{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T00:22:40Z","timestamp":1791505360919,"version":"4.3.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,10]],"date-time":"2021-03-10T00:00:00Z","timestamp":1615334400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,3,10]],"date-time":"2021-03-10T00:00:00Z","timestamp":1615334400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>It is essential to know the normal range of the interocular symmetry of the cornea (ISC) for keratoconus diagnosis and corneal substitutes design. In the present study we investigated the interocular symmetry of corneal biometrics in 6,644 Chinese myopic patients from multiple ophthalmic centers. Corneal biometrics of both eyes were exported from the Pentacam instrument. Interocular symmetry of the corneal biometrics was analyzed by Spearman\u2019s correlation test, intraclass correlation coefficient (ICC) analysis and Bland\u2013Altman plot. Significantly strong interocular correlations were found in anterior and posterior corneal curvatures, corneal diameter, corneal thickness, corneal volume, corneal eccentricity, and corneal asphericity (<jats:italic>r<\/jats:italic>\u2009=\u20090.87\u20130.98, all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). Moderate interocular correlations were observed in whole corneal astigmatism (<jats:italic>r<\/jats:italic>\u2009=\u20090.78) and posterior corneal astigmatism (<jats:italic>r<\/jats:italic>\u2009=\u20090.73). ICC between the right and left eyes was 0.94\u20130.98 for anterior and posterior corneal curvatures, corneal diameter, corneal thickness and corneal volume, 0.80\u20130.88 for corneal eccentricity and asphericity, and 0.73\u20130.79 for corneal astigmatism (all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). Bland\u2013Altman plot showed that the 95% limit of agreement between both eyes was narrow and symmetric in most of the corneal biometrics, suggesting strong interocular agreements in these corneal biometrics. In conclusion, significant interocular symmetry of corneal biometrics is observed in Chinese myopia patients. Extra attention should be paid to patients with interocular corneal asymmetry.<\/jats:p>","DOI":"10.1038\/s41598-021-84937-9","type":"journal-article","created":{"date-parts":[[2021,3,10]],"date-time":"2021-03-10T11:03:12Z","timestamp":1615374192000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["A multicenter study of interocular symmetry of corneal biometrics in Chinese myopic patients"],"prefix":"10.1038","volume":"11","author":[{"given":"Guihua","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6424-7905","authenticated-orcid":false,"given":"Yijun","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shanqing","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunxiang","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuejun","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingsong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Na","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohua","family":"Lei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,10]]},"reference":[{"key":"84937_CR1","doi-asserted-by":"publisher","first-page":"4275","DOI":"10.1167\/iovs.15-16710","volume":"56","author":"GM Durr","year":"2015","unstructured":"Durr, G. M., Auvinet, E., Ong, J., Meunier, J. & Brunette, I. Corneal shape, volume, and interocular symmetry: Parameters to optimize the design of biosynthetic corneal substitutes. Investig Ophthalmol. Vis. Sci. 56, 4275\u20134282. https:\/\/doi.org\/10.1167\/iovs.15-16710 (2015).","journal-title":"Investig Ophthalmol. Vis. Sci."},{"issue":"2","key":"84937_CR2","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.jcrs.2015.09.020","volume":"42","author":"I Kov\u00e1cs","year":"2016","unstructured":"Kov\u00e1cs, I. et al. Accuracy of machine learning classifiers using bilateral data from a Scheimpflug camera for identifying eyes with preclinical signs of keratoconus. J. Cataract Refract. Surg. 42(2), 275\u2013283. https:\/\/doi.org\/10.1016\/j.jcrs.2015.09.020 (2016).","journal-title":"J. Cataract Refract. Surg."},{"issue":"6","key":"84937_CR3","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1097\/ICO.0b013e31827b14ae","volume":"32","author":"MA Henriquez","year":"2013","unstructured":"Henriquez, M. A., Izquierdo, L. Jr. & Mannis, M. J. Intereye asymmetry detected by Scheimpflug imaging in subjects with normal corneas and keratoconus. Cornea 32(6), 779\u2013782. https:\/\/doi.org\/10.1097\/ICO.0b013e31827b14ae (2013).","journal-title":"Cornea"},{"issue":"4","key":"84937_CR4","doi-asserted-by":"publisher","first-page":"171","DOI":"10.4103\/meajo.MEAJO_311_16","volume":"24","author":"N Bussi\u00e8res","year":"2017","unstructured":"Bussi\u00e8res, N., Ababneh, O. H., Abu Ameerh, M. A. & Al Bdour, M. D. Keratoconus asymmetry between both eyes based on corneal tomography. Middle East Afr. J. Ophthalmol. 24(4), 171\u2013176. https:\/\/doi.org\/10.4103\/meajo.MEAJO_311_16 (2017).","journal-title":"Middle East Afr. J. Ophthalmol."},{"issue":"6","key":"84937_CR5","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1136\/bjo.2003.034520","volume":"88","author":"JJ Nichols","year":"2004","unstructured":"Nichols, J. J., Steger-May, K., Edrington, T. B., Zadnik, K. & CLEK study group. The relation between disease asymmetry and severity in keratoconus. Br. J. Ophthalmol. 88(6), 788\u2013791. https:\/\/doi.org\/10.1136\/bjo.2003.034520 (2004).","journal-title":"Br. J. Ophthalmol."},{"key":"84937_CR6","doi-asserted-by":"publisher","first-page":"2019","DOI":"10.2147\/OPTH.S50119","volume":"7","author":"J Vazirani","year":"2013","unstructured":"Vazirani, J. & Basu, S. Keratoconus: Current perspectives. Clin. Ophthalmol. 7, 2019\u20132030. https:\/\/doi.org\/10.2147\/OPTH.S50119 (2013).","journal-title":"Clin. Ophthalmol."},{"issue":"11","key":"84937_CR7","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1016\/j.ophtha.2012.06.005","volume":"119","author":"MC Arbelaez","year":"2012","unstructured":"Arbelaez, M. C., Versaci, F., Vestri, G., Barboni, P. & Savini, G. Use of a support vector machine for keratoconus and subclinical keratoconus detection by topographic and tomographic data. Ophthalmology 119(11), 2231\u20132238. https:\/\/doi.org\/10.1016\/j.ophtha.2012.06.005 (2012).","journal-title":"Ophthalmology"},{"issue":"2","key":"84937_CR8","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/s0886-3350(99)00355-7","volume":"26","author":"GU Auffarth","year":"2000","unstructured":"Auffarth, G. U., Wang, L. & V\u00f6lcker, H. E. Keratoconus evaluation using the Orbscan Topography System. J. Cataract Refract. Surg. 26(2), 222\u2013228. https:\/\/doi.org\/10.1016\/s0886-3350(99)00355-7 (2000).","journal-title":"J. Cataract Refract. Surg."},{"issue":"1","key":"84937_CR9","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1167\/tvst.8.1.22","volume":"8","author":"X Zhu","year":"2019","unstructured":"Zhu, X., He, W., Du, Y., Zhang, K. & Lu, Y. Interocular Symmetry of Fixation, Optic Disc, and Corneal Astigmatism in Bilateral High Myopia: The Shanghai High Myopia Study. Transl Vis Sci Technol. 8(1), 22. https:\/\/doi.org\/10.1167\/tvst.8.1.22 (2019).","journal-title":"Transl Vis Sci Technol."},{"issue":"5","key":"84937_CR10","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1097\/01.opx.0000162666.83092.e4","volume":"82","author":"EH Myrowitz","year":"2005","unstructured":"Myrowitz, E. H., Kouzis, A. C. & O\u2019Brien, T. P. High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation. Optom Vis Sci. 82(5), 428\u2013431. https:\/\/doi.org\/10.1097\/01.opx.0000162666.83092.e4 (2005).","journal-title":"Optom Vis Sci."},{"key":"84937_CR11","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/s0039-6257(97)00119-7","volume":"42","author":"YS Rabinowitz","year":"1998","unstructured":"Rabinowitz, Y. S. Keratoconus. Surv. Ophthalmol. 42, 297\u2013319. https:\/\/doi.org\/10.1016\/s0039-6257(97)00119-7 (1998).","journal-title":"Surv. Ophthalmol."},{"key":"84937_CR12","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1136\/bjo.2003.033670","volume":"88","author":"DM Burns","year":"2004","unstructured":"Burns, D. M., Johnston, F. M., Frazer, D. G., Patterson, C. & Jackson, A. J. Keratoconus: An analysis of corneal asymmetry. Br. J. Ophthalmol. 88, 1252\u20131255. https:\/\/doi.org\/10.1136\/bjo.2003.033670 (2004).","journal-title":"Br. J. Ophthalmol."},{"key":"84937_CR13","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1097\/ICO.0b013e31827b14ae","volume":"32","author":"MA Henriquez","year":"2013","unstructured":"Henriquez, M. A., Izquierdo, L. Jr. & Mannis, M. J. Intereye asymmetry detected by scheimpflug imaging in subjects with normal corneas and keratoconus. Cornea 32, 779\u2013782. https:\/\/doi.org\/10.1097\/ICO.0b013e31827b14ae (2013).","journal-title":"Cornea"},{"key":"84937_CR14","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1097\/00003226-200210000-00008","volume":"21","author":"K Zadnik","year":"2002","unstructured":"Zadnik, K. et al. Between-eye asymmetry in keratoconus. Cornea 21, 671\u2013679. https:\/\/doi.org\/10.1097\/00003226-200210000-00008 (2002).","journal-title":"Cornea"},{"key":"84937_CR15","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.ajo.2013.08.014","volume":"157","author":"HB Gi","year":"2014","unstructured":"Gi, H. B. et al. Corneal topographic and tomographic analysis of fellow eyes in unilateral keratoconus patients using pentacam. Am. J. Ophthalmol. 157, 103\u2013109. https:\/\/doi.org\/10.1016\/j.ajo.2013.08.014 (2014).","journal-title":"Am. J. Ophthalmol."},{"key":"84937_CR16","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1097\/OPX.0b013e31817c930b","volume":"85","author":"V Dobson","year":"2008","unstructured":"Dobson, V., Harvey, E. M., Miller, J. M. & Clifford-Donaldson, C. E. Anisometropia prevalence in a highly astigmatic school-aged population. Optom. Vis. Sci. 85, 512\u2013519. https:\/\/doi.org\/10.1097\/OPX.0b013e31817c930b (2008).","journal-title":"Optom. Vis. Sci."},{"key":"84937_CR17","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1136\/bjo.2005.083154","volume":"90","author":"SC Huynh","year":"2006","unstructured":"Huynh, S. C. et al. Prevalence and associations of anisometropia and aniso-astigmatism in a population based sample of 6-year-old children. Br. J. Ophthalmol. 90, 597\u2013601. https:\/\/doi.org\/10.1136\/bjo.2005.083154 (2006).","journal-title":"Br. J. Ophthalmol."},{"key":"84937_CR18","first-page":"412","volume":"104","author":"YF Shih","year":"2005","unstructured":"Shih, Y. F. et al. Prevalence of anisometropia in Taiwanese schoolchildren. J. Formos. Med. Assoc. 104, 412\u2013417 (2005).","journal-title":"J. Formos. Med. Assoc."},{"key":"84937_CR19","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1167\/iovs.12-11066","volume":"54","author":"L O\u2019Donoghue","year":"2013","unstructured":"O\u2019Donoghue, L. et al. Profile of anisometropia and aniso-astigmatism in children: Prevalence and association with age, ocular biometric measures, and refractive status. Invest. Ophthalmol. Vis. Sci. 54, 602\u2013608. https:\/\/doi.org\/10.1167\/iovs.12-11066 (2013).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"issue":"1","key":"84937_CR20","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.ajo.2014.03.018","volume":"158","author":"PR Ruise\u00f1or V\u00e1zquez","year":"2014","unstructured":"Ruise\u00f1or V\u00e1zquez, P. R. et al. Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical keratoconus cases. Am. J. Ophthalmol. 158(1), 32\u201340. https:\/\/doi.org\/10.1016\/j.ajo.2014.03.018 (2014).","journal-title":"Am. J. Ophthalmol."},{"issue":"6","key":"84937_CR21","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.jcrs.2010.12.049","volume":"37","author":"\u00d6\u00d6 U\u00e7akhan","year":"2011","unstructured":"U\u00e7akhan, \u00d6. \u00d6., Cetinkor, V., \u00d6zkan, M. & Kanpolat, A. Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes. J. Cataract Refract. Surg. 37(6), 1116\u20131124. https:\/\/doi.org\/10.1016\/j.jcrs.2010.12.049 (2011).","journal-title":"J. Cataract Refract. Surg."},{"issue":"1","key":"84937_CR22","doi-asserted-by":"publisher","first-page":"16151","DOI":"10.1038\/s41598-020-73195-w","volume":"10","author":"Y Hu","year":"2020","unstructured":"Hu, Y. et al. A multicenter study of the distribution pattern of posterior corneal astigmatism in Chinese myopic patients having corneal refractive surgery. Sci. Rep. 10(1), 16151. https:\/\/doi.org\/10.1038\/s41598-020-73195-w (2020).","journal-title":"Sci. Rep."},{"issue":"10","key":"84937_CR23","doi-asserted-by":"publisher","first-page":"696","DOI":"10.3928\/1081597X-20170718-04","volume":"33","author":"X Shao","year":"2017","unstructured":"Shao, X. et al. Age-related changes in corneal astigmatism. J. Refract. Surg. 33(10), 696\u2013703. https:\/\/doi.org\/10.3928\/1081597X-20170718-04 (2017).","journal-title":"J. Refract. Surg."},{"issue":"1","key":"84937_CR24","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.jcrs.2015.07.037","volume":"42","author":"T Zheng","year":"2016","unstructured":"Zheng, T., Chen, Z. & Lu, Y. Influence factors of estimation errors for total corneal astigmatism using keratometric astigmatism in patients before cataract surgery. J. Cataract Refract. Surg. 42(1), 84\u201394. https:\/\/doi.org\/10.1016\/j.jcrs.2015.07.037 (2016).","journal-title":"J. Cataract Refract. Surg."},{"issue":"2","key":"84937_CR25","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15(2), 155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012 (2016).","journal-title":"J. Chiropr. Med."},{"issue":"2","key":"84937_CR26","doi-asserted-by":"publisher","first-page":"141","DOI":"10.11613\/BM.2015.015","volume":"25","author":"D Giavarina","year":"2015","unstructured":"Giavarina, D. Understanding Bland Altman analysis. Biochem. Med. 25(2), 141\u2013151. https:\/\/doi.org\/10.11613\/BM.2015.015 (2015).","journal-title":"Biochem. Med."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84937-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84937-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84937-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T04:53:52Z","timestamp":1670043232000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84937-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,10]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["84937"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-84937-9","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,10]]},"assertion":[{"value":"18 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5536"}}