{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T04:43:59Z","timestamp":1793335439062,"version":"4.5.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T00:00:00Z","timestamp":1623110400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T00:00:00Z","timestamp":1623110400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Unrestricted educational grant from Johnson and Johnson Vision"},{"name":"Ministry of Economy, Industry and Competitiveness of Spain within the program Ram\u00f3n y Cajal","award":["RYC-2016-20471"],"award-info":[{"award-number":["RYC-2016-20471"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson &amp; Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson &amp; Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r\u2009=\u20090.73, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.<\/jats:p>","DOI":"10.1038\/s41598-021-91654-w","type":"journal-article","created":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T10:07:47Z","timestamp":1623146867000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS"],"prefix":"10.1038","volume":"11","author":[{"given":"Carlos","family":"Palomino-Bautista","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rub\u00e9n","family":"S\u00e1nchez-Jean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Carmona-Gonzalez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1546-4807","authenticated-orcid":false,"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4854-3592","authenticated-orcid":false,"given":"Ainhoa","family":"Molina-Mart\u00edn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,8]]},"reference":[{"key":"91654_CR1","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.survophthal.2005.11.003","volume":"51","author":"B Wang","year":"2006","unstructured":"Wang, B. & Ciuffreda, K. J. Depth-of-focus of the human eye: Theory and clinical implications. Surv. Ophthalmol. 51, 75\u201385. https:\/\/doi.org\/10.1016\/j.survophthal.2005.11.003 (2006).","journal-title":"Surv. Ophthalmol."},{"key":"91654_CR2","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1016\/S0042-6989(98)00317-4","volume":"39","author":"S Marcos","year":"1999","unstructured":"Marcos, S., Moreno, E. & Navarro, R. The depth-of-field of the human eye from objective and subjective measurements. Vision Res. 39, 2039\u20132049. https:\/\/doi.org\/10.1016\/S0042-6989(98)00317-4 (1999).","journal-title":"Vision Res."},{"key":"91654_CR3","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1007\/s00417-016-3566-9","volume":"255","author":"A Bari\u0161i\u0107","year":"2017","unstructured":"Bari\u0161i\u0107, A., Patel, S., Gabric, N. & Feinbaum, C. G. The clinical depth of field achievable with trifocal and monofocal intraocular lenses: Theoretical considerations and proof of concept clinical results. Graefe\u2019s Arch. Clin. Exp. Ophthalmol. 255, 367\u2013373. https:\/\/doi.org\/10.1007\/s00417-016-3566-9 (2017).","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"91654_CR4","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1016\/j.jcrs.2008.04.031","volume":"34","author":"N Gupta","year":"2008","unstructured":"Gupta, N., Wolffsohn, J. S. W. & Naroo, S. A. Optimizing measurement of subjective amplitude of accommodation with defocus curves. J. Cataract. Refract. Surg. 34, 1329\u20131338. https:\/\/doi.org\/10.1016\/j.jcrs.2008.04.031 (2008).","journal-title":"J. Cataract. Refract. Surg."},{"key":"91654_CR5","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.jcrs.2013.01.031","volume":"39","author":"JS Wolffsohn","year":"2013","unstructured":"Wolffsohn, J. S. et al. Exploring the optimum step size for defocus curves. J. Cataract. Refract. Surg. 39, 873\u2013880. https:\/\/doi.org\/10.1016\/j.jcrs.2013.01.031 (2013).","journal-title":"J. Cataract. Refract. Surg."},{"key":"91654_CR6","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.clae.2007.02.005","volume":"30","author":"N Gupta","year":"2007","unstructured":"Gupta, N., Naroo, S. A. & Wolffsohn, J. S. Is randomisation necessary for measuring defocus curves in pre-presbyopes?. Contact Lens Anterior Eye 30, 119\u2013124. https:\/\/doi.org\/10.1016\/j.clae.2007.02.005 (2007).","journal-title":"Contact Lens Anterior Eye"},{"key":"91654_CR7","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1016\/S0886-3350(02)01317-2","volume":"28","author":"S Pieh","year":"2002","unstructured":"Pieh, S. et al. Comparison of visual acuities at different distances and defocus curves. J. Cataract. Refract. Surg. 28, 1964\u20131967. https:\/\/doi.org\/10.1016\/S0886-3350(02)01317-2 (2002).","journal-title":"J. Cataract. Refract. Surg."},{"key":"91654_CR8","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1016\/j.visres.2005.01.022","volume":"45","author":"DA Atchison","year":"2005","unstructured":"Atchison, D. A., Fisher, S. W., Pedersen, C. A. & Ridall, P. G. Noticeable, troublesome and objectionable limits of blur. Vis. Res. 45, 1967\u20131974. https:\/\/doi.org\/10.1016\/j.visres.2005.01.022 (2005).","journal-title":"Vis. Res."},{"key":"91654_CR9","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1007\/s00417-008-0923-3","volume":"246","author":"NM Sergienko","year":"2008","unstructured":"Sergienko, N. M., Kondratenko, Y. N. & Tutchenko, N. N. Depth of focus in pseudophakic eyes. Graefe\u2019s Arch. Clin. Exp. Ophthalmol. 246, 1623\u20131627. https:\/\/doi.org\/10.1007\/s00417-008-0923-3 (2008).","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"91654_CR10","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s10792-019-01186-6","volume":"40","author":"C Palomino-Bautista","year":"2020","unstructured":"Palomino-Bautista, C. et al. Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses. Int. Ophthalmol. 40, 351\u2013359. https:\/\/doi.org\/10.1007\/s10792-019-01186-6 (2020).","journal-title":"Int. Ophthalmol."},{"key":"91654_CR11","doi-asserted-by":"publisher","first-page":"3920","DOI":"10.1167\/iovs.11-9234","volume":"53","author":"PJ Buckhurst","year":"2012","unstructured":"Buckhurst, P. J. et al. Multifocal intraocular lens differentiation using defocus curves. Investig. Opthalmol. Vis. Sci. 53, 3920. https:\/\/doi.org\/10.1167\/iovs.11-9234 (2012).","journal-title":"Investig. Opthalmol. Vis. Sci."},{"key":"91654_CR12","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/S0008-4182(01)80040-5","volume":"36","author":"DS Kamlesh","year":"2001","unstructured":"Kamlesh, D. S. & Kaushik, S. Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens. Can. J. Ophthalmol. 36, 197\u2013201. https:\/\/doi.org\/10.1016\/S0008-4182(01)80040-5 (2001).","journal-title":"Can. J. Ophthalmol."},{"key":"91654_CR13","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1016\/S0161-6420(92)31735-X","volume":"99","author":"CT Post","year":"1992","unstructured":"Post, C. T. Comparison of depth of focus and low-contrast acuities for monofocal versus multifocal intraocular lens patients at 1 year. Ophthalmology 99, 1658\u20131664. https:\/\/doi.org\/10.1016\/S0161-6420(92)31735-X (1992).","journal-title":"Ophthalmology"},{"key":"91654_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1167\/4.4.8","volume":"4","author":"JD Marsack","year":"2004","unstructured":"Marsack, J. D., Thibos, L. N., Applegate, R. & a. ,. Metrics of optical quality derived from wave aberrations predict visual performance. J. Vis. 4, 8. https:\/\/doi.org\/10.1167\/4.4.8 (2004).","journal-title":"J. Vis."},{"key":"91654_CR15","unstructured":"Iskander DR, Molebna O, Molebny S, et al (2014) Objective DoF measurement based on through-focus augmented VSOTF. 2\u20135"},{"key":"91654_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1167\/10.4.3","volume":"10","author":"F Yi","year":"2010","unstructured":"Yi, F. Estimation of the depth of focus from wavefront measurements. J. Vis. 10, 1\u20139. https:\/\/doi.org\/10.1167\/10.4.3 (2010).","journal-title":"J. Vis."},{"key":"91654_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/6165493","volume":"2018","author":"S Escand\u00f3n-Garc\u00eda","year":"2018","unstructured":"Escand\u00f3n-Garc\u00eda, S. et al. Through-focus vision performance and light disturbances of 3 new intraocular lenses for presbyopia correction. J. Ophthalmol. 2018, 1\u20138. https:\/\/doi.org\/10.1155\/2018\/6165493 (2018).","journal-title":"J. Ophthalmol."},{"key":"91654_CR18","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1016\/j.jcrs.2006.06.017","volume":"32","author":"G Schmidinger","year":"2006","unstructured":"Schmidinger, G. et al. Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses. J. Cataract. Refract. Surg. 32, 1650\u20131656. https:\/\/doi.org\/10.1016\/j.jcrs.2006.06.017 (2006).","journal-title":"J. Cataract. Refract. Surg."},{"key":"91654_CR19","doi-asserted-by":"publisher","unstructured":"Ganesh, S., Brar, S., Pawar, A. & Relekar, K. J. Visual and refractive outcomes following bilateral implantation of extended range of vision intraocular lens with micromonovision. J. Ophthalmol. 2018, https:\/\/doi.org\/10.1155\/2018\/7321794 (2018).","DOI":"10.1155\/2018\/7321794"},{"issue":"96\u2013110","key":"91654_CR20","first-page":"1","volume":"3","author":"A Castillo-G\u00f3mez","year":"2012","unstructured":"Castillo-G\u00f3mez, A. et al. Principles and clinical applications of ray-tracing aberrometry. Emmetropia 3(96\u2013110), 1\u20132 (2012).","journal-title":"Emmetropia"},{"key":"91654_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-20344-x","volume":"8","author":"A Leube","year":"2018","unstructured":"Leube, A. et al. Individual neural transfer function affects the prediction of subjective depth of focus. Sci. Rep. 8, 1\u20138. https:\/\/doi.org\/10.1038\/s41598-018-20344-x (2018).","journal-title":"Sci. Rep."},{"key":"91654_CR22","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/S0886-3350(13)80616-5","volume":"19","author":"MC Knorz","year":"1993","unstructured":"Knorz, M. C. et al. Evaluation of contrast acuity and defocus curve in bifocal and monofocal intraocular lenses. J. Cataract. Refract. Surg. 19, 513\u2013523. https:\/\/doi.org\/10.1016\/S0886-3350(13)80616-5 (1993).","journal-title":"J. Cataract. Refract. Surg."},{"key":"91654_CR23","doi-asserted-by":"publisher","first-page":"1782","DOI":"10.18240\/ijo.2019.11.18","volume":"12","author":"MB Coco-Martin","year":"2019","unstructured":"Coco-Martin, M. B. et al. Potential of video games for the promotion of neuroadaptation to multifocal intraocular lenses: A narrative review. Int. J. Ophthalmol. 12, 1782\u20131787 (2019).","journal-title":"Int. J. Ophthalmol."},{"key":"91654_CR24","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.visres.2006.12.001","volume":"47","author":"KJ Ciuffreda","year":"2007","unstructured":"Ciuffreda, K. J., Wang, B. & Vasudevan, B. Conceptual model of human blur perception. Vis. Res. 47, 1245\u20131252. https:\/\/doi.org\/10.1016\/j.visres.2006.12.001 (2007).","journal-title":"Vis. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91654-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91654-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91654-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T09:33:26Z","timestamp":1670060006000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-91654-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,8]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["91654"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-91654-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,8]]},"assertion":[{"value":"9 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12081"}}