{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T14:58:48Z","timestamp":1793372328289,"version":"4.5.0"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,6,21]],"date-time":"2021-06-21T00:00:00Z","timestamp":1624233600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,21]],"date-time":"2021-06-21T00:00:00Z","timestamp":1624233600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>At present, the pedicle screw is the most commonly used internal fixation device. However, there are many kinds of common posterior pedicle screw insertion techniques performed to reconstruct the lumbar stability. Therefore, spinal surgeons often face a difficult choice. The stress distribution of internal fixation system is an important index for evaluating safety. Unfortunately, little had been known about the difference of stress distribution of screw-rod systems that established by Roy-Camille, Magerl and Krag insertion techniques. Here, combination of finite element analysis and model measurement research was adopted to evaluate the difference of stress. Following different pedicle screw insertion techniques, three lumbar posterior surgery models were established after modeling and validation of the L1\u2013S1 vertebrae finite element model. By analyzing the data, we found that stress concentration phenomenon was in all the postoperative models. Roy-Camille and Magerl insertion techniques led to the great stress on screw-rod systems. Then, fresh frozen calf spines were selected as a model for subsequent measurements. Fitted with a specially designed test pedicle screw, L5\u2013L6 vertebrae were selected to repeat and verify the results of the finite element analysis. With the aid of universal testing machine and digital torque wrench, models simulated flexion, extension, lateral bending and rotation. Finally, the strain value was captured by the strain gauge and was then calculated as the stress value. Krag and Magerl were found to be the safer choice for pedicle screw insertion. Overall, our combination method obtained the reliable result that Krag insertion technique was the safer approach for pedicle screw implantation due to its relatively dispersive stress. Therefore, without the consideration of screw size, pedicle fill, bone density, and bone structures, we recommend the Krag insertion technique as the first choice to reconstruction of lumbar stability. Additionally, the combination method of finite element analysis and strain gauge measurement can provide a feasible way to study the stress distribution of spinal internal fixation.<\/jats:p>","DOI":"10.1038\/s41598-021-90686-6","type":"journal-article","created":{"date-parts":[[2021,6,21]],"date-time":"2021-06-21T10:03:10Z","timestamp":1624269790000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Stress distribution of different lumbar posterior pedicle screw insertion techniques: a combination study of finite element analysis and biomechanical test"],"prefix":"10.1038","volume":"11","author":[{"given":"Mingzhi","family":"Song","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kebin","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4735-1193","authenticated-orcid":false,"given":"Zhonghai","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junwei","family":"Zong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiliang","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shouyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,21]]},"reference":[{"key":"90686_CR1","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1097\/00007632-199106000-00002","volume":"16","author":"M Heli\u00f6vaara","year":"1991","unstructured":"Heli\u00f6vaara, M., M\u00e4kel\u00e4, M., Knekt, P., Impivaara, O. & Aromaa, A. Determinants of sciatica and low-back pain. Spine (Phila Pa 1976). 16, 608\u2013614 (1991).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR2","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1302\/0301-620X.41B2.248","volume":"41","author":"HH Boucher","year":"1959","unstructured":"Boucher, H. H. A method of spinal fusion. J. Bone Jt. Surg. Br. 41, 248\u2013259 (1959).","journal-title":"J. Bone Jt. Surg. Br."},{"key":"90686_CR3","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/BRS.0b013e31826980a9","volume":"38","author":"JM Mac-Thiong","year":"2013","unstructured":"Mac-Thiong, J. M., Parent, S., Poitras, B., Joncas, J. & Hubert, L. Neurological outcome and management of pedicle screws misplaced totally within the spinal canal. Spine (Phila Pa 1976). 38, 229\u2013237 (2013).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR4","doi-asserted-by":"publisher","first-page":"e39","DOI":"10.1097\/BPO.0000000000000160","volume":"34","author":"I Sanpera","year":"2014","unstructured":"Sanpera, I., Piza-Vallespir, G. & Burgos-Flores, J. Upper thoracic pedicle screws loss of fixation causing spinal cord injury. J. Pediatr. Orthop. 34, e39 (2014).","journal-title":"J. Pediatr. Orthop."},{"key":"90686_CR5","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","volume":"81","author":"JE Lonstein","year":"1999","unstructured":"Lonstein, J. E. et al. Complications associated with pedicle screws. J. Bone Jt. Surg. Am. 81, 1519\u20131528 (1999).","journal-title":"J. Bone Jt. Surg. Am."},{"key":"90686_CR6","doi-asserted-by":"crossref","unstructured":"Esses, S. I., Sachs, B. L. & Dreyzin, V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976).\u00a018, 2231\u20132238 (1993).","DOI":"10.1097\/00007632-199311000-00015"},{"issue":"23","key":"90686_CR7","doi-asserted-by":"publisher","first-page":"2702","DOI":"10.1097\/00007632-199412000-00020","volume":"19","author":"N Ransom","year":"1994","unstructured":"Ransom, N., La Rocca, S. H. & Thalgott, J. The case for pedicle fixation of the lumbar spine. Spine (Phila Pa 1976). 19, 2702\u20132706 (1994).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR8","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.engfailanal.2012.05.009","volume":"25","author":"S Griza","year":"2012","unstructured":"Griza, S., Andrade, C. E. C. D., Batista, W. W., Tentardini, E. K. & Strohaecker, T. R. Case study of ti6al4v pedicle screw failures due to geometric and microstructural aspects. Eng. Fail. Anal. 25, 133\u2013143 (2012).","journal-title":"Eng. Fail. Anal."},{"key":"90686_CR9","doi-asserted-by":"publisher","first-page":"1458","DOI":"10.2106\/00004623-200010000-00013","volume":"82-A","author":"RW Gaines","year":"2000","unstructured":"Gaines, R. W. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J. Bone Jt. Surg. Am. 82-A, 1458\u20131476 (2000).","journal-title":"J. Bone Jt. Surg. Am."},{"key":"90686_CR10","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.medengphy.2004.12.007","volume":"27","author":"CS Chen","year":"2005","unstructured":"Chen, C. S. et al. Failure analysis of broken pedicle screws on spinal instrumentation. Med. Eng. Phys. 27, 487\u2013496 (2005).","journal-title":"Med. Eng. Phys."},{"key":"90686_CR11","doi-asserted-by":"publisher","first-page":"25","DOI":"10.4103\/2152-7806.92933","volume":"3","author":"S Burneikiene","year":"2012","unstructured":"Burneikiene, S. et al. Complications in patients undergoing combined transforaminal lumbar interbody fusion and posterior instrumentation with deformity correction for degenerative scoliosis and spinal stenosis. Surg. Neurol. Int. 3, 25 (2012).","journal-title":"Surg. Neurol. Int."},{"key":"90686_CR12","doi-asserted-by":"publisher","first-page":"310","DOI":"10.4055\/cios.2017.9.3.310","volume":"9","author":"AF Ozer","year":"2017","unstructured":"Ozer, A. F. et al. Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: a retrospective clinical and radiological analysis of 71 patients. Clin. Orthop. Surg. 9, 310\u2013316 (2017).","journal-title":"Clin. Orthop. Surg."},{"key":"90686_CR13","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1097\/00005131-199308000-00015","volume":"7","author":"K Willett","year":"1993","unstructured":"Willett, K., Hearn, T. C. & Cuncins, A. V. Biomechanical testing of a new design for Schanz pedicle screws. J. Orthop. Trauma. 7, 375\u2013380 (1993).","journal-title":"J. Orthop. Trauma"},{"key":"90686_CR14","first-page":"e637","volume":"8","author":"A Kashkoush","year":"2016","unstructured":"Kashkoush, A., Agarwal, N., Paschel, E., Goldschmidt, E. & Gerszten, P. C. Evaluation of a hybrid dynamic stabilization and fusion system in the lumbar spine: a 10 year experience. Cureus. 8, e637 (2016).","journal-title":"Cureus"},{"key":"90686_CR15","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1097\/00007632-199901010-00005","volume":"24","author":"TO McKinley","year":"1999","unstructured":"McKinley, T. O. et al. Characteristics of pedicle screw loading. Effect of surgical technique on intravertebral and intrapedicular bending moments. Spine (Phila Pa 1976). 24, 18\u201324 (1999).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR16","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1097\/00007632-199906010-00006","volume":"24","author":"JA Youssef","year":"1999","unstructured":"Youssef, J. A., McKinley, T. O., Yerby, S. A. & McLain, R. F. Characteristics of pedicle screw loading. Effect of surgical technique on intravertebral and intrapedicular bending moments. Spine (Phila Pa 1976). 24, 1077\u20131081 (1999).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR17","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1097\/00007632-199707010-00006","volume":"22","author":"RF McLain","year":"1997","unstructured":"McLain, R. F., McKinley, T. O., Yerby, S. A., Smith, T. S. & Sarigul-Klijn, N. The effect of bone quality on pedicle screw loading in axial instability. A synthetic model. Spine (Phila Pa 1976). 22, 1454\u20131460 (1997).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR18","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1080\/10255842.2016.1209187","volume":"20","author":"AG Newcomb","year":"2017","unstructured":"Newcomb, A. G., Baek, S., Kelly, B. P. & Crawford, N. R. Effect of screw position on load transfer in lumbar pedicle screws: a non-idealized finite element analysis. Comput. Methods Biomech. Biomed. Eng. 20, 182\u2013192 (2017).","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"90686_CR19","doi-asserted-by":"publisher","first-page":"1558","DOI":"10.1007\/s00586-014-3313-z","volume":"23","author":"S Fu","year":"2014","unstructured":"Fu, S. et al. Comparison of the risk of breakage of two kinds of sacroiliac screws in the treatment of bilateral sacral fractures. Eur. Spine J. 23, 1558\u20131567 (2014).","journal-title":"Eur. Spine J."},{"key":"90686_CR20","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-198602000-00003","volume":"203","author":"R Roy-Camille","year":"1986","unstructured":"Roy-Camille, R., Saillant, G. & Mazel, C. Internal fixation of the lumbar spine with pedicle screw plating. Clin. Orthop. Relat. Res. 203, 7\u201317 (1986).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"90686_CR21","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/00003086-198410000-00014","volume":"189","author":"FP Magerl","year":"1984","unstructured":"Magerl, F. P. Stabilization of the lower thoractic and lumbar spine with external skeletal fixation. Clin. Orthop. 189, 125\u2013130 (1984).","journal-title":"Clin. Orthop."},{"key":"90686_CR22","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1097\/00007632-198908000-00020","volume":"14","author":"MH Krag","year":"1989","unstructured":"Krag, M. H., Van Hal, M. E. & Beynnon, B. D. Placement of transpedicular vertebral screws close to anterior vertebral cortex. Description of methods. Spine (Phila Pa 1976). 14, 879\u2013883 (1989).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR23","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1080\/10255842.2010.501762","volume":"14","author":"CC Lo","year":"2011","unstructured":"Lo, C. C., Tsai, K. J., Zhong, Z. C., Chen, S. H. & Hung, C. Biomechanical differences of coflex-f and pedicle screw fixation combined with tlif or alif\u2013a finite element study. Comput. Methods Biomech. Biomed. Eng. 14, 947\u2013956 (2011).","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"90686_CR24","doi-asserted-by":"publisher","first-page":"e441","DOI":"10.3928\/01477447-20140430-54","volume":"37","author":"Z Gong","year":"2014","unstructured":"Gong, Z. et al. Finite element analysis of 3 posterior fixation techniques in the lumbar spine. Orthopedics. 37, e441-448 (2014).","journal-title":"Orthopedics"},{"key":"90686_CR25","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.jos.2017.10.009","volume":"23","author":"JK Biswas","year":"2018","unstructured":"Biswas, J. K., Rana, M., Majumder, S., Karmakar, S. K. & Roychowdhury, A. J. Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: a finite element study. Orthop. Sci. 23, 258\u2013265 (2018).","journal-title":"Orthop. Sci."},{"key":"90686_CR26","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1016\/j.jbiomech.2014.04.002","volume":"47","author":"M Dreischarf","year":"2014","unstructured":"Dreischarf, M. et al. Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together. J. Biomech. 47, 1757\u20131766 (2014).","journal-title":"J. Biomech."},{"key":"90686_CR27","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1097\/00007632-198911000-00020","volume":"14","author":"I Yamamoto","year":"1989","unstructured":"Yamamoto, I., Panjabi, M. M., Crisco, T. & Oxland, T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine (Phila Pa 1976). 14, 1256\u20131260 (1989).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR28","doi-asserted-by":"publisher","first-page":"413","DOI":"10.2106\/00004623-199403000-00012","volume":"76","author":"MM Panjabi","year":"1994","unstructured":"Panjabi, M. M., Oxland, T. R., Yamamoto, I. & Crisco, J. J. Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves. J. Bone Jt. Surg. Am. 76, 413\u2013424 (1994).","journal-title":"J. Bone Jt. Surg. Am."},{"key":"90686_CR29","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/S1350-4533(01)00076-5","volume":"23","author":"CS Chen","year":"2001","unstructured":"Chen, C. S., Cheng, C. K., Liu, C. L. & Lo, W. H. Stress analysis of the disc adjacent to interbody fusion in lumbar spine. Med. Eng. Phys. 23, 483\u2013491 (2001).","journal-title":"Med. Eng. Phys."},{"key":"90686_CR30","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1007\/s11517-010-0621-2","volume":"48","author":"HJ Kim","year":"2010","unstructured":"Kim, H. J. et al. Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis. Med. Biol. Eng. Comput. 48, 703\u2013709 (2010).","journal-title":"Med. Biol. Eng. Comput."},{"key":"90686_CR31","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/1475-925X-11-31","volume":"11","author":"Z Xiao","year":"2012","unstructured":"Xiao, Z., Wang, L., Gong, H. & Zhu, D. Biomechanical evaluation of three surgical scenarios of posterior lumbar interbody fusion by finite element analysis. Biomed. Eng. Online. 11, 31 (2012).","journal-title":"Biomed. Eng. Online"},{"key":"90686_CR32","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1016\/S0140-6736(16)31678-6","volume":"388","author":"GBD 2015 Disease and Injury Incidence and PrevalenceCollaborators","year":"2016","unstructured":"GBD 2015 Disease and Injury Incidence and PrevalenceCollaborators. Global, regional, and national incidence, prevalence, and years lived with disability for 310 diseases and injuries, 1990\u20132015: a systematic analysis for the Global Burden of Disease Study 2015. Lancet. 388, 1545\u20131602 (2016).","journal-title":"Lancet"},{"key":"90686_CR33","doi-asserted-by":"publisher","first-page":"842","DOI":"10.31616\/asj.2018.0243","volume":"13","author":"R Khatri","year":"2019","unstructured":"Khatri, R., Varghese, V., Sharma, S., Kumar, G. S. & Chhabra, H. S. Pullout strength predictor: a machine learning approach. Asian Spine J. 13, 842\u2013848 (2019).","journal-title":"Asian Spine J."},{"key":"90686_CR34","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.medengphy.2016.11.012","volume":"40","author":"V Varghese","year":"2017","unstructured":"Varghese, V., Saravana Kumar, G. & Krishnan, V. Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models. Med. Eng. Phys. 40, 28\u201338 (2017).","journal-title":"Med. Eng. Phys."},{"key":"90686_CR35","doi-asserted-by":"publisher","first-page":"414","DOI":"10.4184\/asj.2016.10.3.414","volume":"10","author":"V Krishnan","year":"2016","unstructured":"Krishnan, V., Varghese, V. & Kumar, G. S. Comparative analysis of effect of density, insertion angle and reinsertion on pull-out strength of single and two pedicle screw constructs using synthetic bone model. Asian Spine J. 10, 414\u2013421 (2016).","journal-title":"Asian Spine J."},{"key":"90686_CR36","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1055\/s-0040-1710072","volume":"55","author":"R Fleury","year":"2020","unstructured":"Fleury, R. et al. The role of pedicle screw surface on insertion torque and pullout strength. Revista brasileira de ortopedia. 55, 695\u2013701 (2020).","journal-title":"Revista brasileira de ortopedia"},{"key":"90686_CR37","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/S1529-9430(01)00020-1","volume":"1","author":"SD Cook","year":"2001","unstructured":"Cook, S. D., Barbera, J., Rubi, M., Salkeld, S. L. & Whitecloud, T. S. Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation and osteoporosis. Spine J. 1, 109\u2013114 (2001).","journal-title":"Spine J."},{"key":"90686_CR38","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.clinbiomech.2017.02.011","volume":"43","author":"YY Hsieh","year":"2017","unstructured":"Hsieh, Y. Y. et al. Removal of fixation construct could mitigate adjacent segment stress after lumbosacral fusion: a finite element analysis. Clin. Biomech. 43, 115 (2017).","journal-title":"Clin. Biomech."},{"key":"90686_CR39","first-page":"20","volume":"29","author":"Y G\u00fcven\u00e7","year":"2019","unstructured":"G\u00fcven\u00e7, Y. et al. How to reduce stress on the pedicle screws in thoracic spine? Importance of screw trajectory: a finite element analysis. Turk. Neurosurg. 29, 20\u201325 (2019).","journal-title":"Turk. Neurosurg."},{"key":"90686_CR40","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/1475-925X-13-115","volume":"13","author":"M Song","year":"2014","unstructured":"Song, M. et al. Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution. Biomed. Eng. Online. 13, 115 (2014).","journal-title":"Biomed. Eng. Online"},{"key":"90686_CR41","doi-asserted-by":"publisher","first-page":"2514","DOI":"10.1097\/00007632-200010010-00014","volume":"25","author":"D Pape","year":"2000","unstructured":"Pape, D., Adam, F., Fritsch, E., M\u00fcller, K. & Kohn, D. Primary lumbosacral stability after open posterior and endoscopic anterior fusion with interbody implants: a roentgen stereophotogrammetric analysis. Spine (Phila Pa 1976). 25, 2514\u20132518 (2000).","journal-title":"Spine (Phila Pa 1976)"},{"key":"90686_CR42","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1007\/s10237-017-0885-7","volume":"16","author":"M Begonia","year":"2017","unstructured":"Begonia, M., Dallas, M., Johnson, M. L. & Thiagarajan, G. Comparison of strain measurement in the mouse forearm using subject-specific finite element models, strain gaging, and digital image correlation. Biomech. Model Mechanobiol. 16, 1243\u20131253 (2017).","journal-title":"Biomech. Model Mechanobiol."},{"key":"90686_CR43","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jpor.2015.08.003","volume":"60","author":"G Wang","year":"2016","unstructured":"Wang, G., Zhang, S., Bian, C. & Kong, H. Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement. J. Prosthodont. Res. 60, 29\u201335 (2016).","journal-title":"J. Prosthodont. Res."},{"key":"90686_CR44","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1097\/00004770-200308000-00009","volume":"29","author":"V Lertchirakarn","year":"2003","unstructured":"Lertchirakarn, V., Palamara, J. E. & Messer, H. H. Finite element analysis and strain-gauge studies of vertical root fracture. J. Endod. 29, 529\u2013534 (2003).","journal-title":"J. Endod."},{"key":"90686_CR45","first-page":"439","volume":"24","author":"A Eser","year":"2009","unstructured":"Eser, A., Ak\u00e7a, K., Eckert, S. & Cehreli, M. C. Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants. Int. J. Oral Maxillofac. Implant. 24, 439\u2013446 (2009).","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"90686_CR46","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1016\/S0109-5641(00)00036-1","volume":"16","author":"D Palamara","year":"2000","unstructured":"Palamara, D., Palamara, J. E., Tyas, M. J. & Messer, H. H. Strain patterns in cervical enamel of teeth subjected to occlusal loading. Dent. Mater. 16, 412\u2013419 (2000).","journal-title":"Dent. Mater."},{"key":"90686_CR47","first-page":"1736763","volume":"2019","author":"J Gao","year":"2019","unstructured":"Gao, J., Liu, B., Zhang, M., Gong, H. & Gao, B. Strain distribution evaluation of rat tibia under axial compressive load by combining strain gauge measurement and finite element analysis. Appl. Bion. Biomech. 2019, 1736763 (2019).","journal-title":"Appl. Bion. Biomech."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-90686-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-90686-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-90686-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T10:07:48Z","timestamp":1670062068000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-90686-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,21]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["90686"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-90686-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,21]]},"assertion":[{"value":"23 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12968"}}