{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T09:20:15Z","timestamp":1790328015690,"version":"4.1.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100015400","name":"Fonds Erasme pour la Recherche M\u00e9dicale","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100015400","id-type":"DOI","asserted-by":"crossref"}]},{"name":"CHU de Charleroi"},{"name":"Fonds de la Chirurgie Cardiaque"},{"name":"Fonds de la Recherche M\u00e9dicale en Hainaut"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Aneurysm wall motion has been reported to be associated with rupture. However, its quantification with medical imaging is challenging and should be based on experimental ground-truth to avoid misinterpretation of results. In this work a time-resolved CT angiography (4D-CTA) acquisition protocol is proposed to detect the pulsation of intracranial aneurysms with a low radiation dose. To acquire ground-truth data, the accuracy of volume pulsation detection and quantification in a silicone phantom was assessed by applying pressure sinusoidal waves of increasing amplitudes. These experiments were carried out using a test bench that could reproduce pulsatile waveforms similar to those inside the internal carotid arteries of human subjects. 4D-CTA acquisition parameters (mAs, kVp) were then selected to achieve reliable pulsation detection and quantification with the lowest radiation dose achievable. The resulting acquisition protocol was then used to image an anterior communicating artery aneurysm in a human subject. Data reveals that in a simplified in vitro setting 4D-CTA allows for an effective and reproducible method to detect and quantify aneurysm volume pulsation with an inferior limit as low as 3\u00a0mm<jats:sup>3<\/jats:sup> and a background noise of 0.5\u20131\u00a0mm<jats:sup>3<\/jats:sup>. Aneurysm pulsation can be detected in vivo with a radiation dose approximating 1\u00a0mSv.<\/jats:p>","DOI":"10.1038\/s41598-021-88420-3","type":"journal-article","created":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T10:03:25Z","timestamp":1620036205000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Development of experimental ground truth and quantification of intracranial aneurysm pulsation in a patient"],"prefix":"10.1038","volume":"11","author":[{"given":"Axel E.","family":"Vanrossomme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kamil J.","family":"Chodzy\u0144ski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omer F.","family":"Eker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karim Zouaoui","family":"Boudjeltia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,5,3]]},"reference":[{"key":"88420_CR1","doi-asserted-by":"crossref","unstructured":"Unruptured intracranial aneurysms-risk of rupture and risks of surgical intervention. International study of unruptured intracranial aneurysms investigators. N. Engl. J. Med. 339, 1725\u20131733 (1998).","DOI":"10.1056\/NEJM199812103392401"},{"key":"88420_CR2","doi-asserted-by":"crossref","unstructured":"Barker, F. G., 2nd, Amin-Hanjani, S., Butler, W. E., Ogilvy, C. S. & Carter, B. S. In-hospital mortality and morbidity after surgical treatment of unruptured intracranial aneurysms in the United States, 1996\u20132000: the effect of hospital and surgeon volume. Neurosurgery 52, 995\u20131007; discussion 1007\u20131009 (2003).","DOI":"10.1227\/01.NEU.0000057743.56678.5F"},{"key":"88420_CR3","first-page":"1409","volume":"24","author":"BL Hoh","year":"2003","unstructured":"Hoh, B. L., Rabinov, J. D., Pryor, J. C., Carter, B. S. & Barker, F. G. In-hospital morbidity and mortality after endovascular treatment of unruptured intracranial Aneurysms in the United States, 1996\u20132000: effect of hospital and physician volume. Am. J. Neuroradiol. 24, 1409\u20131420 (2003).","journal-title":"Am. J. Neuroradiol."},{"key":"88420_CR4","doi-asserted-by":"publisher","first-page":"2474","DOI":"10.1056\/NEJMoa1113260","volume":"366","author":"A Morita","year":"2012","unstructured":"Morita, A. et al. The natural course of unruptured cerebral aneurysms in a Japanese cohort. N. Engl. J. Med. 366, 2474\u20132482 (2012).","journal-title":"N. Engl. J. Med."},{"key":"88420_CR5","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/S1474-4422(13)70263-1","volume":"13","author":"JP Greving","year":"2014","unstructured":"Greving, J. P. et al. Development of the PHASES score for prediction of risk of rupture of intracranial aneurysms: a pooled analysis of six prospective cohort studies. Lancet Neurol. 13, 59\u201366 (2014).","journal-title":"Lancet Neurol."},{"key":"88420_CR6","doi-asserted-by":"publisher","first-page":"879","DOI":"10.3171\/jns.1993.78.6.0879","volume":"78","author":"FB Meyer","year":"1993","unstructured":"Meyer, F. B., Huston, J. 3rd. & Riederer, S. S. Pulsatile increases in aneurysm size determined by cine phase-contrast MR angiography. J. Neurosurg. 78, 879\u2013883 (1993).","journal-title":"J. Neurosurg."},{"key":"88420_CR7","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1055\/s-2004-818492","volume":"47","author":"Y Kato","year":"2004","unstructured":"Kato, Y. et al. Prediction of Impending rupture in aneurysms using 4D-CTA: histopathological verification of a real-time minimally invasive tool in unruptured aneurysms. Min Minim. Invasive Neurosurg. 47, 131\u2013135 (2004).","journal-title":"Min Minim. Invasive Neurosurg."},{"key":"88420_CR8","doi-asserted-by":"crossref","unstructured":"Ishida, F., Ogawa, H., Simizu, T., Kojima, T. & Taki, W. Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography. Neurosurgery 57, 460\u2013471; discussion 460\u2013471 (2005).","DOI":"10.1227\/01.NEU.0000170540.17300.DD"},{"key":"88420_CR9","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1088\/0967-3334\/31\/9\/004","volume":"31","author":"E Oubel","year":"2010","unstructured":"Oubel, E. et al. Wall motion estimation in intracranial aneurysms. Physiol. Meas. 31, 1119\u20131135 (2010).","journal-title":"Physiol. Meas."},{"key":"88420_CR10","doi-asserted-by":"publisher","first-page":"459","DOI":"10.3171\/jns.1996.84.3.0459","volume":"84","author":"JM Wardlaw","year":"1996","unstructured":"Wardlaw, J. M. & Cannon, J. C. Color transcranial \u2018power\u2019 Doppler ultrasound of intracranial aneurysms. J. Neurosurg. 84, 459\u2013461 (1996).","journal-title":"J. Neurosurg."},{"key":"88420_CR11","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.acra.2012.06.008","volume":"20","author":"A Firouzian","year":"2013","unstructured":"Firouzian, A. et al. Quantification of intracranial aneurysm morphodynamics from ECG-gated CT angiography. Acad. Radiol. 20, 52\u201358 (2013).","journal-title":"Acad. Radiol."},{"key":"88420_CR12","doi-asserted-by":"crossref","unstructured":"Karmonik, C., Diaz, O., Grossman, R. & Klucznik, R. In-vivo quantification of wall motion in cerebral aneurysms from 2D cine phase contrast magnetic resonance images. R\u00f6Fo Fortschritte Auf Dem Geb. R\u00f6ntgenstrahlen Nukl. 182, 140\u2013150 (2010).","DOI":"10.1055\/s-0028-1109670"},{"key":"88420_CR13","doi-asserted-by":"publisher","first-page":"1294","DOI":"10.1118\/1.3549761","volume":"38","author":"C Zhang","year":"2011","unstructured":"Zhang, C. et al. Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography. Med. Phys. 38, 1294\u20131306 (2011).","journal-title":"Med. Phys."},{"key":"88420_CR14","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1259\/bjr.71.841.9534703","volume":"71","author":"PR Hoskins","year":"1998","unstructured":"Hoskins, P. R., Prattis, J. & Wardlaw, J. A flow model of cerebral aneurysms for use with power Doppler studies. Br. J. Radiol. 71, 76\u201380 (1998).","journal-title":"Br. J. Radiol."},{"key":"88420_CR15","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4310","author":"AE Vanrossomme","year":"2015","unstructured":"Vanrossomme, A. E., Eker, O. F., Thiran, J.-P., Courbebaisse, G. P. & Zouaoui Boudjeltia, K. Intracranial aneurysms: wall motion analysis for prediction of rupture. AJNR Am. J. Neuroradiol. https:\/\/doi.org\/10.3174\/ajnr.A4310 (2015).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"88420_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-013-0236-8","author":"M Hayakawa","year":"2013","unstructured":"Hayakawa, M. et al. Detection of pulsation in unruptured cerebral aneurysms by ECG-gated 3D-CT angiography (4D-CTA) with 320-row area detector CT (ADCT) and follow-up evaluation results: assessment based on heart rate at the time of scanning. Clin. Neuroradiol. https:\/\/doi.org\/10.1007\/s00062-013-0236-8 (2013).","journal-title":"Clin. Neuroradiol."},{"key":"88420_CR17","doi-asserted-by":"publisher","first-page":"11004","DOI":"10.1038\/s41598-018-29282-0","volume":"8","author":"D Schetelig","year":"2018","unstructured":"Schetelig, D. et al. Analysis of the influence of imaging-related uncertainties on cerebral aneurysm deformation quantification using a no-deformation physical flow phantom. Sci. Rep. 8, 11004 (2018).","journal-title":"Sci. Rep."},{"key":"88420_CR18","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s12938-015-0065-x","volume":"14","author":"KJ Chodzy\u0144ski","year":"2015","unstructured":"Chodzy\u0144ski, K. J. et al. An in vitro test bench reproducing coronary blood flow signals. Biomed. Eng. Online 14, 77 (2015).","journal-title":"Biomed. Eng. Online"},{"key":"88420_CR19","unstructured":"\/02\/14 Les crit\u00e8res minimaux d\u2019acceptabilit\u00e9 pour les appareils de scanographie (scanners CT). http:\/\/www.jurion.fanc.fgov.be\/jurdb-consult\/faces\/doorlopendeTekstPdf.jsp?print=false."},{"key":"88420_CR20","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1148\/radiol.2483071964","volume":"248","author":"W Huda","year":"2008","unstructured":"Huda, W., Ogden, K. M. & Khorasani, M. R. Converting dose-length product to effective dose at CT. Radiology 248, 995\u20131003 (2008).","journal-title":"Radiology"},{"key":"88420_CR21","doi-asserted-by":"crossref","unstructured":"Schetelig, D. et al. Phantom-based ground-truth generation for cerebral vessel segmentation and pulsatile deformation analysis. 9786, 978622\u2013978622\u20136 (2016).","DOI":"10.1117\/12.2216675"},{"key":"88420_CR22","doi-asserted-by":"publisher","first-page":"2685","DOI":"10.1016\/j.jbiomech.2011.07.026","volume":"44","author":"V Costalat","year":"2011","unstructured":"Costalat, V. et al. Biomechanical wall properties of human intracranial aneurysms resected following surgical clipping (IRRAs Project). J. Biomech. 44, 2685\u20132691 (2011).","journal-title":"J. Biomech."},{"key":"88420_CR23","unstructured":"Niveaux de r\u00e9f\u00e9rence diagnostiques en radiologie - Scanners CT. AFCN - Agence F\u00e9d\u00e9rale Contr\u00f4 Nucl. (2020). https:\/\/afcn.fgov.be\/fr\/professionnels\/professions-medicales\/applications-radiologiques\/nrd\/CTscanners."},{"key":"88420_CR24","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1148\/radiol.2017161911","volume":"284","author":"KM Kanal","year":"2017","unstructured":"Kanal, K. M. et al. US diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology 284, 120\u2013133 (2017).","journal-title":"Radiology"},{"key":"88420_CR25","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1055\/s-0029-1225355","volume":"70","author":"T Krings","year":"2009","unstructured":"Krings, T. et al. Pulsatility of an intracavernous aneurysm demonstrated by dynamic 320-detector row CTA at high temporal resolution. Cent. Eur. Neurosurg. 70, 214\u2013218 (2009).","journal-title":"Cent. Eur. Neurosurg."},{"key":"88420_CR26","doi-asserted-by":"crossref","unstructured":"Hayakawa, M. et al. Detection of pulsation in ruptured and unruptured cerebral aneurysms by electrocardiographically gated 3-dimensional computed tomographic angiography with a 320-row area detector computed tomography and evaluation of its clinical usefulness. Neurosurgery 69, 843\u2013851; discussion 851 (2011).","DOI":"10.1227\/NEU.0b013e318225b2d3"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-88420-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-88420-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-88420-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T07:40:47Z","timestamp":1670053247000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-88420-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,3]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["88420"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-88420-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,3]]},"assertion":[{"value":"26 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9441"}}