{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T10:20:13Z","timestamp":1788258013323,"version":"build-2803163510"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>To elucidate the accuracy, efficacy, and safety of percutaneous iliosacral screw (ISS) and trans-iliac trans-sacral screw (TITS) insertion using a single C-arm fluoroscopy intensifier. Additionally, the potential risk factors that might cause mal-positioned screws were identified. Patients with pelvic ring injuries who underwent percutaneous screw fixation in a single medical institute were divided into an ISS group (n\u2009=\u200959) and a TITS group (n\u2009=\u200962) and assessed. The angles deviated from ideal orientation (ADIO) of the implanted screw were measured, and potential risk factors for mal-positioned screws were analyzed. Overall, the reduction quality of the pelvic ring was good or excellent in 70 patients (82.4%) by Matta\u2019s criteria and in 48 patients (56.5%) by Lefaivre\u2019s criteria. ADIO measurements of the ISS and TITS groups via multi-planar computed tomography were 9.16\u00b0\u2009\u00b1\u20096.97\u00b0 and 3.09\u00b0\u2009\u00b1\u20092.8\u00b0 in the axial view, respectively, and 5.92\u00b0\u2009\u00b1\u20093.65\u00b0 and 2.10\u00b0\u2009\u00b1\u20092.01\u00b0 in the coronal view, respectively. Univariate statistical analysis revealed body mass index as the single potential risk factor of mal-positioned screws. With careful preoperative planning and intraoperative preparations, placing ISS and TITS under the guidance of single C-arm fluoroscopy intensifier is a reliable and safe technique. Caution should be exercised when performing this procedure in patients with a high body mass index.<\/jats:p>","DOI":"10.1038\/s41598-021-04351-z","type":"journal-article","created":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T06:04:32Z","timestamp":1641794672000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries"],"prefix":"10.1038","volume":"12","author":[{"given":"Jui-Ping","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping-Jui","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-Yi","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.-Chuan","family":"Tseng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying-Chao","family":"Chou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.-Jung","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pai-Wei","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Hsun","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,10]]},"reference":[{"key":"4351_CR1","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.accpm.2018.12.003","volume":"38","author":"P Incagnoli","year":"2019","unstructured":"Incagnoli, P. et al. Early management of severe pelvic injury (first 24 hours). Anaesth. Crit. Care Pain Med. 38, 199\u2013207. https:\/\/doi.org\/10.1016\/j.accpm.2018.12.003 (2019).","journal-title":"Anaesth. Crit. Care Pain Med."},{"key":"4351_CR2","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1097\/01.ta.0000242259.67486.15","volume":"63","author":"PV Giannoudis","year":"2007","unstructured":"Giannoudis, P. V. et al. Prevalence of pelvic fractures, associated injuries, and mortality: The United Kingdom perspective. J. Trauma 63, 875\u2013883. https:\/\/doi.org\/10.1097\/01.ta.0000242259.67486.15 (2007).","journal-title":"J. Trauma"},{"key":"4351_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.aju.2014.08.006","volume":"13","author":"A Alwaal","year":"2015","unstructured":"Alwaal, A. et al. The incidence, causes, mechanism, risk factors, classification, and diagnosis of pelvic fracture urethral injury. Arab. J. Urol. 13, 2\u20136. https:\/\/doi.org\/10.1016\/j.aju.2014.08.006 (2015).","journal-title":"Arab. J. Urol."},{"key":"4351_CR4","doi-asserted-by":"publisher","first-page":"S283","DOI":"10.1097\/00007632-199106001-00021","volume":"16","author":"SI Esses","year":"1991","unstructured":"Esses, S. I., Botsford, D. J., Huler, R. J. & Rauschning, W. Surgical anatomy of the sacrum. A guide for rational screw fixation. Spine (Phila Pa 1976) 16, S283\u2013S288. https:\/\/doi.org\/10.1097\/00007632-199106001-00021 (1991).","journal-title":"Spine (Phila Pa 1976)"},{"key":"4351_CR5","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57030204","author":"G Petryla","year":"2021","unstructured":"Petryla, G. et al. Comparison of one-year functional outcomes and quality of life between posterior pelvic ring fixation and combined anterior\u2013posterior pelvic ring fixation after lateral compression (B2 type) pelvic fracture. Medicina (Kaunas) https:\/\/doi.org\/10.3390\/medicina57030204 (2021).","journal-title":"Medicina (Kaunas)"},{"key":"4351_CR6","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1097\/TA.0b013e3181ef9ce1","volume":"69","author":"L Flint","year":"2010","unstructured":"Flint, L. & Cryer, H. G. Pelvic fracture: The last 50 years. J. Trauma 69, 483\u2013488. https:\/\/doi.org\/10.1097\/TA.0b013e3181ef9ce1 (2010).","journal-title":"J. Trauma"},{"key":"4351_CR7","doi-asserted-by":"publisher","first-page":"1502","DOI":"10.1097\/TA.0b013e318246efe5","volume":"72","author":"JA Bishop","year":"2012","unstructured":"Bishop, J. A. & Routt, M. L. Jr. Osseous fixation pathways in pelvic and acetabular fracture surgery: Osteology, radiology, and clinical applications. J. Trauma Acute Care Surg. 72, 1502\u20131509. https:\/\/doi.org\/10.1097\/TA.0b013e318246efe5 (2012).","journal-title":"J. Trauma Acute Care Surg."},{"key":"4351_CR8","doi-asserted-by":"publisher","first-page":"S18","DOI":"10.1097\/BOT.0000000000001252","volume":"32","author":"RD Wright Jr","year":"2018","unstructured":"Wright, R. D. Jr. Indications for open reduction internal fixation of anterior pelvic ring disruptions. J. Orthop. Trauma 32, S18-23. https:\/\/doi.org\/10.1097\/BOT.0000000000001252 (2018).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR9","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1097\/00005131-200005000-00007","volume":"14","author":"DA Carlson","year":"2000","unstructured":"Carlson, D. A., Scheid, D. K., Maar, D. C., Baele, J. R. & Kaehr, D. M. Safe placement of S1 and S2 iliosacral screws: The \u201cvestibule\u201d concept. J. Orthop. Trauma 14, 264\u2013269. https:\/\/doi.org\/10.1097\/00005131-200005000-00007 (2000).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR10","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1016\/j.injury.2014.10.052","volume":"45","author":"L Zhang","year":"2014","unstructured":"Zhang, L., Peng, Y., Du, C. & Tang, P. Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: A finite element analysis. Injury 45, 2055\u20132059. https:\/\/doi.org\/10.1016\/j.injury.2014.10.052 (2014).","journal-title":"Injury"},{"key":"4351_CR11","doi-asserted-by":"publisher","first-page":"E181","DOI":"10.1097\/BSD.0000000000000241","volume":"28","author":"VH Le","year":"2015","unstructured":"Le, V. H. et al. Biomechanical evaluation of supplemental percutaneous lumbo-sacro-iliac screws for spinopelvic fixation following total sacrectomy. J. Spinal Disord. Tech. 28, E181\u2013E185. https:\/\/doi.org\/10.1097\/BSD.0000000000000241 (2015).","journal-title":"J. Spinal Disord. Tech."},{"key":"4351_CR12","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1093\/occmed\/kqi048","volume":"55","author":"G Mastrangelo","year":"2005","unstructured":"Mastrangelo, G. et al. Increased cancer risk among surgeons in an orthopaedic hospital. Occup. Med. (Lond.) 55, 498\u2013500. https:\/\/doi.org\/10.1093\/occmed\/kqi048 (2005).","journal-title":"Occup. Med. (Lond.)"},{"key":"4351_CR13","doi-asserted-by":"crossref","first-page":"208","DOI":"10.55095\/achot2013\/033","volume":"80","author":"T Pavelka","year":"2013","unstructured":"Pavelka, T., Sal\u00e1\u0161ek, M. & Weisov\u00e1, D. Complications associated with surgical treatment of pelvic ring fractures. Acta Chir. Orthop. Traumatol. Cech. 80, 208\u2013215 (2013).","journal-title":"Acta Chir. Orthop. Traumatol. Cech."},{"key":"4351_CR14","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.722","volume":"8","author":"A Comai","year":"2016","unstructured":"Comai, A., Zatelli, M., Haglmuller, T. & Bonatti, G. The role of transcatheter arterial embolization in traumatic pelvic hemorrhage: Not only pelvic fracture. Cureus 8, e722. https:\/\/doi.org\/10.7759\/cureus.722 (2016).","journal-title":"Cureus"},{"key":"4351_CR15","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/00003086-198905000-00009","volume":"242","author":"JM Matta","year":"1989","unstructured":"Matta, J. M. & Saucedo, T. Internal fixation of pelvic ring fractures. Clin. Orthop. Relat. Res. 242, 83\u201397 (1989).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"4351_CR16","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1097\/01.ta.0000200860.01931.9a","volume":"60","author":"KT Peng","year":"2006","unstructured":"Peng, K. T., Huang, K. C., Chen, M. C., Li, Y. Y. & Hsu, R. W. Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: Comparison between one and two C-arm fluoroscopic techniques. J. Trauma 60, 602\u2013608. https:\/\/doi.org\/10.1097\/01.ta.0000200860.01931.9a (2006).","journal-title":"J. Trauma"},{"key":"4351_CR17","doi-asserted-by":"publisher","first-page":"309","DOI":"10.17392\/1326-21","volume":"18","author":"G Ciolli","year":"2021","unstructured":"Ciolli, G. et al. Navigated percutaneous screw fixation of the pelvis with O-arm 2: Two years\u2019 experience. Med. Glas. (Zenica) 18, 309\u2013315. https:\/\/doi.org\/10.17392\/1326-21 (2021).","journal-title":"Med. Glas. (Zenica)"},{"key":"4351_CR18","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.injury.2015.11.023","volume":"47","author":"PH Richter","year":"2016","unstructured":"Richter, P. H., Gebhard, F., Dehner, C. & Scola, A. Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room. Injury 47, 402\u2013407. https:\/\/doi.org\/10.1016\/j.injury.2015.11.023 (2016).","journal-title":"Injury"},{"key":"4351_CR19","doi-asserted-by":"publisher","first-page":"S28","DOI":"10.1016\/j.injury.2020.07.025","volume":"51","author":"M Florio","year":"2020","unstructured":"Florio, M. et al. 3D-Navigated percutaneous screw fixation of pelvic ring injuries\u2014A pilot study. Injury 51, S28-33. https:\/\/doi.org\/10.1016\/j.injury.2020.07.025 (2020).","journal-title":"Injury"},{"key":"4351_CR20","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","volume":"21","author":"JL Marsh","year":"2007","unstructured":"Marsh, J. L. et al. Fracture and dislocation classification compendium\u20142007: Orthopaedic Trauma Association classification, database and outcomes committee. J. Orthop. Trauma 21, S1-133. https:\/\/doi.org\/10.1097\/00005131-200711101-00001 (2007).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR21","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1097\/00005131-199604000-00005","volume":"10","author":"ML Routt Jr","year":"1996","unstructured":"Routt, M. L. Jr., Simonian, P. T., Agnew, S. G. & Mann, F. A. Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study. J. Orthop. Trauma 10, 171\u2013177. https:\/\/doi.org\/10.1097\/00005131-199604000-00005 (1996).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR22","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1097\/00003086-198802000-00010","volume":"227","author":"F Denis","year":"1988","unstructured":"Denis, F., Davis, S. & Comfort, T. Sacral fractures: An important problem. Retrospective analysis of 236 cases. Clin. Orthop. Relat. Res. 227, 67\u201381 (1988).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"4351_CR23","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1097\/00003086-199608000-00022","volume":"329","author":"P Tornetta 3rd","year":"1996","unstructured":"Tornetta, P. 3rd. & Matta, J. M. Outcome of operatively treated unstable posterior pelvic ring disruptions. Clin. Orthop. Relat. Res. 329, 186\u2013193. https:\/\/doi.org\/10.1097\/00003086-199608000-00022 (1996).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"4351_CR24","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1302\/0301-620X.91B9.22093","volume":"91","author":"KA Lefaivre","year":"2009","unstructured":"Lefaivre, K. A., Starr, A. J., Barker, B. P., Overturf, S. & Reinert, C. M. Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. J. Bone Jt. Surg. Br. 91, 1201\u20131207. https:\/\/doi.org\/10.1302\/0301-620X.91B9.22093 (2009).","journal-title":"J. Bone Jt. Surg. Br."},{"key":"4351_CR25","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1097\/01.brs.0000194788.45002.1b","volume":"31","author":"HE Smith","year":"2006","unstructured":"Smith, H. E., Yuan, P. S., Sasso, R., Papadopolous, S. & Vaccaro, A. R. An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine 31, 234\u2013238. https:\/\/doi.org\/10.1097\/01.brs.0000194788.45002.1b (2006).","journal-title":"Spine"},{"key":"4351_CR26","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.ocl.2015.06.005","volume":"46","author":"JA Iorio","year":"2015","unstructured":"Iorio, J. A., Jakoi, A. M. & Rehman, S. Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop. Clin. N. Am. 46, 511\u2013521. https:\/\/doi.org\/10.1016\/j.ocl.2015.06.005 (2015).","journal-title":"Orthop. Clin. N. Am."},{"key":"4351_CR27","doi-asserted-by":"publisher","first-page":"S19","DOI":"10.1097\/BOT.0000000000000606","volume":"30","author":"J Tidwell","year":"2016","unstructured":"Tidwell, J. et al. Percutaneous sacroiliac screw technique. J. Orthop. Trauma 30, S19-20. https:\/\/doi.org\/10.1097\/BOT.0000000000000606 (2016).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR28","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s00264-018-4144-z","volume":"43","author":"F Liuzza","year":"2019","unstructured":"Liuzza, F. et al. Comparison between posterior sacral plate stabilization versus minimally invasive transiliac-transsacral lag-screw fixation in fractures of sacrum: A single-centre experience. Int. Orthop. 43, 177\u2013185. https:\/\/doi.org\/10.1007\/s00264-018-4144-z (2019).","journal-title":"Int. Orthop."},{"key":"4351_CR29","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s11548-016-1465-5","volume":"12","author":"SC Thakkar","year":"2017","unstructured":"Thakkar, S. C. et al. 2D versus 3-D fluoroscopy-based navigation in posterior pelvic fixation: Review of the literature on current technology. Int. J. Comput. Assist. Radiol. Surg. 12, 69\u201376. https:\/\/doi.org\/10.1007\/s11548-016-1465-5 (2017).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"4351_CR30","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1097\/00005131-200502000-00010","volume":"19","author":"HC Sagi","year":"2005","unstructured":"Sagi, H. C. & Lindvall, E. M. Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J. Orthop. Trauma 19, 130\u2013133. https:\/\/doi.org\/10.1097\/00005131-200502000-00010 (2005).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR31","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1097\/00007632-199208000-00006","volume":"17","author":"NJ Licht","year":"1992","unstructured":"Licht, N. J., Rowe, D. E. & Ross, L. M. Pitfalls of pedicle screw fixation in the sacrum. A cadaver model. Spine 17, 892\u2013896. https:\/\/doi.org\/10.1097\/00007632-199208000-00006 (1992).","journal-title":"Spine"},{"key":"4351_CR32","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00068-018-0990-z","volume":"46","author":"J Berger-Groch","year":"2020","unstructured":"Berger-Groch, J. et al. Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures. Eur. J. Trauma Emerg. Surg. 46, 107\u2013113. https:\/\/doi.org\/10.1007\/s00068-018-0990-z (2020).","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"4351_CR33","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13037-016-0115-8","volume":"10","author":"DJ Kaplan","year":"2016","unstructured":"Kaplan, D. J., Patel, J. N., Liporace, F. A. & Yoon, R. S. Intraoperative radiation safety in orthopaedics: A review of the ALARA (as low as reasonably achievable) principle. Patient Saf. Surg. 10, 27. https:\/\/doi.org\/10.1186\/s13037-016-0115-8 (2016).","journal-title":"Patient Saf. Surg."},{"key":"4351_CR34","doi-asserted-by":"publisher","first-page":"1727","DOI":"10.1016\/j.injury.2017.04.041","volume":"48","author":"A Matityahu","year":"2017","unstructured":"Matityahu, A. et al. The great unknown\u2014A systematic literature review about risk associated with intraoperative imaging during orthopaedic surgeries. Injury 48, 1727\u20131734. https:\/\/doi.org\/10.1016\/j.injury.2017.04.041 (2017).","journal-title":"Injury"},{"key":"4351_CR35","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1097\/BOT.0000000000001724","volume":"34","author":"ET Araiza","year":"2020","unstructured":"Araiza, E. T. et al. Comparing the efficiency, radiation exposure, and accuracy using C-arm versus O-arm with 3D navigation in placement of transiliac-transsacral and iliosacral screws: A cadaveric study evaluating an early career surgeon. J. Orthop. Trauma 34, 302\u2013306. https:\/\/doi.org\/10.1097\/BOT.0000000000001724 (2020).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR36","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.injury.2014.11.009","volume":"46","author":"O Pieske","year":"2015","unstructured":"Pieske, O. et al. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury 46, 333\u2013339. https:\/\/doi.org\/10.1016\/j.injury.2014.11.009 (2015).","journal-title":"Injury"},{"key":"4351_CR37","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1097\/BOT.0000000000000092","volume":"28","author":"A Matityahu","year":"2014","unstructured":"Matityahu, A. et al. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: A randomized multicenter study. J. Orthop. Trauma 28, 707\u2013710. https:\/\/doi.org\/10.1097\/BOT.0000000000000092 (2014).","journal-title":"J. Orthop. Trauma"},{"key":"4351_CR38","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1111\/os.12461","volume":"11","author":"T Long","year":"2019","unstructured":"Long, T. et al. Comparative study of percutaneous sacroiliac screw with or without TiRobot assistance for treating pelvic posterior ring fractures. Orthop. Surg. 11, 386\u2013396. https:\/\/doi.org\/10.1111\/os.12461 (2019).","journal-title":"Orthop. Surg."},{"key":"4351_CR39","doi-asserted-by":"publisher","first-page":"1299","DOI":"10.1097\/01.ta.0000133573.53587.2e","volume":"57","author":"NW Schep","year":"2004","unstructured":"Schep, N. W., Haverlag, R. & van Vugt, A. B. Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J. Trauma 57, 1299\u20131302. https:\/\/doi.org\/10.1097\/01.ta.0000133573.53587.2e (2004).","journal-title":"J. Trauma"},{"key":"4351_CR40","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1111\/j.1365-2044.2004.03707.x","volume":"60","author":"C Byhahn","year":"2005","unstructured":"Byhahn, C., Lischke, V., Meininger, D., Halbig, S. & Westphal, K. Peri-operative complications during percutaneous tracheostomy in obese patients. Anaesthesia 60, 12\u201315. https:\/\/doi.org\/10.1111\/j.1365-2044.2004.03707.x (2005).","journal-title":"Anaesthesia"},{"key":"4351_CR41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.wneu.2016.12.089","volume":"100","author":"Y Yao","year":"2017","unstructured":"Yao, Y. et al. Risk factors for recurrent herniation after percutaneous endoscopic lumbar discectomy. World Neurosurg. 100, 1\u20136. https:\/\/doi.org\/10.1016\/j.wneu.2016.12.089 (2017).","journal-title":"World Neurosurg."},{"key":"4351_CR42","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1159\/000455162","volume":"98","author":"X Zhou","year":"2017","unstructured":"Zhou, X. et al. Effect of obesity on outcomes of percutaneous nephrolithotomy in renal stone management: A systematic review and meta-analysis. Urol. Int. 98, 382\u2013390. https:\/\/doi.org\/10.1159\/000455162 (2017).","journal-title":"Urol. Int."},{"key":"4351_CR43","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1002\/jor.24199","volume":"37","author":"H Wendt","year":"2019","unstructured":"Wendt, H. et al. Recommendations for iliosacral screw placement in dysmorphic sacrum based on modified in-out-in corridors. J. Orthop. Res. 37, 689\u2013696. https:\/\/doi.org\/10.1002\/jor.24199 (2019).","journal-title":"J. Orthop. Res."},{"key":"4351_CR44","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1016\/j.injury.2018.05.027","volume":"49","author":"AQA Teo","year":"2018","unstructured":"Teo, A. Q. A., Yik, J. H., Jin Keat, S. N., Murphy, D. P. & O\u2019Neill, G. K. Accuracy of sacroiliac screw placement with and without intraoperative navigation and clinical application of the sacral dysmorphism score. Injury 49, 1302\u20131306. https:\/\/doi.org\/10.1016\/j.injury.2018.05.027 (2018).","journal-title":"Injury"},{"key":"4351_CR45","doi-asserted-by":"publisher","first-page":"e140","DOI":"10.1097\/BSD.0000000000000749","volume":"32","author":"L Weigelt","year":"2019","unstructured":"Weigelt, L. et al. Sacral dysmorphism and its implication on the size of the sacroiliac joint surface. Clin. Spine Surg. 32, e140\u2013e144. https:\/\/doi.org\/10.1097\/BSD.0000000000000749 (2019).","journal-title":"Clin. Spine Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-04351-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-04351-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-04351-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T11:10:35Z","timestamp":1700046635000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-04351-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,10]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["4351"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-04351-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,10]]},"assertion":[{"value":"20 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"368"}}