{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T22:33:48Z","timestamp":1794263628936,"version":"4.9.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T00:00:00Z","timestamp":1601424000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T00:00:00Z","timestamp":1601424000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Repeated blood pressure (BP) measurements allow better control of hypertension. Current measurements rely on cuff-based devices. The aim of the present study was to compare BP measurements using a novel cuff-less photoplethysmography-based device to a standard sphygmomanometer device. Males and females were recruited from within the general population who arrived at a public BP screening station. One to two measurements were taken from each using a sphygmomanometer-based and the photoplethysmography-based devices. Devices were considered equal if the mean difference between paired measurements was below 5\u00a0mmHg and the Standard Deviation (SD) was no greater than 8\u00a0mmHg. Agreement and reliability analyses were also performed. 1057 subjects were included in the study analysis. There were no adverse events during the study. The mean (\u00b1\u2009SD) difference between paired measurements for all subjects was -0.1\u2009\u00b1\u20093.6\u00a0mmHg for the systolic and 0.0\u2009\u00b1\u20093.5\u00a0mmHg for the diastolic readings. We found 96.31% agreement in identifying hypertension and an Interclass Correlation Coefficient of 0.99 and 0.97 for systolic and diastolic measurements, respectively. The photoplethysmography-based device was found similar to the gold-standard sphygmomanometer-based device with high agreement and reliability levels. The device might enable a reliable, more convenient method for repeated BP monitoring.<\/jats:p>","DOI":"10.1038\/s41598-020-73172-3","type":"journal-article","created":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T06:05:26Z","timestamp":1601445926000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":99,"title":["Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device"],"prefix":"10.1038","volume":"10","author":[{"given":"Dean","family":"Nachman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yftach","family":"Gepner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nir","family":"Goldstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eli","family":"Kabakov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arik Ben","family":"Ishay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Romi","family":"Littman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuval","family":"Azmon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eli","family":"Jaffe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arik","family":"Eisenkraft","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,9,30]]},"reference":[{"key":"73172_CR1","doi-asserted-by":"crossref","unstructured":"Weir, M.R. In the clinic: hypertension. Ann. Intern. Med. 161, ITC1\u201315 (2014).","DOI":"10.7326\/0003-4819-161-11-201412020-01006"},{"key":"73172_CR2","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1056\/NEJMoa1803180","volume":"381","author":"AC Flint","year":"2019","unstructured":"Flint, A. C. et al. Effect of systolic and diastolic blood pressure on cardiovascular outcomes. N. Engl. J. Med. 381, 243\u2013251 (2019).","journal-title":"N. Engl. J. Med."},{"key":"73172_CR3","doi-asserted-by":"crossref","first-page":"1899","DOI":"10.1016\/S0140-6736(14)60685-1","volume":"383","author":"E Rapsomaniki","year":"2014","unstructured":"Rapsomaniki, E. et al. Blood pressure and incidence of twelve cardiovascular diseases: lifetime risks, healthy life-years lost, and age-specific associations in 1.25 million people. Lancet 383, 1899\u2013911 (2014).","journal-title":"Lancet"},{"key":"73172_CR4","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1038\/sj.jhh.1001133","volume":"15","author":"M Aylett","year":"2001","unstructured":"Aylett, M. et al. Evaluation of normal and large sphygmomanometer cuffs using the Omron 705CP. J. Hum. Hypertens. 15, 131\u2013134 (2001).","journal-title":"J. Hum. Hypertens."},{"key":"73172_CR5","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.1136\/bmj.294.6587.1614-a","volume":"294","author":"DG Beevers","year":"1987","unstructured":"Beevers, D. G. et al. Standards for blood pressure measuring devices. BMJ (Clin Res Ed) 294, 1614 (1987).","journal-title":"BMJ (Clin Res Ed)"},{"key":"73172_CR6","doi-asserted-by":"crossref","first-page":"e85","DOI":"10.2196\/jmir.5414","volume":"18","author":"TS Schoot","year":"2016","unstructured":"Schoot, T. S. et al. A new cuffless device for measuring blood pressure: a real-life validation study. J. Med. Internet. Res. 18, e85 (2016).","journal-title":"J. Med. Internet. Res."},{"key":"73172_CR7","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1093\/ajh\/hpx056","volume":"30","author":"M Ruzicka","year":"2017","unstructured":"Ruzicka, M. & Hiremath, S. Accuracy-limiting factor of home blood pressure monitors?. Am. J. Hypertens. 30, 661\u2013664 (2017).","journal-title":"Am. J. Hypertens."},{"key":"73172_CR8","doi-asserted-by":"crossref","unstructured":"Sol\u00e1, J., et al. Wearable PWV technologies to measure\u00a0Blood Pressure: eliminating brachial cuffs. In 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 4098\u20134101 (2013).","DOI":"10.1109\/EMBC.2013.6610446"},{"key":"73172_CR9","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/j.jash.2017.06.012","volume":"11","author":"IM Kronish","year":"2017","unstructured":"Kronish, I. M. et al. Barriers to conducting ambulatory and home blood pressure monitoring during hypertension screening in the United States. J. Am. Soc. Hypertens. 11, 573\u2013580 (2017).","journal-title":"J. Am. Soc. Hypertens."},{"key":"73172_CR10","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1161\/01.CIR.0000154900.76284.F6","volume":"111","author":"TG Pickering","year":"2005","unstructured":"Pickering, T. G. et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation 111, 697\u2013716 (2005).","journal-title":"Circulation"},{"key":"73172_CR11","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1001\/jama.2016.19043","volume":"317","author":"MH Forouzanfar","year":"2017","unstructured":"Forouzanfar, M. H. et al. Global burden of hypertension and systolic blood pressure of at least 110 to 115 mm Hg, 1990\u20132015. JAMA 317, 165\u2013182 (2017).","journal-title":"JAMA"},{"key":"73172_CR12","doi-asserted-by":"crossref","first-page":"2083","DOI":"10.1001\/jama.2017.18605","volume":"318","author":"P Greenland","year":"2017","unstructured":"Greenland, P. & Peterson, E. The new 2017 ACC\/AHA guidelines \u201cup the pressure\u201d on diagnosis and treatment of hypertension. JAMA 318, 2083\u20132084 (2017).","journal-title":"JAMA"},{"key":"73172_CR13","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1001\/jama.2017.18706","volume":"318","author":"AS Cifu","year":"2017","unstructured":"Cifu, A. S. & Davis, A. M. Prevention, detection, evaluation, and management of high blood pressure in adults. JAMA 318, 2132\u20132134 (2017).","journal-title":"JAMA"},{"key":"73172_CR14","first-page":"e13","volume":"71","author":"PK Whelton","year":"2018","unstructured":"Whelton, P. K. et al. ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines. Hypertension 71, e13\u2013e115 (2018).","journal-title":"Hypertension"},{"key":"73172_CR15","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.1016\/j.jacc.2017.11.005","volume":"71","author":"PK Whelton","year":"2018","unstructured":"Whelton, P. K. et al. ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines. J. Am. Coll. Cardiol. 71, 2199\u20132269 (2018).","journal-title":"J. Am. Coll. Cardiol."},{"key":"73172_CR16","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1109\/JBHI.2016.2620995","volume":"20","author":"XR Ding","year":"2016","unstructured":"Ding, X. R. Continuous blood pressure measurement from invasive to unobtrusive: celebration of 200th birth anniversary of Carl-Ludwig. IEEE J. Biomed. Health Inform. 20, 1455\u20131465 (2016).","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"73172_CR17","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1161\/CIRCULATIONAHA.117.032582","volume":"137","author":"P Muntner","year":"2018","unstructured":"Muntner, P. et al. Potential US population impact of the 2017 American College of Cardiology\/American Heart Association High Blood Pressure Guideline. Circulation 137, 109\u2013118 (2018).","journal-title":"Circulation"},{"key":"73172_CR18","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1001\/jama.2017.19672","volume":"319","author":"JPA Ioannidis","year":"2018","unstructured":"Ioannidis, J. P. A. Diagnosis and treatment of hypertension in the 2017 ACC\/AHA guidelines and in the realworld. JAMA 319, 115\u2013116 (2018).","journal-title":"JAMA"},{"key":"73172_CR19","doi-asserted-by":"crossref","first-page":"e1000058","DOI":"10.1371\/journal.pmed.1000058","volume":"6","author":"G Danaei","year":"2009","unstructured":"Danaei, G. et al. The preventable causes of death in the United States: comparative risk assessment of dietary, lifestyle, and metabolic risk factors. PLoS Med. 6, e1000058 (2009).","journal-title":"PLoS Med."},{"key":"73172_CR20","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1001\/jamainternmed.2018.6551","volume":"179","author":"M Roerecke","year":"2019","unstructured":"Roerecke, M. et al. Comparing automated office blood pressure readings with other methods of blood pressure measurement for identifying patients with possible hypertension: a systematic review and meta-analysis. JAMA Intern. Med. 179, 351\u2013362 (2019).","journal-title":"JAMA Intern. Med."},{"key":"73172_CR21","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.cjca.2016.02.066","volume":"32","author":"AA Leung","year":"2016","unstructured":"Leung, A. A. et al. CHEP Guidelines Task Force. Hypertension Canada\u2019s 2016 Canadian Hypertension Education Program guidelines for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension. Can. J. Cardiol. 32, 569\u201388 (2016).","journal-title":"Can. J. Cardiol."},{"key":"73172_CR22","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.1097\/HJH.0b013e3283577b05","volume":"30","author":"MG Myers","year":"2012","unstructured":"Myers, M. G. The great myth of office blood pressure measurement. J. Hypertens. 30, 1894\u20131898 (2012).","journal-title":"J. Hypertens."},{"key":"73172_CR23","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/jch.12820","volume":"18","author":"MG Myers","year":"2016","unstructured":"Myers, M. G. A short history of automated office blood pressure\u201415 years to SPRINT. J. Clin. Hypertens. (Greenwich) 18, 721\u2013724 (2016).","journal-title":"J. Clin. Hypertens. (Greenwich)"},{"key":"73172_CR24","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.jash.2016.10.013","volume":"10","author":"A de la Sierra","year":"2016","unstructured":"de la Sierra, A. et al. Ambulatory blood pressure in hypertensive patients with inclusion criteria for the SPRINT trial. J. Am. Soc. Hypertens. 10, 947\u2013953 (2016).","journal-title":"J. Am. Soc. Hypertens."},{"key":"73172_CR25","unstructured":"ISO 81060-2:2013. Non-invasive Sphygmomanometers\u2014Part 2: Clinical Investigation of Automated Measurement Type. https:\/\/www.iso.org\/standard\/57977.html"},{"key":"73172_CR26","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155\u2013163 (2016).","journal-title":"J. Chiropr. Med."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73172-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73172-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73172-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T15:13:28Z","timestamp":1670339608000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73172-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,30]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["73172"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-73172-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,30]]},"assertion":[{"value":"7 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A.E., A.B.I. and R.L. are employed by Biobeat Technologies Ltd. All other authors report no potential conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16116"}}