medicine: Influence of the shell. Ultrason. Sonochem. (2007).","DOI":"10.1016\/j.ultsonch.2006.09.013"},{"key":"62410_CR25","doi-asserted-by":"crossref","unstructured":"Fang, J. Y., Hung, C. F., Liao, M. H. & Chien, C. C. A study of the formulation design of acoustically active lipospheres as carriers for drug delivery. Eur. J. Pharm. Biopharm. (2007).","DOI":"10.1016\/j.ejpb.2007.01.008"},{"key":"62410_CR26","doi-asserted-by":"crossref","unstructured":"May, D. J., Allen, J. S. & Ferrara, K. W. Dynamics and fragmentation of thick-shelled microbubbles. IEEE Trans. Ultrason. Ferroelectr. Freq. Control (2002).","DOI":"10.1109\/TUFFC.2002.1041081"},{"key":"62410_CR27","doi-asserted-by":"crossref","unstructured":"Helfield, B. L. & Goertz, D. E. Nonlinear resonance behavior and linear shell estimates for DefinityTM and MicroMarkerTM assessed with acoustic microbubble spectroscopy. J. Acoust. Soc. Am. (2013).","DOI":"10.1121\/1.4774379"},{"key":"62410_CR28","doi-asserted-by":"crossref","unstructured":"Laing, S. T. & McPherson, D. D. Cardiovascular therapeutic uses of targeted ultrasound contrast agents. Cardiovascular Research. (2009).","DOI":"10.1093\/cvr\/cvp192"},{"key":"62410_CR29","doi-asserted-by":"crossref","unstructured":"Bekeredjian, R., Grayburn, P. A. & Shohet, R. V. Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine. Journal of the American College of Cardiology. (2005).","DOI":"10.1016\/j.jacc.2004.08.067"},{"key":"62410_CR30","doi-asserted-by":"crossref","unstructured":"Postema, M., et al Nitric oxide delivery by ultrasonic cracking: Some limitations. Ultrasonics (2006).","DOI":"10.1016\/j.ultras.2006.06.003"},{"key":"62410_CR31","doi-asserted-by":"crossref","unstructured":"Muzykantov, V. R., Radhakrishnan, R. & Eckmann, D. M. Dynamic Factors Controlling Targeting Nanocarriers to Vascular Endothelium. Curr. Drug Metab. (2012).","DOI":"10.2174\/138920012798356916"},{"key":"62410_CR32","doi-asserted-by":"crossref","unstructured":"Penn, M. S., Rangaswamy, S., Saidel, G. M. & Chisolm, G. M. Macromolecular transport in the arterial intima: comparison of chronic and acute injuries. Am J Physiol (1997).","DOI":"10.1152\/ajpheart.1997.272.4.H1560"},{"key":"62410_CR33","doi-asserted-by":"crossref","unstructured":"Shamloo, A. & Forouzandehmehr, M. Personalised deposition maps for micro- and nanoparticles targeting an atherosclerotic plaque: attributions to the receptor-mediated adsorption on the inflamed endothelial cells. Biomechanics and Modeling in Mechanobiology (2019).","DOI":"10.1007\/s10237-018-01116-y"},{"key":"62410_CR34","doi-asserted-by":"crossref","unstructured":"Lin, S., Han, X., Bi, Y., Ju, S. & Gu, L. Fluid-structure interaction in abdominal aortic aneurysm: Effect of modeling techniques. Biomed Res. Int., vol. 2017 (2017).","DOI":"10.1155\/2017\/7023078"},{"key":"62410_CR35","doi-asserted-by":"crossref","unstructured":"Boyd, A. J., Kuhn, D. C. S., Lozowy, R. J. & Kulbisky, G. P. Low Wall Shear Stress Predominates at Sites of Abdominal Aortic Aneurysm Rupture. J. Vasc. Surg. (2015).","DOI":"10.1016\/j.jvs.2015.08.041"},{"key":"62410_CR36","doi-asserted-by":"crossref","unstructured":"Simsek, F. G. & Kwon, Y. W. Investigation of material modeling in fluid\u2013structure interaction analysis of an idealized three-layered abdominal aorta: aneurysm initiation and fully developed aneurysms. J. Biol. Phys. (2015).","DOI":"10.1007\/s10867-014-9372-x"},{"issue":"1","key":"62410_CR37","doi-asserted-by":"publisher","first-page":"121","DOI":"10.2337\/diacare.4.1.121","volume":"4","author":"JA Colwell","year":"1981","unstructured":"Colwell, J. A., Lopes-Virella, M. & Halushka, P. V. Pathogenesis of Atherosclerosis in Diabetes Mellitus. Diabetes Care 4(1), 121\u2013133 (1981).","journal-title":"Diabetes Care"},{"key":"62410_CR38","doi-asserted-by":"crossref","unstructured":"Sarnak, M. J. et al. Anemia as a risk factor for cardiovascular disease in the Atherosclerosis Risk in Communities (ARIC) study. J. Am. Coll. Cardiol. (2002).","DOI":"10.1016\/S0735-1097(02)01938-1"},{"key":"62410_CR39","doi-asserted-by":"crossref","unstructured":"Pries, A. R., Neuhaus, D. & Gaehtgens, P. Blood viscosity in tube flow: dependence on diameter and hematocrit. Am. J. Physiol. Circ. Physiol. (1992).","DOI":"10.1152\/ajpheart.1992.263.6.H1770"},{"key":"62410_CR40","doi-asserted-by":"crossref","unstructured":"Kwon, O. Effect of Blood Viscosity on Oxygen Transport in Residual Stenosed Artery Following Angioplasty. J. Biomech. Eng. (2008).","DOI":"10.1115\/1.2838029"},{"key":"62410_CR41","doi-asserted-by":"crossref","unstructured":"Gori, F. & Boghi, A. Two new differential equations of turbulent dissipation rate and apparent viscosity for non-newtonian fluids. Int. Commun. Heat Mass Transf. (2011).","DOI":"10.1016\/j.icheatmasstransfer.2011.03.003"},{"key":"62410_CR42","doi-asserted-by":"crossref","unstructured":"Gori, F. & Boghi, A. A three dimensional exact equation for the turbulent dissipation rate of Generalised Newtonian Fluids. Int. Commun. Heat Mass Transf. (2012).","DOI":"10.1016\/j.icheatmasstransfer.2012.02.010"},{"key":"62410_CR43","doi-asserted-by":"crossref","unstructured":"Gavrilov, A. A. & Rudyak, V. Y. Reynolds-averaged modeling of turbulent flows of power-law fluids. J. Nonnewton. Fluid Mech. (2016).","DOI":"10.1016\/j.jnnfm.2015.11.006"},{"key":"62410_CR44","doi-asserted-by":"crossref","unstructured":"Gavrilov, A. A. & Rudyak, V. Y. Direct numerical simulation of the turbulent energy balance and the shear stresses in power-law fluid flows in pipes. Fluid Dyn. (2017).","DOI":"10.1134\/S0015462817030048"},{"key":"62410_CR45","doi-asserted-by":"crossref","unstructured":"Scotti, C. M. & Finol, E. A. Compliant biomechanics of abdominal aortic aneurysms: A fluid-structure interaction study. Comput. Struct. (2007).","DOI":"10.1016\/j.compstruc.2006.08.041"},{"key":"62410_CR46","doi-asserted-by":"crossref","unstructured":"Qin, S., Caskey, C. F. & Ferrara, K. W. Ultrasound contrast microbubbles in imaging and therapy: Physical principles and engineering. Phys. Med. Biol. (2009).","DOI":"10.1088\/0031-9155\/54\/6\/R01"},{"key":"62410_CR47","doi-asserted-by":"crossref","unstructured":"Guan, J. & Matula, T. J. Using light scattering to measure the response of individual ultrasound contrast microbubbles subjected to pulsed ultrasound in vitro. J. Acoust. Soc. Am. (2004).","DOI":"10.1121\/1.1795334"},{"key":"62410_CR48","doi-asserted-by":"crossref","unstructured":"Marmottant, P. et al. A Model for Large Amplitude Oscillations of Coated Bubbles Accounting for Buckling and Rupture. J. Acoust. Soc. Am. (2005).","DOI":"10.1121\/1.2109427"},{"key":"62410_CR49","doi-asserted-by":"crossref","unstructured":"Borden, M. A. & Song, K. H. Reverse engineering the ultrasound contrast agent. Advances in Colloid and Interface Science. (2018).","DOI":"10.1016\/j.cis.2018.10.004"},{"key":"62410_CR50","unstructured":"Rooij, T. T. T, Ultrasound Contrast Agents for Imaging and Therapy. (2017)."},{"key":"62410_CR51","unstructured":"Kirby, B. J., Micro- and Nanoscale Fluid Mechanics, Transport in Microfluidic Devices. (2010)."},{"key":"62410_CR52","doi-asserted-by":"crossref","unstructured":"Turton, R. & Levenspiel, O. A short note on the drag correlation for spheres. Powder Technol. (1986).","DOI":"10.1016\/0032-5910(86)80012-2"},{"key":"62410_CR53","doi-asserted-by":"crossref","unstructured":"Saffman, P. G. The lift on a small sphere in a slow shear flow. J. Fluid Mech. (1965).","DOI":"10.1017\/S0022112065000824"},{"key":"62410_CR54","doi-asserted-by":"crossref","unstructured":"Furlani, E. P. Magnetophoretic separation of blood cells at the microscale. J. Phys. D. Appl. Phys. (2007).","DOI":"10.1088\/0022-3727\/40\/5\/001"},{"key":"62410_CR55","doi-asserted-by":"crossref","unstructured":"Jorgensen, W. L. & Tirado-Rives, J. The OPLS Potential Functions for Proteins. Energy Minimizations for Crystals of Cyclic Peptides and Crambin. J. Am. Chem. Soc. (1988).","DOI":"10.1021\/ja00214a001"},{"key":"62410_CR56","doi-asserted-by":"crossref","unstructured":"Maul, T. M. et al. Optimization of ultrasound contrast agents with computational models to improve selection of ligands and binding strength. Biotechnol. Bioeng. (2010).","DOI":"10.1002\/bit.22857"},{"key":"62410_CR57","doi-asserted-by":"crossref","unstructured":"Decuzzi, P. & Ferrari, M. The adhesive strength of non-spherical particles mediated by specific interactions. Biomaterials (2006).","DOI":"10.1016\/j.biomaterials.2006.05.024"},{"key":"62410_CR58","doi-asserted-by":"crossref","unstructured":"Goldman, A. J., Cox, R. G. & Brenner, H. Slow viscous motion of a sphere parallel to a plane wall-II Couette flow. Chem. Eng. Sci. (1967).","DOI":"10.1016\/0009-2509(67)80048-4"},{"key":"62410_CR59","unstructured":"Ascher, U. M. & Petzold, L. R. Computer Methods for Ordinary Differential Equations and Differential-Algebraic Equations. (2011)."},{"key":"62410_CR60","unstructured":"Curtiss, C. F. & Hirschfelder, J. O. Integration of Stiff Equations. Proc. Natl. Acad. Sci. (2006)."},{"key":"62410_CR61","unstructured":"Chung, J. & Hulbert, G. M. A Time Integration Algorithm for Structural Dynamics With Improved Numerical Dissipation: The Generalized-\u03b1 Method. J. Appl. Mech. (2008)."},{"issue":"11\u201314","key":"62410_CR62","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.compstruc.2006.08.041","volume":"85","author":"CM Scotti","year":"2007","unstructured":"Scotti, C. M. & Finol, E. A. Compliant biomechanics of abdominal aortic aneurysms: A fluid-structure interaction study. Comput. Struct. 85(11\u201314), 1097\u20131113 (2007).","journal-title":"Comput. Struct."},{"issue":"3","key":"62410_CR63","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1080\/10255840701827412","volume":"11","author":"CM Scotti","year":"2008","unstructured":"Scotti, C. M., Jimenez, J., Muluk, S. C. & Finol, E. A. Wall stress and flow dynamics in abdominal aortic aneurysms: Finite element analysis vs. fluid-structure interaction. Comput. Methods Biomech. Biomed. Engin. 11(3), 301\u2013322 (2008).","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"62410_CR64","doi-asserted-by":"crossref","unstructured":"Crowe, C., Schwarzkopf, J., Sommerfeld, M. & Tsuji, Y., Multiphase Flows with Droplets and Particles, Second Edition. (2011).","DOI":"10.1201\/b11103"},{"issue":"4","key":"62410_CR65","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1007\/s12668-018-0554-z","volume":"8","author":"T Canchi","year":"2018","unstructured":"Canchi, T., Saxena, A., Ng, E. Y. K., Pwee, E. C. H. & Narayanan, S. Application of Fluid\u2013Structure Interaction Methods to Estimate the Mechanics of Rupture in Asian Abdominal Aortic Aneurysms. Bionanoscience 8(4), 1035\u20131044 (2018).","journal-title":"Bionanoscience"},{"key":"62410_CR66","doi-asserted-by":"crossref","unstructured":"Sohrabi, S., Zheng, J., Finol, E. A. & Liu, Y. Numerical Simulation of Particle Transport and Deposition in the Pulmonary Vasculature. J. Biomech. Eng. (2014).","DOI":"10.1115\/1.4028800"},{"key":"62410_CR67","doi-asserted-by":"crossref","unstructured":"Rychak, J. J., Klibanov, A. L. & Hossack, J. A. Acoustic radiation force enhances targeted delivery of ultrasound contrast microbubbles: In vitro verification. IEEE Trans. Ultrason. Ferroelectr. Freq. Control (2005).","DOI":"10.1109\/TUFFC.2005.1417264"},{"key":"62410_CR68","doi-asserted-by":"crossref","unstructured":"Fong, S. W., Klaseboer, E. & Khoo, B. C. Interaction of microbubbles with high intensity pulsed ultrasound. J. Acoust. Soc. Am. (2008).","DOI":"10.1121\/1.2933429"},{"key":"62410_CR69","unstructured":"de Saint Victor, M.-A. Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis. University of Oxford (2016)."},{"key":"62410_CR70","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.jbiomech.2015.03.007","volume":"48","author":"A Shamloo","year":"2015","unstructured":"Shamloo, A., Manuchehrfar, F. & Rafii-Tabar, H. A viscoelastic model for axonal microtubule rupture. J. Biomech 48, 1241\u20131247 (2015).","journal-title":"J. Biomech"},{"key":"62410_CR71","doi-asserted-by":"crossref","unstructured":"Raghavan, M. L. & Vorp, D. A. Toward a biomechanical tool to evaluate rupture potential of abdominal aortic aneurysm: Identification of a finite strain constitutive model and evaluation of its applicability. J. Biomech. (2000).","DOI":"10.1016\/S0021-9290(99)00201-8"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62410-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62410-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62410-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T08:59:31Z","timestamp":1670317171000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62410-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,25]]},"references-count":71,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["62410"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-62410-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,25]]},"assertion":[{"value":"27 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5393"}}