{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T23:31:56Z","timestamp":1794958316856,"version":"4.9.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,3,30]],"date-time":"2020-03-30T00:00:00Z","timestamp":1585526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,3,30]],"date-time":"2020-03-30T00:00:00Z","timestamp":1585526400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In order to evaluate the technical adaptability of a type of disposable endoscope compared to reusable flexible endoscopes, <jats:italic>in vitro<\/jats:italic> and <jats:italic>in vivo<\/jats:italic> studies were conducted. A disposable digital ureteroscope (\u201cchip on tip\u201d) and two reusable endoscopes were investigated with respect to spatial resolution, geometric distortion in air and water the maximum. Additionally, the clinical performance of the disposable device was tested during clinical procedures (n\u2009=\u200920). The disposable endoscope showed an optical resolution of 6.72 lines\/mm at 10\u2009mm distance, similar to the other devices. In comparison, the disposable endoscope showed a barrel-shaped image distortion in air of \u221224.2%, which is in the middle range, but was best under water (\u22128.6%). The bendability of 297\u00b0 (275\u2009\u00b5m fiber) and 316\u00b0 (empty channel, 1.5\u2009F basket) and the maximum irrigation (1\u2009m: 58.1\u2009ml\/min, 2\u2009m: 91.9\u2009ml\/min) were convincing. Clinically the maneuverability was very good in (13\/20), good or satisfactory in (7\/20). Visibility was evaluated as very good in (11\/20), just in (1\/20) either satisfactory or sufficient. The consistency of visibility was not affected in (19\/20). In all cases there were no adverse events. The technical examination and clinical application of the disposable endoscope are of equal quality compared to reusable devices. Disposable endoscopes can be an alternative to reusable devices, but economic aspects such as reduction of repair costs, sterilization effort and additional waste must be taken into account.<\/jats:p>","DOI":"10.1038\/s41598-020-62657-w","type":"journal-article","created":{"date-parts":[[2020,3,30]],"date-time":"2020-03-30T10:04:00Z","timestamp":1585562640000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Comparative investigation of reusable and single\u2013use flexible endoscopes for urological interventions"],"prefix":"10.1038","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7321-7302","authenticated-orcid":false,"given":"Maximilian","family":"Eisel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Strittmatter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Str\u00f6bl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Freym\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Pongratz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald","family":"Sroka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,3,30]]},"reference":[{"key":"62657_CR1","doi-asserted-by":"publisher","unstructured":"Carey, R. I. et al. Frequency of ureteroscope damage seen at a tertiary care center. J. Urol. 176, 607\u2013610; discussion 610, https:\/\/doi.org\/10.1016\/j.juro.2006.03.059 (2006).","DOI":"10.1016\/j.juro.2006.03.059"},{"key":"62657_CR2","doi-asserted-by":"publisher","first-page":"2418","DOI":"10.1016\/j.juro.2007.09.107","volume":"178","author":"GM Preminger","year":"2007","unstructured":"Preminger, G. M. et al. 2007 guideline for the management of ureteral calculi. J Urol 178, 2418\u20132434, https:\/\/doi.org\/10.1016\/j.juro.2007.09.107 (2007).","journal-title":"J Urol"},{"key":"62657_CR3","doi-asserted-by":"publisher","first-page":"E837","DOI":"10.5489\/cuaj.3483","volume":"9","author":"M Ordon","year":"2015","unstructured":"Ordon, M. et al. CUA Guideline: Management of ureteral calculi. Canadian Urological Association journal = Journal de l\u2019Association des urologues du Canada 9, E837\u2013851, https:\/\/doi.org\/10.5489\/cuaj.3483 (2015).","journal-title":"Canadian Urological Association journal = Journal de l\u2019Association des urologues du Canada"},{"key":"62657_CR4","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1016\/j.urology.2013.07.017","volume":"82","author":"BK Somani","year":"2013","unstructured":"Somani, B. K., Al-Qahtani, S. M., de Medina, S. D. & Traxer, O. Outcomes of flexible ureterorenoscopy and laser fragmentation for renal stones: comparison between digital and conventional ureteroscope. Urology 82, 1017\u20131019, https:\/\/doi.org\/10.1016\/j.urology.2013.07.017 (2013).","journal-title":"Urology"},{"key":"62657_CR5","doi-asserted-by":"publisher","unstructured":"Dale, J. et al. Evaluation of a Novel Single-Use Flexible Ureteroscope. J Endourol, https:\/\/doi.org\/10.1089\/end.2016.0237 (2017).","DOI":"10.1089\/end.2016.0237"},{"key":"62657_CR6","doi-asserted-by":"publisher","first-page":"133","DOI":"10.4103\/0974-7796.84963","volume":"3","author":"SM Al-Qahtani","year":"2011","unstructured":"Al-Qahtani, S. M., Geavlete, B., Geavlette, B. P., de Medina, S. G. & Traxer, O. P. The new Olympus digital flexible ureteroscope (URF-V): Initial experience. Urology annals 3, 133\u2013137, https:\/\/doi.org\/10.4103\/0974-7796.84963 (2011).","journal-title":"Urology annals"},{"key":"62657_CR7","unstructured":"Wilson, C. R., Kennedy, J. D. D., Irby, P. B. & Fried, N. M. 9 (SPIE)."},{"key":"62657_CR8","doi-asserted-by":"publisher","first-page":"19","DOI":"10.2147\/RRU.S104229","volume":"9","author":"CM Gridley","year":"2017","unstructured":"Gridley, C. M. & Knudsen, B. E. Digital ureteroscopes: technology update. Research and reports in urology 9, 19\u201325, https:\/\/doi.org\/10.2147\/RRU.S104229 (2017).","journal-title":"Research and reports in urology"},{"key":"62657_CR9","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/S0094-0143(03)00089-2","volume":"31","author":"DB Johnson","year":"2004","unstructured":"Johnson, D. B. & Pearle, M. S. Complications of ureteroscopy. The Urologic clinics of North America 31, 157\u2013171, https:\/\/doi.org\/10.1016\/S0094-0143(03)00089-2 (2004).","journal-title":"The Urologic clinics of North America"},{"key":"62657_CR10","doi-asserted-by":"publisher","first-page":"591","DOI":"10.3892\/etm.2013.1184","volume":"6","author":"SP Gu","year":"2013","unstructured":"Gu, S. P. et al. Clinical effectiveness of the PolyScope endoscope system combined with holmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cm. Exp Ther Med 6, 591\u2013595, https:\/\/doi.org\/10.3892\/etm.2013.1184 (2013).","journal-title":"Exp Ther Med"},{"key":"62657_CR11","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1007\/s00345-017-2131-4","volume":"36","author":"NF Davis","year":"2018","unstructured":"Davis, N. F. et al. Single-use flexible ureteropyeloscopy: a systematic review. World J Urol 36, 529\u2013536, https:\/\/doi.org\/10.1007\/s00345-017-2131-4 (2018).","journal-title":"World J Urol"},{"key":"62657_CR12","doi-asserted-by":"publisher","unstructured":"Legemate, J. D. et al. Durability of Flexible Ureteroscopes: A Prospective Evaluation of Longevity, the Factors that Affect it, and Damage Mechanisms. European Urology Focus, https:\/\/doi.org\/10.1016\/j.euf.2018.03.001.","DOI":"10.1016\/j.euf.2018.03.001"},{"key":"62657_CR13","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1089\/end.2017.0523","volume":"32","author":"K Taguchi","year":"2018","unstructured":"Taguchi, K. et al. Micro-Costing Analysis Demonstrates Comparable Costs for LithoVue Compared to Reusable Flexible Fiberoptic Ureteroscopes. J Endourol 32, 267\u2013273, https:\/\/doi.org\/10.1089\/end.2017.0523 (2018).","journal-title":"J Endourol"},{"key":"62657_CR14","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1089\/end.2015.0642","volume":"30","author":"E Kramolowsky","year":"2016","unstructured":"Kramolowsky, E., McDowell, Z., Moore, B., Booth, B. & Wood, N. Cost Analysis of Flexible Ureteroscope Repairs: Evaluation of 655 Procedures in a Community-Based Practice. J Endourol 30, 254\u2013256, https:\/\/doi.org\/10.1089\/end.2015.0642 (2016).","journal-title":"J Endourol"},{"key":"62657_CR15","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1089\/end.2014.0435","volume":"29","author":"JJ Tosoian","year":"2015","unstructured":"Tosoian, J. J., Ludwig, W., Sopko, N., Mullins, J. K. & Matlaga, B. R. The effect of repair costs on the profitability of a ureteroscopy program. J Endourol 29, 406\u2013409, https:\/\/doi.org\/10.1089\/end.2014.0435 (2015).","journal-title":"J Endourol"},{"key":"62657_CR16","unstructured":"afs-medical. Pusen Produktinformation, https:\/\/www.afs-medical.com\/sites\/default\/files\/product_downloads\/pusen_produktinformation_ue3011-3022_dt_201701.pdf (April 18 2018)."},{"key":"62657_CR17","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1089\/end.2017.0785","volume":"32","author":"GS Marchini","year":"2018","unstructured":"Marchini, G. S. et al. In Vitro Evaluation of Single-Use Digital Flexible Ureteroscopes: A Practical Comparison for a Patient-Centered Approach. J Endourol 32, 184\u2013191, https:\/\/doi.org\/10.1089\/end.2017.0785 (2018).","journal-title":"J Endourol"},{"key":"62657_CR18","doi-asserted-by":"crossref","unstructured":"Gross, H. Handbook of optical systems. (Wiley-VCH, 2005).","DOI":"10.1002\/9783527699223"},{"key":"62657_CR19","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s11340-014-9886-y","volume":"55","author":"PL Reu","year":"2015","unstructured":"Reu, P. L., Sweatt, W., Miller, T. & Fleming, D. Camera System Resolution and its Influence on Digital Image Correlation. Experimental Mechanics 55, 9\u201325, https:\/\/doi.org\/10.1007\/s11340-014-9886-y (2015).","journal-title":"Experimental Mechanics"},{"key":"62657_CR20","unstructured":"Fischer, R. E. Optical System Design. Second edn, 85 pp. (The McGraw-Hill Companies, 2008)."},{"key":"62657_CR21","doi-asserted-by":"crossref","unstructured":"Gross, H., Z\u00fcgge, H., Peschka, M., Blechinger, F. & Gross, H. Aberration theory and correction of optical systems. (Wiley-VCH, 2007).","DOI":"10.1002\/9783527699254"},{"key":"62657_CR22","unstructured":"Pedrotti, F., Pedrotti, L., Bausch, W. & Schmidt, H. Optik f\u00fcr Ingenieure."},{"key":"62657_CR23","doi-asserted-by":"publisher","unstructured":"Legemate, J. D. et al. Durability of Flexible Ureteroscopes: A Prospective Evaluation of Longevity, the Factors that Affect it, and Damage Mechanisms. European urology focus, https:\/\/doi.org\/10.1016\/j.euf.2018.03.001 (2018).","DOI":"10.1016\/j.euf.2018.03.001"},{"key":"62657_CR24","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1016\/S0022-5347(05)67133-9","volume":"164","author":"JS Afane","year":"2000","unstructured":"Afane, J. S. et al. Flexible ureteroscopes: a single center evaluation of the durability and function of the new endoscopes smaller than 9Fr. J Urol 164, 1164\u20131168 (2000).","journal-title":"J Urol"},{"key":"62657_CR25","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1016\/j.urology.2013.01.016","volume":"81","author":"T Karaolides","year":"2013","unstructured":"Karaolides, T. et al. Improving the durability of digital flexible ureteroscopes. Urology 81, 717\u2013722, https:\/\/doi.org\/10.1016\/j.urology.2013.01.016 (2013).","journal-title":"Urology"},{"key":"62657_CR26","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1016\/j.ajic.2017.03.016","volume":"45","author":"CL Ofstead","year":"2017","unstructured":"Ofstead, C. L. et al. The effectiveness of sterilization for flexible ureteroscopes: A real-world study. American journal of infection control 45, 888\u2013895, https:\/\/doi.org\/10.1016\/j.ajic.2017.03.016 (2017).","journal-title":"American journal of infection control"},{"key":"62657_CR27","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jhin.2013.06.010","volume":"85","author":"CL Chang","year":"2013","unstructured":"Chang, C. L. et al. Outbreak of ertapenem-resistant Enterobacter cloacae urinary tract infections due to a contaminated ureteroscope. The Journal of hospital infection 85, 118\u2013124, https:\/\/doi.org\/10.1016\/j.jhin.2013.06.010 (2013).","journal-title":"The Journal of hospital infection"},{"key":"62657_CR28","doi-asserted-by":"publisher","first-page":"5518","DOI":"10.1364\/OL.40.005518","volume":"40","author":"N Uribe-Patarroyo","year":"2015","unstructured":"Uribe-Patarroyo, N. & Bouma, B. E. Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation. Optics Letters 40, 5518\u20135521, https:\/\/doi.org\/10.1364\/OL.40.005518 (2015).","journal-title":"Optics Letters"},{"key":"62657_CR29","doi-asserted-by":"publisher","first-page":"2603","DOI":"10.1109\/tbme.2013.2261816","volume":"60","author":"TY Lee","year":"2013","unstructured":"Lee, T. Y. et al. Automatic distortion correction of endoscopic images captured with wide-angle zoom lens. IEEE transactions on bio-medical engineering 60, 2603\u20132613, https:\/\/doi.org\/10.1109\/tbme.2013.2261816 (2013).","journal-title":"IEEE transactions on bio-medical engineering"},{"key":"62657_CR30","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1109\/42.932745","volume":"20","author":"JP Helferty","year":"2001","unstructured":"Helferty, J. P., Zhang, C., McLennan, G. & Higgins, W. E. Videoendoscopic distortion correction and its application to virtual guidance of endoscopy. IEEE Trans Med Imaging 20, 605\u2013617, https:\/\/doi.org\/10.1109\/42.932745 (2001).","journal-title":"IEEE Trans Med Imaging"},{"key":"62657_CR31","unstructured":"Nakano, S., Hori, F. & Ogawa, K. (Google Patents, 2015)."},{"key":"62657_CR32","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1089\/end.2018.0141","volume":"32","author":"BE Knudsen","year":"2018","unstructured":"Knudsen, B. E. Editorial Comment on: Micro-Costing Analysis Demonstrates Comparable Costs for LithoVue Compared to Reusable Flexible Fiberoptic Ureteroscopes by Taguchi et al. J Endourol 32, 274, https:\/\/doi.org\/10.1089\/end.2018.0141 (2018).","journal-title":"J Endourol"},{"key":"62657_CR33","doi-asserted-by":"publisher","first-page":"e0157014","DOI":"10.1371\/journal.pone.0157014","volume":"11","author":"MJ Eckelman","year":"2016","unstructured":"Eckelman, M. J. & Sherman, J. Environmental impacts of the US health care system and effects on public health. PLoS One 11, e0157014 (2016).","journal-title":"PLoS One"},{"key":"62657_CR34","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1016\/j.eururo.2017.02.016","volume":"72","author":"S Doizi","year":"2017","unstructured":"Doizi, S. & Traxer, O. Re: Evaluation of a Novel Single-use Flexible Ureteroscope. Eur Urol 72, 152\u2013153, https:\/\/doi.org\/10.1016\/j.eururo.2017.02.016 (2017).","journal-title":"Eur Urol"},{"key":"62657_CR35","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/den.12745","volume":"29","author":"A Murdani","year":"2017","unstructured":"Murdani, A. et al. WEO position statement on hygiene in digestive endoscopy: Focus on endoscopy units in Asia and the Middle East. Dig Endosc 29, 3\u201315, https:\/\/doi.org\/10.1111\/den.12745 (2017).","journal-title":"Dig Endosc"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62657-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62657-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62657-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T09:12:18Z","timestamp":1670317938000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-62657-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,30]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["62657"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-62657-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,30]]},"assertion":[{"value":"16 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5701"}}