{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,17]],"date-time":"2026-05-17T06:22:30Z","timestamp":1778998950581,"version":"3.51.4"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,2,16]],"date-time":"2021-02-16T00:00:00Z","timestamp":1613433600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,2,16]],"date-time":"2021-02-16T00:00:00Z","timestamp":1613433600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"crossref","award":["2020R1F1A1072226"],"award-info":[{"award-number":["2020R1F1A1072226"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We describe a simply modified intrascleral fixation using round flange (SMURF) technique and report the clinical outcomes of the surgery. Forty-one eyes of 41 consecutive patients, with intraocular lens (IOL) dislocation, crystalline lens subluxation, and zonular weakness, who underwent surgery using the SMURF technique were included. The modified technique included the use of a conventional 27-gauge needle, a non-bent needle, oblique sclerotomy, direct threading of the leading haptic, and simple placement of the following haptic. IOLs were successfully placed and showed good centring. There were no cases of wound leakage or hypotony during the early postoperative period. Postoperative complications included vitreous haemorrhage in one eye (2.4%), intraocular pressure elevation in one eye (2.4%), and iris capture in six eyes (14.6%). There were no cases of postoperative retinal detachment, cystoid macular oedema, endophthalmitis, or IOL dislocation during the follow-up period. We proposed a few modifications in the intrascleral flanged technique for IOL fixation. The modified technique is a simple, easy, and minimally invasive procedure for successful IOL intrascleral fixation.<\/jats:p>","DOI":"10.1038\/s41598-021-81924-y","type":"journal-article","created":{"date-parts":[[2021,2,17]],"date-time":"2021-02-17T18:37:58Z","timestamp":1613587078000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The simply modified intrascleral fixation using round flange (SMURF) technique for intrascleral intraocular lens fixation"],"prefix":"10.1038","volume":"11","author":[{"given":"Soa","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jee Taek","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,2,16]]},"reference":[{"key":"81924_CR1","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/S0161-6420(02)02000-6","volume":"110","author":"MD Wagoner","year":"2003","unstructured":"Wagoner, M. D., Cox, T. A., Ariyasu, R. G., Jacobs, D. S. & Karp, C. L. Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology. Ophthalmology 110, 840\u2013859 (2003).","journal-title":"Ophthalmology"},{"key":"81924_CR2","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1016\/S0140-6736(96)11043-6","volume":"349","author":"A Hennig","year":"1997","unstructured":"Hennig, A. et al. Randomised controlled trial of anterior-chamber intraocular lenses. Lancet (London, England) 349, 1129\u20131133 (1997).","journal-title":"Lancet (London, England)"},{"key":"81924_CR3","doi-asserted-by":"publisher","first-page":"1913","DOI":"10.1016\/S0161-6420(94)31083-9","volume":"101","author":"GU Auffarth","year":"1994","unstructured":"Auffarth, G. U., Wesendahl, T. A., Brown, S. J. & Apple, D. J. Are there acceptable anterior chamber intraocular lenses for clinical use in the 1990s? An analysis of 4104 explanted anterior chamber intraocular lenses. Ophthalmology 101, 1913\u20131922 (1994).","journal-title":"Ophthalmology"},{"key":"81924_CR4","doi-asserted-by":"publisher","first-page":"208","DOI":"10.5301\/ejo.5000527","volume":"25","author":"A Anbari","year":"2015","unstructured":"Anbari, A. & Lake, D. B. Posteriorly enclavated iris claw intraocular lens for aphakia: long-term corneal endothelial safety study. Eur. J. Ophthalmol. 25, 208\u2013213. https:\/\/doi.org\/10.5301\/ejo.5000527 (2015).","journal-title":"Eur. J. Ophthalmol."},{"key":"81924_CR5","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.ajo.2008.07.038","volume":"147","author":"KG Yen","year":"2009","unstructured":"Yen, K. G., Reddy, A. K., Weikert, M. P., Song, Y. & Hamill, M. B. Iris-fixated posterior chamber intraocular lenses in children. Am. J. Ophthalmol. 147, 121\u2013126. https:\/\/doi.org\/10.1016\/j.ajo.2008.07.038 (2009).","journal-title":"Am. J. Ophthalmol."},{"key":"81924_CR6","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1097\/01.iae.0000250005.38037.da","volume":"26","author":"L Kodjikian","year":"2006","unstructured":"Kodjikian, L. et al. Combined pars plana phacofragmentation, vitrectomy, and Artisan lens implantation for traumatic subluxated cataracts. Retina (Philadelphia, Pa.) 26, 909\u2013916. https:\/\/doi.org\/10.1097\/01.iae.0000250005.38037.da (2006).","journal-title":"Retina (Philadelphia, Pa.)"},{"key":"81924_CR7","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1177\/112067219700700411","volume":"7","author":"W Omulecki","year":"1997","unstructured":"Omulecki, W., Nawrocki, J., Sempinska-Szewczyk, J. & Synder, A. Transscleral suture fixation and anterior chamber intraocular lenses implanted after removal of posteriorly dislocated crystalline lenses. Eur. J. Ophthalmol. 7, 370\u2013374 (1997).","journal-title":"Eur. J. Ophthalmol."},{"key":"81924_CR8","first-page":"515","volume":"18","author":"P Lanzetta","year":"1998","unstructured":"Lanzetta, P., Menchini, U., Virgili, G., Crovato, S. & Rapizzi, E. Scleral fixated intraocular lenses: an angiographic study. Retina (Philadelphia, Pa.) 18, 515\u2013520 (1998).","journal-title":"Retina (Philadelphia, Pa.)"},{"key":"81924_CR9","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/S0886-3350(96)80248-3","volume":"22","author":"M Helal","year":"1996","unstructured":"Helal, M., el Sayyad, F., Elsherif, Z., El-Maghraby, A. & Dabees, M. Transscleral fixation of posterior chamber intraocular lenses in the absence of capsular support. J. Cataract Refract. Surg. 22, 347\u2013351 (1996).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR10","first-page":"294","volume":"105","author":"EG Buckley","year":"2007","unstructured":"Buckley, E. G. Hanging by a thread: The long-term efficacy and safety of transscleral sutured intraocular lenses in children (an American Ophthalmological Society thesis). Trans. Am. Ophthalmol. Soc. 105, 294\u2013311 (2007).","journal-title":"Trans. Am. Ophthalmol. Soc."},{"key":"81924_CR11","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1016\/j.jcrs.2007.07.013","volume":"33","author":"SG Gabor","year":"2007","unstructured":"Gabor, S. G. & Pavlidis, M. M. Sutureless intrascleral posterior chamber intraocular lens fixation. J. Cataract Refract. Surg. 33, 1851\u20131854. https:\/\/doi.org\/10.1016\/j.jcrs.2007.07.013 (2007).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR12","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1016\/j.jcrs.2008.04.040","volume":"34","author":"A Agarwal","year":"2008","unstructured":"Agarwal, A. et al. Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules. J. Cataract Refract. Surg. 34, 1433\u20131438. https:\/\/doi.org\/10.1016\/j.jcrs.2008.04.040 (2008).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR13","doi-asserted-by":"publisher","first-page":"2051","DOI":"10.1016\/j.jcrs.2009.06.044","volume":"35","author":"I Rodriguez-Agirretxe","year":"2009","unstructured":"Rodriguez-Agirretxe, I., Acera-Osa, A. & Ubeda-Erviti, M. Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction. J. Cataract Refract. Surg. 35, 2051\u20132053. https:\/\/doi.org\/10.1016\/j.jcrs.2009.06.044 (2009).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR14","doi-asserted-by":"publisher","first-page":"1526","DOI":"10.1016\/j.jcrs.2018.08.020","volume":"44","author":"ES Hwang","year":"2018","unstructured":"Hwang, E. S., Warren, C. C. & Koenig, S. B. Flanged intrascleral intraocular lens fixation with a single needle. J. Cataract Refract. Surg. 44, 1526\u20131527. https:\/\/doi.org\/10.1016\/j.jcrs.2018.08.020 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR15","doi-asserted-by":"publisher","unstructured":"Ganne, P., Baskaran, P. & Krishnappa, N. C. Re: Yamane et al.: Flanged intrascleral intraocular lens fixation with double-needle technique (Ophthalmology. 2017;124:1136\u20131142). Ophthalmology 124, e90\u2013e91. https:\/\/doi.org\/10.1016\/j.ophtha.2017.07.007 (2017).","DOI":"10.1016\/j.ophtha.2017.07.007"},{"key":"81924_CR16","doi-asserted-by":"publisher","DOI":"10.1097\/iae.0000000000001889","author":"AC Bonnell","year":"2019","unstructured":"Bonnell, A. C., Mantopoulos, D., Wheatley, H. M. & Prenner, J. L. Surgical technique for sutureless intrascleral fixation of a 3-piece intraocular lens using a 30-gauge needle. Retina (Philadelphia Pa) https:\/\/doi.org\/10.1097\/iae.0000000000001889 (2019).","journal-title":"Retina (Philadelphia Pa)"},{"key":"81924_CR17","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jcrs.2014.08.030","volume":"41","author":"M Akimoto","year":"2015","unstructured":"Akimoto, M., Taguchi, H., Takayama, K., Nakagawa, S. & Hiroi, K. Intrascleral fixation technique using catheter needles and 30-gauge ultrathin needles: lock-and-lead technique. J. Cataract Refract. Surg. 41, 257\u2013261. https:\/\/doi.org\/10.1016\/j.jcrs.2014.08.030 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR18","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.1016\/j.jcrs.2019.06.019","volume":"45","author":"E Janse van Rensburg","year":"2019","unstructured":"Janse van Rensburg, E., Ryu, C. L., Vila, N. & Chen, J. C. Sutureless intrascleral fixation of intraocular lens through self-sealing sclerotomy wounds using haptic externalization and reinternalization technique. J. Cataract. Refract. Surg. 45, 1367\u20131371. https:\/\/doi.org\/10.1016\/j.jcrs.2019.06.019 (2019).","journal-title":"J. Cataract. Refract. Surg."},{"key":"81924_CR19","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","volume":"124","author":"S Yamane","year":"2017","unstructured":"Yamane, S., Sato, S., Maruyama-Inoue, M. & Kadonosono, K. Flanged intrascleral intraocular lens fixation with double-needle technique. Ophthalmology 124, 1136\u20131142. https:\/\/doi.org\/10.1016\/j.ophtha.2017.03.036 (2017).","journal-title":"Ophthalmology"},{"key":"81924_CR20","doi-asserted-by":"publisher","first-page":"e129","DOI":"10.3928\/23258160-20181002-15","volume":"49","author":"A Kelkar","year":"2018","unstructured":"Kelkar, A. et al. Comparison of two modified sutureless techniques of scleral fixation of intraocular lens. Ophthal. Surg. Lasers Imaging Retina 49, e129\u2013e134. https:\/\/doi.org\/10.3928\/23258160-20181002-15 (2018).","journal-title":"Ophthal. Surg. Lasers Imaging Retina"},{"key":"81924_CR21","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","volume":"121","author":"S Yamane","year":"2014","unstructured":"Yamane, S., Inoue, M., Arakawa, A. & Kadonosono, K. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology 121, 61\u201366. https:\/\/doi.org\/10.1016\/j.ophtha.2013.08.043 (2014).","journal-title":"Ophthalmology"},{"issue":"Suppl 1","key":"81924_CR22","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.1097\/iae.0000000000001889","volume":"39","author":"AC Bonnell","year":"2019","unstructured":"Bonnell, A. C., Mantopoulos, D., Wheatley, H. M. & Prenner, J. L. Surgical technique for sutureless intrascleral fixation of a 3-piece intraocular lens using a 30-gauge needle. Retina (Philadelphia, Pa) 39(Suppl 1), S13\u2013S15. https:\/\/doi.org\/10.1097\/iae.0000000000001889 (2019).","journal-title":"Retina (Philadelphia, Pa)"},{"key":"81924_CR23","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.jcrs.2018.01.027","volume":"44","author":"DB Kim","year":"2018","unstructured":"Kim, D. B. Trailing-haptic-first modification of double-needle intrascleral haptic fixation technique. J. Cataract Refract. Surg. 44, 424\u2013428. https:\/\/doi.org\/10.1016\/j.jcrs.2018.01.027 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR24","doi-asserted-by":"publisher","unstructured":"Ohtani, S. et al. One-year prospective intrapatient comparison of aspherical and spherical intraocular lenses in patients with bilateral cataract. Am. J. Ophthalmol. 147, 984\u2013989, 989.e981. https:\/\/doi.org\/10.1016\/j.ajo.2008.12.037 (2009).","DOI":"10.1016\/j.ajo.2008.12.037"},{"key":"81924_CR25","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.ophtha.2008.11.022","volume":"116","author":"S Ohtani","year":"2009","unstructured":"Ohtani, S., Miyata, K., Samejima, T., Honbou, M. & Oshika, T. Intraindividual comparison of aspherical and spherical intraocular lenses of same material and platform. Ophthalmology 116, 896\u2013901. https:\/\/doi.org\/10.1016\/j.ophtha.2008.11.022 (2009).","journal-title":"Ophthalmology"},{"key":"81924_CR26","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jcrs.2009.01.023","volume":"35","author":"M Baumeister","year":"2009","unstructured":"Baumeister, M., Buhren, J. & Kohnen, T. Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations. J. Cataract Refract. Surg. 35, 1006\u20131012. https:\/\/doi.org\/10.1016\/j.jcrs.2009.01.023 (2009).","journal-title":"J. Cataract Refract. Surg."},{"key":"81924_CR27","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1001\/archopht.123.9.1226","volume":"123","author":"L Wang","year":"2005","unstructured":"Wang, L. & Koch, D. D. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch. Ophthalmol. 123, 1226\u20131230. https:\/\/doi.org\/10.1001\/archopht.123.9.1226 (2005).","journal-title":"Arch. Ophthalmol."},{"key":"81924_CR28","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12886-017-0478-3","volume":"17","author":"D Kunita","year":"2017","unstructured":"Kunita, D. et al. Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations. BMC Ophthalmol. 17, 82. https:\/\/doi.org\/10.1186\/s12886-017-0478-3 (2017).","journal-title":"BMC Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-81924-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-81924-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-81924-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T03:45:18Z","timestamp":1670039118000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-81924-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,16]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["81924"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-81924-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,16]]},"assertion":[{"value":"6 September 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3904"}}