{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T19:39:46Z","timestamp":1785526786853,"version":"3.56.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T00:00:00Z","timestamp":1587686400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T00:00:00Z","timestamp":1587686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (\u2207<jats:italic>T<\/jats:italic>) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470\u2009nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA \u2013 SYBR Green I complex with a known melting temperature (<jats:italic>T<\/jats:italic><jats:sub>M<\/jats:sub>) in a flow-through configuration without gradient to verify the functionality of the proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to \u2207<jats:italic>T<\/jats:italic> of \u2248 2.31\u2009\u00b0C mm<jats:sup>\u22121<\/jats:sup>, determining the heat transfer time as \u2248 554\u2009ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.<\/jats:p>","DOI":"10.1038\/s41598-020-63620-5","type":"journal-article","created":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T10:27:15Z","timestamp":1587724035000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Rapid Characterization of Biomolecules\u2019 Thermal Stability in a Segmented Flow-Through Optofluidic Microsystem"],"prefix":"10.1038","volume":"10","author":[{"given":"Zdenka","family":"Fohlerova","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanliang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaromir","family":"Hubalek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng","family":"Ni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Levent","family":"Yobas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Podesva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandr","family":"Otahal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Neuzil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,4,24]]},"reference":[{"key":"63620_CR1","doi-asserted-by":"publisher","first-page":"3503","DOI":"10.1098\/rsif.2012.0520","volume":"9","author":"EB Dolan","year":"2012","unstructured":"Dolan, E. B., Haugh, M. G., Tallon, D., Casey, C. & McNamara, L. M. Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting. J R Soc 9, 3503\u20133513, https:\/\/doi.org\/10.1098\/rsif.2012.0520 (2012).","journal-title":"J R Soc"},{"key":"63620_CR2","doi-asserted-by":"publisher","first-page":"e93865","DOI":"10.1371\/journal.pone.0093865","volume":"9","author":"M Vergara","year":"2014","unstructured":"Vergara, M. et al. Differential Effect of Culture Temperature and Specific Growth Rate on CHO Cell Behavior in Chemostat Culture. PLOS ONE 9, e93865, https:\/\/doi.org\/10.1371\/journal.pone.0093865 (2014).","journal-title":"PLOS ONE"},{"key":"63620_CR3","doi-asserted-by":"publisher","unstructured":"Katava, M. et al. Critical structural fluctuations of proteins upon thermal unfolding challenge the Lindemann criterion. Proc. Natl. Acad. Sci. USA, 201707357, https:\/\/doi.org\/10.1073\/pnas.1707357114 (2017).","DOI":"10.1073\/pnas.1707357114"},{"key":"63620_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-38822-1","volume":"9","author":"J Tanaka","year":"2019","unstructured":"Tanaka, J. et al. KRAS genotyping by digital PCR combined with melting curve analysis. Sci Rep 9, 2626, https:\/\/doi.org\/10.1038\/s41598-019-38822-1 (2019).","journal-title":"Sci Rep"},{"key":"63620_CR5","doi-asserted-by":"publisher","first-page":"33","DOI":"10.3390\/diagnostics3010033","volume":"3","author":"V Miralles","year":"2013","unstructured":"Miralles, V., Huerre, A., Malloggi, F. & Jullien, M.-C. A Review of Heating and Temperature Control in Microfluidic Systems: Techniques and Applications. Diagnostics 3, 33\u201367, https:\/\/doi.org\/10.3390\/diagnostics3010033 (2013).","journal-title":"Diagnostics"},{"key":"63620_CR6","doi-asserted-by":"publisher","first-page":"085502","DOI":"10.1088\/0022-3727\/41\/8\/085502","volume":"41","author":"SM Sohel Murshed","year":"2008","unstructured":"Sohel Murshed, S. M., Tan, S.-H. & Nguyen, N.-T. Temperature dependence of interfacial properties and viscosity of nanofluids for droplet-based microfluidics.  J. Phys. D 41, 085502, https:\/\/doi.org\/10.1088\/0022-3727\/41\/8\/085502 (2008).","journal-title":"J. Phys. D"},{"key":"63620_CR7","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1007\/s10404-008-0323-3","volume":"6","author":"SMS Murshed","year":"2009","unstructured":"Murshed, S. M. S., Tan, S. H., Nguyen, N. T., Wong, T. N. & Yobas, L. Microdroplet formation of water and nanofluids in heat-induced microfluidic T-junction. Microfluid Nanofluid 6, 253\u2013259, https:\/\/doi.org\/10.1007\/s10404-008-0323-3 (2009).","journal-title":"Microfluid Nanofluid"},{"key":"63620_CR8","doi-asserted-by":"publisher","first-page":"5127","DOI":"10.1021\/la8041605","volume":"25","author":"E Verneuil","year":"2009","unstructured":"Verneuil, E., Cordero, M., Gallaire, F. & Baroud, C. N. Laser-Induced Force on a Microfluidic Drop: Origin and Magnitude. Langmuir 25, 5127\u20135134, https:\/\/doi.org\/10.1021\/la8041605 (2009).","journal-title":"Langmuir"},{"key":"63620_CR9","doi-asserted-by":"publisher","first-page":"1978","DOI":"10.1021\/acs.analchem.6b04520","volume":"89","author":"G Yesiloz","year":"2017","unstructured":"Yesiloz, G., Boybay, M. S. & Ren, C. L. Effective Thermo-Capillary Mixing in Droplet Microfluidics Integrated with a Microwave Heater. Anal Chem 89, 1978\u20131984, https:\/\/doi.org\/10.1021\/acs.analchem.6b04520 (2017).","journal-title":"Anal Chem"},{"key":"63620_CR10","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-40069-9","volume":"9","author":"A Khater","year":"2019","unstructured":"Khater, A., Mohammadi, M., Mohamad, A. & Nezhad, A. S. Dynamics of temperature-actuated droplets within microfluidics. Sci Rep 9, 3832, https:\/\/doi.org\/10.1038\/s41598-019-40069-9 (2019).","journal-title":"Sci Rep"},{"key":"63620_CR11","doi-asserted-by":"publisher","first-page":"082006","DOI":"10.1063\/1.4819134","volume":"25","author":"PC Ho","year":"2013","unstructured":"Ho, P. C. & Nguyen, N.-T. Numerical study of thermocoalescence of microdroplets in a microfluidic chamber. Phys. Fluids 25, 082006, https:\/\/doi.org\/10.1063\/1.4819134 (2013).","journal-title":"Phys. Fluids"},{"key":"63620_CR12","doi-asserted-by":"publisher","first-page":"126813","DOI":"10.1016\/j.snb.2019.126813","volume":"298","author":"J-H Liu","year":"2019","unstructured":"Liu, J.-H., Hsia, K.-C., Yokokawa, R. & Lu, Y.-W. Microtubule polymerization in alignment by an on-chip temperature gradient platform. Sens. Actuator B-Chem. 298, 126813, https:\/\/doi.org\/10.1016\/j.snb.2019.126813 (2019).","journal-title":"Sens. Actuator B-Chem."},{"key":"63620_CR13","doi-asserted-by":"publisher","first-page":"064109","DOI":"10.1063\/1.4902907","volume":"8","author":"K-C Li","year":"2014","unstructured":"Li, K.-C., Ding, S.-T., Lin, E.-C., Wang, L. A. & Lu, Y.-W. Melting analysis on microbeads in rapid temperature-gradient inside microchannels for single nucleotide polymorphisms detection. Biomicrofluidics 8, 064109\u2013064109, https:\/\/doi.org\/10.1063\/1.4902907 (2014).","journal-title":"Biomicrofluidics"},{"key":"63620_CR14","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1021\/ac034377+","volume":"76","author":"A Dodge","year":"2004","unstructured":"Dodge, A., Turcatti, G., Lawrence, I., de Rooij, N. F. & Verpoorte, E. A Microfluidic Platform Using Molecular Beacon-Based Temperature Calibration for Thermal Dehybridization of Surface-Bound DNA. Anal Chem 76, 1778\u20131787, https:\/\/doi.org\/10.1021\/ac034377+ (2004).","journal-title":"Anal Chem"},{"key":"63620_CR15","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1039\/B605957K","volume":"2","author":"P Neuzil","year":"2006","unstructured":"Neuzil, P., Pipper, J. & Hsieh, T. M. Disposable real-time microPCR device: lab-on-a-chip at a low cost. Mol. Biosyst. 2, 292\u2013298, https:\/\/doi.org\/10.1039\/B605957K (2006).","journal-title":"Mol. Biosyst."},{"key":"63620_CR16","doi-asserted-by":"publisher","first-page":"7566","DOI":"10.3390\/ma7117566","volume":"7","author":"E Davies","year":"2014","unstructured":"Davies, E., Christodoulides, P., Florides, G. & Kalli, K. Microfluidic Flows and Heat Transfer and Their Influence on Optical Modes in Microstructure Fibers. Materials 7, 7566\u20137582, https:\/\/doi.org\/10.3390\/ma7117566 (2014).","journal-title":"Materials"},{"key":"63620_CR17","doi-asserted-by":"publisher","first-page":"5133","DOI":"10.1016\/S0017-9310(02)00223-5","volume":"45","author":"KC Toh","year":"2002","unstructured":"Toh, K. C., Chen, X. Y. & Chai, J. C. Numerical computation of fluid flow and heat transfer in microchannels.  Int. J. Heat Mass Transf 45, 5133\u20135141, https:\/\/doi.org\/10.1016\/S0017-9310(02)00223-5 (2002).","journal-title":"Int. J. Heat Mass Transf"},{"key":"63620_CR18","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1016\/j.ijheatmasstransfer.2018.06.037","volume":"126","author":"MR Hajmohammadi","year":"2018","unstructured":"Hajmohammadi, M. R., Alipour, P. & Parsa, H. Microfluidic effects on the heat transfer enhancement and optimal design of microchannels heat sinks.  Int. J. Heat Mass Transf 126, 808\u2013815, https:\/\/doi.org\/10.1016\/j.ijheatmasstransfer.2018.06.037 (2018).","journal-title":"Int. J. Heat Mass Transf"},{"key":"63620_CR19","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1039\/B611745G","volume":"7","author":"L Novak","year":"2007","unstructured":"Novak, L., Neuzil, P., Pipper, J., Zhang, Y. & Lee, S. An integrated fluorescence detection system for lab-on-a-chip applications. Lab Chip 7, 27\u201329 (2007).","journal-title":"Lab Chip"},{"key":"63620_CR20","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1039\/C5LC01415H","volume":"16","author":"CD Ahrberg","year":"2016","unstructured":"Ahrberg, C. D., Ilic, B. R., Manz, A. & Neu\u017eil, P. Handheld real-time PCR device. Lab Chip 16, 586\u2013592 (2016).","journal-title":"Lab Chip"},{"key":"63620_CR21","doi-asserted-by":"publisher","first-page":"4803","DOI":"10.1021\/acs.analchem.6b00278","volume":"88","author":"CD Ahrberg","year":"2016","unstructured":"Ahrberg, C. D., Manz, A. & Neuz\u030cil, P. Palm-sized device for point-of-care Ebola detection. Anal Chem 88, 4803\u20134807 (2016).","journal-title":"Anal Chem"},{"key":"63620_CR22","doi-asserted-by":"publisher","first-page":"2632","DOI":"10.1039\/c004921b","volume":"10","author":"P Neuzil","year":"2010","unstructured":"Neuzil, P. et al. Rapid detection of viral RNA by a pocket-size real-time PCR system. Lab Chip 10, 2632\u20132634 (2010).","journal-title":"Lab Chip"},{"key":"63620_CR23","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1515\/nanoph-2016-0156","volume":"6","author":"D Ozcelik","year":"2017","unstructured":"Ozcelik, D., Cai, H., Leake, K. D., Hawkins, A. R. & Schmidt, H. Optofluidic bioanalysis: fundamentals and applications. Nanophotonics 6, 647\u2013661, https:\/\/doi.org\/10.1515\/nanoph-2016-0156 (2017).","journal-title":"Nanophotonics"},{"key":"63620_CR24","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1038\/nphoton.2011.206","volume":"5","author":"X Fan","year":"2011","unstructured":"Fan, X. & White, I. M. Optofluidic microsystems for chemical and biological analysis. Nat Photonics 5, 591\u2013597, https:\/\/doi.org\/10.1038\/nphoton.2011.206 (2011).","journal-title":"Nat Photonics"},{"key":"63620_CR25","doi-asserted-by":"publisher","first-page":"152","DOI":"10.3390\/mi8050152","volume":"8","author":"C Song","year":"2017","unstructured":"Song, C. & Tan, S. H. A Perspective on the Rise of Optofluidics and the Future. Micromachines (Basel) 8, 152, https:\/\/doi.org\/10.3390\/mi8050152 (2017).","journal-title":"Micromachines (Basel)"},{"key":"63620_CR26","doi-asserted-by":"publisher","first-page":"2631","DOI":"10.1039\/C7LC00460E","volume":"17","author":"G Persichetti","year":"2017","unstructured":"Persichetti, G., Grimaldi, I. A., Testa, G. & Bernini, R. Multifunctional optofluidic lab-on-chip platform for Raman and fluorescence spectroscopic microfluidic analysis. Lab Chip 17, 2631\u20132639, https:\/\/doi.org\/10.1039\/C7LC00460E (2017).","journal-title":"Lab Chip"},{"key":"63620_CR27","doi-asserted-by":"publisher","first-page":"12880","DOI":"10.1021\/acs.analchem.7b03526","volume":"89","author":"T Yang","year":"2017","unstructured":"Yang, T., Stavrakis, S. & deMello, A. A High-Sensitivity, Integrated Absorbance and Fluorescence Detection Scheme for Probing Picoliter-Volume Droplets in Segmented Flows. Anal Chem 89, 12880\u201312887, https:\/\/doi.org\/10.1021\/acs.analchem.7b03526 (2017).","journal-title":"Anal Chem"},{"key":"63620_CR28","doi-asserted-by":"publisher","first-page":"14494","DOI":"10.1038\/srep14494","volume":"5","author":"H Cai","year":"2015","unstructured":"Cai, H. et al. Optofluidic analysis system for amplification-free, direct detection of Ebola infection. Sci Rep 5, 14494\u201314494, https:\/\/doi.org\/10.1038\/srep14494 (2015).","journal-title":"Sci Rep"},{"key":"63620_CR29","doi-asserted-by":"publisher","first-page":"2827","DOI":"10.1021\/acsnano.5b07948","volume":"10","author":"SM Scherr","year":"2016","unstructured":"Scherr, S. M. et al. Real-Time Capture and Visualization of Individual Viruses in Complex Media. ACS Nano 10, 2827\u20132833, https:\/\/doi.org\/10.1021\/acsnano.5b07948 (2016).","journal-title":"ACS Nano"},{"key":"63620_CR30","doi-asserted-by":"publisher","first-page":"6641","DOI":"10.1021\/ac201587a","volume":"83","author":"H Zhu","year":"2011","unstructured":"Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O. & Ozcan, A. Optofluidic fluorescent imaging cytometry on a cell phone. Anal Chem 83, 6641\u20136647, https:\/\/doi.org\/10.1021\/ac201587a (2011).","journal-title":"Anal Chem"},{"key":"63620_CR31","doi-asserted-by":"publisher","first-page":"464","DOI":"10.6028\/jres.121.024","volume":"121","author":"KC Balram","year":"2016","unstructured":"Balram, K. C. et al. The Nanolithography Toolbox. J. Res. Natl. Inst. Stand. 121, 464\u2013475, https:\/\/doi.org\/10.6028\/jres.121.024 (2016).","journal-title":"The Nanolithography Toolbox. J. Res. Natl. Inst. Stand."},{"key":"63620_CR32","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s10404-018-2125-6","volume":"22","author":"I Gablech","year":"2018","unstructured":"Gablech, I. et al. Fabrication of buried microfluidic channels with observation windows using femtosecond laser photoablation and parylene-C coating. Microfluid Nanofluid 22, 105 (2018).","journal-title":"Microfluid Nanofluid"},{"key":"63620_CR33","doi-asserted-by":"publisher","first-page":"2459","DOI":"10.1116\/1.1526356","volume":"20","author":"B Ilic","year":"2002","unstructured":"Ilic, B., Czaplewski, D., Zalalutdinov, M., Schmidt, B. & Craighead, H. Fabrication of flexible polymer tubes for micro and nanofluidic applications. Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena 20, 2459\u20132465 (2002).","journal-title":"Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena"},{"key":"63620_CR34","unstructured":"Laerme, F., Schilp, A., Funk, K. & Offenberg, M. In Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No. 99CH36291). 211\u2013216 (IEEE)."},{"key":"63620_CR35","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1002\/smll.200701317","volume":"4","author":"M Reismann","year":"2008","unstructured":"Reismann, M., Bretschneider, J. C., Plessen, G. V. & Simon, U. Reversible Photothermal Melting of DNA in DNA\u2013Gold-Nanoparticle Networks. Small 4, 607\u2013610, https:\/\/doi.org\/10.1002\/smll.200701317 (2008).","journal-title":"Small"},{"key":"63620_CR36","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1007\/s10404-018-2066-0","volume":"22","author":"ER Castro","year":"2018","unstructured":"Castro, E. R. et al. Determination of dynamic contact angles within microfluidic devices. Microfluid Nanofluid 22, 51 (2018).","journal-title":"Microfluid Nanofluid"},{"key":"63620_CR37","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1063\/1.5016465","volume":"123","author":"V Svatos","year":"2018","unstructured":"Svatos, V., Gablech, I., Ilic, B. R., Pekarek, J. & Neuzil, P. In situ observation of carbon nanotube layer growth on microbolometers with substrates at ambient temperature. J. Appl. Phys 123, 7, https:\/\/doi.org\/10.1063\/1.5016465 (2018).","journal-title":"J. Appl. Phys"},{"key":"63620_CR38","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.infrared.2018.07.037","volume":"93","author":"V Svato\u0161","year":"2018","unstructured":"Svato\u0161, V., Gablech, I., Pek\u00e1rek, J., Klempa, J. & Neu\u017eil, P. Precise determination of thermal parameters of a microbolometer. Infrared Phys Techn 93, 286\u2013290 (2018).","journal-title":"Infrared Phys Techn"},{"key":"63620_CR39","doi-asserted-by":"publisher","DOI":"10.1007\/s10404-019-2308-9","volume":"24","author":"H Zhu","year":"2020","unstructured":"Zhu, H. et al. Heat transfer time determination based on DNA melting curve analysis. Microfluidics and Nanofluidics 24, 7 (2020).","journal-title":"Microfluidics and Nanofluidics"},{"key":"63620_CR40","doi-asserted-by":"publisher","first-page":"2818","DOI":"10.1039\/c005243d","volume":"10","author":"P Neuzil","year":"2010","unstructured":"Neuzil, P., Cheng, F., Soon, J. B. W., Qian, L. L. & Reboud, J. Non-contact fluorescent bleaching-independent method for temperature measurement in microfluidic systems based on DNA melting curves. Lab Chip 10, 2818\u20132821, https:\/\/doi.org\/10.1039\/c005243d (2010).","journal-title":"Lab Chip"},{"key":"63620_CR41","doi-asserted-by":"publisher","first-page":"e0118182","DOI":"10.1371\/journal.pone.0118182","volume":"10","author":"MS Bartsch","year":"2015","unstructured":"Bartsch, M. S. et al. The rotary zone thermal cycler: a low-power system enabling automated rapid PCR. PloS one 10, e0118182\u2013e0118182, https:\/\/doi.org\/10.1371\/journal.pone.0118182 (2015).","journal-title":"PloS one"},{"key":"63620_CR42","doi-asserted-by":"publisher","first-page":"133901","DOI":"10.1063\/1.2790806","volume":"91","author":"P Baaske","year":"2007","unstructured":"Baaske, P., Duhr, S. & Braun, D. Melting curve analysis in a snapshot. Applied Physics Letters 91, 133901 (2007).","journal-title":"Applied Physics Letters"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-63620-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-63620-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-63620-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T09:38:45Z","timestamp":1670319525000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-63620-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,24]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["63620"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-63620-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,24]]},"assertion":[{"value":"26 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6925"}}