{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T20:12:13Z","timestamp":1788984733540,"version":"build-2803163510"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,10,26]],"date-time":"2021-10-26T00:00:00Z","timestamp":1635206400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,26]],"date-time":"2021-10-26T00:00:00Z","timestamp":1635206400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Glaucoomfonds, Oogfonds, Rotterdamse Stichting Blindenbelangen, and Stichting Blindenhulp contributed through UitZicht."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study described the development of a haploscope-based pupillometer for the parametrization of the Pupillary Light Reflex (PLR), and its feasibility in a set of 30 healthy subjects (light or dark-colored irides) and five patients diagnosed with Relative Afferent Pupillary Defect (RAPD). Our supplementary aim focused on evaluating the influence of iris colour on the PLR to decide whether a difference in PLR parameters should be anticipated when this system is used across ethnicities. All the participants underwent a customized pupillometry protocol and the generated pupil traces, captured by an eye tracker, were analyzed using exponential fits to derive PLR parameters. A Pupil Response Symmetry (PRS) coefficient was calculated to predict the presence of RAPD. The mean (SD) Initial PD during dilation (3.2 (0.5) mm) and the minimum PD during constriction (2.9 (0.4) mm) in the light iris group had a statistically significant (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) higher magnitude compared to the dark iris group. The normal limits of the PRS coefficient ranged from\u2009\u2212\u20090.20 to\u2009+\u20091.07 and all RAPD patients were outside the calculated normal limits. This proposed system, analysis strategies, and the tested metrics showed good short-term repeatability and the potential in detecting pupil abnormalities in neuro-ophthalmic diseases.<\/jats:p>","DOI":"10.1038\/s41598-021-00434-z","type":"journal-article","created":{"date-parts":[[2021,10,26]],"date-time":"2021-10-26T10:02:49Z","timestamp":1635242569000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A haploscope based binocular pupillometer system to quantify the dynamics of direct and consensual Pupillary Light Reflex"],"prefix":"10.1038","volume":"11","author":[{"given":"Najiya S. K.","family":"Meethal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepmala","family":"Mazumdar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergii","family":"Morshchavka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasper","family":"Robben","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"van der Steen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronnie","family":"George","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johan J. M.","family":"Pel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,26]]},"reference":[{"issue":"1","key":"434_CR1","first-page":"439","volume":"5","author":"DH McDougal","year":"2015","unstructured":"McDougal, D. H. & Gamlin, P. D. Autonomic control of the eye. Compr. Physiol. 5(1), 439 (2015).","journal-title":"Compr. Physiol."},{"key":"434_CR2","doi-asserted-by":"crossref","unstructured":"Math\u00f4t, S. Pupillometry: Psychology, physiology, and function. J. Cognit. 2018; 1(1).","DOI":"10.5334\/joc.18"},{"issue":"11","key":"434_CR3","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1038\/sj.eye.6701560","volume":"18","author":"FD Bremner","year":"2004","unstructured":"Bremner, F. D. Pupil assessment in optic nerve disorders. Eye 18(11), 1175\u20131181 (2004).","journal-title":"Eye"},{"issue":"6","key":"434_CR4","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/0042-6989(75)90279-5","volume":"15","author":"JM Woodhouse","year":"1975","unstructured":"Woodhouse, J. M. & Campbell, F. W. The role of the pupil light reflex in aiding adaptation to the dark. Vis. Res. 15(6), 649\u2013653 (1975).","journal-title":"Vis. Res."},{"issue":"3","key":"434_CR5","first-page":"1132","volume":"35","author":"B Winn","year":"1994","unstructured":"Winn, B., Whitaker, D., Elliott, D. B. & Phillips, N. J. Factors affecting light-adapted pupil size in normal human subjects. Investig. Ophthalmol. Vis. Sci. 35(3), 1132\u20131137 (1994).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"issue":"5","key":"434_CR6","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1001\/archopht.1959.04220050030005","volume":"62","author":"P Levatin","year":"1959","unstructured":"Levatin, P. Pupillary escape in disease of the retina or optic nerve. A.M.A. Arch. Ophthalmol. 62(5), 768\u2013779 (1959).","journal-title":"A.M.A. Arch. Ophthalmol."},{"issue":"2","key":"434_CR7","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1212\/WNL.54.2.530","volume":"54","author":"I Litvan","year":"2000","unstructured":"Litvan, I. et al. Pupillary diameter assessment: need for a graded scale. Neurology 54(2), 530 (2000).","journal-title":"Neurology"},{"issue":"1","key":"434_CR8","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1097\/01376517-200502000-00006","volume":"37","author":"M Meeker","year":"2005","unstructured":"Meeker, M., Du, R., Bacchetti, P. & Privitera, C. M. Pupil examination: validity and clinical utility of an automated pupillometer. J. Neurosci. Nurs. 37(1), 34 (2005).","journal-title":"J. Neurosci. Nurs."},{"issue":"1","key":"434_CR9","doi-asserted-by":"publisher","first-page":"19","DOI":"10.3390\/diagnostics8010019","volume":"8","author":"CA Hall","year":"2018","unstructured":"Hall, C. A. & Chilcott, R. P. Eyeing up the future of the pupillary light reflex in neurodiagnostics. Diagnostics. 8(1), 19 (2018).","journal-title":"Diagnostics."},{"issue":"6","key":"434_CR10","doi-asserted-by":"publisher","first-page":"611","DOI":"10.3758\/BF03210585","volume":"21","author":"A Radzius","year":"1989","unstructured":"Radzius, A., Welch, P., Cone, E. J. & Henningfield, J. E. A portable pupillometer system for measuring pupillary size and light reflex. Behav. Res. Methods Instrum. Comput. 21(6), 611\u2013618 (1989).","journal-title":"Behav. Res. Methods Instrum. Comput."},{"issue":"1","key":"434_CR11","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1186\/2193-1801-3-548","volume":"3","author":"JW Chen","year":"2014","unstructured":"Chen, J. W., Vakil-Gilani, K., Williamson, K. L. & Cecil, S. Infrared pupillometry, the Neurological Pupil index and unilateral pupillary dilation after traumatic brain injury: implications for treatment paradigms. Springerplus 3(1), 548 (2014).","journal-title":"Springerplus"},{"issue":"2","key":"434_CR12","doi-asserted-by":"publisher","first-page":"720","DOI":"10.3892\/etm.2016.3379","volume":"12","author":"YD Shin","year":"2016","unstructured":"Shin, Y. D. et al. Assessment of pupillary light reflex using a smartphone application. Exp. Ther. Med. 12(2), 720\u2013724 (2016).","journal-title":"Exp. Ther. Med."},{"key":"434_CR13","doi-asserted-by":"crossref","unstructured":"Martin, J. T., Pinto, J., Bulte, D. P. & Spitschan, M. PyPlr: A versatile, integrated system of hardware and software for researching the human pupillary light reflex. bioRxiv. 2021 Jan 1.","DOI":"10.1101\/2021.06.02.446731"},{"issue":"1","key":"434_CR14","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/1475-925X-13-69","volume":"13","author":"W Nowak","year":"2014","unstructured":"Nowak, W., \u017barowska, A., Szul-Pietrzak, E. & Misiuk-Hoj\u0142o, M. System and measurement method for binocular pupillometry to study pupil size variability. Biomed. Eng. Online 13(1), 69 (2014).","journal-title":"Biomed. Eng. Online"},{"issue":"4","key":"434_CR15","first-page":"619","volume":"34","author":"WI Szczepanowska-Nowak","year":"2004","unstructured":"Szczepanowska-Nowak, W. I., Hachol, A. & Kasprzak, H. System for measurement of the consensual pupil light reflex. Opt. Appl. 34(4), 619\u2013634 (2004).","journal-title":"Opt. Appl."},{"issue":"6","key":"434_CR16","doi-asserted-by":"publisher","first-page":"299","DOI":"10.3109\/01658108808996058","volume":"8","author":"JE Bos","year":"1988","unstructured":"Bos, J. E. Clinical quantitative pupillometry: The latency of pupillary constriction as measured with the IRIS system (preliminary results). Neuro-Ophthalmology 8(6), 299\u2013305 (1988).","journal-title":"Neuro-Ophthalmology"},{"issue":"5","key":"434_CR17","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1111\/cxo.12659","volume":"101","author":"K Tekin","year":"2018","unstructured":"Tekin, K. et al. Static and dynamic pupillometry data of healthy individuals. Clin. Exp. Optom. 101(5), 659\u2013665 (2018).","journal-title":"Clin. Exp. Optom."},{"issue":"11","key":"434_CR18","doi-asserted-by":"publisher","first-page":"7343","DOI":"10.1167\/iovs.12-10881","volume":"53","author":"FD Bremner","year":"2012","unstructured":"Bremner, F. D. Pupillometric evaluation of the dynamics of the pupillary response to a brief light stimulus in healthy subjects. Investig. Ophthalmol. Vis. Sci. 53(11), 7343\u20137347 (2012).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"issue":"2","key":"434_CR19","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/WNO.0b013e31823f45e5","volume":"32","author":"A Shwe-Tin","year":"2012","unstructured":"Shwe-Tin, A., Smith, G. T., Checketts, D., Murdoch, I. E. & Taylor, D. Evaluation and calibration of a binocular infrared pupillometer for measuring relative afferent pupillary defect. J. Neuroophthalmol. 32(2), 111\u2013115 (2012).","journal-title":"J. Neuroophthalmol."},{"issue":"11","key":"434_CR20","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.3109\/02713683.2014.980007","volume":"40","author":"LM Cohen","year":"2015","unstructured":"Cohen, L. M., Rosenberg, M. A., Tanna, A. P. & Volpe, N. J. A novel computerized portable pupillometer detects and quantifies relative afferent pupillary defects. Curr. Eye Res. 40(11), 1120\u20131127 (2015).","journal-title":"Curr. Eye Res."},{"issue":"12","key":"434_CR21","doi-asserted-by":"publisher","first-page":"2551","DOI":"10.1016\/j.jcrs.2004.05.025","volume":"30","author":"S Kurz","year":"2004","unstructured":"Kurz, S., Krummenauer, F., Pfeiffer, N. & Dick, H. B. Monocular versus binocular pupillometry. J. Cataract Refract. Surg. 30(12), 2551\u20132556 (2004).","journal-title":"J. Cataract Refract. Surg."},{"issue":"6","key":"434_CR22","doi-asserted-by":"publisher","first-page":"e20910","DOI":"10.1371\/journal.pone.0020910","volume":"6","author":"M Naber","year":"2011","unstructured":"Naber, M., Fr\u00e4ssle, S. & Einh\u00e4user, W. Perceptual rivalry: reflexes reveal the gradual nature of visual awareness. PLoS ONE 6(6), e20910 (2011).","journal-title":"PLoS ONE"},{"issue":"4","key":"434_CR23","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.3758\/s13428-016-0805-2","volume":"49","author":"JW Brascamp","year":"2017","unstructured":"Brascamp, J. W. & Naber, M. Eye tracking under dichoptic viewing conditions: a practical solution. Behav. Res. Methods 49(4), 1303\u20131309 (2017).","journal-title":"Behav. Res. Methods"},{"issue":"5","key":"434_CR24","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.jaapos.2008.01.019","volume":"12","author":"NA Ramey","year":"2008","unstructured":"Ramey, N. A. et al. A novel haploscopic viewing apparatus with a three-axis eye tracker. J. Am. Assoc. Pediatr. Ophthalmol. Strabismus. 12(5), 498\u2013503 (2008).","journal-title":"J. Am. Assoc. Pediatr. Ophthalmol. Strabismus."},{"issue":"2","key":"434_CR25","doi-asserted-by":"publisher","first-page":"189","DOI":"10.3928\/1081-597X-20020301-15","volume":"18","author":"RS Vaswani","year":"2002","unstructured":"Vaswani, R. S., Mudgil, A. V. & Gleicher, D. Correlation of pupil size to iris colour in children. J. Refract. Surg. 18(2), 189\u2013189 (2002).","journal-title":"J. Refract. Surg."},{"issue":"4\u20135","key":"434_CR26","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1111\/j.1444-0938.2004.tb05061.x","volume":"87","author":"SJ Dain","year":"2004","unstructured":"Dain, S. J., Cassimaty, V. T. & Psarakis, D. T. Differences in FM100-Hue test performance related to iris colour may be due to pupil size as well as presumed amounts of macular pigmentation. Clin. Exp. Optom. 87(4\u20135), 322\u2013325 (2004).","journal-title":"Clin. Exp. Optom."},{"issue":"8","key":"434_CR27","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1007\/s004170050122","volume":"236","author":"O Bergamin","year":"1998","unstructured":"Bergamin, O., Schoetzau, A., Sugimoto, K. & Zulauf, M. The influence of iris colour on the pupillary light reflex. Graefes Arch. Clin. Exp. Ophthalmol. 236(8), 567\u2013570 (1998).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"issue":"4","key":"434_CR28","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1089\/jop.2010.0061","volume":"26","author":"JC Bradley","year":"2010","unstructured":"Bradley, J. C. et al. The effect of gender and iris colour on the dark-adapted pupil diameter. J. Ocul. Pharmacol. Ther. 26(4), 335\u2013340 (2010).","journal-title":"J. Ocul. Pharmacol. Ther."},{"issue":"20","key":"434_CR29","doi-asserted-by":"publisher","first-page":"2191","DOI":"10.1001\/jama.2013.281053","volume":"310","author":"H Declaration","year":"2013","unstructured":"Declaration, H. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA 310(20), 2191\u20132194 (2013).","journal-title":"JAMA"},{"issue":"14","key":"434_CR30","first-page":"1","volume":"36","author":"M Kleiner","year":"2007","unstructured":"Kleiner, M. et al. What\u2019s new in Psychtoolbox-3. Perception 36(14), 1 (2007).","journal-title":"Perception"},{"issue":"5","key":"434_CR31","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1080\/713818582","volume":"19","author":"FS Said","year":"1972","unstructured":"Said, F. S. & Sawires, W. S. Age dependence of changes in pupil diameter in the dark. Optica Acta: Int. J. Opt. 19(5), 359\u2013361 (1972).","journal-title":"Optica Acta: Int. J. Opt."},{"issue":"6","key":"434_CR32","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0886-3350(00)00486-7","volume":"26","author":"EM Schnitzler","year":"2000","unstructured":"Schnitzler, E. M., Baumeister, M. & Kohnen, T. Scotopic measurement of normal pupils: Colvard versus Video Vision Analyzer infrared pupillometer. J. Cataract Refract. Surg. 26(6), 859\u2013866 (2000).","journal-title":"J. Cataract Refract. Surg."},{"issue":"3","key":"434_CR33","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1080\/01658107.2017.1367012","volume":"42","author":"G Takizawa","year":"2018","unstructured":"Takizawa, G. et al. Relative afferent pupillary defects in homonymous visual field defects caused by stroke of the occipital lobe using pupillometer. Neuro-Ophthalmology 42(3), 139\u2013145 (2018).","journal-title":"Neuro-Ophthalmology"},{"issue":"2","key":"434_CR34","doi-asserted-by":"publisher","first-page":"227","DOI":"10.4103\/ijo.IJO_648_18","volume":"67","author":"MR Pillai","year":"2019","unstructured":"Pillai, M. R., Sinha, S., Aggarwal, P., Ravindran, R. D. & Privitera, C. M. Quantification of RAPD by an automated pupillometer in asymmetric glaucoma and its correlation with manual pupillary assessment. Indian J. Ophthalmol. 67(2), 227 (2019).","journal-title":"Indian J. Ophthalmol."},{"issue":"3","key":"434_CR35","doi-asserted-by":"publisher","first-page":"033355","DOI":"10.1103\/PhysRevResearch.2.033355","volume":"2","author":"A Sarracino","year":"2020","unstructured":"Sarracino, A., Arviv, O., Shriki, O. & de Arcangelis, L. Predicting brain evoked response to external stimuli from temporal correlations of spontaneous activity. Phys. Rev. Res. 2(3), 033355 (2020).","journal-title":"Phys. Rev. Res."},{"issue":"4","key":"434_CR36","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1167\/iovs.02-0468","volume":"44","author":"O Bergamin","year":"2003","unstructured":"Bergamin, O. & Kardon, R. H. Latency of the pupil light reflex: sample rate, stimulus intensity, and variation in normal subjects. Investig. Ophthalmol. Vis. Sci. 44(4), 1546\u20131554 (2003).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"issue":"11","key":"434_CR37","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1136\/bjo.65.11.754","volume":"65","author":"CJ Ellis","year":"1981","unstructured":"Ellis, C. J. The pupillary light reflex in normal subjects. Br. J. Ophthalmol. 65(11), 754\u2013759 (1981).","journal-title":"Br. J. Ophthalmol."},{"issue":"10","key":"434_CR38","doi-asserted-by":"publisher","first-page":"76","DOI":"10.3389\/fneur.2019.00076","volume":"12","author":"AV Rukmini","year":"2019","unstructured":"Rukmini, A. V., Milea, D. & Gooley, J. J. Chromatic pupillometry methods for assessing photoreceptor health in retinal and optic nerve diseases. Front. Neurol. 12(10), 76 (2019).","journal-title":"Front. Neurol."},{"issue":"7","key":"434_CR39","doi-asserted-by":"publisher","first-page":"4496","DOI":"10.1167\/iovs.14-14103","volume":"55","author":"S Lei","year":"2014","unstructured":"Lei, S., Goltz, H. C., Chandrakumar, M. & Wong, A. M. Full-field chromatic pupillometry for the assessment of the postillumination pupil response driven by melanopsin-containing retinal ganglion cells. Investig. Ophthalmol. Vis. Sci. 55(7), 4496\u20134503 (2014).","journal-title":"Investig. Ophthalmol. Vis. Sci."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-00434-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-00434-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-00434-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T16:54:07Z","timestamp":1670086447000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-00434-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,26]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["434"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-00434-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,26]]},"assertion":[{"value":"1 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21090"}}