{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T03:30:08Z","timestamp":1775014208741,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T00:00:00Z","timestamp":1592870400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T00:00:00Z","timestamp":1592870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The arterial connections in the Circle of Willis are a central source of collateral blood flow and play an important role in pathologies such as stroke and mental illness. Analysis of the Circle of Willis and its variants can shed light on optimal methods of diagnosis, treatment planning, surgery, and quantification of outcomes. We developed an automated, standardized, objective, and high-throughput approach for categorizing and quantifying the Circle of Willis vascular anatomy using magnetic resonance angiography images. This automated algorithm for processing of MRA images isolates and automatically identifies key features of the cerebral vasculature such as branching of the internal intracranial internal carotid artery and the basilar artery. Subsequently, physical features of the segments of the anterior cerebral artery were acquired on a sample and intra-patient comparisons were made. We demonstrate the feasibility of using our approach to automatically classify important structures of the Circle of Willis and extract biomarkers from cerebrovasculature. Automated image analysis can provide clinically-relevant vascular features such as aplastic arteries, stenosis, aneurysms, and vessel caliper for endovascular procedures. The developed algorithm could facilitate clinical studies by supporting high-throughput automated analysis of the cerebral vasculature.<\/jats:p>","DOI":"10.1038\/s41598-020-67225-w","type":"journal-article","created":{"date-parts":[[2020,6,23]],"date-time":"2020-06-23T10:02:51Z","timestamp":1592906571000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Quantitative Analysis of the Cerebral Vasculature on Magnetic Resonance Angiography"],"prefix":"10.1038","volume":"10","author":[{"given":"Pulak","family":"Goswami","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mia K.","family":"Markey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven J.","family":"Warach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adrienne N.","family":"Dula","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,6,23]]},"reference":[{"key":"67225_CR1","doi-asserted-by":"publisher","first-page":"2423","DOI":"10.7860\/JCDR\/2013\/6580.3563","volume":"7","author":"S Iqbal","year":"2013","unstructured":"Iqbal, S. A comprehensive study of the anatomical variations of the circle of willis in adult human brains. J Clin Diagn Res 7, 2423\u20132427, https:\/\/doi.org\/10.7860\/JCDR\/2013\/6580.3563 (2013).","journal-title":"J Clin Diagn Res"},{"key":"67225_CR2","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.clinimag.2014.01.007","volume":"38","author":"RK Arjal","year":"2014","unstructured":"Arjal, R. K., Zhu, T. & Zhou, Y. The study of fetal-type posterior cerebral circulation on multislice CT angiography and its influence on cerebral ischemic strokes. Clin Imaging 38, 221\u2013225, https:\/\/doi.org\/10.1016\/j.clinimag.2014.01.007 (2014).","journal-title":"Clin Imaging"},{"key":"67225_CR3","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1007\/s00234-015-1589-2","volume":"57","author":"T van Seeters","year":"2015","unstructured":"van Seeters, T. et al. Completeness of the circle of Willis and risk of ischemic stroke in patients without cerebrovascular disease. Neuroradiology 57, 1247\u20131251, https:\/\/doi.org\/10.1007\/s00234-015-1589-2 (2015).","journal-title":"Neuroradiology"},{"key":"67225_CR4","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.jns.2018.09.013","volume":"394","author":"Y Berthezene","year":"2018","unstructured":"Berthezene, Y. et al. Collateral circulation assessment within the 4.5\u2009h time window in patients with and without DWI\/FLAIR MRI mismatch. J Neurol Sci 394, 94\u201398, https:\/\/doi.org\/10.1016\/j.jns.2018.09.013 (2018).","journal-title":"J Neurol Sci"},{"key":"67225_CR5","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.jcrc.2012.08.018","volume":"28","author":"YM Chuang","year":"2013","unstructured":"Chuang, Y. M. et al. Configuration of the circle of Willis is associated with less symptomatic intracerebral hemorrhage in ischemic stroke patients treated with intravenous thrombolysis. J Crit Care 28, 166\u2013172, https:\/\/doi.org\/10.1016\/j.jcrc.2012.08.018 (2013).","journal-title":"J Crit Care"},{"key":"67225_CR6","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1109\/TMI.2013.2259595","volume":"32","author":"H Bogunovic","year":"2013","unstructured":"Bogunovic, H., Pozo, J. M., Cardenes, R., San Roman, L. & Frangi, A. F. Anatomical labeling of the Circle of Willis using maximum a posteriori probability estimation. IEEE Trans Med Imaging 32, 1587\u20131599, https:\/\/doi.org\/10.1109\/TMI.2013.2259595 (2013).","journal-title":"IEEE Trans Med Imaging"},{"key":"67225_CR7","doi-asserted-by":"publisher","first-page":"4865","DOI":"10.1109\/IEMBS.2006.260438","volume":"1","author":"Y Uchiyama","year":"2006","unstructured":"Uchiyama, Y. et al. Automated classification of cerebral arteries in MRA images and its application to maximum intensity projection. Conf Proc IEEE Eng Med Biol Soc 1, 4865\u20134868, https:\/\/doi.org\/10.1109\/IEMBS.2006.260438 (2006).","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"67225_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-47368-1","volume":"9","author":"H Kandil","year":"2019","unstructured":"Kandil, H. et al. A Novel Framework for Early Detection of Hypertension using Magnetic Resonance Angiography. Sci Rep 9, 11105, https:\/\/doi.org\/10.1038\/s41598-019-47368-1 (2019).","journal-title":"Sci Rep"},{"key":"67225_CR9","doi-asserted-by":"publisher","first-page":"102107","DOI":"10.1016\/j.nicl.2019.102107","volume":"25","author":"H Kandil","year":"2020","unstructured":"Kandil, H. et al. A novel computer-aided diagnosis system for the early detection of hypertension based on cerebrovascular alterations. Neuroimage Clin 25, 102107, https:\/\/doi.org\/10.1016\/j.nicl.2019.102107 (2020).","journal-title":"Neuroimage Clin"},{"key":"67225_CR10","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/s0001-2998(78)80014-2","volume":"8","author":"CE Metz","year":"1978","unstructured":"Metz, C. E. Basic principles of ROC analysis. Semin Nucl Med 8, 283\u2013298, https:\/\/doi.org\/10.1016\/s0001-2998(78)80014-2 (1978).","journal-title":"Semin Nucl Med"},{"key":"67225_CR11","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.1109\/TMI.2005.857653","volume":"24","author":"J Tschirren","year":"2005","unstructured":"Tschirren, J., McLennan, G., Palagyi, K., Hoffman, E. A. & Sonka, M. Matching and anatomical labeling of human airway tree. IEEE Trans Med Imaging 24, 1540\u20131547, https:\/\/doi.org\/10.1109\/TMI.2005.857653 (2005).","journal-title":"IEEE Trans Med Imaging"},{"key":"67225_CR12","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.mri.2012.07.008","volume":"31","author":"ND Forkert","year":"2013","unstructured":"Forkert, N. D. et al. 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights. Magn Reson Imaging 31, 262\u2013271, https:\/\/doi.org\/10.1016\/j.mri.2012.07.008 (2013).","journal-title":"Magn Reson Imaging"},{"key":"67225_CR13","doi-asserted-by":"publisher","first-page":"2019","DOI":"10.1109\/TBME.2012.2196434","volume":"59","author":"A El-Baz","year":"2012","unstructured":"El-Baz, A. et al. Precise segmentation of 3-D magnetic resonance angiography. IEEE Trans Biomed Eng 59, 2019\u20132029, https:\/\/doi.org\/10.1109\/TBME.2012.2196434 (2012).","journal-title":"IEEE Trans Biomed Eng"},{"key":"67225_CR14","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.media.2004.11.009","volume":"10","author":"MS Hassouna","year":"2006","unstructured":"Hassouna, M. S., Farag, A. A., Hushek, S. & Moriarty, T. Cerebrovascular segmentation from TOF using stochastic models. Med Image Anal 10, 2\u201318, https:\/\/doi.org\/10.1016\/j.media.2004.11.009 (2006).","journal-title":"Med Image Anal"},{"key":"67225_CR15","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.jneumeth.2014.12.003","volume":"241","author":"R Wang","year":"2015","unstructured":"Wang, R. et al. Threshold segmentation algorithm for automatic extraction of cerebral vessels from brain magnetic resonance angiography images. J Neurosci Methods 241, 30\u201336, https:\/\/doi.org\/10.1016\/j.jneumeth.2014.12.003 (2015).","journal-title":"J Neurosci Methods"},{"key":"67225_CR16","doi-asserted-by":"publisher","first-page":"97","DOI":"10.3389\/fnins.2019.00097","volume":"13","author":"M Livne","year":"2019","unstructured":"Livne, M. et al. A U-Net Deep Learning Framework for High Performance Vessel Segmentation in Patients With Cerebrovascular Disease. Front Neurosci 13, 97, https:\/\/doi.org\/10.3389\/fnins.2019.00097 (2019).","journal-title":"Front Neurosci"},{"key":"67225_CR17","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.media.2016.03.006","volume":"32","author":"D Robben","year":"2016","unstructured":"Robben, D. et al. Simultaneous segmentation and anatomical labeling of the cerebral vasculature. Med Image Anal 32, 201\u2013215, https:\/\/doi.org\/10.1016\/j.media.2016.03.006 (2016).","journal-title":"Med Image Anal"},{"key":"67225_CR18","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.cmpb.2018.02.001","volume":"158","author":"S Moccia","year":"2018","unstructured":"Moccia, S., De Momi, E., El Hadji, S. & Mattos, L. S. Blood vessel segmentation algorithms - Review of methods, datasets and evaluation metrics. Comput Methods Programs Biomed 158, 71\u201391, https:\/\/doi.org\/10.1016\/j.cmpb.2018.02.001 (2018).","journal-title":"Comput Methods Programs Biomed"},{"key":"67225_CR19","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1007\/978-3-642-15558-1_52","volume":"6313","author":"MWK Law","year":"2010","unstructured":"Law, M. W. K. & Chung, A. C. S. An Oriented Flux Symmetry Based Active Contour Model for Three Dimensional Vessel Segmentation. Computer Vision-Eccv 2010, Pt Iii 6313, 720\u2013734 (2010).","journal-title":"Computer Vision-Eccv 2010, Pt Iii"},{"key":"67225_CR20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1002\/hbm.10062","volume":"17","author":"SM Smith","year":"2002","unstructured":"Smith, S. M. Fast robust automated brain extraction. Hum Brain Mapp 17, 143\u2013155, https:\/\/doi.org\/10.1002\/hbm.10062 (2002).","journal-title":"Hum Brain Mapp"},{"key":"67225_CR21","unstructured":"R: A language and environment for statistical computing. (R Foundation for Statistical Computing, Vienna, Austria, 2013)."},{"key":"67225_CR22","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/42.906424","volume":"20","author":"Y Zhang","year":"2001","unstructured":"Zhang, Y., Brady, M. & Smith, S. Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm. IEEE Trans Med Imaging 20, 45\u201357, https:\/\/doi.org\/10.1109\/42.906424 (2001).","journal-title":"IEEE Trans Med Imaging"},{"key":"67225_CR23","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","volume":"17","author":"M Jenkinson","year":"2002","unstructured":"Jenkinson, M., Bannister, P., Brady, M. & Smith, S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage 17, 825\u2013841 (2002).","journal-title":"Neuroimage"},{"key":"67225_CR24","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1109\/83.902291","volume":"10","author":"TF Chan","year":"2001","unstructured":"Chan, T. F. & Vese, L. A. Active contours without edges. Ieee T Image Process 10, 266\u2013277, https:\/\/doi.org\/10.1109\/83.902291 (2001).","journal-title":"Ieee T Image Process"},{"key":"67225_CR25","unstructured":"Skeleton3D (Matlab File Exchange, 2018)."},{"key":"67225_CR26","unstructured":"Skel2Graph 3D (Matlab File Exchange, 2018)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-67225-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-67225-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-67225-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T12:19:22Z","timestamp":1670329162000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-67225-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,23]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["67225"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-67225-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,23]]},"assertion":[{"value":"6 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10227"}}