{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T17:23:01Z","timestamp":1775841781091,"version":"3.50.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T00:00:00Z","timestamp":1594598400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T00:00:00Z","timestamp":1594598400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"crossref","award":["17hk0102045h0001"],"award-info":[{"award-number":["17hk0102045h0001"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Early detection of compromised circulation is essential for postoperative monitoring of free flap. Hourly clinical check-ups such as inspection and palpation still result in a delay in detection. Conversely, optical reflection and temperature measurement are useful alternatives for detecting blood circulation. However, conventional methods that verify ischemia and congestion within a short period have not been reported. In this study, we measured short-term changes in optical reflection and temperature in a rat flap using a wearable flexible sensor probe previously developed in our laboratory. Five ischemia and five congestion groin flap models were measured using a sensor probe and reference devices. Curve fitting was performed on transition signals to evaluate changes in signals and their time constants. The optical reflection signal decreased after venous ligation and increased after arterial ligation. The parameters of the fitted curves indicate a significant difference between congestion and ischemia at <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01 (probability value), which was detected within a few minutes after ligation. However, insufficient significance was observed in the temperature signal. Our method gives supporting information to verify ischemia and congestion, and has the potential to rapidly detect compromised circulation.\n<\/jats:p>","DOI":"10.1038\/s41598-020-68152-6","type":"journal-article","created":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T10:04:30Z","timestamp":1594634670000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Measurement of optical reflection and temperature changes after blood occlusion using a wearable device"],"prefix":"10.1038","volume":"10","author":[{"given":"Jian","family":"Gu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2119-6404","authenticated-orcid":false,"given":"Yoko","family":"Tomioka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Kida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingyi","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Itsuro","family":"Saito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mutsumi","family":"Okazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3051-1138","authenticated-orcid":false,"given":"Takao","family":"Someya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaki","family":"Sekino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,7,13]]},"reference":[{"key":"68152_CR1","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1002\/micr.10059","volume":"22","author":"T Kubo","year":"2002","unstructured":"Kubo, T., Yano, K. & Hosokawa, K. Management of flaps with compromised venous outflow in head and neck microsurgical reconstruction. Microsurgery 22, 391\u2013395 (2002).","journal-title":"Microsurgery"},{"key":"68152_CR2","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1097\/PRS.0b013e318218fc95","volume":"128","author":"J Fosnot","year":"2011","unstructured":"Fosnot, J. et al. Closer to an understanding of fate: the role of vascular complications in free flap breast reconstruction. Plast. Reconstr. Surg. 128, 835\u2013843 (2011).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR3","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1097\/01.prs.0000236898.87398.d6","volume":"118","author":"BJ Mehrara","year":"2006","unstructured":"Mehrara, B. J. et al. Complications after microvascular breast reconstruction: experience with 1195 flaps. Plast. Reconstr. Surg. 118, 1100\u20131109 (2006).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR4","doi-asserted-by":"crossref","first-page":"387","DOI":"10.14639\/0392-100X-1376","volume":"37","author":"C Copelli","year":"2017","unstructured":"Copelli, C. et al. Management of free flap failure in head and neck surgery. Acta Otorhinolaryngol. Ital. 37, 387\u2013392 (2017).","journal-title":"Acta Otorhinolaryngol. Ital."},{"key":"68152_CR5","unstructured":"Kwok, A. et al. Operative time and flap failure in unilateral and bilateral free flap breast reconstruction. J. Reconstr. Microsurg. 1, (2018)."},{"key":"68152_CR6","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1097\/00006534-199612000-00017","volume":"98","author":"SS Kroll","year":"1996","unstructured":"Kroll, S. S. et al. Timing of pedicle thrombosis and flap loss after free-tissue transfer. Plast. Reconstr. Surg. 98, 1230\u20131233 (1996).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR7","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.1097\/01.prs.0000256045.71765.96","volume":"119","author":"NV Tran","year":"2007","unstructured":"Tran, N. V., Buchel, E. W. & Convery, P. A. Microvascular complications of DIEP flaps. Plast. Reconstr. Surg. 119, 1397\u20131405 (2007).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR8","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1097\/WON.0000000000000314","volume":"44","author":"N Khatri","year":"2017","unstructured":"Khatri, N., Zhang, S. & Kale, S. S. Current techniques for postoperative monitoring of microvascular free flaps. J. Wound Ostomy Cont. Nurs. 44, 148\u2013152 (2017).","journal-title":"J. Wound Ostomy Cont. Nurs."},{"key":"68152_CR9","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1097\/PSN.0000000000000037","volume":"34","author":"AH Chao","year":"2014","unstructured":"Chao, A. H. & Lamp, S. Current approaches to free flap monitoring. Plast. Surg. Nurs. 34, 52\u201356 (2014).","journal-title":"Plast. Surg. Nurs."},{"key":"68152_CR10","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.cps.2011.03.005","volume":"38","author":"MY Nahabedian","year":"2011","unstructured":"Nahabedian, M. Y. Overview of perforator imaging and flap perfusion technologies. Clin. Plast. Surg. 38, 165\u2013174 (2011).","journal-title":"Clin. Plast. Surg."},{"key":"68152_CR11","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.bjps.2013.10.024","volume":"67","author":"JCR Wormald","year":"2014","unstructured":"Wormald, J. C. R., Wade, R. G. & Figus, A. The increased risk of adverse outcomes in bilateral deep inferior epigastric artery perforator flap breast reconstruction compared to unilateral reconstruction: a systematic review and meta-analysis. J. Plast. Reconstr. Aesthetic Surg. 67, 143\u2013156 (2014).","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"68152_CR12","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1016\/j.bjps.2017.05.041","volume":"70","author":"G Zoccali","year":"2017","unstructured":"Zoccali, G., Molina, A. & Farhadi, J. Is long-term post-operative monitoring of microsurgical flaps still necessary?. J. Plast. Reconstr. Aesthetic Surg. 70, 996\u20131000 (2017).","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"68152_CR13","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1007\/s10439-005-5763-2","volume":"33","author":"FP Wieringa","year":"2005","unstructured":"Wieringa, F. P., Mastik, F. & Van Der Steen, A. F. W. Contactless multiple wavelength photoplethysmographic imaging: a first step toward \u2018spO 2 camera\u2019 technology. Ann. Biomed. Eng. 33, 1034\u20131041 (2005).","journal-title":"Ann. Biomed. Eng."},{"key":"68152_CR14","doi-asserted-by":"publisher","first-page":"6416","DOI":"10.1364\/OPEX.13.006416","volume":"13","author":"A Serov","year":"2005","unstructured":"Serov, A. & Lasser, T. High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor. Opt. Express 13, 6416 (2005).","journal-title":"Opt. Express"},{"key":"68152_CR15","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.mvr.2015.06.002","volume":"101","author":"M Bergkvist","year":"2015","unstructured":"Bergkvist, M. et al. Assessment of microcirculation of the skin using Tissue Viability Imaging: a promising technique for detecting venous stasis in the skin. Microvasc. Res. 101, 20\u201325 (2015).","journal-title":"Microvasc. Res."},{"key":"68152_CR16","doi-asserted-by":"crossref","unstructured":"Salgarello, M., Pagliara, D., Barone-adesi, L., Rossi, M. & Visconti, G. Postoperative monitoring of free DIEP flap in breast reconstruction with near-infrared spectroscopy\u202f: variables affecting the regional oxygen saturation. 1, (2017).","DOI":"10.1055\/s-0038-1636527"},{"key":"68152_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-016-0028-x","volume":"7","author":"Y Tomioka","year":"2017","unstructured":"Tomioka, Y. et al. Multipoint tissue circulation monitoring with a flexible optical probe. Sci. Rep. 7, 1\u201313 (2017).","journal-title":"Sci. Rep."},{"key":"68152_CR18","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1097\/PRS.0b013e3181c49580","volume":"125","author":"JM Smit","year":"2010","unstructured":"Smit, J. M., Zeebregts, C. J., Acosta, R. & Werker, P. M. N. Advancements in free flap monitoring in the last decade: a critical review. Plast. Reconstr. Surg. 125, 177\u2013185 (2010).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR19","doi-asserted-by":"publisher","first-page":"505","DOI":"10.5999\/aps.2013.40.5.505","volume":"40","author":"TOH Prasetyono","year":"2013","unstructured":"Prasetyono, T. O. H. & Adianto, S. The relationship between oxygen saturation and color alteration of a compromised skin flap: experimental study on the rabbit. Arch. Plast. Surg. 40, 505\u2013509 (2013).","journal-title":"Arch. Plast. Surg."},{"key":"68152_CR20","first-page":"121","volume":"44","author":"H Takiwaki","year":"1998","unstructured":"Takiwaki, H. Measurement of skin color\u202f: practical application and theoretical considerations. J. Med. Investig. 44, 121\u2013126 (1998).","journal-title":"J. Med. Investig."},{"key":"68152_CR21","doi-asserted-by":"publisher","unstructured":"Braegelmann, J., Braegelmann, C., Bieber, T. & Wenzel, J. Searching for a mathematical model for blood perfusion of random pattern skin fl aps\u202f: a clinical pilot study using in vivo laser speckle contrast imaging. (2018). https:\/\/doi.org\/10.1111\/jdv.14997","DOI":"10.1111\/jdv.14997"},{"key":"68152_CR22","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.17.9.090901","author":"T Lister","year":"2018","unstructured":"Lister, T. et al. Optical properties of human skin. https:\/\/doi.org\/10.1117\/1.JBO.17.9.090901 (2018).","journal-title":"Optical properties of human skin."},{"key":"68152_CR23","doi-asserted-by":"publisher","first-page":"323","DOI":"10.5357\/koubyou.65.323","volume":"65","author":"T Suzuki","year":"1998","unstructured":"Suzuki, T. Experimental and clinical studies of color changes of island flaps. J. Stomatol. Soc. Japan 65, 323\u2013333 (1998).","journal-title":"J. Stomatol. Soc. Japan"},{"key":"68152_CR24","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1002\/jbio.201600189","volume":"10","author":"S Chen","year":"2017","unstructured":"Chen, S. et al. Spectral diffuse reflectance and autofluorescence imaging can perform early prediction of blood vessel occlusion in skin flaps. J. Biophoton. 10, 1665\u20131675 (2017).","journal-title":"J. Biophoton."},{"key":"68152_CR25","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1364\/BOE.7.000570","volume":"7","author":"C Zhu","year":"2016","unstructured":"Zhu, C., Chen, S., Chui, C.H.-K., Tan, B.-K. & Liu, Q. Early detection and differentiation of venous and arterial occlusion in skin flaps using visible diffuse reflectance spectroscopy and autofluorescence spectroscopy. Biomed. Opt. Express 7, 570 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"68152_CR26","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.1016\/j.bjps.2012.07.026","volume":"65","author":"T Yamamoto","year":"2012","unstructured":"Yamamoto, T., Todokoro, T. & Koshima, I. Handheld thermography for flap monitoring. J. Plast. Reconstr. Aesthetic Surg. 65, 1747\u20131748 (2012).","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"68152_CR27","doi-asserted-by":"publisher","unstructured":"Steenackers, G., Peeters, J., Parizel, P. & Tjalma, W. Application of passive infrared thermography for DIEP flap breast reconstruction. Proc. 2018 Int. Conf. Quant. InfraRed Thermogr. (2018). https:\/\/doi.org\/10.21611\/qirt.2018.p7","DOI":"10.21611\/qirt.2018.p7"},{"key":"68152_CR28","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1097\/SAP.0b013e31828b02fb","volume":"71","author":"JT Nguyen","year":"2013","unstructured":"Nguyen, J. T. et al. A novel pilot study using spatial frequency domain imaging to assess oxygenation of perforator flaps during reconstructive breast surgery. Ann. Plast. Surg. 71, 308\u2013315 (2013).","journal-title":"Ann. Plast. Surg."},{"key":"68152_CR29","doi-asserted-by":"publisher","first-page":"73","DOI":"10.21037\/gs.2016.12.01","volume":"6","author":"Y Hashimoto","year":"2017","unstructured":"Hashimoto, Y., Watanabe, N., Yuasa, T., Suzuki, Y. & Saisho, H. Breast reconstruction with absorbable mesh sling: dynamic infrared thermography of skin envelope. Gland Surg. 6, 73\u201381 (2017).","journal-title":"Gland Surg."},{"key":"68152_CR30","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1016\/j.bjps.2011.04.030","volume":"64","author":"R Kraemer","year":"2011","unstructured":"Kraemer, R. et al. Free flap microcirculatory monitoring correlates to free flap temperature assessment. J. Plast. Reconstr. Aesthetic Surg. 64, 1353\u20131358 (2011).","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"68152_CR31","doi-asserted-by":"publisher","first-page":"144e","DOI":"10.1097\/PRS.0b013e318186caf3","volume":"122","author":"ES Chiu","year":"2008","unstructured":"Chiu, E. S. et al. Free flap monitoring using skin temperature strip indicators: Adjunct to clinical examination. Plast. Reconstr. Surg. 122, 144e\u2013145e (2008).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR32","doi-asserted-by":"publisher","first-page":"2659","DOI":"10.1007\/s00405-015-3780-9","volume":"273","author":"M Just","year":"2016","unstructured":"Just, M. et al. Monitoring of microvascular free flaps following oropharyngeal reconstruction using infrared thermography: first clinical experiences. Eur. Arch. Oto-Rhino-Laryngol. 273, 2659\u20132667 (2016).","journal-title":"Eur. Arch. Oto-Rhino-Laryngol."},{"key":"68152_CR33","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1097\/00006534-199203000-00017","volume":"89","author":"KK Roger","year":"1992","unstructured":"Roger, K. K. & Shaw, W. W. Monitoring of free flaps with surface temperature recordings: Is it reliable?. Plast. Reconstr. Surg. 89, 495 (1992).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR34","doi-asserted-by":"publisher","first-page":"100257","DOI":"10.1016\/j.sbsr.2019.100257","volume":"22","author":"J Gu","year":"2019","unstructured":"Gu, J. et al. Algorithm for evaluating tissue circulation based on spectral changes in wearable photoplethysmography device. Sens. Bio-Sensing Res. 22, 100257 (2019).","journal-title":"Sens. Bio-Sensing Res."},{"key":"68152_CR35","unstructured":"P12347-01_15 Datasheet(1\/17 Pages) HAMAMATSU [online] Available at: https:\/\/html.alldatasheet.com\/html-pdf\/757183\/HAMAMATSU\/P12347-01_15\/491\/1\/P12347-01_15.html."},{"key":"68152_CR36","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1109\/RBME.2017.2739801","volume":"10","author":"V Periyasamy","year":"2017","unstructured":"Periyasamy, V. & Pramanik, M. Advances in Monte Carlo simulation for light propagation in tissue. IEEE Rev. Biomed. Eng. 10, 122\u2013135 (2017).","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"68152_CR37","doi-asserted-by":"publisher","first-page":"5387","DOI":"10.1364\/BOE.9.005387","volume":"9","author":"VV Zaytsev","year":"2018","unstructured":"Zaytsev, V. V., Miridonov, S. V., Mamontov, O. V. & Kamshilin, A. A. Contactless monitoring of the blood-flow changes in upper limbs. Biomed. Opt. Express 9, 5387 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"68152_CR38","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1097\/PRS.0000000000003415","volume":"140","author":"NB Agochukwu","year":"2017","unstructured":"Agochukwu, N. B. et al. A novel noncontact diffuse correlation spectroscopy device for assessing blood flow in mastectomy skin flaps: a prospective study in patients undergoing prosthesis-based reconstruction. Plast. Reconstr. Surg. 140, 26\u201331 (2017).","journal-title":"Plast. Reconstr. Surg."},{"key":"68152_CR39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1117\/1.JBO.23.9.096005","volume":"23","author":"S Mazdeyasna","year":"2018","unstructured":"Mazdeyasna, S. et al. Noncontact speckle contrast diffuse correlation tomography of blood flow distributions in tissues with arbitrary geometries. J. Biomed. Opt. 23, 1 (2018).","journal-title":"J. Biomed. Opt."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-68152-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-68152-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-68152-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T13:15:44Z","timestamp":1670332544000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-68152-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,13]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["68152"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-68152-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,13]]},"assertion":[{"value":"9 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11491"}}