{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T06:30:34Z","timestamp":1785306634730,"version":"3.55.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,15]],"date-time":"2020-06-15T00:00:00Z","timestamp":1592179200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,15]],"date-time":"2020-06-15T00:00:00Z","timestamp":1592179200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>X-ray fluoroscopy is a commonly applied diagnostic tool for morphological and functional evaluation of the intestine in clinical routine. Acquisition of repetitive X-ray images following oral or rectal application of iodine contrast agent visualizes the time dependent distribution of the contrast medium, and helps to detect for example leakages, tumors or functional disorders. However, movements of the intestine and air trapped inside usually prevent temporal subtraction imaging to be applied to fluoroscopy of the gastrointestinal tract. K-edge subtraction (KES) imaging would enable subtraction fluoroscopy because it allows for imaging of moving organs with little artefacts. Although KES imaging is a well established technique at synchrotron sources, this imaging method is not applied in clinical routine as it relies on brilliant synchrotron radiation. Recently emerging compact synchrotron X-ray sources could provide a quasi-monochromatic, high-flux X-ray beam and allow for the application of KES in a laboratory environment. Here, we present a filter-based dynamic KES approach at the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. Compared to conventional temporal subtraction X-ray radiography, our approach increases the contrast while reducing the generated image artefacts.<\/jats:p>","DOI":"10.1038\/s41598-020-66414-x","type":"journal-article","created":{"date-parts":[[2020,6,15]],"date-time":"2020-06-15T10:02:44Z","timestamp":1592215364000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Dynamic K-edge Subtraction Fluoroscopy at a Compact Inverse-Compton Synchrotron X-ray Source"],"prefix":"10.1038","volume":"10","author":[{"given":"Stephanie","family":"Kulpe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Dierolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benedikt","family":"G\u00fcnther","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Brantl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madleen","family":"Busse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Achterhold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Gleich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franz","family":"Pfeiffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Pfeiffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,15]]},"reference":[{"key":"66414_CR1","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1023\/A:1008074100927","volume":"31","author":"EHW Meijering","year":"1999","unstructured":"Meijering, E. H. W., Zuiderveld, K. J. & Viergever, M. A. X. A. Image Registration for Digital Subtraction Angiography. Int. J. Comput. Vis. 31, 227\u2013246 (1999).","journal-title":"Int. J. Comput. Vis."},{"key":"66414_CR2","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1378\/chest.84.1.68","volume":"84","author":"JM Tobis","year":"1983","unstructured":"Tobis, J. M., Nalcioglu, O. & Henry, W. L. Digital Subtraction Angiography. Chest 84, 63\u201386 (1983).","journal-title":"Chest"},{"key":"66414_CR3","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s10278-008-9108-1","volume":"22","author":"M Yamamoto","year":"2009","unstructured":"Yamamoto, M. et al. Development of Digital Subtraction Angiography for Coronary Artery. J. Digit. Imaging 22, 319\u2013325 (2009).","journal-title":"J. Digit. Imaging"},{"key":"66414_CR4","doi-asserted-by":"publisher","first-page":"1456","DOI":"10.1007\/s00261-016-0702-2","volume":"41","author":"S Winklhofer","year":"2016","unstructured":"Winklhofer, S. et al. Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study. Abdom Radiol (NY) 41, 1456\u20131465 (2016).","journal-title":"Abdom Radiol (NY)"},{"key":"66414_CR5","doi-asserted-by":"publisher","first-page":"437","DOI":"10.3109\/00016925309136730","volume":"39","author":"B Jacobson","year":"1953","unstructured":"Jacobson, B. Dichromatic Absorption Radiography. Dichromography. Acta Radiol. 39, 437\u2013452 (1953).","journal-title":"Acta Radiol."},{"key":"66414_CR6","doi-asserted-by":"publisher","first-page":"3291","DOI":"10.1088\/0031-9155\/49\/14\/019","volume":"49","author":"A Sarnelli","year":"2004","unstructured":"Sarnelli, A. et al. K-edge digital subtraction imaging based on a dichromatic and compact x-ray source. Phys. Medicine Biol. 49, 3291\u20133305 (2004).","journal-title":"Phys. Medicine Biol."},{"key":"66414_CR7","first-page":"218","volume":"7","author":"BD Arhatari","year":"2017","unstructured":"Arhatari, B. D., Gureyev, T. E. & Abbey, B. Elemental Contrast X-ray Tomography Using Ross Filter Pairs with a Polychromatic Laboratory Source. Sci. Reports 7, 218 (2017).","journal-title":"Sci. Reports"},{"key":"66414_CR8","doi-asserted-by":"publisher","first-page":"4679","DOI":"10.1088\/0031-9155\/52\/15\/020","volume":"52","author":"E Roessl","year":"2007","unstructured":"Roessl, E. & Proksa, R. K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors. Phys. Medicine Biol. 52, 4679\u20134696 (2007).","journal-title":"Phys. Medicine Biol."},{"key":"66414_CR9","doi-asserted-by":"publisher","first-page":"4031","DOI":"10.1088\/0031-9155\/53\/15\/002","volume":"53","author":"JP Schlomka","year":"2008","unstructured":"Schlomka, J. P. et al. Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. Phys. Medicine Biol. 53, 4031\u20134047 (2008).","journal-title":"Phys. Medicine Biol."},{"key":"66414_CR10","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1088\/0031-9155\/53\/5\/020","volume":"53","author":"PM Shikhaliev","year":"2008","unstructured":"Shikhaliev, P. M. Computed tomography with energy-resolved detection: a feasibility study. Phys. Medicine Biol. 53, 1475\u20131495 (2008).","journal-title":"Phys. Medicine Biol."},{"key":"66414_CR11","doi-asserted-by":"publisher","first-page":"C04010","DOI":"10.1088\/1748-0221\/10\/04\/C04010","volume":"10","author":"A Vincenzi","year":"2015","unstructured":"Vincenzi, A. et al. Energy characterization of Pixirad-1 photon counting detector system. J. Instrumentation 10, C04010 (2015).","journal-title":"J. Instrumentation"},{"key":"66414_CR12","doi-asserted-by":"publisher","unstructured":"Pani, S. et al. Optimization of K-edge subtraction imaging using a pixellated spectroscopic detector. IEEE Nucl. Sci. Symp. Conf. Rec. 3063\u20133066, https:\/\/doi.org\/10.1109\/NSSMIC.2012.6551700 (2012).","DOI":"10.1109\/NSSMIC.2012.6551700"},{"key":"66414_CR13","first-page":"15979","volume":"5","author":"CK Egan","year":"2015","unstructured":"Egan, C. K. et al. 3D chemical imaging in the laboratory by hyperspectral X-ray computed tomography. Sci. Reports 5, 15979 (2015).","journal-title":"Sci. Reports"},{"key":"66414_CR14","first-page":"27","volume":"97","author":"E Rubenstein","year":"1986","unstructured":"Rubenstein, E. et al. Synchrotron Radiation for Transvenous Coronary Angiography. Trans. Am. Clin. Clim. Assoc. 97, 27\u201331 (1986).","journal-title":"Trans. Am. Clin. Clim. Assoc."},{"key":"66414_CR15","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/0079-6107(95)00003-6","volume":"63","author":"W-R Dix","year":"1995","unstructured":"Dix, W.-R. Intravenous coronary angiography with synchrotron radiation. Prog. Biophys. Mol. Biol. 63, 159\u2013191 (1995).","journal-title":"Prog. Biophys. Mol. Biol."},{"key":"66414_CR16","doi-asserted-by":"publisher","first-page":"L39","DOI":"10.1088\/0031-9155\/45\/9\/102","volume":"45","author":"H Elleaume","year":"2000","unstructured":"Elleaume, H. et al. First human transvenous coronary angiography at the European Synchrotron Radiation Facility. Phys. Med. Biol. 45, L39\u2013L43 (2000).","journal-title":"Phys. Med. Biol."},{"key":"66414_CR17","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1093\/eurheartj\/ehi165","volume":"26","author":"B Bertrand","year":"2005","unstructured":"Bertrand, B. et al. Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty. Eur. Hear. J. 26, 1284\u20131291 (2005).","journal-title":"Eur. Hear. J."},{"key":"66414_CR18","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1088\/0031-9155\/42\/2\/009","volume":"42","author":"FA Dilmanian","year":"1997","unstructured":"Dilmanian, F. A. et al. Single- and dual-energy CT with monochromatic synchrotron x-rays. Phys. Medicine Biol. 42, 371\u2013387 (1997).","journal-title":"Medicine Biol."},{"key":"66414_CR19","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/j.ejrad.2010.07.002","volume":"79","author":"E Sch\u00fcltke","year":"2011","unstructured":"Sch\u00fcltke, E. et al. Dual energy CT at the synchrotron: A piglet model for neurovascular research. Eur. J. Radiol. 79, 323\u2013327 (2011).","journal-title":"Eur. J. Radiol."},{"key":"66414_CR20","doi-asserted-by":"publisher","first-page":"5777","DOI":"10.1088\/0031-9155\/57\/18\/5777","volume":"57","author":"DM Cooper","year":"2012","unstructured":"Cooper, D. M. et al. Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging. Phys. Medicine Biol. 57, 5777\u20135786 (2012).","journal-title":"Phys. Medicine Biol."},{"key":"66414_CR21","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1107\/S160057751401697X","volume":"21","author":"S Strengell","year":"2014","unstructured":"Strengell, S. et al. Radiation dose and image quality in K-edge subtraction computed tomography of lung in vivo. J. Synchrotron Radiat. 21, 1305\u20131313 (2014).","journal-title":"J. Synchrotron Radiat."},{"key":"66414_CR22","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ejmp.2018.04.389","volume":"49","author":"W Thomlinson","year":"2018","unstructured":"Thomlinson, W., Elleaume, H., Porra, L. & Suortti, P. K-edge subtraction synchrotron X-ray imaging in bio-medical research. Phys. Medica 49, 58\u201376 (2018).","journal-title":"Phys. Medica"},{"key":"66414_CR23","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.nima.2005.03.071","volume":"548","author":"E Sch\u00fcltke","year":"2005","unstructured":"Sch\u00fcltke, E. et al. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography. Nucl. Instruments Methods Phys. Res. A 548, 84\u201387 (2005).","journal-title":"Nucl. Instruments Methods Phys. Res. A"},{"key":"66414_CR24","doi-asserted-by":"publisher","first-page":"3369","DOI":"10.1088\/0031-9155\/47\/18\/307","volume":"47","author":"H Elleaume","year":"2002","unstructured":"Elleaume, H., Charvet, A. M., Corde, S., Est\u00e8ve, F. & Le Bas, J. F. Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams: comparison of K-edge versus temporal subtraction. Phys. Med. Biol. 47, 3369\u20133385 (2002).","journal-title":"Phys. Med. Biol."},{"key":"66414_CR25","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/00004424-197907000-00002","volume":"14","author":"TL Houk","year":"1979","unstructured":"Houk, T. L. et al. Real-Time Digital K-Edge Subtraction Fluoroscopy. Investig. Radiol. 14, 270\u2013278 (1979).","journal-title":"Investig. Radiol."},{"key":"66414_CR26","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1103\/PhysRevLett.80.976","volume":"80","author":"Z Huang","year":"1998","unstructured":"Huang, Z. & Ruth, R. D. Laser-Electron Storage Ring. Phys. Rev. Lett. 80, 976\u2013979 (1998).","journal-title":"Phys. Rev. Lett."},{"key":"66414_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.nimb.2013.10.078","volume":"331","author":"M Jacquet","year":"2014","unstructured":"Jacquet, M. High intensity compact Compton X-ray sources: Challenges and potential of applications. Nucl. Instruments Methods Phys. Res. Sect. B 331, 1\u20135 (2014).","journal-title":"Nucl. Instruments Methods Phys. Res. Sect. B"},{"key":"66414_CR28","unstructured":"Bacci, A. et al. Status of the STAR Project. Proc. IPAC2016, Busan, Korea TUPOW004 (2016)."},{"key":"66414_CR29","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1107\/S160057751600967X","volume":"23","author":"E Eggl","year":"2016","unstructured":"Eggl, E. et al. The Munich Compact Light Source: initial performance measures. J. Synchrotron Radiat. 23, 91\u2013100 (2016).","journal-title":"J. Synchrotron Radiat."},{"key":"66414_CR30","doi-asserted-by":"crossref","unstructured":"Eggl, E. et al. Mono-Energy Coronary Angiography with a Compact Synchtrotron Source. Sci. Reports 7, 42211, (2017). 1506.01997.","DOI":"10.1038\/srep42211"},{"key":"66414_CR31","doi-asserted-by":"publisher","first-page":"e0208446","DOI":"10.1371\/journal.pone.0208446","volume":"13","author":"S Kulpe","year":"2018","unstructured":"Kulpe, S. et al. K-edge subtraction imaging for coronary angiography with a compact synchrotron X-ray source. PloS ONE 13, e0208446 (2018).","journal-title":"PloS ONE"},{"key":"66414_CR32","first-page":"13332","volume":"9","author":"S Kulpe","year":"2019","unstructured":"Kulpe, S. et al. K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source. Sci. Reports 9, 13332 (2019).","journal-title":"Sci. Reports"},{"key":"66414_CR33","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.amsu.2016.01.001","volume":"6","author":"JV Thomas","year":"2016","unstructured":"Thomas, J. V. et al. Gadoxetate Disodium enhanced spectral dual-energy CT for evaluation of cholangiocarcinoma: Preliminary data. Annals Medicine Surg. 6, 17\u201322 (2016).","journal-title":"Annals Medicine Surg."},{"key":"66414_CR34","doi-asserted-by":"publisher","first-page":"3677","DOI":"10.1007\/s00330-017-4737-8","volume":"27","author":"RW van Hamersvelt","year":"2017","unstructured":"van Hamersvelt, R. W. et al. Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study. Eur. Radiol. 27, 3677\u20133686 (2017).","journal-title":"Eur. Radiol."},{"key":"66414_CR35","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/S0741-5214(03)00315-X","volume":"38","author":"AD Sam","year":"2003","unstructured":"Sam, A. D. et al. Safety of gadolinium contrast angiography in patients with chronic renal insufficiency. J. Vasc. Surg. 38, 313\u2013318 (2003).","journal-title":"J. Vasc. Surg."},{"key":"66414_CR36","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1177\/0003319707303640","volume":"58","author":"T Sayin","year":"2007","unstructured":"Sayin, T., Turhan, S., Aky\u00fcrek, O. & Kilickap, M. Gadolinium:nonionic contrast media (1:1) coronary angiography in patients with impaired renal function. Angiology 58, 561\u20134 (2007).","journal-title":"Angiology"},{"key":"66414_CR37","unstructured":"Variola, A. The ThomX project. Proc. IPAC2011, San Sebastian, Spain WEOAA01 (2011)."},{"key":"66414_CR38","doi-asserted-by":"crossref","unstructured":"Faillace, L. et al. Status of compact inverse Compton sources in Italy: BriXS and STAR. Proc. SPIE Opt. Photonics 2019 1111005, (September 2019).","DOI":"10.1117\/12.2531168"},{"key":"66414_CR39","first-page":"1313","volume":"3","author":"K Achterhold","year":"2013","unstructured":"Achterhold, K. et al. Monochromatic computed tomography with a compact laser-driven X-ray source. Sci. Reports 3, 1313 (2013).","journal-title":"Sci. Reports"},{"key":"66414_CR40","doi-asserted-by":"publisher","unstructured":"Loewen, R. J. A Compact Light Source: Design and Technical Feasibility Study of a Laser-Electron Storage Ring X-ray Source. Ph.D. thesis, Standford University, https:\/\/doi.org\/10.2172\/826755 (2003).","DOI":"10.2172\/826755"},{"key":"66414_CR41","first-page":"312","volume":"24","author":"B G\u00fcnther","year":"2018","unstructured":"G\u00fcnther, B. et al. The Munich Compact Light Source: Flux Doubling and Source Position Stabilization At a Compact Inverse-Compton Synchrotron X-ray Source. Microsc. Microanal. 24, 312\u2013313 (2018).","journal-title":"Microsc. Microanal."},{"key":"66414_CR42","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/0168-9002(91)90026-M","volume":"301","author":"K Umetani","year":"1991","unstructured":"Umetani, K. et al. Iodine K-edge dual-energy imaging for subtraction angiography using synchrotron radiation and a 2-dimensional detector. Nucl. Instruments Methods Phys. Res. A 301, 579\u2013588 (1991).","journal-title":"Nucl. Instruments Methods Phys. Res. A"},{"key":"66414_CR43","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/0168-9002(93)91245-I","volume":"335","author":"K Umetani","year":"1993","unstructured":"Umetani, K. et al. Iodine filter imaging system for subtraction angiography using synchrotron radiation. Nucl. Instruments Methods Phys. Res. A 335, 569\u2013579 (1993).","journal-title":"Nucl. Instruments Methods Phys. Res. A"},{"key":"66414_CR44","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1364\/BOE.7.000079","volume":"7","author":"RP Murrie","year":"2016","unstructured":"Murrie, R. P., Paganin, D. M., Fouras, A. & Morgan, K. S. Phase contrast x-ray velocimetry of small animal lungs: optimising imaging rates. Biomed. Opt. Express 7, 79\u201392 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"66414_CR45","first-page":"6788","volume":"8","author":"R Gradl","year":"2018","unstructured":"Gradl, R. et al. In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source. Sci. Reports 8, 6788 (2018).","journal-title":"Sci. Reports"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66414-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66414-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66414-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T12:39:18Z","timestamp":1670330358000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66414-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,15]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["66414"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-66414-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,15]]},"assertion":[{"value":"5 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9612"}}