{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T11:08:58Z","timestamp":1780571338535,"version":"3.54.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T00:00:00Z","timestamp":1610496000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T00:00:00Z","timestamp":1610496000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2017R1D1A1B03035355"],"award-info":[{"award-number":["2017R1D1A1B03035355"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Using either 24-2 or 10-2 visual field (VF) testing only is not enough to cover all the various types of glaucomatous VF defects. We investigated the performance of the combined 24-2 and 10-2 perimetry when conducted together and separately using the structure\u2013function relationship. A total of 30 glaucoma patients with isolated peripheral nasal step, 37 patients with isolated paracentral scotoma, and 38 patients with both paracentral and nasal scotoma were included. To create the combined Humphrey VF test, a custom test pattern was established using the built-in custom point options, an example of the X, Y coordinate system. In glaucoma patients with peripheral nasal step, the superotemporal topographic structure\u2013function relationship with peripapillary retinal nerve fiber layer (RNFL) thickness was superior in relation to the combined or 24-2 perimetry relative to the 10-2 perimetry (both P\u2009&lt;\u20090.05). The combined VF test showed more favorable inferotemporal or inferonasal structure\u2013function correlation with the corresponding ganglion cell\u2013inner plexiform layer (GCIPL) thickness when compared with results gleaned using the 24-2 VF test (P\u2009&lt;\u20090.05). Simultaneously performed 24-2 and 10-2 VF tests demonstrated a superior topographic structure\u2013function relationship when compared with them separately performed in some sectors.<\/jats:p>","DOI":"10.1038\/s41598-020-80318-w","type":"journal-article","created":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T11:15:21Z","timestamp":1610536521000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Simultaneously performed combined 24-2 and 10-2 visual field tests in glaucoma"],"prefix":"10.1038","volume":"11","author":[{"given":"Kyoung In","family":"Jung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hee Kyung","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki Hoon","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong Chan","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chan Kee","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,13]]},"reference":[{"key":"80318_CR1","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/S0002-9394(00)00352-4","volume":"129","author":"WL Alward","year":"2000","unstructured":"Alward, W. L. Frequency doubling technology perimetry for the detection of glaucomatous visual field loss. Am. J. Ophthalmol. 129, 376\u2013378 (2000).","journal-title":"Am. J. Ophthalmol."},{"key":"80318_CR2","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1001\/jamaophthalmol.2013.7656","volume":"132","author":"I Traynis","year":"2014","unstructured":"Traynis, I. et al. Prevalence and nature of early glaucomatous defects in the central 10 degrees of the visual field. JAMA Ophthalmol. 132, 291\u2013297. https:\/\/doi.org\/10.1001\/jamaophthalmol.2013.7656 (2014).","journal-title":"JAMA Ophthalmol."},{"key":"80318_CR3","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1016\/j.ophtha.2017.04.021","volume":"124","author":"CG De Moraes","year":"2017","unstructured":"De Moraes, C. G. et al. 24-2 visual fields miss central defects shown on 10-2 tests in glaucoma suspects, ocular hypertensives, and early glaucoma. Ophthalmology 124, 1449\u20131456. https:\/\/doi.org\/10.1016\/j.ophtha.2017.04.021 (2017).","journal-title":"Ophthalmology"},{"key":"80318_CR4","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1167\/tvst.3.6.6","volume":"3","author":"AC Ehrlich","year":"2014","unstructured":"Ehrlich, A. C., Raza, A. S., Ritch, R. & Hood, D. C. Modifying the conventional visual field test pattern to improve the detection of early glaucomatous defects in the central 10 degrees. Transl. Vis. Sci. Technol. 3, 6. https:\/\/doi.org\/10.1167\/tvst.3.6.6 (2014).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"80318_CR5","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.ajo.2020.06.024","volume":"219","author":"J Phu","year":"2020","unstructured":"Phu, J. & Kalloniatis, M. Ability of 24-2C and 24-2 grids to identify central visual field defects and structure-function concordance in glaucoma and suspects. Am. J. Ophthalmol. 219, 317\u2013331. https:\/\/doi.org\/10.1016\/j.ajo.2020.06.024 (2020).","journal-title":"Am. J. Ophthalmol."},{"key":"80318_CR6","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1097\/IJG.0b013e31822af27a","volume":"21","author":"MT Leite","year":"2012","unstructured":"Leite, M. T. et al. Structure-function relationships using the Cirrus spectral domain optical coherence tomograph and standard automated perimetry. J. Glaucoma. 21, 49\u201354. https:\/\/doi.org\/10.1097\/IJG.0b013e31822af27a (2012).","journal-title":"J. Glaucoma."},{"key":"80318_CR7","first-page":"2213","volume":"43","author":"DF Garway-Heath","year":"2002","unstructured":"Garway-Heath, D. F., Holder, G. E., Fitzke, F. W. & Hitchings, R. A. Relationship between electrophysiological, psychophysical, and anatomical measurements in glaucoma. Invest. Ophthalmol. Vis. Sci. 43, 2213\u20132220 (2002).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"80318_CR8","first-page":"1","volume-title":"The design and Analysis of Clinical Experiments","author":"JL Fleiss","year":"1986","unstructured":"Fleiss, J. L. The design and Analysis of Clinical Experiments 1\u201332 (Wiley, Hoboken, 1986)."},{"key":"80318_CR9","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1016\/j.ophtha.2013.01.045","volume":"120","author":"SC Park","year":"2013","unstructured":"Park, S. C. et al. Parafoveal scotoma progression in glaucoma: humphrey 10-2 versus 24-2 visual field analysis. Ophthalmology 120, 1546\u20131550. https:\/\/doi.org\/10.1016\/j.ophtha.2013.01.045 (2013).","journal-title":"Ophthalmology"},{"key":"80318_CR10","first-page":"268","volume":"35","author":"C Hudson","year":"1994","unstructured":"Hudson, C., Wild, J. M. & O\u2019Neill, E. C. Fatigue effects during a single session of automated static threshold perimetry. Invest. Ophthalmol. Vis. Sci. 35, 268\u2013280 (1994).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"80318_CR11","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/s0161-6420(91)32231-0","volume":"98","author":"AE Searle","year":"1991","unstructured":"Searle, A. E., Wild, J. M., Shaw, D. E. & O\u2019Neill, E. C. Time-related variation in normal automated static perimetry. Ophthalmology 98, 701\u2013707. https:\/\/doi.org\/10.1016\/s0161-6420(91)32231-0 (1991).","journal-title":"Ophthalmology"},{"key":"80318_CR12","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1167\/iovs.08-1789","volume":"50","author":"M Wall","year":"2009","unstructured":"Wall, M., Woodward, K. R., Doyle, C. K. & Artes, P. H. Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry. Invest. Ophthalmol. Vis. Sci. 50, 974\u2013979. https:\/\/doi.org\/10.1167\/iovs.08-1789 (2009).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"80318_CR13","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1034\/j.1600-0420.1999.770205.x","volume":"77","author":"B Bengtsson","year":"1999","unstructured":"Bengtsson, B. & Heijl, A. Comparing significance and magnitude of glaucomatous visual field defects using the SITA and full threshold strategies. Acta Ophthalmol. Scand. 77, 143\u2013146. https:\/\/doi.org\/10.1034\/j.1600-0420.1999.770205.x (1999).","journal-title":"Acta Ophthalmol. Scand."},{"key":"80318_CR14","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/00061198-200002000-00005","volume":"9","author":"AK Sharma","year":"2000","unstructured":"Sharma, A. K., Goldberg, I., Graham, S. L. & Mohsin, M. Comparison of the Humphrey swedish interactive thresholding algorithm (SITA) and full threshold strategies. J. Glaucoma 9, 20\u201327. https:\/\/doi.org\/10.1097\/00061198-200002000-00005 (2000).","journal-title":"J. Glaucoma"},{"key":"80318_CR15","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1001\/archopht.120.9.1136","volume":"120","author":"DL Budenz","year":"2002","unstructured":"Budenz, D. L. et al. Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms. Arch Ophthalmol. 120, 1136\u20131141. https:\/\/doi.org\/10.1001\/archopht.120.9.1136 (2002).","journal-title":"Arch Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-80318-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-80318-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-80318-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T02:12:12Z","timestamp":1670033532000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-80318-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,13]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["80318"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-80318-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,13]]},"assertion":[{"value":"11 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1227"}}