{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T19:30:47Z","timestamp":1790105447907,"version":"4.0.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,29]],"date-time":"2020-06-29T00:00:00Z","timestamp":1593388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,29]],"date-time":"2020-06-29T00:00:00Z","timestamp":1593388800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3\u20134 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54\u2009\u00b1\u200926\u2009mmHG vs 50\u2009\u00b1\u200934\u2009mmHg, P\u2009=\u20090.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61\u2009\u00b1\u200932\u2009mmHG vs 50\u2009\u00b1\u200934\u2009mmHg, P\u2009=\u20090.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r\u2009=\u2009\u22120.45, P\u2009=\u20090.01) and EOA (r\u2009=\u20090.54, P\u2009&lt;\u20090.01) but only with Doppler EOA (r\u2009=\u20090.45, P\u2009=\u20090.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r\u2009=\u20090.64, P\u2009=\u20090.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.<\/jats:p>","DOI":"10.1038\/s41598-020-66659-6","type":"journal-article","created":{"date-parts":[[2020,6,29]],"date-time":"2020-06-29T10:03:01Z","timestamp":1593424981000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":44,"title":["Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment"],"prefix":"10.1038","volume":"10","author":[{"given":"Gareth T.","family":"Archer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaa","family":"Elhawaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natasha","family":"Barker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Fidock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Rothman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. J.","family":"van der Geest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rod","family":"Hose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norman","family":"Briffa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian R.","family":"Hall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ever","family":"Grech","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malenka","family":"Bissell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdallah","family":"Al-Mohammad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas A.","family":"Treibel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew J.","family":"Swift","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James M.","family":"Wild","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pankaj","family":"Garg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,29]]},"reference":[{"key":"66659_CR1","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/S0140-6736(06)69208-8","volume":"368","author":"VT Nkomo","year":"2006","unstructured":"Nkomo, V. T. et al. Burden of valvular heart diseases: a population-based study. The Lancet 368, 1005\u20131011 (2006).","journal-title":"The Lancet"},{"key":"66659_CR2","unstructured":"Baumgartner, H. et al. 2017 ESC\/EACTS Guidelines for the Management of Valvular Heart Disease. Rev. Esp. Cardiol. Engl. Ed. 71, 110 (2018)."},{"key":"66659_CR3","doi-asserted-by":"publisher","first-page":"e57","DOI":"10.1016\/j.jacc.2014.02.536","volume":"63","author":"RA Nishimura","year":"2014","unstructured":"Nishimura, R. A. et al. 2014 AHA\/ACC Guideline for the Management of Patients With Valvular Heart Disease. J. Am. Coll. Cardiol. 63, e57\u2013e185 (2014).","journal-title":"J. Am. Coll. Cardiol."},{"key":"66659_CR4","doi-asserted-by":"crossref","unstructured":"Parameswaran, A. C., Reisner, D. & Amanullah, A. Discrepancy between gradients derived by cardiac catheterization and by Doppler echocardiography in aortic stenosis: how often does pressure recovery play a role? Echocardiogr. Mt. Kisco N 26, 1000\u20131005; quiz 999 (2009).","DOI":"10.1111\/j.1540-8175.2009.00909.x"},{"key":"66659_CR5","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.echo.2007.04.031","volume":"21","author":"DM Spevack","year":"2008","unstructured":"Spevack, D. M., Almuti, K., Ostfeld, R., Bello, R. & Gordon, G. M. Routine adjustment of Doppler echocardiographically derived aortic valve area using a previously derived equation to account for the effect of pressure recovery. J. Am. Soc. Echocardiogr. Off. Publ. Am. Soc. Echocardiogr. 21, 34\u201337 (2008).","journal-title":"J. Am. Soc. Echocardiogr. Off. Publ. Am. Soc. Echocardiogr."},{"key":"66659_CR6","doi-asserted-by":"crossref","first-page":"e005207","DOI":"10.1161\/CIRCIMAGING.116.005207","volume":"10","author":"Donati Fabrizio","year":"2017","unstructured":"Donati Fabrizio et al. Beyond Bernoulli. Circ. Cardiovasc. Imaging 10, e005207 (2017).","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"66659_CR7","doi-asserted-by":"crossref","unstructured":"Baumgartner, H. et al. Echocardiographic assessment of valve stenosis: EAE\/ASE recommendations for clinical practice. J. Am. Soc. Echocardiogr. Off. Publ. Am. Soc. Echocardiogr. 22, 1\u201323; quiz 101\u2013102 (2009).","DOI":"10.1016\/j.echo.2008.10.014"},{"key":"66659_CR8","unstructured":"Cardiovascular MR Manual. (Springer International Publishing, 2015)."},{"key":"66659_CR9","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1007\/s40134-016-0167-7","volume":"4","author":"RJ van der Geest","year":"2016","unstructured":"van der Geest, R. J. & Garg, P. Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI. Curr. Radiol. Rep. 4, 38 (2016).","journal-title":"Curr. Radiol. Rep."},{"key":"66659_CR10","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.crad.2016.01.011","volume":"71","author":"M Markl","year":"2016","unstructured":"Markl, M. et al. Advanced flow MRI: emerging techniques and applications. Clin. Radiol. 71, 779\u2013795 (2016).","journal-title":"Clin. Radiol."},{"key":"66659_CR11","doi-asserted-by":"publisher","unstructured":"Adriaans, B. P. et al. Clinical assessment of aortic valve stenosis: Comparison between 4D flow MRI and transthoracic echocardiography. J. Magn. Reson. Imaging JMRI https:\/\/doi.org\/10.1002\/jmri.26847 (2019).","DOI":"10.1002\/jmri.26847"},{"key":"66659_CR12","doi-asserted-by":"publisher","first-page":"G9","DOI":"10.1530\/ERP-14-0079","volume":"2","author":"G Wharton","year":"2015","unstructured":"Wharton, G. et al. A minimum dataset for a standard adult transthoracic echocardiogram: a guideline protocol from the British Society of Echocardiography. Echo Res. Pract. 2, G9\u2013G24 (2015).","journal-title":"Echo Res. Pract."},{"key":"66659_CR13","doi-asserted-by":"publisher","first-page":"368","DOI":"10.3109\/00016925309136722","volume":"39","author":"SI Seldinger","year":"1953","unstructured":"Seldinger, S. I. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol. 39, 368\u2013376 (1953).","journal-title":"Acta Radiol."},{"key":"66659_CR14","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1016\/j.amjcard.2013.02.033","volume":"111","author":"R Chopard","year":"2013","unstructured":"Chopard, R. et al. Invasive assessment of doubtful aortic stenosis by measuring simultaneous transaortic gradient with a pressure wire. Am. J. Cardiol. 111, 1772\u20131777 (2013).","journal-title":"Am. J. Cardiol."},{"key":"66659_CR15","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1002\/jmri.25746","volume":"47","author":"P Garg","year":"2017","unstructured":"Garg, P. et al. Comparison of fast acquisition strategies in whole-heart four-dimensional flow cardiac MR: Two-center, 1.5 Tesla, phantom and in vivo validation study. J. Magn. Reson. Imaging 47, 272\u2013281 (2017).","journal-title":"J. Magn. Reson. Imaging"},{"key":"66659_CR16","first-page":"1115","volume":"2018","author":"J-M Zhang","year":"2018","unstructured":"Zhang, J.-M. et al. Comparison of Image Acquisition Techniques in Four-Dimensional Flow Cardiovascular MR on 3 Tesla in Volunteers and Tetralogy of Fallot Patients. Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Annu. Conf. 2018, 1115\u20131118 (2018).","journal-title":"Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Annu. Conf."},{"key":"66659_CR17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1002\/mrm.24885","volume":"72","author":"R Lorenz","year":"2014","unstructured":"Lorenz, R. et al. Influence of Eddy Current, Maxwell and Gradient Field Corrections on 3D Flow Visualization of 3D CINE PC-MRI Data. Magn. Reson. Med. Off. J. Soc. Magn. Reson. Med. Soc. Magn. Reson. Med. 72, 33\u201340 (2014).","journal-title":"Magn. Reson. Med. Off. J. Soc. Magn. Reson. Med. Soc. Magn. Reson. Med."},{"key":"66659_CR18","doi-asserted-by":"publisher","first-page":"e0149930","DOI":"10.1371\/journal.pone.0149930","volume":"11","author":"ME MacDonald","year":"2016","unstructured":"MacDonald, M. E., Forkert, N. D., Pike, G. B. & Frayne, R. Phase Error Correction in Time-Averaged 3D Phase Contrast Magnetic Resonance Imaging of the Cerebral Vasculature. PLOS ONE 11, e0149930 (2016).","journal-title":"PLOS ONE"},{"key":"66659_CR19","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/1532-429X-15-35","volume":"15","author":"J Schulz-Menger","year":"2013","unstructured":"Schulz-Menger, J. et al. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing. J. Cardiovasc. Magn. Reson. 15, 35 (2013).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"66659_CR20","unstructured":"Ghiglia, D. & Pritt, M. Two-Dimensional Phase Unwrapping: Theory, Algorithms, and Software. (1998)."},{"key":"66659_CR21","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1186\/s12968-015-0172-7","volume":"17","author":"KS Nayak","year":"2015","unstructured":"Nayak, K. S. et al. Cardiovascular magnetic resonance phase contrast imaging. J. Cardiovasc. Magn. Reson. 17, 71 (2015).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"66659_CR22","doi-asserted-by":"crossref","unstructured":"ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: guidelines for the six-minute walk test. Am. J. Respir. Crit. Care Med. 166, 111\u2013117 (2002).","DOI":"10.1164\/ajrccm.166.1.at1102"},{"key":"66659_CR23","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1016\/S0735-1097(99)00066-2","volume":"33","author":"H Baumgartner","year":"1999","unstructured":"Baumgartner, H., Stefenelli, T., Niederberger, J., Schima, H. & Maurer, G. \u2018Overestimation\u2019 of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery. J. Am. Coll. Cardiol. 33, 1655\u20131661 (1999).","journal-title":"J. Am. Coll. Cardiol."},{"key":"66659_CR24","first-page":"1002","volume":"93","author":"AE Abbas","year":"2019","unstructured":"Abbas, A. E. & Pibarot, P. Hemodynamic characterization of aortic stenosis states. Catheter. Cardiovasc. Interv. Off. J. Soc. Card. Angiogr. Interv. 93, 1002\u20131023 (2019).","journal-title":"Off. J. Soc. Card. Angiogr. Interv."},{"key":"66659_CR25","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1016\/j.jvs.2005.07.014","volume":"42","author":"EYL Lui","year":"2005","unstructured":"Lui, E. Y. L., Steinman, A. H., Cobbold, R. S. C. & Johnston, K. W. Human factors as a source of error in peak Doppler velocity measurement. J. Vasc. Surg. 42, 972\u2013979 (2005).","journal-title":"J. Vasc. Surg."},{"key":"66659_CR26","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1002\/jmri.24847","volume":"42","author":"BD Allen","year":"2015","unstructured":"Allen, B. D. et al. Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve. J. Magn. Reson. Imaging JMRI 42, 954\u2013963 (2015).","journal-title":"J. Magn. Reson. Imaging JMRI"},{"key":"66659_CR27","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1002\/jmri.23793","volume":"37","author":"S Nordmeyer","year":"2013","unstructured":"Nordmeyer, S. et al. Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow. J. Magn. Reson. Imaging JMRI 37, 208\u2013216 (2013).","journal-title":"J. Magn. Reson. Imaging JMRI"},{"key":"66659_CR28","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1007\/s00247-014-3246-z","volume":"45","author":"M Gabbour","year":"2015","unstructured":"Gabbour, M. et al. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography. Pediatr. Radiol. 45, 804\u201313 (2015).","journal-title":"Pediatr. Radiol."},{"key":"66659_CR29","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1161\/CIRCULATIONAHA.116.026349","volume":"136","author":"O Abdul-Jawad Altisent","year":"2017","unstructured":"Abdul-Jawad Altisent, O. et al. Predictors and Association With Clinical Outcomes of the Changes in Exercise Capacity After Transcatheter Aortic Valve Replacement. Circulation 136, 632\u2013643 (2017).","journal-title":"Circulation"},{"key":"66659_CR30","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.jtcvs.2010.08.084","volume":"142","author":"A Ali","year":"2011","unstructured":"Ali, A. et al. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival. J. Thorac. Cardiovasc. Surg. 142, 285\u2013291 (2011).","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"66659_CR31","doi-asserted-by":"crossref","unstructured":"Kanski, M. et al. Whole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use: a head-to-head comparison. BMC Med. Imaging 15 (2015).","DOI":"10.1186\/s12880-015-0061-4"},{"key":"66659_CR32","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/0002-9149(91)90939-I","volume":"67","author":"JG Dumesnil","year":"1991","unstructured":"Dumesnil, J. G. & Yoganathan, A. P. Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas. Am. J. Cardiol. 67, 1268\u20131272 (1991).","journal-title":"Am. J. Cardiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66659-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66659-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66659-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T12:51:32Z","timestamp":1670331092000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-66659-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,29]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["66659"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-66659-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,29]]},"assertion":[{"value":"24 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10569"}}