{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:50:19Z","timestamp":1792615819582,"version":"4.5.0"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T00:00:00Z","timestamp":1623196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T00:00:00Z","timestamp":1623196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cardiac dyssynchrony is the proposed mechanism for pacemaker-induced cardiomyopathy, which can be prevented by biventricular pacing. Left bundle branch pacing and His bundle pacing are novel interventions that imitate the natural conduction of the heart with, theoretically, less interventricular dyssynchrony. One of the surrogate markers of interventricular synchrony is QRS duration. Our study aimed to compare the change of QRS duration before and after implantation between types of cardiac implantable electronic devices (CIEDs): left bundle branch pacing versus His bundle pacing versus biventricular pacing and conventional right ventricular pacing. A literature search for studies that reported an interval change of QRS duration after CIED implantation was conducted utilizing the MEDLINE, EMBASE, and Cochrane databases. All relevant works from database inception through November 2020 were included in this analysis. A random-effects model, Bayesian network meta-analysis was used to analyze QRS duration changes (eg, electrical cardiac synchronization) across different CIED implantations. The mean study sample size, from 14 included studies, was 185 subjects. The search found 707 articles. After exclusions, 14 articles remained with 2,054 patients. The His bundle pacing intervention resulted in the most dramatic decline in QRS duration (mean difference,\u2009\u2212\u200953\u00a0ms; 95% CI\u2009\u2212\u200967,\u2009\u2212\u200939), followed by left bundle branch pacing (mean difference,\u2009\u2212\u200946\u00a0ms; 95% CI\u2009\u2212\u200960,\u2009\u2212\u200933), and biventricular pacing (mean difference,\u2009\u2212\u200919\u00a0ms; 95% CI\u2009\u2212\u200937,\u2009\u2212\u20091.8), when compared to conventional right ventricle apical pacing. When compared between LBBP and HBP, showed no statistically significant wider QRS duration in LBBP with mean different 6.5\u00a0ms. (95% CI \u2212\u20096.7, 21). Our network meta-analysis found that physiologic pacing has the greatest effect on QRS duration after implantation. Thus, HBP and LBBP showed no significant difference between QRS duration after implantation. Physiologic pacing interventions result in improved electrocardiography markers of cardiac synchrony, narrower QRS duration, and might lower electromechanical dyssynchrony.<\/jats:p>","DOI":"10.1038\/s41598-021-91610-8","type":"journal-article","created":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T10:16:45Z","timestamp":1623233805000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["A network meta-analysis and systematic review of change in QRS duration after left bundle branch pacing, His bundle pacing, biventricular pacing, or right ventricular pacing in patients requiring permanent pacemaker"],"prefix":"10.1038","volume":"11","author":[{"given":"Nithi","family":"Tokavanich","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Narut","family":"Prasitlumkum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wimwipa","family":"Mongkonsritragoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wisit","family":"Cheungpasitporn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charat","family":"Thongprayoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saraschandra","family":"Vallabhajosyula","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronpichai","family":"Chokesuwattanaskul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,9]]},"reference":[{"key":"91610_CR1","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s10840-019-00602-2","volume":"56","author":"R Bansal","year":"2019","unstructured":"Bansal, R. et al. Incidence and predictors of pacemaker-induced cardiomyopathy with comparison between apical and non-apical right ventricular pacing sites. J. Interv. Cardiac Electrophysiol. 56, 63\u201370. https:\/\/doi.org\/10.1007\/s10840-019-00602-2 (2019).","journal-title":"J. Interv. Cardiac Electrophysiol."},{"key":"91610_CR2","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1111\/jce.13045","volume":"27","author":"S Khurshid","year":"2016","unstructured":"Khurshid, S. et al. Longer paced QRS duration is associated with increased prevalence of right ventricular pacing-induced cardiomyopathy. J. Cardiovasc. Electrophysiol. 27, 1174\u20131179. https:\/\/doi.org\/10.1111\/jce.13045 (2016).","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"91610_CR3","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1093\/europace\/eur258","volume":"14","author":"H Dreger","year":"2012","unstructured":"Dreger, H., Maethner, K., Bondke, H., Baumann, G. & Melzer, C. Pacing-induced cardiomyopathy in patients with right ventricular stimulation for >15 years. Europace 14, 238\u2013242. https:\/\/doi.org\/10.1093\/europace\/eur258 (2012).","journal-title":"Europace"},{"key":"91610_CR4","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1111\/j.1540-8159.2006.00338.x","volume":"29","author":"AS Manolis","year":"2006","unstructured":"Manolis, A. S. The deleterious consequences of right ventricular apical pacing: time to seek alternate site pacing. Pacing Clin. Electrophysiol. 29, 298\u2013315. https:\/\/doi.org\/10.1111\/j.1540-8159.2006.00338.x (2006).","journal-title":"Pacing Clin. Electrophysiol."},{"key":"91610_CR5","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1016\/j.jacc.2006.07.027","volume":"48","author":"HF Tse","year":"2006","unstructured":"Tse, H. F. & Lau, C. P. Selection of permanent ventricular pacing site: How far should we go?. J. Am. Coll. Cardiol. 48, 1649\u20131651. https:\/\/doi.org\/10.1016\/j.jacc.2006.07.027 (2006).","journal-title":"J. Am. Coll. Cardiol."},{"key":"91610_CR6","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/0002-8703(86)90682-4","volume":"112","author":"GE Adomian","year":"1986","unstructured":"Adomian, G. E. & Beazell, J. Myofibrillar disarray produced in normal hearts by chronic electrical pacing. Am. Heart J. 112, 79\u201383. https:\/\/doi.org\/10.1016\/0002-8703(86)90682-4 (1986).","journal-title":"Am. Heart J."},{"key":"91610_CR7","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1056\/NEJMoa1210356","volume":"368","author":"AB Curtis","year":"2013","unstructured":"Curtis, A. B. et al. Biventricular pacing for atrioventricular block and systolic dysfunction. N. Engl. J. Med. 368, 1585\u20131593. https:\/\/doi.org\/10.1056\/NEJMoa1210356 (2013).","journal-title":"N. Engl. J. Med."},{"key":"91610_CR8","doi-asserted-by":"publisher","first-page":"1797","DOI":"10.1016\/j.hrthm.2019.05.009","volume":"16","author":"GA Upadhyay","year":"2019","unstructured":"Upadhyay, G. A. et al. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial. Heart Rhythm 16, 1797\u20131807. https:\/\/doi.org\/10.1016\/j.hrthm.2019.05.009 (2019).","journal-title":"Heart Rhythm"},{"key":"91610_CR9","doi-asserted-by":"publisher","first-page":"e008874","DOI":"10.1161\/CIRCEP.120.008874","volume":"13","author":"V Ravi","year":"2020","unstructured":"Ravi, V. et al. Pros and cons of left bundle branch pacing. Circ. Arrhyth. Electrophysiol. 13, e008874. https:\/\/doi.org\/10.1161\/CIRCEP.120.008874 (2020).","journal-title":"Circ. Arrhyth. Electrophysiol."},{"key":"91610_CR10","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.jclinepi.2018.01.003","volume":"100","author":"S Sideri","year":"2018","unstructured":"Sideri, S., Papageorgiou, S. N. & Eliades, T. Registration in the international prospective register of systematic reviews (PROSPERO) of systematic review protocols was associated with increased review quality. J. Clin. Epidemiol. 100, 103\u2013110. https:\/\/doi.org\/10.1016\/j.jclinepi.2018.01.003 (2018).","journal-title":"J. Clin. Epidemiol."},{"key":"91610_CR11","doi-asserted-by":"publisher","first-page":"e296","DOI":"10.1371\/journal.pmed.0040296","volume":"4","author":"E von Elm","year":"2007","unstructured":"von Elm, E. et al. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies. PLoS Med. 4, e296. https:\/\/doi.org\/10.1371\/journal.pmed.0040296 (2007).","journal-title":"PLoS Med."},{"key":"91610_CR12","doi-asserted-by":"publisher","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher, D., Liberati, A., Tetzlaff, J. & Altman, D. G. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med. 6, e1000097. https:\/\/doi.org\/10.1371\/journal.pmed.1000097 (2009).","journal-title":"PLoS Med."},{"key":"91610_CR13","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","volume":"25","author":"A Stang","year":"2010","unstructured":"Stang, A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur. J. Epidemiol. 25, 603\u2013605. https:\/\/doi.org\/10.1007\/s10654-010-9491-z (2010).","journal-title":"Eur. J. Epidemiol."},{"key":"91610_CR14","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/1471-2458-13-154","volume":"13","author":"R Herzog","year":"2013","unstructured":"Herzog, R. et al. Are healthcare workers\u2019 intentions to vaccinate related to their knowledge, beliefs and attitudes? A systematic review . BMC Public Health 13, 154. https:\/\/doi.org\/10.1186\/1471-2458-13-154 (2013).","journal-title":"BMC Public Health"},{"key":"91610_CR15","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","volume":"7","author":"R DerSimonian","year":"1986","unstructured":"DerSimonian, R. & Laird, N. Meta-analysis in clinical trials. Control. Clin. Trials 7, 177\u2013188 (1986).","journal-title":"Control. Clin. Trials"},{"key":"91610_CR16","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jclinepi.2010.03.016","volume":"64","author":"G Salanti","year":"2011","unstructured":"Salanti, G., Ades, A. E. & Ioannidis, J. P. Graphical methods and numerical summaries for presenting results from multiple-treatment meta-analysis: An overview and tutorial. J. Clin. Epidemiol. 64, 163\u2013171. https:\/\/doi.org\/10.1016\/j.jclinepi.2010.03.016 (2011).","journal-title":"J. Clin. Epidemiol."},{"key":"91610_CR17","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1177\/0272989X12458724","volume":"33","author":"S Dias","year":"2013","unstructured":"Dias, S., Sutton, A. J., Ades, A. E. & Welton, N. J. Evidence synthesis for decision making 2: A generalized linear modeling framework for pairwise and network meta-analysis of randomized controlled trials. Med. Decis. Mak. 33, 607\u2013617. https:\/\/doi.org\/10.1177\/0272989X12458724 (2013).","journal-title":"Med. Decis. Mak."},{"key":"91610_CR18","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1002\/jrsm.1044","volume":"3","author":"JP Higgins","year":"2012","unstructured":"Higgins, J. P. et al. Consistency and inconsistency in network meta-analysis: Concepts and models for multi-arm studies. Res. Synth. Methods 3, 98\u2013110. https:\/\/doi.org\/10.1002\/jrsm.1044 (2012).","journal-title":"Res. Synth. Methods"},{"key":"91610_CR19","doi-asserted-by":"publisher","first-page":"e99682","DOI":"10.1371\/journal.pone.0099682","volume":"9","author":"G Salanti","year":"2014","unstructured":"Salanti, G., Del Giovane, C., Chaimani, A., Caldwell, D. M. & Higgins, J. P. Evaluating the quality of evidence from a network meta-analysis. PLoS ONE 9, e99682. https:\/\/doi.org\/10.1371\/journal.pone.0099682 (2014).","journal-title":"PLoS ONE"},{"key":"91610_CR20","doi-asserted-by":"publisher","first-page":"2369","DOI":"10.1002\/sim.4001","volume":"29","author":"G Salanti","year":"2010","unstructured":"Salanti, G. et al. Evaluating novel agent effects in multiple-treatments meta-regression. Stat. Med. 29, 2369\u20132383. https:\/\/doi.org\/10.1002\/sim.4001 (2010).","journal-title":"Stat. Med."},{"key":"91610_CR21","doi-asserted-by":"publisher","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","volume":"71","author":"M Abdelrahman","year":"2018","unstructured":"Abdelrahman, M. et al. Clinical outcomes of His bundle pacing compared to right ventricular pacing. J. Am. Coll. Cardiol. 71, 2319. https:\/\/doi.org\/10.1016\/j.jacc.2018.02.048 (2018).","journal-title":"J. Am. Coll. Cardiol."},{"key":"91610_CR22","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1093\/europace\/eun023","volume":"10","author":"AE Albertsen","year":"2008","unstructured":"Albertsen, A. E. et al. Biventricular pacing preserves left ventricular performance in patients with high-grade atrio-ventricular block: A randomized comparison with DDD(R) pacing in 50 consecutive patients. Europace 10, 314\u2013320. https:\/\/doi.org\/10.1093\/europace\/eun023 (2008).","journal-title":"Europace"},{"key":"91610_CR23","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1111\/jce.14342","volume":"31","author":"B Cai","year":"2020","unstructured":"Cai, B. et al. Evaluation of cardiac synchrony in left bundle branch pacing: Insights from echocardiographic research. J. Cardiovasc. Electrophysiol. 31, 560\u2013569. https:\/\/doi.org\/10.1111\/jce.14342 (2020).","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"91610_CR24","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1093\/europace\/euy252","volume":"21","author":"K Chen","year":"2019","unstructured":"Chen, K. et al. Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy. Europace 21, 673\u2013680. https:\/\/doi.org\/10.1093\/europace\/euy252 (2019).","journal-title":"Europace"},{"key":"91610_CR25","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1016\/j.jacep.2020.05.008","volume":"6","author":"W Hua","year":"2020","unstructured":"Hua, W. et al. Comparison of left bundle branch and His bundle pacing in bradycardia patients. JACC Clin. Electrophysiol. 6, 1291\u20131299. https:\/\/doi.org\/10.1016\/j.jacep.2020.05.008 (2020).","journal-title":"JACC Clin. Electrophysiol."},{"key":"91610_CR26","doi-asserted-by":"publisher","first-page":"1694","DOI":"10.1093\/europace\/euz188","volume":"21","author":"X Hou","year":"2019","unstructured":"Hou, X. et al. Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. Europace 21, 1694\u20131702. https:\/\/doi.org\/10.1093\/europace\/euz188 (2019).","journal-title":"Europace"},{"key":"91610_CR27","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1016\/j.hrthm.2015.03.048","volume":"12","author":"DL Lustgarten","year":"2015","unstructured":"Lustgarten, D. L. et al. His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: A crossover design comparison. Heart Rhythm 12, 1548\u20131557. https:\/\/doi.org\/10.1016\/j.hrthm.2015.03.048 (2015).","journal-title":"Heart Rhythm"},{"key":"91610_CR28","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.1016\/j.jacc.2006.01.056","volume":"47","author":"E Occhetta","year":"2006","unstructured":"Occhetta, E. et al. Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: A crossover, blinded, randomized study versus apical right ventricular pacing. J. Am. Coll. Cardiol. 47, 1938\u20131945. https:\/\/doi.org\/10.1016\/j.jacc.2006.01.056 (2006).","journal-title":"J. Am. Coll. Cardiol."},{"key":"91610_CR29","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.hrthm.2014.10.021","volume":"12","author":"PS Sharma","year":"2015","unstructured":"Sharma, P. S. et al. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice. Heart Rhythm 12, 305\u2013312. https:\/\/doi.org\/10.1016\/j.hrthm.2014.10.021 (2015).","journal-title":"Heart Rhythm"},{"key":"91610_CR30","doi-asserted-by":"publisher","first-page":"e014253","DOI":"10.1161\/jaha.119.014253","volume":"8","author":"S Wang","year":"2019","unstructured":"Wang, S. et al. Feasibility and efficacy of His bundle pacing or left bundle pacing combined with atrioventricular node ablation in patients with persistent atrial fibrillation and implantable cardioverter-defibrillator therapy. J. Am. Heart Assoc. 8, e014253. https:\/\/doi.org\/10.1161\/jaha.119.014253 (2019).","journal-title":"J. Am. Heart Assoc."},{"key":"91610_CR31","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/S0735-1097(20)31406-6","volume":"75","author":"Y Wang","year":"2020","unstructured":"Wang, Y., Qian, Z., Hou, X. & Zou, J. A matched case-control\/cohort study of left bundle branch pacing and biventricular pacing in patients with heart failure. J. Am. Coll. Cardiol. 75, 779. https:\/\/doi.org\/10.1016\/S0735-1097(20)31406-6 (2020).","journal-title":"J. Am. Coll. Cardiol."},{"key":"91610_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2020.04.037","author":"S Wu","year":"2020","unstructured":"Wu, S. et al. Left bundle branch pacing for cardiac resynchronization therapy: Nonrandomized on-treatment comparison with His bundle pacing and biventricular pacing. Can. J. Cardiol. https:\/\/doi.org\/10.1016\/j.cjca.2020.04.037 (2020).","journal-title":"Can. J. Cardiol."},{"key":"91610_CR33","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1002\/clc.23215","volume":"42","author":"J Zhang","year":"2019","unstructured":"Zhang, J. et al. Immediate clinical outcomes of left bundle branch area pacing vs conventional right ventricular pacing. Clin. Cardiol. 42, 768\u2013773. https:\/\/doi.org\/10.1002\/clc.23215 (2019).","journal-title":"Clin. Cardiol."},{"key":"91610_CR34","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1161\/01.CIR.101.8.869","volume":"101","author":"P Deshmukh","year":"2000","unstructured":"Deshmukh, P., Casavant David, A., Romanyshyn, M. & Anderson, K. Permanent, direct His-bundle pacing. Circulation 101, 869\u2013877. https:\/\/doi.org\/10.1161\/01.CIR.101.8.869 (2000).","journal-title":"Circulation"},{"key":"91610_CR35","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1111\/j.1540-8159.2004.00548.x","volume":"27","author":"PM Deshmukh","year":"2004","unstructured":"Deshmukh, P. M. & Romanyshyn, M. Direct His-bundle pacing: Present and future. Pacing Clin. Electrophysiol. 27, 862\u2013870. https:\/\/doi.org\/10.1111\/j.1540-8159.2004.00548.x (2004).","journal-title":"Pacing Clin. Electrophysiol."},{"key":"91610_CR36","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.1093\/europace\/euy058","volume":"20","author":"F Zanon","year":"2018","unstructured":"Zanon, F. et al. Permanent His-bundle pacing: A systematic literature review and meta-analysis. Europace 20, 1819\u20131826. https:\/\/doi.org\/10.1093\/europace\/euy058 (2018).","journal-title":"Europace"},{"key":"91610_CR37","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1161\/01.cir.41.1.77","volume":"41","author":"OS Narula","year":"1970","unstructured":"Narula, O. S., Scherlag, B. J. & Samet, P. Pervenous pacing of the specialized conducting system in man. His bundle and A-V nodal stimulation. Circulation 41, 77\u201387. https:\/\/doi.org\/10.1161\/01.cir.41.1.77 (1970).","journal-title":"Circulation"},{"key":"91610_CR38","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.1016\/j.jacc.2005.01.071","volume":"46","author":"A Kashani","year":"2005","unstructured":"Kashani, A. & Barold, S. S. Significance of QRS complex duration in patients with heart failure. J. Am. Coll. Cardiol. 46, 2183\u20132192. https:\/\/doi.org\/10.1016\/j.jacc.2005.01.071 (2005).","journal-title":"J. Am. Coll. Cardiol."},{"key":"91610_CR39","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1067\/mhj.2002.122516","volume":"143","author":"S Iuliano","year":"2002","unstructured":"Iuliano, S., Fisher, S. G., Karasik, P. E., Fletcher, R. D. & Singh, S. N. QRS duration and mortality in patients with congestive heart failure. Am. Heart J. 143, 1085\u20131091. https:\/\/doi.org\/10.1067\/mhj.2002.122516 (2002).","journal-title":"Am. Heart J."},{"key":"91610_CR40","doi-asserted-by":"publisher","first-page":"e137","DOI":"10.1161\/cir.0000000000000509","volume":"136","author":"CW Yancy","year":"2017","unstructured":"Yancy, C. W. et al. 2017 ACC\/AHA\/HFSA focused update of the 2013 ACCF\/AHA guideline for the management of heart failure: A report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure Society of America. Circulation 136, e137\u2013e161. https:\/\/doi.org\/10.1161\/cir.0000000000000509 (2017).","journal-title":"Circulation"},{"key":"91610_CR41","doi-asserted-by":"publisher","first-page":"e382","DOI":"10.1161\/CIR.0000000000000628v","volume":"140","author":"M Kusumoto Fred","year":"2019","unstructured":"Kusumoto Fred, M. et al. 2018 ACC\/AHA\/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: A report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation 140, e382\u2013e482. https:\/\/doi.org\/10.1161\/CIR.0000000000000628v (2019).","journal-title":"Circulation"},{"key":"91610_CR42","doi-asserted-by":"publisher","DOI":"10.1161\/jaha.116.005309","author":"W Huang","year":"2017","unstructured":"Huang, W. et al. Benefits of permanent his bundle pacing combined with atrioventricular node ablation in atrial fibrillation patients with heart failure with both preserved and reduced left ventricular ejection fraction. J. Am. Heart Assoc. https:\/\/doi.org\/10.1161\/jaha.116.005309 (2017).","journal-title":"J. Am. Heart Assoc."},{"key":"91610_CR43","doi-asserted-by":"publisher","first-page":"2123","DOI":"10.1056\/NEJMoa0907555","volume":"361","author":"C-M Yu","year":"2009","unstructured":"Yu, C.-M. et al. Biventricular pacing in patients with bradycardia and normal ejection fraction. N. Engl. J. Med. 361, 2123\u20132134. https:\/\/doi.org\/10.1056\/NEJMoa0907555 (2009).","journal-title":"N. Engl. J. Med."},{"key":"91610_CR44","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1016\/j.hrthm.2016.03.040","volume":"13","author":"G Dandamudi","year":"2016","unstructured":"Dandamudi, G. & Vijayaraman, P. How to perform permanent His bundle pacing in routine clinical practice. Heart Rhythm 13, 1362\u20131366. https:\/\/doi.org\/10.1016\/j.hrthm.2016.03.040 (2016).","journal-title":"Heart Rhythm"},{"key":"91610_CR45","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.1111\/pace.12904","volume":"39","author":"P Vijayaraman","year":"2016","unstructured":"Vijayaraman, P. & Dandamudi, G. How to perform permanent His bundle pacing: Tips and tricks. Pacing Clin. Electrophysiol. 39, 1298\u20131304. https:\/\/doi.org\/10.1111\/pace.12904 (2016).","journal-title":"Pacing Clin. Electrophysiol."},{"key":"91610_CR46","doi-asserted-by":"publisher","first-page":"e010972","DOI":"10.1161\/JAHA.118.010972","volume":"8","author":"JM Lewis Andrew","year":"2019","unstructured":"Lewis Andrew, J. M., Foley, P., Whinnett, Z., Keene, D. & Chandrasekaran, B. His bundle pacing: A new strategy for physiological ventricular activation. J. Am. Heart Assoc. 8, e010972. https:\/\/doi.org\/10.1161\/JAHA.118.010972 (2019).","journal-title":"J. Am. Heart Assoc."},{"key":"91610_CR47","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/s0300-8932(03)76860-2","volume":"56","author":"I Garc\u00eda-Bolao","year":"2003","unstructured":"Garc\u00eda-Bolao, I. et al. Biventricular pacing as a treatment for advanced heart failure. Preliminary experience in a series of 22 consecutive patients. Rev. Esp. Cardiol. 56, 245\u2013252. https:\/\/doi.org\/10.1016\/s0300-8932(03)76860-2 (2003).","journal-title":"Rev. Esp. Cardiol."},{"key":"91610_CR48","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1016\/j.hrthm.2017.12.022","volume":"15","author":"P Vijayaraman","year":"2018","unstructured":"Vijayaraman, P. et al. Permanent His-bundle pacing: Long-term lead performance and clinical outcomes. Heart Rhythm 15, 696\u2013702. https:\/\/doi.org\/10.1016\/j.hrthm.2017.12.022 (2018).","journal-title":"Heart Rhythm"},{"key":"91610_CR49","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1016\/j.hrthm.2019.06.016","volume":"16","author":"W Huang","year":"2019","unstructured":"Huang, W. et al. A beginner\u2019s guide to permanent left bundle branch pacing. Heart Rhythm 16, 1791\u20131796. https:\/\/doi.org\/10.1016\/j.hrthm.2019.06.016 (2019).","journal-title":"Heart Rhythm"},{"key":"91610_CR50","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1016\/j.hrthm.2019.04.043","volume":"16","author":"X Li","year":"2019","unstructured":"Li, X. et al. Permanent left bundle branch area pacing for atrioventricular block: Feasibility, safety, and acute effect. Heart Rhythm 16, 1766\u20131773. https:\/\/doi.org\/10.1016\/j.hrthm.2019.04.043 (2019).","journal-title":"Heart Rhythm"},{"key":"91610_CR51","doi-asserted-by":"publisher","first-page":"1758","DOI":"10.1016\/j.hrthm.2019.05.014","volume":"16","author":"Y Li","year":"2019","unstructured":"Li, Y. et al. Left bundle branch pacing for symptomatic bradycardia: Implant success rate, safety, and pacing characteristics. Heart Rhythm 16, 1758\u20131765. https:\/\/doi.org\/10.1016\/j.hrthm.2019.05.014 (2019).","journal-title":"Heart Rhythm"},{"key":"91610_CR52","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1136\/heartjnl-2018-313415","volume":"105","author":"W Huang","year":"2019","unstructured":"Huang, W. et al. Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block. Heart 105, 137\u2013143. https:\/\/doi.org\/10.1136\/heartjnl-2018-313415 (2019).","journal-title":"Heart"},{"key":"91610_CR53","doi-asserted-by":"publisher","first-page":"140","DOI":"10.14740\/cr495w","volume":"7","author":"SK Sinha","year":"2016","unstructured":"Sinha, S. K. et al. Fragmented QRS as a marker of electrical dyssynchrony to predict inter-ventricular conduction defect by subsequent echocardiographic assessment in symptomatic patients of non-ischemic dilated cardiomyopathy. Cardiol. Res. 7, 140\u2013145. https:\/\/doi.org\/10.14740\/cr495w (2016).","journal-title":"Cardiol. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91610-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91610-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91610-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T09:25:44Z","timestamp":1670059544000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91610-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,9]]},"references-count":53,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["91610"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-91610-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,9]]},"assertion":[{"value":"29 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12200"}}