{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T04:04:56Z","timestamp":1793160296653,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T00:00:00Z","timestamp":1617840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T00:00:00Z","timestamp":1617840000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Ministry of Education, Science and Technology,South Korea","award":["NRF-2019R1C1C1007917"],"award-info":[{"award-number":["NRF-2019R1C1C1007917"]}]},{"name":"Ministry of Education, Science and Technology,South Korea","award":["NRF-2020R1A2C2014139"],"award-info":[{"award-number":["NRF-2020R1A2C2014139"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This retrospective comparative study was to evaluate tear osmolarity measured by I-Pen osmolarity system (I-MED Pharma Inc, Dollard-des-Ormeaux, Quebec, Canada) in healthy subjects without dry eye disease (DED) and patients with DED, and its association with other ocular surface parameters. This study comprised 65 eyes of 65 patients. The ocular surface parameters including tear osmolarity with I-Pen osmometer of the patients who visited the refractive surgery center of Samsung Medical Center between January 1, 2020 and May 31, 2020 were retrospectively collected. The subjects were divided as asymptomatic normal group and symptomatic dry eye group. The distribution of tear osmolarity and its association with other ocular surface parameters were evaluated. Total thirty-two patients (32 eyes) were included in the control group, and 33 patients (33 eyes) were included in the DED group. Tear osmolarity was significantly higher in the DED group. Tear osmolarity was negatively correlated with tear break-up time, and the Schirmer test, and was positively correlated with Ocular Surface Disease Index symptom score. The cut-off value of 318\u00a0mOsm\/L showed a sensitivity of 90.9% and specificity of 90.6% for diagnosing DED. The I-Pen osmometer can be considered suitable for use in the clinical setting, with good performance in DED diagnosis.<\/jats:p>","DOI":"10.1038\/s41598-021-87336-2","type":"journal-article","created":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T10:13:19Z","timestamp":1617876799000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Evaluation of tear osmolarity measured by I-Pen osmolarity system in patients with dry eye"],"prefix":"10.1038","volume":"11","author":[{"given":"Jongyeop","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youngjoo","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyule","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eunhae","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jisang","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae-Young","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Hui","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,8]]},"reference":[{"key":"87336_CR1","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1111\/j.1475-1313.2012.00915.x","volume":"32","author":"G Julio","year":"2012","unstructured":"Julio, G., Lluch, S., Pujol, P. & Merindano, M. D. Effects of tear hyperosmolarity on conjunctival cells in mild to moderate dry eye. Ophthalmic Physiol. Opt. 32, 317\u2013323. https:\/\/doi.org\/10.1111\/j.1475-1313.2012.00915.x (2012).","journal-title":"Ophthalmic Physiol. Opt."},{"key":"87336_CR2","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1016\/j.ajo.2010.10.032","volume":"151","author":"MA Lemp","year":"2011","unstructured":"Lemp, M. A. et al. Tear osmolarity in the diagnosis and management of dry eye disease. Am. J. Ophthalmol. 151, 792\u2013798. https:\/\/doi.org\/10.1016\/j.ajo.2010.10.032 (2011).","journal-title":"Am. J. Ophthalmol."},{"key":"87336_CR3","doi-asserted-by":"publisher","unstructured":"The definition and classification of dry eye disease: report of the Definition and Classification Subcommittee of the International Dry Eye WorkShop (2007). Ocul. Surf. 5, 75-92. https:\/\/doi.org\/10.1016\/s1542-0124(12)70081-2 (2007).","DOI":"10.1016\/s1542-0124(12)70081-2"},{"key":"87336_CR4","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.jtos.2017.05.008","volume":"15","author":"JP Craig","year":"2017","unstructured":"Craig, J. P. et al. TFOS DEWS II definition and classification report. Ocul. Surf. 15, 276\u2013283. https:\/\/doi.org\/10.1016\/j.jtos.2017.05.008 (2017).","journal-title":"Ocul. Surf."},{"key":"87336_CR5","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jtos.2013.07.003","volume":"11","author":"C Baudouin","year":"2013","unstructured":"Baudouin, C. et al. Role of hyperosmolarity in the pathogenesis and management of dry eye disease: proceedings of the OCEAN group meeting. Ocul. Surf. 11, 246\u2013258. https:\/\/doi.org\/10.1016\/j.jtos.2013.07.003 (2013).","journal-title":"Ocul. Surf."},{"key":"87336_CR6","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.2147\/OPTH.S95242","volume":"9","author":"R Potvin","year":"2015","unstructured":"Potvin, R., Makari, S. & Rapuano, C. J. Tear film osmolarity and dry eye disease: a review of the literature. Clin. Ophthalmol. 9, 2039\u20132047. https:\/\/doi.org\/10.2147\/OPTH.S95242 (2015).","journal-title":"Clin. Ophthalmol."},{"key":"87336_CR7","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1097\/ICO.0b013e3182532047","volume":"31","author":"E Szalai","year":"2012","unstructured":"Szalai, E., Berta, A., Szekanecz, Z., Szucs, G. & Modis, L. Jr. Evaluation of tear osmolarity in non-Sjogren and Sjogren syndrome dry eye patients with the TearLab system. Cornea 31, 867\u2013871. https:\/\/doi.org\/10.1097\/ICO.0b013e3182532047 (2012).","journal-title":"Cornea"},{"key":"87336_CR8","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1001\/jamaophthalmol.2015.0429","volume":"133","author":"VY Bunya","year":"2015","unstructured":"Bunya, V. Y. et al. Variability of tear osmolarity in patients with dry eye. JAMA Ophthalmol. 133, 662\u2013667. https:\/\/doi.org\/10.1001\/jamaophthalmol.2015.0429 (2015).","journal-title":"JAMA Ophthalmol."},{"key":"87336_CR9","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1097\/ICO.0b013e31827e2a5e","volume":"32","author":"VY Bunya","year":"2013","unstructured":"Bunya, V. Y. et al. Tear osmolarity in Sjogren syndrome. Cornea 32, 922\u2013927. https:\/\/doi.org\/10.1097\/ICO.0b013e31827e2a5e (2013).","journal-title":"Cornea"},{"key":"87336_CR10","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1097\/ICO.0b013e3181cd9a1d","volume":"29","author":"A Tomlinson","year":"2010","unstructured":"Tomlinson, A., McCann, L. C. & Pearce, E. I. Comparison of human tear film osmolarity measured by electrical impedance and freezing point depression techniques. Cornea 29, 1036\u20131041. https:\/\/doi.org\/10.1097\/ICO.0b013e3181cd9a1d (2010).","journal-title":"Cornea"},{"key":"87336_CR11","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1097\/ICO.0000000000001653","volume":"37","author":"CC Chan","year":"2018","unstructured":"Chan, C. C., Borovik, A., Hofmann, I., Gulliver, E. & Rocha, G. Validity and reliability of a novel handheld osmolarity system for measurement of a national institute of standards traceable solution. Cornea 37, 1169\u20131174. https:\/\/doi.org\/10.1097\/ICO.0000000000001653 (2018).","journal-title":"Cornea"},{"key":"87336_CR12","unstructured":"I-Pen Osmolarity System User Manual (I-Med Pharma Inc., 2016)."},{"key":"87336_CR13","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1055\/a-1155-6468","volume":"237","author":"S Konig","year":"2020","unstructured":"Konig, S., Priglinger, S., Schaumberger, M. & Messmer, E. M. Tear film osmolarity in normal individuals: comparison of two osmometers. Klin. Monbl. Augenheilkd. 237, 649\u2013654. https:\/\/doi.org\/10.1055\/a-1155-6468 (2020).","journal-title":"Klin. Monbl. Augenheilkd."},{"key":"87336_CR14","doi-asserted-by":"publisher","first-page":"945","DOI":"10.2147\/OPTH.S135068","volume":"11","author":"J Nolfi","year":"2017","unstructured":"Nolfi, J. & Caffery, B. Randomized comparison of in vivo performance of two point-of-care tear film osmometers. Clin. Ophthalmol. 11, 945\u2013950. https:\/\/doi.org\/10.2147\/OPTH.S135068 (2017).","journal-title":"Clin. Ophthalmol."},{"key":"87336_CR15","doi-asserted-by":"publisher","first-page":"243","DOI":"10.2147\/OPTH.S127035","volume":"11","author":"G Rocha","year":"2017","unstructured":"Rocha, G., Gulliver, E., Borovik, A. & Chan, C. C. Randomized, masked, in vitro comparison of three commercially available tear film osmometers. Clin. Ophthalmol. 11, 243\u2013248. https:\/\/doi.org\/10.2147\/OPTH.S127035 (2017).","journal-title":"Clin. Ophthalmol."},{"key":"87336_CR16","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1007\/978-1-4615-0717-8_157","volume":"506","author":"MB Abelson","year":"2002","unstructured":"Abelson, M. B., Ousler, G. W. 3rd., Nally, L. A., Welch, D. & Krenzer, K. Alternative reference values for tear film break up time in normal and dry eye populations. Adv. Exp. Med. Biol. 506, 1121\u20131125. https:\/\/doi.org\/10.1007\/978-1-4615-0717-8_157 (2002).","journal-title":"Adv. Exp. Med. Biol."},{"key":"87336_CR17","doi-asserted-by":"publisher","first-page":"63","DOI":"10.20471\/acc.2019.58.01.09","volume":"58","author":"S Vidas Pauk","year":"2019","unstructured":"Vidas Pauk, S. et al. Noninvasive tear film break-up time assessment using handheld lipid layer examination instrument. Acta Clin. Croat. 58, 63\u201371. https:\/\/doi.org\/10.20471\/acc.2019.58.01.09 (2019).","journal-title":"Acta Clin. Croat."},{"key":"87336_CR18","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1001\/archopht.1973.01000040105007","volume":"89","author":"MA Lemp","year":"1973","unstructured":"Lemp, M. A. & Hamill, J. R. Jr. Factors affecting tear film breakup in normal eyes. Arch. Ophthalmol. 89, 103\u2013105. https:\/\/doi.org\/10.1001\/archopht.1973.01000040105007 (1973).","journal-title":"Arch. Ophthalmol."},{"key":"87336_CR19","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1080\/02713683.2017.1393092","volume":"43","author":"M Markoulli","year":"2018","unstructured":"Markoulli, M., Duong, T. B., Lin, M. & Papas, E. Imaging the tear film: a comparison between the subjective keeler tearscope-plus and the objective Oculus(R) keratograph 5M and LipiView(R) interferometer. Curr. Eye Res. 43, 155\u2013162. https:\/\/doi.org\/10.1080\/02713683.2017.1393092 (2018).","journal-title":"Curr. Eye Res."},{"key":"87336_CR20","doi-asserted-by":"publisher","first-page":"8013621","DOI":"10.1155\/2016\/8013621","volume":"2016","author":"L Tian","year":"2016","unstructured":"Tian, L., Qu, J. H., Zhang, X. Y. & Sun, X. G. Repeatability and reproducibility of noninvasive keratograph 5M measurements in patients with dry eye disease. J. Ophthalmol. 2016, 8013621. https:\/\/doi.org\/10.1155\/2016\/8013621 (2016).","journal-title":"J. Ophthalmol."},{"key":"87336_CR21","unstructured":"TearLab Osmolarity Test Cards. Instructions for Use (TearLab Corporation, 2015)."},{"key":"87336_CR22","unstructured":"MacIsaac, J. Impressions of the i-Pen osmolarity system. Optician Clinical Equipment (2017)."},{"key":"87336_CR23","doi-asserted-by":"publisher","first-page":"25","DOI":"10.3341\/kjo.2017.31.1.25","volume":"31","author":"M Kim","year":"2017","unstructured":"Kim, M., Kim, H. S. & Na, K. S. Correlation between tear osmolarity and other ocular surface parameters in primary Sjogren\u2019s syndrome. Korean J. Ophthalmol. 31, 25\u201331. https:\/\/doi.org\/10.3341\/kjo.2017.31.1.25 (2017).","journal-title":"Korean J. Ophthalmol."},{"key":"87336_CR24","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1001\/archopht.118.5.615","volume":"118","author":"RM Schiffman","year":"2000","unstructured":"Schiffman, R. M., Christianson, M. D., Jacobsen, G., Hirsch, J. D. & Reis, B. L. Reliability and validity of the Ocular Surface Disease Index. Arch. Ophthalmol. 118, 615\u2013621. https:\/\/doi.org\/10.1001\/archopht.118.5.615 (2000).","journal-title":"Arch. Ophthalmol."},{"key":"87336_CR25","doi-asserted-by":"publisher","first-page":"4557","DOI":"10.1167\/iovs.09-4596","volume":"51","author":"M Suzuki","year":"2010","unstructured":"Suzuki, M. et al. Tear osmolarity as a biomarker for dry eye disease severity. Invest. Ophthalmol. Vis. Sci. 51, 4557\u20134561. https:\/\/doi.org\/10.1167\/iovs.09-4596 (2010).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"87336_CR26","doi-asserted-by":"publisher","first-page":"683","DOI":"10.3109\/02713683.2011.571357","volume":"36","author":"CA Utine","year":"2011","unstructured":"Utine, C. A., Bicakcigil, M., Yavuz, S. & Ciftci, F. Tear osmolarity measurements in dry eye related to primary Sjogren\u2019s syndrome. Curr. Eye Res. 36, 683\u2013690. https:\/\/doi.org\/10.3109\/02713683.2011.571357 (2011).","journal-title":"Curr. Eye Res."},{"key":"87336_CR27","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1080\/08820538.2020.1730916","volume":"35","author":"K Ozulken","year":"2020","unstructured":"Ozulken, K., Aksoy Aydemir, G., Tekin, K. & Mumcuoglu, T. Correlation of non-invasive tear break-up time with tear osmolarity and other invasive tear function tests. Semin. Ophthalmol. 35, 78\u201385. https:\/\/doi.org\/10.1080\/08820538.2020.1730916 (2020).","journal-title":"Semin. Ophthalmol."},{"key":"87336_CR28","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics10100789","author":"J Shimazaki","year":"2020","unstructured":"Shimazaki, J., Sakata, M., Den, S., Iwasaki, M. & Toda, I. Tear film osmolarity measurement in japanese dry eye patients using a handheld osmolarity system. Diagnostics (Basel) https:\/\/doi.org\/10.3390\/diagnostics10100789 (2020).","journal-title":"Diagnostics (Basel)"},{"key":"87336_CR29","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.jtos.2016.09.003","volume":"15","author":"K Tsubota","year":"2017","unstructured":"Tsubota, K. et al. New perspectives on dry eye definition and diagnosis: a consensus report by the Asia Dry Eye Society. Ocul. Surf. 15, 65\u201376. https:\/\/doi.org\/10.1016\/j.jtos.2016.09.003 (2017).","journal-title":"Ocul. Surf."},{"key":"87336_CR30","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/s1542-0124(12)70157-x","volume":"3","author":"A Tomlinson","year":"2005","unstructured":"Tomlinson, A. & Khanal, S. Assessment of tear film dynamics: quantification approach. Ocul. Surf. 3, 81\u201395. https:\/\/doi.org\/10.1016\/s1542-0124(12)70157-x (2005).","journal-title":"Ocul. Surf."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-87336-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-87336-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-87336-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T06:27:04Z","timestamp":1670048824000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-87336-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,8]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["87336"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-87336-2","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,8]]},"assertion":[{"value":"15 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"7726"}}