{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T06:07:58Z","timestamp":1789538878244,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,3]],"date-time":"2020-09-03T00:00:00Z","timestamp":1599091200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,3]],"date-time":"2020-09-03T00:00:00Z","timestamp":1599091200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2015R1D1A1A01060016"],"award-info":[{"award-number":["NRF-2015R1D1A1A01060016"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The evaluation of proptosis is essential for the diagnosis of orbital disease. We have developed a computed tomography (CT)-based three-dimensional (3D) reconstruction software to measure the degree of proptosis. To verify clinical usefulness and reliability, the degree of proptosis was measured in 126 patients with Graves\u2019 orbitopathy (GO) with 3D reconstruction software and compared with those obtained with Hertel exophthalmometer and CT. The proptosis values measured by 3D reconstruction software, CT, and Hertel exophthalmometer were closely related to each other, but showed significant differences (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). In contrast, the amount of change in proptosis after orbital decompression were not different among the three measurements (<jats:italic>p<\/jats:italic>\u2009=\u20090.153). The intra-observer correlation coefficients of the 3D reconstruction software, CT, and Hertel exophthalmometer measurements were 0.997, 0.942, and 0.953, respectively. In patients with strabismus, the intra-observer correlation coefficient of CT and Hertel exophthalmometer decreased to 0.895 and 0.920, respectively, but the intra-observer correlation coefficient of the 3D reconstruction software did not change to 0.996. The inter-observer correlation coefficients of CT and 3D reconstruction software for three different ophthalmologists were 0.742 and 0.846, respectively. In conclusion, the measurement of proptosis by 3D reconstruction software seems to be a reliable method, especially in the presence of eyeball deviation.<\/jats:p>","DOI":"10.1038\/s41598-020-71098-4","type":"journal-article","created":{"date-parts":[[2020,9,3]],"date-time":"2020-09-03T10:04:10Z","timestamp":1599127450000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Measurement of proptosis using computed tomography based three-dimensional reconstruction software in patients with Graves\u2019 orbitopathy"],"prefix":"10.1038","volume":"10","author":[{"given":"Jung","family":"Huh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Joon","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong Kyu","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,9,3]]},"reference":[{"key":"71098_CR1","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1097\/00006324-199207000-00009","volume":"69","author":"IL Dunsky","year":"1992","unstructured":"Dunsky, I. L. Normative data for hertel exophthalmometry in a normal adult black population. Optom. Vis. Sci. Off. Publ. Am. Acad. Optom. 69, 562\u2013564 (1992).","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"71098_CR2","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/0002-9394(84)90127-2","volume":"98","author":"ME Migliori","year":"1984","unstructured":"Migliori, M. E. & Gladstone, G. J. Determination of the normal range of exophthalmometric values for black and white adults. Am. J. Ophthalmol. 98, 438\u2013442 (1984).","journal-title":"Am. J. Ophthalmol."},{"key":"71098_CR3","doi-asserted-by":"publisher","first-page":"1096b","DOI":"10.1136\/bjo.83.9.1096b","volume":"83","author":"NP O'Donnell","year":"1999","unstructured":"O\u2019Donnell, N. P., Virdi, M. & Kemp, E. G. Hertel exophthalmometry: the most appropriate measuring technique. Br. J. Ophthalmol. 83, 1096b (1999).","journal-title":"Br. J. Ophthalmol."},{"key":"71098_CR4","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1159\/000050850","volume":"215","author":"IT Kim","year":"2001","unstructured":"Kim, I. T. & Choi, J. B. Normal range of exophthalmos values on orbit computerized tomography in Koreans. Ophthalmol. J. Int. d\u2019ophtalmologie. Int. J. Ophthalmol. Zeitschrift fur Augenheilkunde 215, 156\u2013162. https:\/\/doi.org\/10.1159\/000050850 (2001).","journal-title":"Ophthalmol. J. Int. d'ophtalmologie. Int. J. Ophthalmol. Zeitschrift fur Augenheilkunde"},{"key":"71098_CR5","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/S0161-6420(85)33880-0","volume":"92","author":"DC Musch","year":"1985","unstructured":"Musch, D. C., Frueh, B. R. & Landis, J. R. The reliability of Hertel exophthalmometry. Observer variation between physician and lay readers. Ophthalmology 92, 1177\u20131180 (1985).","journal-title":"Ophthalmology"},{"key":"71098_CR6","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1111\/j.1442-9071.1995.tb00182.x","volume":"23","author":"AA Chang","year":"1995","unstructured":"Chang, A. A., Bank, A., Francis, I. C. & Kappagoda, M. B. Clinical exophthalmometry: a comparative study of the Luedde and Hertel exophthalmometers. Aust. N. Z. J. Ophthalmol. 23, 315\u2013318 (1995).","journal-title":"Aust. N. Z. J. Ophthalmol."},{"key":"71098_CR7","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1097\/01.iop.0000021971.72318.95","volume":"18","author":"TJ Sleep","year":"2002","unstructured":"Sleep, T. J. & Manners, R. M. Interinstrument variability in Hertel-type exophthalmometers. Ophthalmic Plast. Reconstr. Surg. 18, 254\u2013257. https:\/\/doi.org\/10.1097\/01.iop.0000021971.72318.95 (2002).","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"71098_CR8","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1001\/archopht.1985.01050090107043","volume":"103","author":"BR Frueh","year":"1985","unstructured":"Frueh, B. R., Garber, F., Grill, R. & Musch, D. C. Positional effects on exophthalmometer readings in Graves\u2019 eye disease. Arch. Ophthalmol. (Chicago, Ill.: 1960) 103, 1355\u20131356 (1985).","journal-title":"Arch. Ophthalmol. (Chicago, Ill.: 1960)"},{"key":"71098_CR9","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1097\/01.IOP.0000143712.42344.8C","volume":"20","author":"H Ameri","year":"2004","unstructured":"Ameri, H. & Fenton, S. Comparison of unilateral and simultaneous bilateral measurement of the globe position, using the Hertel exophthalmometer. Ophthalmic Plast. Reconstr. Surg. 20, 448\u2013451 (2004).","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"71098_CR10","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1136\/bjo.72.9.678","volume":"72","author":"ES Hallin","year":"1988","unstructured":"Hallin, E. S. & Feldon, S. E. Graves\u2019 ophthalmopathy: II. Correlation of clinical signs with measures derived from computed tomography. Br. J. Ophthalmol. 72, 678\u2013682 (1988).","journal-title":"Br. J. Ophthalmol."},{"key":"71098_CR11","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/S0002-9394(02)01429-0","volume":"133","author":"M Segni","year":"2002","unstructured":"Segni, M., Bartley, G. B., Garrity, J. A., Bergstralh, E. J. & Gorman, C. A. Comparability of proptosis measurements by different techniques. Am. J. Ophthalmol. 133, 813\u2013818 (2002).","journal-title":"Am. J. Ophthalmol."},{"key":"71098_CR12","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.jcms.2003.07.001","volume":"31","author":"E Nkenke","year":"2003","unstructured":"Nkenke, E. et al. Relative en- and exophthalmometry in zygomatic fractures comparing optical non-contact, non-ionizing 3D imaging to the Hertel instrument and computed tomography. J. Cranio-Maxillo-Fac. Surg. Off. Publ. Eur. Assoc. Cranio-Maxillo-Fac. Surg. 31, 362\u2013368 (2003).","journal-title":"J. Cranio-Maxillo-Fac. Surg. Off. Publ. Eur. Assoc. Cranio-Maxillo-Fac. Surg."},{"key":"71098_CR13","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1054\/ijom.2002.0481","volume":"33","author":"E Nkenke","year":"2004","unstructured":"Nkenke, E. et al. Hertel exophthalmometry versus computed tomography and optical 3D imaging for the determination of the globe position in zygomatic fractures. Int. J. Oral Maxillofac. Surg. 33, 125\u2013133. https:\/\/doi.org\/10.1054\/ijom.2002.0481 (2004).","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"71098_CR14","doi-asserted-by":"publisher","first-page":"257","DOI":"10.3109\/01676830.2015.1057291","volume":"34","author":"N Ramli","year":"2015","unstructured":"Ramli, N., Kala, S., Samsudin, A., Rahmat, K. & Abidin, Z. Z. Proptosis-correlation and agreement between hertel exophthalmometry and computed tomography. Orbit (Amsterdam, Netherlands) 34, 257\u2013262. https:\/\/doi.org\/10.3109\/01676830.2015.1057291 (2015).","journal-title":"Orbit (Amsterdam, Netherlands)"},{"key":"71098_CR15","first-page":"239","volume":"22","author":"MB Kashkouli","year":"2003","unstructured":"Kashkouli, M. B., Beigi, B., Noorani, M. M. & Nojoomi, M. Hertel exophthalmometry: reliability and interobserver variation. Orbit (Amsterdam, Netherlands) 22, 239\u2013245 (2003).","journal-title":"Orbit (Amsterdam, Netherlands)"},{"key":"71098_CR16","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1097\/scs.0000000000002334","volume":"27","author":"HB Jeon","year":"2016","unstructured":"Jeon, H. B., Kang, D. H., Oh, S. A. & Gu, J. H. Comparative study of naugle and Hertel exophthalmometry in orbitozygomatic fracture. J. Craniofacial Surg. 27, 142\u2013144. https:\/\/doi.org\/10.1097\/scs.0000000000002334 (2016).","journal-title":"J. Craniofacial Surg."},{"key":"71098_CR17","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1475-1313.2008.00617.x","volume":"29","author":"AK Lam","year":"2009","unstructured":"Lam, A. K., Lam, C. F., Leung, W. K. & Hung, P. K. Intra-observer and inter-observer variation of Hertel exophthalmometry. Ophthalmic Physiol. Opt. J. Br. Coll. Ophthalmic Opt. (Optometrists) 29, 472\u2013476. https:\/\/doi.org\/10.1111\/j.1475-1313.2008.00617.x (2009).","journal-title":"Ophthalmic Physiol. Opt. J. Br. Coll. Ophthalmic Opt. (Optometrists)"},{"key":"71098_CR18","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.2147\/opth.s216838","volume":"13","author":"NR Park","year":"2019","unstructured":"Park, N. R., Moon, J. H. & Lee, J. K. Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy. Clin. Ophthalmol. 13, 1461\u20131467. https:\/\/doi.org\/10.2147\/opth.s216838 (2019).","journal-title":"Clin. Ophthalmol."},{"key":"71098_CR19","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1007\/s00417-016-3538-0","volume":"255","author":"JS Byun","year":"2017","unstructured":"Byun, J. S., Moon, N. J. & Lee, J. K. Quantitative analysis of orbital soft tissues on computed tomography to assess the activity of thyroid-associated orbitopathy. Graefes Arch. Clin. Exp. Ophthalmol. 255, 413\u2013420. https:\/\/doi.org\/10.1007\/s00417-016-3538-0 (2017).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"71098_CR20","doi-asserted-by":"publisher","first-page":"e108335","DOI":"10.1371\/journal.pone.0108335","volume":"9","author":"YJ Ryu","year":"2014","unstructured":"Ryu, Y. J. et al. Glioma: application of whole-tumor texture analysis of diffusion-weighted imaging for the evaluation of tumor heterogeneity. PLoS ONE 9, e108335. https:\/\/doi.org\/10.1371\/journal.pone.0108335 (2014).","journal-title":"PLoS ONE"},{"key":"71098_CR21","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1148\/radiol.14132324","volume":"273","author":"YS Song","year":"2014","unstructured":"Song, Y. S. et al. Volume and mass doubling times of persistent pulmonary subsolid nodules detected in patients without known malignancy. Radiology 273, 276\u2013284. https:\/\/doi.org\/10.1148\/radiol.14132324 (2014).","journal-title":"Radiology"},{"key":"71098_CR22","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1097\/rli.0000000000000174","volume":"50","author":"SY Ahn","year":"2015","unstructured":"Ahn, S. Y. et al. Prognostic value of computed tomography texture features in non-small cell lung cancers treated with definitive concomitant chemoradiotherapy. Invest. Radiol. 50, 719\u2013725. https:\/\/doi.org\/10.1097\/rli.0000000000000174 (2015).","journal-title":"Invest. Radiol."},{"key":"71098_CR23","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1097\/rli.0000000000000186","volume":"50","author":"IP Hwang","year":"2015","unstructured":"Hwang, I. P. et al. Persistent pure ground-glass nodules larger than 5 mm: differentiation of Invasive pulmonary adenocarcinomas from preinvasive lesions or minimally invasive adenocarcinomas using texture analysis. Invest. Radiol. 50, 798\u2013804. https:\/\/doi.org\/10.1097\/rli.0000000000000186 (2015).","journal-title":"Invest. Radiol."},{"key":"71098_CR24","doi-asserted-by":"publisher","first-page":"e0126175","DOI":"10.1371\/journal.pone.0126175","volume":"10","author":"JH Lee","year":"2015","unstructured":"Lee, J. H. et al. Value of computerized 3D shape analysis in differentiating encapsulated from invasive thymomas. PLoS ONE 10, e0126175. https:\/\/doi.org\/10.1371\/journal.pone.0126175 (2015).","journal-title":"PLoS ONE"},{"key":"71098_CR25","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1097\/rli.0000000000000267","volume":"51","author":"H Kim","year":"2016","unstructured":"Kim, H. et al. Temporal changes of texture features extracted from pulmonary nodules on dynamic contrast-enhanced chest computed tomography: how influential is the scan delay?. Invest. Radiol. 51, 569\u2013574. https:\/\/doi.org\/10.1097\/rli.0000000000000267 (2016).","journal-title":"Invest. Radiol."},{"key":"71098_CR26","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1109\/tpami.2004.60","volume":"26","author":"Y Boykov","year":"2004","unstructured":"Boykov, Y. & Kolmogorov, V. An experimental comparison of min-cut\/max-flow algorithms for energy minimization in vision. IEEE Trans. Pattern Anal. Mach. Intell. 26, 1124\u20131137. https:\/\/doi.org\/10.1109\/tpami.2004.60 (2004).","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-71098-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-71098-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-71098-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T17:52:05Z","timestamp":1670349125000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-71098-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,3]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["71098"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-71098-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,3]]},"assertion":[{"value":"10 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"14554"}}