{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T07:35:48Z","timestamp":1763105748169,"version":"build-2065373602"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T00:00:00Z","timestamp":1601337600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T00:00:00Z","timestamp":1601337600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012701","name":"Saga University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012701","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To determine the prophylactic effect of using combined 1% alcoholic chlorhexidine gluconate and chlorhexidine gel-impregnated dressings (CGCD) on catheter-related thrombosis (CRT) in critically ill patients. This retrospective cohort study was performed in an intensive care unit from November 2009 to August 2014. The CRT incidence diagnosed with ultrasound examination was compared between patients applying CGCD and combined 10% aqueous povidone-iodine and standard transparent dressings (PITD) after central venous catheter insertion into the internal jugular vein for\u2009\u2265\u200948\u00a0h. CRT was stratified into early (within 7\u00a0days) and late (days 8\u201314) thromboses. Multivariate analyses using logistic regression models clarified the relationships between early- and late-CRT risks and skin antiseptic and catheter site dressing combinations. CRT occurred in 74 of 134 patients (55%), including 52 with early CRT and 22 with late CRT. Patients receiving CGCD had a significantly lower incidence of early CRT than those receiving PITD (odds ratio\u2009=\u20090.18; 95% confidence interval\u2009=\u20090.07\u20130.45, <jats:italic>p<\/jats:italic>\u2009 &lt; .001). No significant association was evident between using CGCD and late CRT (<jats:italic>p<\/jats:italic>\u2009 = .514). Compared to PITD, CGCD reduced the CRT risk over 7\u00a0days in critically ill patients.<\/jats:p><jats:p>UMIN Clinical Trials Registry: UMIN000037492.<\/jats:p>","DOI":"10.1038\/s41598-020-72709-w","type":"journal-article","created":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T10:04:34Z","timestamp":1601373874000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Early prophylaxis of central venous catheter-related thrombosis using 1% chlorhexidine gluconate and chlorhexidine-gel-impregnated dressings: a retrospective cohort study"],"prefix":"10.1038","volume":"10","clinical-trial-number":[{"clinical-trial-number":"umin000037492","registry":"10.18810\/umin-japan"}],"author":[{"given":"Tomoko","family":"Yamashita","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayako","family":"Takamori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Nakagawachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Tanigawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yohei","family":"Hamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yosuke","family":"Aoki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiro","family":"Sakaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,29]]},"reference":[{"key":"72709_CR1","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1086\/323130","volume":"33","author":"RO Darouiche","year":"2001","unstructured":"Darouiche, R. O. Device-associated infections: A macroproblem that starts with microadherence. Clin. Infect. Dis. 33, 1567\u20131572 (2001).","journal-title":"Clin. Infect. Dis."},{"key":"72709_CR2","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1016\/S0952-8180(99)00093-8","volume":"11","author":"X Wu","year":"1999","unstructured":"Wu, X., Studer, W., Skarvan, K. & Seeberger, M. D. High incidence of intravenous thrombi after short-term central venous catheterization of the internal jugular vein. J. Clin. Anesth. 11, 482\u2013485 (1999).","journal-title":"J. Clin. Anesth."},{"key":"72709_CR3","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s11739-008-0142-2","volume":"3","author":"R Frizzelli","year":"2008","unstructured":"Frizzelli, R. et al. Deep venous thrombosis of the neck and pulmonary embolism in patients with a central venous catheter admitted to cardiac rehabilitation after cardiac surgery: A prospective study of 815 patients. Intern. Emerg. Med. 3, 325\u2013330 (2008).","journal-title":"Intern. Emerg. Med."},{"key":"72709_CR4","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1378\/chest.114.1.207","volume":"114","author":"JF Timsit","year":"1998","unstructured":"Timsit, J. F. et al. Central vein catheter-related thrombosis in intensive care patients: Incidence, risks factors, and relationship with catheter-related sepsis. Chest 114, 207\u2013213 (1998).","journal-title":"Chest"},{"key":"72709_CR5","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.thromres.2013.08.007","volume":"132","author":"MI Del Principe","year":"2013","unstructured":"Del Principe, M. I. et al. Infections increase the risk of central venous catheter-related thrombosis in adult acute myeloid leukemia. Thromb. Res. 132, 511\u2013514 (2013).","journal-title":"Thromb. Res."},{"issue":"901","key":"72709_CR6","first-page":"e1","volume":"120","author":"A Kirkpatrick","year":"2007","unstructured":"Kirkpatrick, A., Rathbun, S., Whitsett, T. & Raskob, G. Prevention of central venous catheter-associated thrombosis: A meta-analysis. Am. J. Med. 120(901), e1-901.e13 (2007).","journal-title":"Am. J. Med."},{"key":"72709_CR7","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s00280-013-2169-y","volume":"72","author":"S Lavau-Denes","year":"2013","unstructured":"Lavau-Denes, S. et al. Prophylaxis of catheter-related deep vein thrombosis in cancer patients with low-dose warfarin, low molecular weight heparin, or control: A randomized, controlled, phase III study. Cancer Chemother. Pharmacol. 72, 65\u201373 (2013).","journal-title":"Cancer Chemother. Pharmacol."},{"key":"72709_CR8","doi-asserted-by":"publisher","first-page":"369","DOI":"10.5507\/bp.2017.034","volume":"161","author":"O Hrdy","year":"2017","unstructured":"Hrdy, O. et al. Central venous catheter-related thrombosis in intensive care patients\u2014incidence and risk factors: A prospective observational study. Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 161, 369\u2013373 (2017).","journal-title":"Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub."},{"key":"72709_CR9","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1200\/JCO.2005.05.002","volume":"23","author":"CJ van Rooden","year":"2005","unstructured":"van Rooden, C. J. et al. Infectious complications of central venous catheters increase the risk of catheter-related thrombosis in hematology patients: A prospective study. J. Clin. Oncol. 23, 2655\u20132660 (2005).","journal-title":"J. Clin. Oncol."},{"key":"72709_CR10","doi-asserted-by":"publisher","first-page":"792","DOI":"10.7326\/0003-4819-136-11-200206040-00007","volume":"136","author":"N Chaiyakunapruk","year":"2002","unstructured":"Chaiyakunapruk, N., Veenstra, D. L., Lipsky, B. A. & Saint, S. Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: A meta-analysis. Ann. Intern. Med. 136, 792\u2013801 (2002).","journal-title":"Ann. Intern. Med."},{"key":"72709_CR11","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1086\/590259","volume":"29","author":"J Vall\u00e9s","year":"2008","unstructured":"Vall\u00e9s, J. et al. Prospective randomized trial of 3 antiseptic solutions for prevention of catheter colonization in an intensive care unit for adult patients. Infect. Control Hosp. Epidemiol. 29, 847\u2013853 (2008).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"72709_CR12","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1001\/jama.2009.376","volume":"301","author":"JF Timsit","year":"2009","unstructured":"Timsit, J. F. et al. Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: A randomized controlled trial. JAMA 301, 1231\u20131241 (2009).","journal-title":"JAMA"},{"key":"72709_CR13","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1164\/rccm.201206-1038OC","volume":"186","author":"JF Timsit","year":"2012","unstructured":"Timsit, J. F. et al. Randomized controlled trial of chlorhexidine dressing and highly adhesive dressing for preventing catheter-related infections in critically ill adults. Am. J. Respir. Crit. Care Med. 186, 1272\u20131278 (2012).","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"72709_CR14","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1182\/asheducation-2014.1.306","volume":"1","author":"W Geerts","year":"2014","unstructured":"Geerts, W. Central venous catheter-related thrombosis. Hematol. Am. Soc. Hematol. Educ. Program. 1, 306\u2013311 (2014).","journal-title":"Hematol. Am. Soc. Hematol. Educ. Program."},{"key":"72709_CR15","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/S0009-9260(05)83313-6","volume":"50","author":"C K\u00f6ksoy","year":"1995","unstructured":"K\u00f6ksoy, C. et al. The diagnostic value of colour Doppler ultrasound in central venous catheter related thrombosis. Clin. Radiol. 50, 687\u2013689 (1995).","journal-title":"Clin. Radiol."},{"key":"72709_CR16","doi-asserted-by":"publisher","first-page":"633","DOI":"10.3918\/jsicm.19.633","volume":"19","author":"T Yamada","year":"2012","unstructured":"Yamada, T. et al. Investigation of central venous catheter-related thrombosis in intensive care patients. Nihon Syuutyuutiryou Igakkai Zasshi (J. Jpn. Soc. Intensive Care Med) 19, 633\u2013637 (2012) (in Japanese; abstract in English).","journal-title":"Nihon Syuutyuutiryou Igakkai Zasshi (J. Jpn. Soc. Intensive Care Med)"},{"key":"72709_CR17","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/00003246-198510000-00009","volume":"13","author":"WA Knaus","year":"1985","unstructured":"Knaus, W. A., Draper, E. A., Wagner, D. P. & Zimmerman, J. E. APACHE II: A severity of disease classification system. Crit. Care Med. 13, 818\u2013829 (1985).","journal-title":"Crit. Care Med."},{"key":"72709_CR18","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.ajic.2008.03.002","volume":"36","author":"TC Horan","year":"2008","unstructured":"Horan, T. C., Andrus, M. & Dudeck, M. A. CDC\/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am. J. Infect. Control 36, 309\u2013332 (2008).","journal-title":"Am. J. Infect. Control"},{"key":"72709_CR19","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1038\/bmt.2012.244","volume":"48","author":"Y Kanda","year":"2013","unstructured":"Kanda, Y. Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics. Bone Marrow Transplant. 48, 452\u2013458 (2013).","journal-title":"Bone Marrow Transplant."},{"key":"72709_CR20","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1378\/chest.10-2637","volume":"140","author":"TP Nifong","year":"2011","unstructured":"Nifong, T. P. & McDevitt, T. J. The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheters. Chest 140, 48\u201353 (2011).","journal-title":"Chest"},{"key":"72709_CR21","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1148\/radiol.2402031129","volume":"240","author":"AR Forauer","year":"2006","unstructured":"Forauer, A. R., Theoharis, C. G. & Dasika, N. L. Jugular vein catheter placement: Histologic features and development of catheter-related (fibrin) sheaths in a swine model. Radiology 240, 427\u2013434 (2006).","journal-title":"Radiology"},{"key":"72709_CR22","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1177\/1129729818769033","volume":"19","author":"CJ Sylvia","year":"2018","unstructured":"Sylvia, C. J. et al. Chlorhexidine-coated peripherally inserted central catheters reduce fibroblastic sleeve formation in an in vivo ovine model. J. Vasc. Access. 19, 644\u2013650 (2018).","journal-title":"J. Vasc. Access."},{"key":"72709_CR23","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1007\/s00134-018-5212-y","volume":"44","author":"JF Timsit","year":"2018","unstructured":"Timsit, J. F. et al. A state of the art review on optimal practices to prevent, recognize, and manage complications associated with intravascular devices in the critically ill. Intensive Care Med. 44, 742\u2013759 (2018).","journal-title":"Intensive Care Med."},{"key":"72709_CR24","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1007\/s00134-003-2045-z","volume":"30","author":"N Safdar","year":"2004","unstructured":"Safdar, N. & Maki, D. G. The pathogenesis of catheter-related bloodstream infection with noncuffed short-term central venous catheters. Intensive Care Med. 30, 62\u201367 (2004).","journal-title":"Intensive Care Med."},{"key":"72709_CR25","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1007\/s00134-016-4480-7","volume":"43","author":"C Beloin","year":"2017","unstructured":"Beloin, C., Fern\u00e1ndez-Hidalgo, N. & Lebeaux, D. Understanding biofilm formation in intravascular device-related infections. Intensive Care Med. 43, 443\u2013446 (2017).","journal-title":"Intensive Care Med."},{"key":"72709_CR26","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1097\/00003246-200204000-00033","volume":"30","author":"JR Mehall","year":"2002","unstructured":"Mehall, J. R., Saltzman, D. A., Jackson, R. J. & Smith, S. D. Fibrin sheath enhances central venous catheter infection. Crit. Care Med. 30, 908\u2013912 (2002).","journal-title":"Crit. Care Med."},{"key":"72709_CR27","first-page":"S1036","volume":"19","author":"ML Mitchell","year":"2019","unstructured":"Mitchell, M. L. et al. Central venous access device Securement and dressing effectiveness: The CASCADE pilot randomised controlled trial in the adult intensive care. Aust. Crit. Care. 19, S1036-7314 (2019).","journal-title":"Aust. Crit. Care."},{"key":"72709_CR28","doi-asserted-by":"publisher","first-page":"2967","DOI":"10.1182\/blood.V88.8.2967.bloodjournal8882967","volume":"88","author":"TN Zaidi","year":"1996","unstructured":"Zaidi, T. N., McIntire, L. V., Farrell, D. H. & Thiagarajan, P. Adhesion of platelets to surface-bound fibrinogen under flow. Blood 88, 2967\u20132972 (1996).","journal-title":"Blood"},{"key":"72709_CR29","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1055\/s-0039-1693705","volume":"40","author":"N Buetti","year":"2019","unstructured":"Buetti, N. & Timsit, J. F. Management and prevention of central venous catheter-related infections in the ICU. Semin. Respir. Crit. Care Med. 40, 508\u2013523 (2019).","journal-title":"Semin. Respir. Crit. Care Med."},{"key":"72709_CR30","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1016\/S0142-9612(00)00031-4","volume":"21","author":"M Tanaka","year":"2000","unstructured":"Tanaka, M. et al. Blood compatible aspects of poly(2-methoxyethylacrylate) (PMEA)\u2014Relationship between protein adsorption and platelet adhesion on PMEA surface. Biomaterials 21, 1471\u20131481 (2000).","journal-title":"Biomaterials"},{"key":"72709_CR31","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1177\/1129729819879317","volume":"21","author":"H Tanabe","year":"2020","unstructured":"Tanabe, H. et al. Vascular endothelium damage from catheter-induced mechanical stimulation causes catheter sleeve formation in a rabbit model. J. Vasc. Access. 21, 379\u2013386 (2020).","journal-title":"J. Vasc. Access."},{"key":"72709_CR32","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1111\/j.1538-7836.2010.03771.x","volume":"8","author":"M Di Nisio","year":"2010","unstructured":"Di Nisio, M. et al. Accuracy of diagnostic tests for clinically suspected upper extremity deep vein thrombosis: A systematic review. J. Thromb. Haemost. 8, 684\u2013692 (2010).","journal-title":"J. Thromb. Haemost."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-72709-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-72709-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-72709-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T20:43:20Z","timestamp":1670359400000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-72709-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,29]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["72709"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-72709-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2020,9,29]]},"assertion":[{"value":"26 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Yosuke Aoki received a scholarship and a speaker\u2019s honorarium from Shionogi & Co., Ltd., MSD K.K., and Pfizer Japan, Inc. The other authors declares no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15952"}}