{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T14:42:48Z","timestamp":1788878568856,"version":"build-2803163510"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,10,5]],"date-time":"2021-10-05T00:00:00Z","timestamp":1633392000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,5]],"date-time":"2021-10-05T00:00:00Z","timestamp":1633392000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Migration of duodenal covered self-expandable metal stents (C-SEMSs) is the main cause of stent dysfunction in patients with malignant gastric outlet obstruction (mGOO). Because endoscopic SEMS placement is frequently selected in patients with poor performance status, we concurrently focused on the safety of the treatment. This pilot study included 15 consecutive patients with mGOO who underwent duodenal partially covered SEMS (PC-SEMS) placement with fixation using an over-the-scope-clip (OTSC). Technical feasibility, clinical success for oral intake estimated by the Gastric Outlet Obstruction Scoring System (GOOSS) score, and adverse events including stent migration were retrospectively assessed. All procedures were successful, and clinical success was achieved in 86.7% (13\/15). Mean GOOSS scores were improved from 0.07 to 2.53 after the procedure (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). Median survival time was 84\u00a0days, and all patients were followed up until death. Stent migration occurred in one case (6.7%) at day 17, which was successfully treated by removal of the migrated PC-SEMS using an enteroscope. For fixation using an OTSC, additional time required for the procedure was 8.9\u2009\u00b1\u20094.1\u00a0min and we did not observe OTSC-associated adverse events. Poor performance status was associated with clinical success (<jats:italic>P<\/jats:italic>\u2009=\u20090.03), but we could provide the treatment safely and reduce mGOO symptoms even in patients with poor performance status. In conclusion, duodenal PC-SEMS fixation using an OTSC is feasible for preventing stent migration in patients with mGOO including those with poor performance status.<\/jats:p>","DOI":"10.1038\/s41598-021-99265-1","type":"journal-article","created":{"date-parts":[[2021,10,5]],"date-time":"2021-10-05T13:52:53Z","timestamp":1633441973000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["A pilot study of novel duodenal covered self-expandable metal stent fixation"],"prefix":"10.1038","volume":"11","author":[{"given":"Yasuki","family":"Hori","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuki","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Itaru","family":"Naitoh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuyuki","family":"Miyabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Natsume","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michihiro","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromi","family":"Kataoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,5]]},"reference":[{"key":"99265_CR1","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.gie.2009.09.042","volume":"71","author":"SM Jeurnink","year":"2010","unstructured":"Jeurnink, S. M. et al. Surgical gastrojejunostomy or endoscopic stent placement for the palliation of malignant gastric outlet obstruction (SUSTENT study): A multicenter randomized trial. Gastrointest. Endosc. 71, 490\u2013499 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR2","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s00464-005-0130-9","volume":"20","author":"S Mehta","year":"2006","unstructured":"Mehta, S. et al. Prospective randomized trial of laparoscopic gastrojejunostomy versus duodenal stenting for malignant gastric outflow obstruction. Surg. Endosc. 20, 239\u2013242 (2006).","journal-title":"Surg. Endosc."},{"key":"99265_CR3","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1055\/s-0032-1309893","volume":"44","author":"CG Kim","year":"2012","unstructured":"Kim, C. G. et al. Effect of chemotherapy on the outcome of self-expandable metallic stents in gastric cancer patients with malignant outlet obstruction. Endoscopy 44, 807\u2013812 (2012).","journal-title":"Endoscopy"},{"key":"99265_CR4","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.pan.2016.07.007","volume":"16","author":"S Kobayashi","year":"2016","unstructured":"Kobayashi, S. et al. Duodenal stenting followed by systemic chemotherapy for patients with pancreatic cancer and gastric outlet obstruction. Pancreatology 16, 1085\u20131091 (2016).","journal-title":"Pancreatology"},{"key":"99265_CR5","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.gie.2020.07.063","volume":"93","author":"TL Jue","year":"2021","unstructured":"Jue, T. L. et al. ASGE guideline on the role of endoscopy in the management of benign and malignant gastroduodenal obstruction. Gastrointest. Endosc. 93, 309-322.e4 (2021).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.gie.2010.01.039","volume":"72","author":"CG Kim","year":"2010","unstructured":"Kim, C. G. et al. Covered versus uncovered self-expandable metallic stents for palliation of malignant pyloric obstruction in gastric cancer patients: A randomized, prospective study. Gastrointest. Endosc. 72, 25\u201332 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR7","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/j.dld.2014.02.024","volume":"46","author":"SG Lim","year":"2014","unstructured":"Lim, S. G. et al. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: A randomized prospective study. Dig. Liver Dis. 46, 603\u2013608 (2014).","journal-title":"Dig. Liver Dis."},{"key":"99265_CR8","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1111\/den.12117","volume":"26","author":"I Maetani","year":"2014","unstructured":"Maetani, I. et al. Placement of a triple-layered covered versus uncovered metallic stent for palliation of malignant gastric outlet obstruction: A multicenter randomized trial. Dig. Endosc. 26, 192\u2013199 (2014).","journal-title":"Dig. Endosc."},{"key":"99265_CR9","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1038\/ajg.2015.286","volume":"110","author":"H Lee","year":"2015","unstructured":"Lee, H. et al. Covered metallic stents with an anti-migration design vs. uncovered stents for the palliation of malignant gastric outlet obstruction: A multicenter, randomized trial. Am. J. Gastroenterol. 110, 1440\u20131449 (2015).","journal-title":"Am. J. Gastroenterol."},{"key":"99265_CR10","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1136\/gutjnl-2020-320775","volume":"70","author":"K Yamao","year":"2020","unstructured":"Yamao, K. et al. Endoscopic placement of covered versus uncovered self-expandable metal stents for palliation of malignant gastric outlet obstruction. Gut 70, 1244\u20131252 (2020).","journal-title":"Gut"},{"key":"99265_CR11","doi-asserted-by":"publisher","first-page":"4165","DOI":"10.1007\/s00464-017-5471-7","volume":"31","author":"Y Hori","year":"2017","unstructured":"Hori, Y. et al. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: Tumor ingrowth in uncovered stents and migration of covered stents. Surg. Endosc. 31, 4165\u20134173 (2017).","journal-title":"Surg. Endosc."},{"key":"99265_CR12","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.gie.2016.07.048","volume":"85","author":"Y Hori","year":"2017","unstructured":"Hori, Y. et al. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: A multicenter study. Gastrointest. Endosc. 85, 340-348.e1 (2017).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR13","doi-asserted-by":"publisher","first-page":"3587","DOI":"10.1007\/s00520-018-4221-2","volume":"26","author":"Y Hori","year":"2018","unstructured":"Hori, Y. et al. The utility and efficacy of self-expandable metal stents for treating malignant gastric outlet obstructions in patients under best supportive care. Support Care Cancer 26, 3587\u20133592 (2018).","journal-title":"Support Care Cancer"},{"key":"99265_CR14","first-page":"2091","volume":"55","author":"S Bang","year":"2008","unstructured":"Bang, S. et al. Effectiveness of self-expanding metal stents for malignant antropyloric and duodenal obstruction with a comparison between covered and uncovered stents. Hepatogastroenterology 55, 2091\u20132095 (2008).","journal-title":"Hepatogastroenterology"},{"key":"99265_CR15","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1080\/00365520902929849","volume":"44","author":"KM Lee","year":"2009","unstructured":"Lee, K. M. et al. Palliative treatment of malignant gastroduodenal obstruction with metallic stent: Prospective comparison of covered and uncovered stents. Scand. J. Gastroenterol. 44, 846\u2013852 (2009).","journal-title":"Scand. J. Gastroenterol."},{"key":"99265_CR16","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1016\/j.gie.2008.06.009","volume":"69","author":"I Maetani","year":"2009","unstructured":"Maetani, I. et al. Metallic stents for gastric outlet obstruction: Reintervention rate is lower with uncovered versus covered stents, despite similar outcomes. Gastrointest. Endosc. 69, 806\u2013812 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR17","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.gie.2011.11.035","volume":"75","author":"H Isayama","year":"2012","unstructured":"Isayama, H. et al. Management of malignant gastric outlet obstruction with a modified triple-layer covered metal stent. Gastrointest. Endosc. 75, 757\u2013763 (2012).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR18","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.dld.2012.08.021","volume":"45","author":"CI Park","year":"2013","unstructured":"Park, C. I. et al. What is the ideal stent as initial intervention for malignant gastric outlet obstruction?. Dig. Liver Dis. 45, 33\u201337 (2013).","journal-title":"Dig. Liver Dis."},{"key":"99265_CR19","doi-asserted-by":"publisher","first-page":"2031","DOI":"10.1007\/s00464-012-2705-6","volume":"27","author":"SM Woo","year":"2013","unstructured":"Woo, S. M. et al. Comparison of uncovered and covered stents for the treatment of malignant duodenal obstruction caused by pancreaticobiliary cancer. Surg. Endosc. 27, 2031\u20132039 (2013).","journal-title":"Surg. Endosc."},{"key":"99265_CR20","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.3748\/wjg.v21.i5.1580","volume":"21","author":"JW Kim","year":"2015","unstructured":"Kim, J. W. et al. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction. World J. Gastroenterol. 21, 1580\u20131587 (2015).","journal-title":"World J. Gastroenterol."},{"key":"99265_CR21","doi-asserted-by":"publisher","first-page":"4001","DOI":"10.1007\/s00464-015-4712-x","volume":"30","author":"K Jung","year":"2016","unstructured":"Jung, K. et al. Outcomes of endoscopically inserted self-expandable metal stents in malignancy according to the type of stent and the site of obstruction. Surg. Endosc. 30, 4001\u20134010 (2016).","journal-title":"Surg. Endosc."},{"key":"99265_CR22","doi-asserted-by":"publisher","first-page":"481","DOI":"10.5009\/gnl16259","volume":"11","author":"N Takahara","year":"2017","unstructured":"Takahara, N. et al. A novel partially covered self-expandable metallic stent with proximal flare in patients with malignant gastric outlet obstruction. Gut Liver 11, 481\u2013488 (2017).","journal-title":"Gut Liver"},{"key":"99265_CR23","doi-asserted-by":"publisher","first-page":"3409","DOI":"10.1007\/s10620-018-5284-0","volume":"63","author":"YK Choi","year":"2018","unstructured":"Choi, Y. K. et al. Winged partially covered self-expandable metal stent to prevent distal migration in malignant gastric outlet obstruction. Dig. Dis. Sci. 63, 3409\u20133416 (2018).","journal-title":"Dig. Dis. Sci."},{"key":"99265_CR24","doi-asserted-by":"publisher","first-page":"4540138","DOI":"10.1155\/2018\/4540138","volume":"2018","author":"JW Choe","year":"2018","unstructured":"Choe, J. W. et al. Comparison on the efficacy between partially covered self-expandable metal stent with funnel-shaped enlarged head versus uncovered self-expandable metal stent for palliation of gastric outlet obstruction. Gastroenterol. Res. Pract. 2018, 4540138 (2018).","journal-title":"Gastroenterol. Res. Pract."},{"key":"99265_CR25","doi-asserted-by":"publisher","first-page":"100","DOI":"10.3109\/00365520903410554","volume":"45","author":"ID Kim","year":"2010","unstructured":"Kim, I. D. et al. Prevention of covered enteral stent migration in patients with malignant gastric outlet obstruction: A pilot study of anchoring with endoscopic clips. Scand. J. Gastroenterol. 45, 100\u2013105 (2010).","journal-title":"Scand. J. Gastroenterol."},{"key":"99265_CR26","doi-asserted-by":"publisher","first-page":"4026","DOI":"10.1007\/s00464-019-06694-1","volume":"33","author":"Y Hori","year":"2019","unstructured":"Hori, Y. et al. Feasibility and safety of duodenal covered self-expandable metallic stent fixation: An experimental study. Surg. Endosc. 33, 4026\u20134031 (2019).","journal-title":"Surg. Endosc."},{"key":"99265_CR27","doi-asserted-by":"publisher","first-page":"3495","DOI":"10.3748\/wjg.v26.i24.3495","volume":"26","author":"N Bartell","year":"2020","unstructured":"Bartell, N. et al. Clinical efficacy of the over-the-scope clip device: A systematic review. World J. Gastroenterol. 26, 3495\u20133516 (2020).","journal-title":"World J. Gastroenterol."},{"key":"99265_CR28","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.1055\/s-0034-1377916","volume":"46","author":"S Mudumbi","year":"2014","unstructured":"Mudumbi, S. et al. Anchoring of self-expanding metal stents using the over-the-scope clip, and a technique for subsequent removal. Endoscopy 46, 1106\u20131109 (2014).","journal-title":"Endoscopy"},{"key":"99265_CR29","doi-asserted-by":"publisher","first-page":"E339","DOI":"10.1055\/a-0915-1756","volume":"51","author":"Y Hori","year":"2019","unstructured":"Hori, Y. et al. Successful peroral endoscopic removal of migrated metal stent. Endoscopy 51, E339-e340 (2019).","journal-title":"Endoscopy"},{"key":"99265_CR30","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.gie.2008.09.032","volume":"70","author":"H Isayama","year":"2009","unstructured":"Isayama, H. et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointest. Endosc. 70, 37\u201344 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"99265_CR31","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1111\/jgh.14993","volume":"35","author":"V Zimmer","year":"2020","unstructured":"Zimmer, V. Gastrointestinal: Utilization of a novel dedicated stent fixation clip device (\u201cstentfix OTSC\u201d) for an umbrella-type cardia stent. J. Gastroenterol. Hepatol. 35, 1466 (2020).","journal-title":"J. Gastroenterol. Hepatol."},{"key":"99265_CR32","doi-asserted-by":"publisher","first-page":"2002","DOI":"10.1002\/1097-0142(19840501)53:9<2002::AID-CNCR2820530933>3.0.CO;2-W","volume":"53","author":"V Mor","year":"1984","unstructured":"Mor, V. et al. The Karnofsky Performance Status Scale. An examination of its reliability and validity in a research setting. Cancer 53, 2002\u20132007 (1984).","journal-title":"Cancer"},{"key":"99265_CR33","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1111\/j.1572-0241.2002.05423.x","volume":"97","author":"DG Adler","year":"2002","unstructured":"Adler, D. G. & Baron, T. H. Endoscopic palliation of malignant gastric outlet obstruction using self-expanding metal stents: Experience in 36 patients. Am. J. Gastroenterol. 97, 72\u201378 (2002).","journal-title":"Am. J. Gastroenterol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-99265-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-99265-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-99265-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T16:05:39Z","timestamp":1670083539000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-021-99265-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,5]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["99265"],"URL":"https:\/\/doi.org\/10.1038\/s41598-021-99265-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,5]]},"assertion":[{"value":"19 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19708"}}