{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T18:50:29Z","timestamp":1740163829636,"version":"3.37.3"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T00:00:00Z","timestamp":1620864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T00:00:00Z","timestamp":1620864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005795","name":"Chang Gung Memorial Hospital, Linkou","doi-asserted-by":"publisher","award":["CORPG3J0381"],"award-info":[{"award-number":["CORPG3J0381"]}],"id":[{"id":"10.13039\/501100005795","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In some cases of vertebroplasty for adjacent fractures, we observed a cement bridging phenomenon, in which the injected cement flowed from the newly fractured vertebra to the previously cement-augmented vertebra through the space between the abutting anterior longitudinal ligament and the vertebral column. The purpose of this retrospective study was to investigate this phenomenon. From January 2012 to December 2014, patients who sustained new-onset adjacent vertebral compression fracture and who were again treated with vertebroplasty were enrolled. We divided the patients into two groups, the bridging group and the nonbridging group, to analyze the difference between them. Results showed that the cement bridging phenomenon occurred in 18 (22.8%) of the 79 patients. Significant differences between the bridging and nonbridging groups were identified in the following 3 imaging features: severe loss of the anterior vertebral body height at the new-onset adjacent vertebra on plain film (odds ratio [OR]\u2009=\u20094.46, p\u2009=\u20090.014), fluid accumulation (OR\u2009=\u200936.27, p\u2009&lt;\u20090.001) and hypointense signaling (OR\u2009=\u200915.67, p\u2009&lt;\u20090.001) around the space anterior to the abutting vertebral bodies and the corresponding intervertebral disc on MRI. After a 2-year follow-up, both the mean value of the focal kyphotic angle and anterior body height ratio were significantly better in the cement bridging group than in the nonbridging group. The cement bridging phenomenon, which has never been reported in the literature, is not rare in clinical practice. This phenomenon was associated with better maintenance of focal kyphotic angle and anterior body height ratio during the 2-year follow-up.<\/jats:p>","DOI":"10.1038\/s41598-021-89412-z","type":"journal-article","created":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T10:03:16Z","timestamp":1620900196000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Cement bridging phenomenon in percutaneous vertebroplasty for adjacent vertebral compression fracture"],"prefix":"10.1038","volume":"11","author":[{"given":"Yun-Da","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsung-Ting","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chi-Chien","family":"Niu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Po-Liang","family":"Lai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,5,13]]},"reference":[{"key":"89412_CR1","first-page":"166","volume":"33","author":"P Galibert","year":"1987","unstructured":"Galibert, P., Deramond, H., Rosat, P. & Le Gars, D. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33, 166\u2013168 (1987).","journal-title":"Neurochirurgie"},{"key":"89412_CR2","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1097\/BRS.0000000000001298","volume":"41","author":"EZ Yang","year":"2016","unstructured":"Yang, E. Z. et al. Percutaneous vertebroplasty versus conservative treatment in aged patients with acute osteoporotic vertebral compression fractures: a prospective randomized controlled clinical study. Spine (Phila Pa 1976) 41, 653\u2013660 (2016).","journal-title":"Spine (Phila Pa 1976)"},{"key":"89412_CR3","doi-asserted-by":"publisher","first-page":"E13","DOI":"10.36076\/ppj.2017.1.E13","volume":"20","author":"H Zhang","year":"2017","unstructured":"Zhang, H., Xu, C., Zhang, T., Gao, Z. & Zhang, T. Does percutaneous vertebroplasty or balloon kyphoplasty for osteoporotic vertebral compression fractures increase the incidence of new vertebral fractures? A meta-analysis. Pain Physician 20, E13\u2013E28 (2017).","journal-title":"Pain Physician"},{"key":"89412_CR4","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/S0140-6736(10)60954-3","volume":"376","author":"CA Klazen","year":"2010","unstructured":"Klazen, C. A. et al. Vertebroplasty versus conservative treatment in acute osteoporotic vertebral compression fractures (Vertos II): an open-label randomised trial. Lancet 376, 1085\u20131092 (2010).","journal-title":"Lancet"},{"key":"89412_CR5","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.spinee.2011.07.027","volume":"11","author":"MJ Nieuwenhuijse","year":"2011","unstructured":"Nieuwenhuijse, M. J., Van Erkel, A. R. & Dijkstra, P. D. Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J. 11, 839\u2013848 (2011).","journal-title":"Spine J."},{"key":"89412_CR6","doi-asserted-by":"publisher","first-page":"821","DOI":"10.3390\/ma9100821","volume":"9","author":"P Shridhar","year":"2016","unstructured":"Shridhar, P. et al. A review of PMMA bone cement and intra-cardiac embolism. Materials (Basel) 9, 821 (2016).","journal-title":"Materials (Basel)"},{"key":"89412_CR7","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1007\/s00586-015-3786-4","volume":"24","author":"HL Ren","year":"2015","unstructured":"Ren, H. L., Jiang, J. M., Chen, J. T. & Wang, J. X. Risk factors of new symptomatic vertebral compression fractures in osteoporotic patients undergone percutaneous vertebroplasty. Eur. Spine J. 24, 750\u2013758 (2015).","journal-title":"Eur. Spine J."},{"key":"89412_CR8","doi-asserted-by":"publisher","first-page":"86","DOI":"10.13004\/kjnt.2014.10.2.86","volume":"10","author":"DH Seo","year":"2014","unstructured":"Seo, D. H. et al. Risk factors of new adjacent compression fracture after percutaneous vertebroplasty: effectiveness of bisphosphonate in osteoporotic or osteopenic elderly patients. Korean J. Neurotrauma. 10, 86\u201391 (2014).","journal-title":"Korean J. Neurotrauma."},{"key":"89412_CR9","doi-asserted-by":"publisher","first-page":"E578","DOI":"10.1097\/BSD.0000000000000043","volume":"28","author":"DG Lee","year":"2015","unstructured":"Lee, D. G., Park, C. K., Park, C. J., Lee, D. C. & Hwang, J. H. Analysis of risk factors causing new symptomatic vertebral compression fractures after percutaneous vertebroplasty for painful osteoporotic vertebral compression fractures: a 4-year follow-up. J. Spinal Disord. Tech. 28, E578-583 (2015).","journal-title":"J. Spinal Disord. Tech."},{"key":"89412_CR10","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.ijsu.2016.10.030","volume":"36","author":"S Yang","year":"2016","unstructured":"Yang, S., Liu, Y., Yang, H. & Zou, J. Risk factors and correlation of secondary adjacent vertebral compression fracture in percutaneous kyphoplasty. Int. J. Surg. 36, 138\u2013142 (2016).","journal-title":"Int. J. Surg."},{"key":"89412_CR11","doi-asserted-by":"publisher","first-page":"210","DOI":"10.31616\/asj.2018.0224","volume":"13","author":"BS Ko","year":"2019","unstructured":"Ko, B. S., Cho, K. J. & Park, J. W. Early adjacent vertebral fractures after balloon kyphoplasty for osteoporotic vertebral compression fractures. Asian Spine J. 13, 210\u2013215 (2019).","journal-title":"Asian Spine J."},{"key":"89412_CR12","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1007\/s00586-016-4784-x","volume":"26","author":"D Song","year":"2017","unstructured":"Song, D. et al. Secondary balloon kyphoplasty for new vertebral compression fracture after initial single-level balloon kyphoplasty for osteoporotic vertebral compression fracture. Eur. Spine J. 26, 1842\u20131851 (2017).","journal-title":"Eur. Spine J."},{"key":"89412_CR13","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","volume":"85","author":"JS Yeom","year":"2003","unstructured":"Yeom, J. S. et al. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J. Bone Joint Surg. Br. 85, 83\u201389 (2003).","journal-title":"J. Bone Joint Surg. Br."},{"key":"89412_CR14","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1007\/s00270-005-0138-5","volume":"29","author":"A Komemushi","year":"2006","unstructured":"Komemushi, A. et al. Percutaneous vertebroplasty for osteoporotic compression fracture: multivariate study of predictors of new vertebral body fracture. Cardiovasc. Intervent Radiol. 29, 580\u2013585 (2006).","journal-title":"Cardiovasc. Intervent Radiol."},{"key":"89412_CR15","first-page":"175","volume":"25","author":"EP Lin","year":"2004","unstructured":"Lin, E. P., Ekholm, S., Hiwatashi, A. & Westesson, P. L. Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body. AJNR Am. J. Neuroradiol. 25, 175\u2013180 (2004).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"89412_CR16","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/BSD.0b013e3181981843","volume":"23","author":"WJ Chen","year":"2010","unstructured":"Chen, W. J. et al. Impact of cement leakage into disks on the development of adjacent vertebral compression fractures. J. Spinal Disord. Tech. 23, 35\u201339 (2010).","journal-title":"J. Spinal Disord. Tech."},{"key":"89412_CR17","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00586-011-2099-5","volume":"21","author":"YJ Rho","year":"2012","unstructured":"Rho, Y. J., Choe, W. J. & Chun, Y. I. Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty. Eur. Spine J. 21, 905\u2013911 (2012).","journal-title":"Eur. Spine J."},{"key":"89412_CR18","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1007\/s00586-007-0564-y","volume":"17","author":"WC Lin","year":"2008","unstructured":"Lin, W. C. et al. Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis. Eur. Spine J. 17, 592\u2013599 (2008).","journal-title":"Eur. Spine J."},{"key":"89412_CR19","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1007\/s00256-011-1139-x","volume":"40","author":"KA Lee","year":"2011","unstructured":"Lee, K. A. et al. Analysis of adjacent fracture after percutaneous vertebroplasty: does intradiscal cement leakage really increase the risk of adjacent vertebral fracture?. Skeletal Radiol. 40, 1537\u20131542 (2011).","journal-title":"Skeletal Radiol."},{"key":"89412_CR20","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/j.wneu.2017.01.124","volume":"101","author":"U Zhan","year":"2017","unstructured":"Zhan, U., Jiang, J. Z., Liao, H. F., Tan, H. T. & Yang, K. Q. Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence. World Neurosurg. 101, 633\u2013642 (2017).","journal-title":"World Neurosurg."},{"key":"89412_CR21","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1177\/0284185117732599","volume":"59","author":"S Hassan","year":"2018","unstructured":"Hassan, S. et al. Clinical outcome and subsequent sequelae of cement extravasation after percutaneous kyphoplasty and vertebroplasty: a comparative review. Acta Radiol. 59, 861\u2013868 (2018).","journal-title":"Acta Radiol."},{"key":"89412_CR22","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1007\/s00402-010-1236-7","volume":"131","author":"LH Chen","year":"2011","unstructured":"Chen, L. H. et al. Repeated percutaneous vertebroplasty for refracture of cemented vertebrae. Arch. Orthop. Trauma. Surg. 131, 927\u2013933 (2011).","journal-title":"Arch. Orthop. Trauma. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-89412-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-89412-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-89412-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T08:14:39Z","timestamp":1670055279000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-89412-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,13]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["89412"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-89412-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2021,5,13]]},"assertion":[{"value":"12 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10184"}}