{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T13:18:39Z","timestamp":1786972719691,"version":"build-2736575974"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,15]],"date-time":"2021-03-15T00:00:00Z","timestamp":1615766400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,3,15]],"date-time":"2021-03-15T00:00:00Z","timestamp":1615766400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Continuous intraoperative neural monitoring (C-IONM) during thyroid surgery is a useful tool for preventing recurrent laryngeal nerve (RLN) injury. The present study aims to analyze the tensile strength tolerance of C-IONM electrodes on the vagal nerve (VN). A C-IONM wire was enclosed in a hand-held tensile testing system. The probe displacement on the VN was continuously monitored by positioning a second probe far-up\/proximally in a piglet model, and an automatic periodic stimulation (APS) accessory was used. The 3-mm and 2-mm APS accessory has a mean tensile strength of 20.6\u2009\u00b1\u200910\u00a0N (range, 14.6\u201324.4\u00a0N) and 11.25\u2009\u00b1\u20098\u00a0N (range, 8.4\u201315.6\u00a0N), respectively (<jats:italic>P<\/jats:italic>\u2009=\u20090.002). There was no difference between bilateral VNs. The mean amplitude before and during electrode displacement was 1.835\u2009\u00b1\u2009102\u00a0\u03bcV and 1.795\u2009\u00b1\u2009169\u00a0\u03bcV, respectively (<jats:italic>P<\/jats:italic>\u2009=\u20090.45). The mean percentage of amplitude decrease on the electromyography (EMG) was 6.9\u2009\u00b1\u20092.5%, and the mean percentage of latency increase was 1.9\u2009\u00b1\u20091.5%. No significant amplitude reduction or loss of signal (LOS) was observed after\u2009&gt;\u200950 probe dislocations. C-IONM probe dislocation does not cause any LOS or significant EMG alterations on the VN.<\/jats:p>","DOI":"10.1038\/s41598-021-84988-y","type":"journal-article","created":{"date-parts":[[2021,3,15]],"date-time":"2021-03-15T11:03:41Z","timestamp":1615806221000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Tensile strength analysis of automatic periodic stimulation for continuous intraoperative neural monitoring in a piglet model"],"prefix":"10.1038","volume":"11","author":[{"given":"Tie","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianlorenzo","family":"Dionigi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yishen","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daqi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonella","family":"Pino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henning","family":"Dralle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Che-Wei","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Le","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1324-3808","authenticated-orcid":false,"given":"Hui","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,15]]},"reference":[{"issue":"11","key":"84988_CR1","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1002\/bjs.9889","volume":"102","author":"R Schneider","year":"2015","unstructured":"Schneider, R. et al. Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous or intermittent nerve monitoring. Br. J. Surg. 102(11), 1380\u20131387. https:\/\/doi.org\/10.1002\/bjs.9889 (2015).","journal-title":"Br. J. Surg."},{"issue":"10","key":"84988_CR2","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1007\/s00104-011-2080-1","volume":"82","author":"W Lamad\u00e9","year":"2011","unstructured":"Lamad\u00e9, W. et al. Signal stability as key requirement for continuous intraoperative neuromonitoring. Chirurg 82(10), 913\u2013920 (2011).","journal-title":"Chirurg"},{"issue":"Suppl 1","key":"84988_CR3","doi-asserted-by":"publisher","first-page":"E1568","DOI":"10.1002\/hed.24280","volume":"38","author":"A Mangano","year":"2016","unstructured":"Mangano, A. et al. Continuous intraoperative neuromonitoring in thyroid surgery: Safety analysis of 400 consecutive electrode probe placements with standardized procedures. Head Neck 38(Suppl 1), E1568\u2013E1574. https:\/\/doi.org\/10.1002\/hed.24280 (2016).","journal-title":"Head Neck"},{"issue":"2","key":"84988_CR4","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1007\/s00268-017-4277-z","volume":"42","author":"A Marin Arteaga","year":"2018","unstructured":"Marin Arteaga, A. et al. Modification of the surgical strategy for the dissection of the recurrent laryngeal nerve using continuous intraoperative nerve monitoring. World J Surg. 42(2), 444\u2013450. https:\/\/doi.org\/10.1007\/s00268-017-4277-z (2018).","journal-title":"World J Surg."},{"issue":"4","key":"84988_CR5","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/s13304-017-0455-7","volume":"69","author":"KV Ch\u00e1vez","year":"2017","unstructured":"Ch\u00e1vez, K. V. et al. Continuous intraoperative neural monitoring in thyroid surgery: a Mexican experience. Updates Surg. 69(4), 505\u2013508. https:\/\/doi.org\/10.1007\/s13304-017-0455-7 (2017).","journal-title":"Updates Surg."},{"issue":"4","key":"84988_CR6","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1007\/s00423-016-1433-0","volume":"401","author":"R Schneider","year":"2016","unstructured":"Schneider, R. et al. Continuous intraoperative monitoring of vagus and recurrent laryngeal nerve function in patients with advanced atrioventricular block. Langenbecks Arch. Surg. 401(4), 551\u2013556. https:\/\/doi.org\/10.1007\/s00423-016-1433-0 (2016).","journal-title":"Langenbecks Arch. Surg."},{"issue":"S1","key":"84988_CR7","doi-asserted-by":"publisher","first-page":"E2419","DOI":"10.1002\/hed.24358","volume":"38","author":"M Almquist","year":"2016","unstructured":"Almquist, M., Thier, M. & Salem, F. Cardiac arrest with vagal stimulation during intraoperative nerve monitoring. Head Neck 38(S1), E2419\u2013E2420. https:\/\/doi.org\/10.1002\/hed.24358 (2016).","journal-title":"Head Neck"},{"issue":"2","key":"84988_CR8","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1055\/s-0032-1328563","volume":"141","author":"J Jonas","year":"2016","unstructured":"Jonas, J. Signal changes of continuous intraoperative neuromonitoring inthyroid resections with postoperative vocal cord palsy. Zentralbl Chir. 141(2), 170\u2013174. https:\/\/doi.org\/10.1055\/s-0032-1328563 (2016).","journal-title":"Zentralbl Chir."},{"issue":"3","key":"84988_CR9","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1007\/s00268-015-3368-y","volume":"40","author":"K Brauckhoff","year":"2016","unstructured":"Brauckhoff, K. et al. Impact of EMG changes in continuous vagal nerve monitoring in high-risk endocrine neck surgery. World J Surg. 40(3), 672\u2013680. https:\/\/doi.org\/10.1007\/s00268-015-3368-y (2016).","journal-title":"World J Surg."},{"key":"84988_CR10","first-page":"79","volume":"27","author":"F Angeletti","year":"2015","unstructured":"Angeletti, F., Musholt, P. B. & Musholt, T. J. Continuous intraoperative neuromonitoringin thyroid surgery. Surg. Technol. Int. 27, 79\u201385 (2015).","journal-title":"Surg. Technol. Int."},{"issue":"10","key":"84988_CR11","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1007\/s00268-015-3139-9","volume":"39","author":"DJ Terris","year":"2015","unstructured":"Terris, D. J., Chaung, K. & Duke, W. S. Continuous vagal nerve monitoring is dangerous and should not routinely be done during thyroid surgery. World J Surg. 39(10), 2471\u20132476. https:\/\/doi.org\/10.1007\/s00268-015-3139-9 (2015).","journal-title":"World J Surg."},{"issue":"6","key":"84988_CR12","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1002\/lary.24550","volume":"124","author":"E Phelan","year":"2014","unstructured":"Phelan, E. et al. Continuous vagal IONM prevents recurrent laryngeal nerveparalysis by revealing initial EMG changes of impending neuropraxic injury: aprospective, multicenter study. Laryngoscope 124(6), 1498\u20131505. https:\/\/doi.org\/10.1002\/lary.24550 (2014).","journal-title":"Laryngoscope"},{"key":"84988_CR13","first-page":"133","volume":"24","author":"J Jonas","year":"2014","unstructured":"Jonas, J. & Boskovic, A. Intraoperative neuromonitoring (IONM) for recurrent laryngeal nerve protection: comparison of intermittent and continuous nerve stimulation. Surg Technol Int. 24, 133\u2013138 (2014).","journal-title":"Surg Technol Int."},{"issue":"11","key":"84988_CR14","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.1002\/hed.23187","volume":"35","author":"R Schneider","year":"2013","unstructured":"Schneider, R. et al. Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck. 35(11), 1591\u20131598. https:\/\/doi.org\/10.1002\/hed.23187 (2013).","journal-title":"Head Neck."},{"issue":"5","key":"84988_CR15","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1007\/s00423-013-1068-3","volume":"398","author":"S Van Slycke","year":"2013","unstructured":"Van Slycke, S., Gillardin, J. P., Brusselaers, N. & Vermeersch, H. Initial experience with S-shaped electrode for continuous vagal nerve stimulation in thyroid surgery. Langenbecks Arch Surg. 398(5), 717\u2013722. https:\/\/doi.org\/10.1007\/s00423-013-1068-3 (2013).","journal-title":"Langenbecks Arch Surg."},{"issue":"2","key":"84988_CR16","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1007\/s00268-012-1853-0","volume":"37","author":"R Schneider","year":"2013","unstructured":"Schneider, R. et al. Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring. World J Surg. 37(2), 364\u2013368. https:\/\/doi.org\/10.1007\/s00268-012-1853-0 (2013).","journal-title":"World J Surg."},{"issue":"9","key":"84988_CR17","doi-asserted-by":"publisher","first-page":"1979","DOI":"10.1002\/lary.23411","volume":"122","author":"C Friedrich","year":"2012","unstructured":"Friedrich, C. et al. Safety analysis of vagal nerve stimulation for continuous nerve monitoring during thyroid surgery. Laryngoscope 122(9), 1979\u20131987. https:\/\/doi.org\/10.1002\/lary.23411 (2012).","journal-title":"Laryngoscope"},{"issue":"3","key":"84988_CR18","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1001\/jamasurg.2015.3249","volume":"151","author":"I Suh","year":"2016","unstructured":"Suh, I., Yingling, C., Randolph, G. W. & Duh, Q. Y. A novel method of neuromonitoring in thyroidectomy and parathyroidectomy using transcutaneous intraoperative vagal stimulation. JAMA Surg. 151(3), 290\u2013292. https:\/\/doi.org\/10.1001\/jamasurg.2015.3249 (2016).","journal-title":"JAMA Surg."},{"issue":"4","key":"84988_CR19","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1002\/hed.23934","volume":"38","author":"HY Lee","year":"2016","unstructured":"Lee, H. Y. et al. Traction injury of the recurrent laryngeal nerve: results of continuous intraoperative neuromonitoring in a swine model. Head Neck 38(4), 582\u2013588. https:\/\/doi.org\/10.1002\/hed.23934 (2016).","journal-title":"Head Neck"},{"key":"84988_CR20","doi-asserted-by":"crossref","unstructured":"Randolph, G. W., Dralle, H., International Intraoperative Monitoring Study Group, Abdullah, H., Barczynski, M., Bellantone, R., Brauckhoff, M., Carnaille, B., Cherenko, S., Chiang, F. Y., Dionigi, G., Finck, C., Hartl, D., Kamani, D., Lorenz, K., Miccoli, P., Mihai, R., Miyauchi, A., Orloff, L., Perrier, N., Poveda, M. D., Romanchishen, A., Serpell, J., Sitges-Serra, A., Sloan, T., Van Slycke, S., Snyder, S., Takami, H., Volpi, E., & Woodson, G. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(1), S1\u2013S16 (2011).","DOI":"10.1002\/lary.21119"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84988-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84988-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84988-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T05:19:07Z","timestamp":1670044747000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-84988-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,15]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["84988"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-84988-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,15]]},"assertion":[{"value":"11 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5898"}}