{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T22:04:46Z","timestamp":1788559486322,"version":"build-2803163510"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T00:00:00Z","timestamp":1601424000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T00:00:00Z","timestamp":1601424000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Projekt DEAL"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The study investigated whether the use of carbon fiber-reinforced PEEK screw material (CF-PEEK) can reduce magnetic resonance imaging (MRI) artifact formation. Two consecutive groups of patients were treated for degenerative spinal disorders of the lumbar spine with dorsal transpedicular spinal fusion. The first group (n\u2009=\u200927) received titanium pedicle screws. The second group (n\u2009=\u200920) received CF-PEEK screws. All patients underwent an MRI assessment within the first four postoperative weeks. For each operated segment, the surface of the artifact-free vertebral body area was calculated as percentage of the total vertebral body. For each implanted segment, the assessability of the spinal canal, the neuroforamina, and the pedicle screws, as well as the surrounding bony and soft-tissue structures was graded from 1 to 5. A mean artifact-free vertebral body area of 48.3\u2009\u00b1\u20095.0% was found in the in the titanium group and of 67.1\u2009\u00b1\u20095.6% in the CF-PEEK group (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.01). Assessability of the lumbar spine was significantly improved for CF-PEEK screws (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.01) for all measurements. CF-PEEK pedicle screws exhibit smaller artifact areas on vertebral body surfaces and their surrounding tissues, which improves the radiographic assessability. Hence, CF-PEEK may provide a diagnostic benefit.<\/jats:p>","DOI":"10.1038\/s41598-020-73386-5","type":"journal-article","created":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T10:05:26Z","timestamp":1601460326000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Carbon fiber-reinforced pedicle screws reduce artifacts in magnetic resonance imaging of patients with lumbar spondylodesis"],"prefix":"10.1038","volume":"10","author":[{"given":"Christoph","family":"Fleege","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Makowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Rauschmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharina Luise","family":"Fraunhoffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Fennema","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Arabmotlagh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Rickert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,9,30]]},"reference":[{"key":"73386_CR1","doi-asserted-by":"publisher","first-page":"e13","DOI":"10.2106\/jbjs.Rvw.16.00120","volume":"5","author":"ID Kaye","year":"2017","unstructured":"Kaye, I. D., Prasad, S. K., Vaccaro, A. R. & Hilibrand, A. S. The cortical bone trajectory for pedicle screw insertion. JBJS Rev. 5, e13. https:\/\/doi.org\/10.2106\/jbjs.Rvw.16.00120 (2017).","journal-title":"JBJS Rev."},{"key":"73386_CR2","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1111\/os.12098","volume":"6","author":"PJ Rao","year":"2014","unstructured":"Rao, P. J., Pelletier, M. H., Walsh, W. R. & Mobbs, R. J. Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration. Orthop. Surg. 6, 81\u201389. https:\/\/doi.org\/10.1111\/os.12098 (2014).","journal-title":"Orthop. Surg."},{"key":"73386_CR3","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1016\/j.acra.2014.09.010","volume":"22","author":"LB Gutierrez","year":"2015","unstructured":"Gutierrez, L. B. et al. MR imaging near metallic implants using MAVRIC SL: initial clinical experience at 3T. Acad. Radiol. 22, 370\u2013379. https:\/\/doi.org\/10.1016\/j.acra.2014.09.010 (2015).","journal-title":"Acad. Radiol."},{"key":"73386_CR4","doi-asserted-by":"publisher","first-page":"93","DOI":"10.12659\/pjr.892628","volume":"80","author":"K Krupa","year":"2015","unstructured":"Krupa, K. & Bekiesi\u0144ska-Figatowska, M. Artifacts in magnetic resonance imaging. Pol. J. Radiol. 80, 93\u2013106. https:\/\/doi.org\/10.12659\/pjr.892628 (2015).","journal-title":"Pol. J. Radiol."},{"key":"73386_CR5","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.21595\/jve.2018.19756","volume":"20","author":"T Budrys","year":"2018","unstructured":"Budrys, T. et al. Artifacts in magnetic resonance imaging: how it can really affect diagnostic image quality and confuse clinical diagnosis?. J. Vibroeng. 20, 1202\u20131213 (2018).","journal-title":"J. Vibroeng."},{"key":"73386_CR6","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1002\/mrm.21967","volume":"62","author":"W Lu","year":"2009","unstructured":"Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M. & Hargreaves, B. A. SEMAC: slice encoding for metal artifact correction in MRI. Magn. Reson. Med. 62, 66\u201376. https:\/\/doi.org\/10.1002\/mrm.21967 (2009).","journal-title":"Magn. Reson. Med."},{"key":"73386_CR7","doi-asserted-by":"publisher","first-page":"W405","DOI":"10.2214\/ajr.11.6659","volume":"197","author":"CL Hayter","year":"2011","unstructured":"Hayter, C. L. et al. MRI after arthroplasty: comparison of MAVRIC and conventional fast spin-echo techniques. AJR Am. J. Roentgenol. 197, W405-411. https:\/\/doi.org\/10.2214\/ajr.11.6659 (2011).","journal-title":"AJR Am. J. Roentgenol."},{"key":"73386_CR8","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz, S. M. & Devine, J. N. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28, 4845\u20134869 (2007).","journal-title":"Biomaterials"},{"key":"73386_CR9","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.wneu.2017.04.091","volume":"105","author":"F Ringel","year":"2017","unstructured":"Ringel, F. et al. Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg. 105, 294\u2013301. https:\/\/doi.org\/10.1016\/j.wneu.2017.04.091 (2017).","journal-title":"World Neurosurg."},{"key":"73386_CR10","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1007\/s00586-018-5538-8","volume":"27","author":"RA Lindtner","year":"2018","unstructured":"Lindtner, R. A., Schmid, R., Nydegger, T., Konschake, M. & Schmoelz, W. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading. Eur. Spine J. 27, 1775\u20131784. https:\/\/doi.org\/10.1007\/s00586-018-5538-8 (2018).","journal-title":"Eur. Spine J."},{"key":"73386_CR11","unstructured":"Egermann, M., Tanner, M. & Lehner, B. In Deutscher Kongress f\u00fcr Orthop\u00e4die und Unfallchirurgie (DKOU) (Berlin, 2012)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73386-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73386-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73386-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T20:04:36Z","timestamp":1670357076000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-73386-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,30]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["73386"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-73386-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,30]]},"assertion":[{"value":"12 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16094"}}