{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T21:38:25Z","timestamp":1769981905825,"version":"3.49.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,9,22]],"date-time":"2021-09-22T00:00:00Z","timestamp":1632268800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,22]],"date-time":"2021-09-22T00:00:00Z","timestamp":1632268800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100014584","name":"Universit\u00e4tsmedizin der Johannes Gutenberg-Universit\u00e4t Mainz","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100014584","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The Distal Tibia Nail (DTN; Mizuho, Japan) has demonstrated higher biomechanical stiffness to locking plates in previous research for A3 distal tibia fractures. It is here investigated as a fixation option for supramalleolar corrective osteotomies (SMOT). Sixteen Sawbones tibiae were implanted with either a DTN (n\u2009=\u20098) or Medial Distal Tibia Plate (MDTP; n\u2009=\u20098) and a SMOT simulated. Two surgical outcome scenarios were envisaged: \u201cbest-case\u201d representing an intact lateral cortex, and \u201cworst-case\u201d representing a fractured lateral cortex. All samples were subjected to compressive (350\u00a0N, 700\u00a0N) and torsional (\u00b1\u20094 Nm,\u2009\u00b1\u20098 Nm) testing. Samples were evaluated using calculated construct stiffness from force\u2013displacement data, interfragmentary movement and Von Mises\u2019 strain distribution. The DTN demonstrated a greater compressive stiffness for the best-case surgical scenario, whereas the MDTP showed higher stiffness (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05) for the worst-case surgical scenario. In torsional testing, the DTN proved more resistant to torsion in the worst-case surgical setup <jats:italic>(p<\/jats:italic>\u2009&lt;\u20090.05) for both\u2009\u00b1\u20094 Nm and\u2009\u00b1\u20098\u00a0Nm. The equivalent stiffness of the DTN against the MDTP supports the use of this implant for SMOT fixation and should be considered as a treatment option particularly in patients presenting vascularisation problems where the MDTP is an inappropriate choice.<\/jats:p>","DOI":"10.1038\/s41598-021-97968-z","type":"journal-article","created":{"date-parts":[[2021,9,22]],"date-time":"2021-09-22T10:03:10Z","timestamp":1632304990000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A comparative biomechanical study of the Distal Tibia Nail against compression plating for the osteosynthesis of supramalleolar corrective osteotomies"],"prefix":"10.1038","volume":"11","author":[{"given":"Julia","family":"Greenfield","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Appelmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoann","family":"Lafon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karine","family":"Bruy\u00e8re-Garnier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pol Maria","family":"Rommens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Kuhn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,9,22]]},"reference":[{"key":"97968_CR1","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.fcl.2011.11.002","volume":"17","author":"D Beaman","year":"2012","unstructured":"Beaman, D. & Gellman, R. Distal Tibial Varus. Foot Ankle Clin. 17, 83\u201393. https:\/\/doi.org\/10.1016\/j.fcl.2011.11.002 (2012).","journal-title":"Foot Ankle Clin."},{"key":"97968_CR2","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.2106\/JBJS.J.00249","volume":"93","author":"W-C Lee","year":"2011","unstructured":"Lee, W.-C., Moon, J.-S., Lee, K., Byun, W. J. & Lee, S. H. Indications for supramalleolar osteotomy in patients with ankle osteoarthritis and varus deformity. J. Bone Joint Surg. Am. 93, 1243\u20131248. https:\/\/doi.org\/10.2106\/JBJS.J.00249 (2011).","journal-title":"J. Bone Joint Surg. Am."},{"key":"97968_CR3","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1097\/BLO.0b013e318124a462","volume":"462","author":"GI Pagenstert","year":"2007","unstructured":"Pagenstert, G. I., Hintermann, B., Barg, A., Leumann, A. & Valderrabano, V. Realignment surgery as alternative treatment of varus and valgus ankle osteoarthritis. Clin. Orthop. Relat. Res. 462, 156\u2013168. https:\/\/doi.org\/10.1097\/BLO.0b013e318124a462 (2007).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"97968_CR4","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.otsr.2013.12.027","volume":"100","author":"F Colin","year":"2014","unstructured":"Colin, F., Gaudot, F., Odri, G. & Judet, T. Supramalleolar osteotomy: techniques, indications and outcomes in a series of 83 cases. Orthop. Traumatol. Surg. Res. 100, 413\u2013418. https:\/\/doi.org\/10.1016\/j.otsr.2013.12.027 (2014).","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"97968_CR5","doi-asserted-by":"publisher","first-page":"3904","DOI":"10.1002\/art.20726","volume":"50","author":"DT Felson","year":"2014","unstructured":"Felson, D. T. et al. The effect of body weight on progression of knee osteoarthritis is dependent on alignment. Arthritis Rheumatol. 50, 3904\u20133909. https:\/\/doi.org\/10.1002\/art.20726 (2014).","journal-title":"Arthritis Rheumatol."},{"key":"97968_CR6","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1002\/1529-0131(200003)43:3<568::AID-ANR13>3.0.CO;2-E","volume":"43","author":"L Sharma","year":"2000","unstructured":"Sharma, L., Lou, C., Cahue, S. & Dunlop, D. D. The mechanism of the effect of obesity in knee osteoarthritis: the mediating role of malalignment. Arthritis Rheumatol. 43, 568\u2013575. https:\/\/doi.org\/10.1002\/1529-0131(200003)43:3%3c568::AID-ANR13%3e3.0.CO;2-E (2000).","journal-title":"Arthritis Rheumatol."},{"key":"97968_CR7","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1007\/s00064-008-1308-9","volume":"20","author":"M Knupp","year":"2008","unstructured":"Knupp, M., Pagenstert, G., Valderraban, V. & Hintermann, B. Osteotomien zur Entlastung der Varusarthrose im oberen Sprunggelenk. Oper. Orthop. Traumatol. 20, 262\u2013273. https:\/\/doi.org\/10.1007\/s00064-008-1308-9 (2008).","journal-title":"Oper. Orthop. Traumatol."},{"key":"97968_CR8","volume-title":"Becken und untere Extremit\u00e4t, Teil 2","author":"R Bauer","year":"1994","unstructured":"Bauer, R. et al. Orthop\u00e4dische Operationslehre. In Becken und untere Extremit\u00e4t, Teil 2 (ed. Bauer, R., Kirchbaumer, F. & Peisel, S.) (Georg Thieme Verlag, 1994)."},{"key":"97968_CR9","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1007\/s00402-018-2981-2","volume":"138","author":"S Ettinger","year":"2018","unstructured":"Ettinger, S. et al. Stability of supramalleolar osteotomies using different implants in a sawbone model. Arch. Orthop. Trauma Surg. 138, 1359\u20131363. https:\/\/doi.org\/10.1007\/s00402-018-2981-2 (2018).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"97968_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-9-35","author":"S Kuhn","year":"2014","unstructured":"Kuhn, S., Appelmann, P., Mehler, D., Pairon, P. & Rommens, P. M. Retrograde tibial nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures. J. Orthop. Surg. Res. https:\/\/doi.org\/10.1186\/1749-799X-9-35 (2014).","journal-title":"J. Orthop. Surg. Res."},{"key":"97968_CR11","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1177\/1071100715597438","volume":"37","author":"KW Nha","year":"2016","unstructured":"Nha, K. W. et al. Safe zone for medial open-wedge supramalleolar osteotomy of the ankle: A cadaveric study. Foot Ankle Int. 37, 102\u2013108. https:\/\/doi.org\/10.1177\/1071100715597438 (2016).","journal-title":"Foot Ankle Int."},{"key":"97968_CR12","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.1177\/1071100713500473","volume":"34","author":"T Schmid","year":"2013","unstructured":"Schmid, T. et al. Ankle joint pressure changes in a pes cavovarus model: supramalleolar valgus osteotomy versus lateralizing calcaneal osteotomy. Foot Ankle. Int. 34, 1190\u20131197. https:\/\/doi.org\/10.1177\/1071100713500473 (2013).","journal-title":"Foot Ankle. Int."},{"key":"97968_CR13","doi-asserted-by":"publisher","first-page":"S81","DOI":"10.1016\/j.injury.2013.10.025","volume":"455","author":"S Kuhn","year":"2014","unstructured":"Kuhn, S., Appelmann, P., Pairon, P., Mehler, D. & Rommens, P. M. The retrograde tibial nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures. Injury 455, S81\u2013S86. https:\/\/doi.org\/10.1016\/j.injury.2013.10.025 (2014).","journal-title":"Injury"},{"key":"97968_CR14","doi-asserted-by":"publisher","first-page":"1255","DOI":"10.1007\/s00264-013-2267-9","volume":"38","author":"S Kuhn","year":"2014","unstructured":"Kuhn, S. et al. A new angle stable nailing concept for the treatment of distal tibia fractures. Int. Orthop. (SICOT) 38, 1255\u20131260. https:\/\/doi.org\/10.1007\/s00264-013-2267-9 (2014).","journal-title":"Int. Orthop. (SICOT)"},{"key":"97968_CR15","doi-asserted-by":"publisher","first-page":"675","DOI":"10.5435\/JAAOS-20-11-675","volume":"20","author":"C Casstevens","year":"2012","unstructured":"Casstevens, C., Toan, L., Archdeacon, M. T. & Wyrick, J. D. Management of extra-articular fractures of the distal tibia: intramedullary nailing versus plate fixation. J. Am. Acad. Orthop. Surg. 20, 675\u2013683. https:\/\/doi.org\/10.5435\/JAAOS-20-11-675 (2012).","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"97968_CR16","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s00068-014-0448-x","volume":"41","author":"P Pairon","year":"2015","unstructured":"Pairon, P., Ossendorf, C., Kuhn, S., Hofmann, A. & Rommens, P. M. Intramedullary nailing after external fixation of the femur and tibia: A review of advantages and limits. Eur. J. Trauma Emerg. Surg. 41, 25\u201338. https:\/\/doi.org\/10.1007\/s00068-014-0448-x (2015).","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"97968_CR17","unstructured":"Arbeitsgemeinschaft f\u00fcr Osteosynthesenfragen. MIPO\u2014Bridge plating of 43-A3.1\/3.2 fractures. AO Surgery Reference (2008). https:\/\/surgeryreference.aofoundation.org\/"},{"key":"97968_CR18","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.clinbiomech.2016.08.007","volume":"38","author":"JG Galbraith","year":"2016","unstructured":"Galbraith, J. G., Daly, C. J., Harty, J. A. & Dailey, H. L. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing. Clin. Biomech. 38, 42\u201349. https:\/\/doi.org\/10.1016\/j.clinbiomech.2016.08.007 (2016).","journal-title":"Clin. Biomech."},{"key":"97968_CR19","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.jmbbm.2015.06.006","volume":"50","author":"L Grassi","year":"2015","unstructured":"Grassi, L. & Isaksson, H. Extracting accurate strain measurements in bone mechanics: A critical review of current methods. J. Mech. Behav. Biomed. Mater. 50, 43\u201354. https:\/\/doi.org\/10.1016\/j.jmbbm.2015.06.006 (2015).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"97968_CR20","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/B978-0-12-803802-4.00005-6","volume-title":"Experimental Methods in Orthopaedic Biomechanics","author":"K Rankin","year":"2017","unstructured":"Rankin, K., Browne, M. & Dickinson, A. Digital image correlation for strain analysis of whole bones and implants. In Experimental Methods in Orthopaedic Biomechanics (ed. Zdero, R.) 65\u201383 (Academic Press, 2017)."},{"key":"97968_CR21","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s00068-012-0237-3","volume":"39","author":"F H\u00f6gel","year":"2013","unstructured":"H\u00f6gel, F., Gerber, C., B\u00fchren, V. & Augat, P. Reamed intramedullary nailing of diaphyseal tibial fractures: Comparison of compression and non-compression nailing. Eur. J. Trauma Emerg. Surg. 39, 73\u201377. https:\/\/doi.org\/10.1007\/s00068-012-0237-3 (2013).","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"97968_CR22","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1177\/0954411916638684","volume":"230","author":"BR Rastetter","year":"2016","unstructured":"Rastetter, B. R., Wright, S. J., Gheduzzi, S., Miles, A. W. & Clift, S. E. The influence of tibial component malalignment on bone strain in revision total knee replacement. Proc. Inst. Mech. Eng. H. 230, 561\u2013568. https:\/\/doi.org\/10.1177\/0954411916638684 (2016).","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"97968_CR23","doi-asserted-by":"publisher","first-page":"e0192225","DOI":"10.1371\/journal.pone.0192225","volume":"13","author":"P Moewis","year":"2018","unstructured":"Moewis, P., Checa, S., Kutzner, I., Hommel, H. & Duda, G. N. Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement\u2014A finite element analysis. PLoS ONE 13, e0192225. https:\/\/doi.org\/10.1371\/journal.pone.0192225 (2018).","journal-title":"PLoS ONE"},{"key":"97968_CR24","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1016\/j.jspi.2007.06.036","volume":"138","author":"H Peng","year":"2008","unstructured":"Peng, H., Wang, S. & Wang, X. Consistency and asymptotic distribution of the Theil-Sen estimator. J. Stat. Plan. Inference 138, 1836\u20131850. https:\/\/doi.org\/10.1016\/j.jspi.2007.06.036 (2008).","journal-title":"J. Stat. Plan. Inference"},{"key":"97968_CR25","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.clinbiomech.2006.01.003","volume":"21","author":"DR Epari","year":"2006","unstructured":"Epari, D. R., Taylor, W. R., Heller, M. O. & Duda, G. N. Mechanical conditions in the initial phase of bone healing. Clin. Biomech. 21, 646\u2013655. https:\/\/doi.org\/10.1016\/j.clinbiomech.2006.01.003 (2006).","journal-title":"Clin. Biomech."},{"key":"97968_CR26","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/0169-6009(92)90875-E","volume":"19","author":"HM Frost","year":"1992","unstructured":"Frost, H. M. Perspectives: bone\u2019s mechanical usage windows. Bone Miner. 19, 257\u2013271. https:\/\/doi.org\/10.1016\/0169-6009(92)90875-E (1992).","journal-title":"Bone Miner."},{"key":"97968_CR27","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1007\/BF00302070","volume":"57","author":"RL Duncan","year":"1995","unstructured":"Duncan, R. L. & Turner, C. H. Mechanotransduction and the functional response of bone to mechanical strain. Calcif. Tissue Int. 57, 344\u2013358. https:\/\/doi.org\/10.1007\/BF00302070 (1995).","journal-title":"Calcif. Tissue Int."},{"key":"97968_CR28","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1615\/CritRevEukarGeneExpr.v19.i4.50","volume":"19","author":"AG Robling","year":"2009","unstructured":"Robling, A. G. & Turner, C. H. Mechanical signaling for bone modeling and remodeling. Crit. Rev. Eukaryot. Gene 19, 319\u2013338 (2009).","journal-title":"Crit. Rev. Eukaryot. Gene"},{"key":"97968_CR29","first-page":"E81","volume":"72","author":"MA Ahmad","year":"2012","unstructured":"Ahmad, M. A., Sivaraman, A., Zia, A., Rai, A. & Patel, A. D. Percutaneous locking plates for fractures of the distal tibia: Our experience and a review of the literature. J. Trauma 72, E81\u2013E87 (2012).","journal-title":"J. Trauma"},{"key":"97968_CR30","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s00590-013-1362-3","volume":"25","author":"B Li","year":"2015","unstructured":"Li, B., Yang, Y. & Jiang, L.-S. Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: a system review. Eur. J. Orthop. Surg. Traumatol. 25, 53\u201363 (2015).","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"97968_CR31","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s00264-007-0384-z","volume":"35","author":"TW Lau","year":"2008","unstructured":"Lau, T. W., Leung, F., Chan, C. F. & Chow, S. P. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int. Orthop. 35, 697\u2013703. https:\/\/doi.org\/10.1007\/s00264-007-0384-z (2008).","journal-title":"Int. Orthop."},{"key":"97968_CR32","doi-asserted-by":"publisher","first-page":"1285","DOI":"10.1007\/s00264-009-0880-4","volume":"34","author":"RK Gupta","year":"2010","unstructured":"Gupta, R. K., Rohilla, R. K., Sangwan, K., Singh, V. & Walia, S. Locking plate fixation in distal metaphyseal tibial fractures: Series of 79 patients. Int. Orthop. 34, 1285\u20131285. https:\/\/doi.org\/10.1007\/s00264-009-0880-4 (2010).","journal-title":"Int. Orthop."},{"key":"97968_CR33","volume-title":"Surgical Technique Distal Tibia Nail (DTN)","author":"S Kuhn","year":"2017","unstructured":"Kuhn, S. & Rommens, P. M. Surgical Technique Distal Tibia Nail (DTN) (Mizuho OSI\u00ae, 2017)."},{"key":"97968_CR34","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"AD Heiner","year":"2008","unstructured":"Heiner, A. D. Structural properties of fourth-generation composite femurs and tibias. J. Biomech. 41, 3282\u20133284 (2008).","journal-title":"J. Biomech."},{"key":"97968_CR35","first-page":"613","volume":"38","author":"MP Gardner","year":"2010","unstructured":"Gardner, M. P., Chong, A. C. M., Pollock, A. G. & Wooley, P. H. Mechanical evaluation of large-sized fourth-generation composite femur and tibia models. J. Biomed. Eng. 38, 613\u2013620 (2010).","journal-title":"J. Biomed. Eng."},{"key":"97968_CR36","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1016\/j.injury.2011.03.031","volume":"42","author":"R Marsell","year":"2011","unstructured":"Marsell, R. & Einhorn, T. A. The biology of fracture healing. Injury 42, 551\u2013555. https:\/\/doi.org\/10.1016\/j.injury.2011.03.031 (2011).","journal-title":"Injury"},{"key":"97968_CR37","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.mpsur.2017.10.005","volume":"36","author":"T Nyary","year":"2018","unstructured":"Nyary, T. & Scammell, B. E. Principles of bone and joint injuries and their healing. Surg. Oxf. Int. Ed. 36, 7\u201314. https:\/\/doi.org\/10.1016\/j.mpsur.2017.10.005 (2018).","journal-title":"Surg. Oxf. Int. Ed."},{"key":"97968_CR38","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.jmbbm.2019.07.015","volume":"99","author":"R Meeson","year":"2019","unstructured":"Meeson, R. The influence of gap size on the development of fracture union with a micro external fixator. J. Mech. Behav. Biomed. Mater. 99, 161\u2013168 (2019).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"97968_CR39","doi-asserted-by":"publisher","first-page":"S132","DOI":"10.1097\/00003086-199810001-00015","volume":"355","author":"LE Claes","year":"1998","unstructured":"Claes, L. E. et al. Effects of mechanical factors on the fracture healing process. Clin. Orthop. Relat. Res. 355, S132\u2013S147 (1998).","journal-title":"Clin. Orthop. Relat. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-97968-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-97968-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-97968-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T16:03:31Z","timestamp":1670083411000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-97968-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,22]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["97968"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-97968-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,22]]},"assertion":[{"value":"26 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18834"}}