{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,13]],"date-time":"2026-09-13T02:55:38Z","timestamp":1789268138827,"version":"build-2803163510"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T00:00:00Z","timestamp":1643760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T00:00:00Z","timestamp":1643760000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100017480","name":"Chang Bing Show Chwan Memorial Hospital","doi-asserted-by":"publisher","award":["CSMU-SHOW-105-01"],"award-info":[{"award-number":["CSMU-SHOW-105-01"]}],"id":[{"id":"10.13039\/501100017480","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Surgical smoke is a common chemical hazard produced from the use of electrocautery, laser, or ultrasonic scalpels during surgery. It has been proved harmful to medical personnel. Thus, it is important to monitor surgical smoke concentrations in the operating room. In the past decade, many researches regarding surgical smoke were discussed in different professional healthcare fields, but few showed the correlation between surgical smoke and otolaryngology surgery. In this study, the concentrations of particulate matter and formaldehyde were measured during thirty cases of several types of otolaryngology surgery in a regional research hospital in Taiwan. The concentrations of 0.3\u00a0\u00b5m and 0.5\u00a0\u00b5m particulate matter raised rapidly in the main knife range at the beginning of the electrocautery knife used, and then decreased by half after 5\u201310\u00a0min of use. The concentrations of formaldehyde were ranged from 1 to 2\u00a0ppm during the surgery, which is higher than the permissible exposure limit. While many medical staffs are working in the operating room and are exposed to the smoke hazard, effective strategies for collecting and eliminating the smoke should be taken in all medical facilities.<\/jats:p>","DOI":"10.1038\/s41598-022-05701-1","type":"journal-article","created":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T06:06:03Z","timestamp":1643781963000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Investigating surgical smoke in otolaryngology operating rooms"],"prefix":"10.1038","volume":"12","author":[{"given":"Chun-I.","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying-Hsiang","family":"Chou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jar-Yuan","family":"Pai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chih-Hsuan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min-Chi","family":"Chiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,2]]},"reference":[{"key":"5701_CR1","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/s0002-9343(97)89441-7","volume":"102","author":"DM Bell","year":"1997","unstructured":"Bell, D. M. Occupational risk of human immunodeficiency virus infection in healthcare workers: An overview. Am. J. Med. 102, 9\u201315. https:\/\/doi.org\/10.1016\/s0002-9343(97)89441-7 (1997).","journal-title":"Am. J. Med."},{"key":"5701_CR2","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1086\/502378","volume":"25","author":"C Wendt","year":"2004","unstructured":"Wendt, C., Knautz, D. & von Baum, H. Differences in hand hygiene behavior related to the contamination risk of healthcare activities in different groups of healthcare workers. Infect. Control Hosp. Epidemiol. 25, 203\u2013206. https:\/\/doi.org\/10.1086\/502378 (2004).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"5701_CR3","unstructured":"Centers for Disease Control and Prevention. Workplace Safety and Health Topics- Healthcare Workers. https:\/\/www.cdc.gov\/niosh\/topics\/healthcare\/."},{"key":"5701_CR4","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1136\/oemed-2020-106567","volume":"77","author":"MR Sim","year":"2020","unstructured":"Sim, M. R. The COVID-19 pandemic: Major risks to healthcare and other workers on the front line. Occup. Environ. Med. 77, 281\u2013282. https:\/\/doi.org\/10.1136\/oemed-2020-106567 (2020).","journal-title":"Occup. Environ. Med."},{"key":"5701_CR5","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1038\/s42256-020-00238-2","volume":"2","author":"A Zemmar","year":"2020","unstructured":"Zemmar, A., Lozano, A. M. & Nelson, B. J. The rise of robots in surgical environments during COVID-19. Nat. Mach. Intell. 2, 566\u2013572. https:\/\/doi.org\/10.1038\/s42256-020-00238-2 (2020).","journal-title":"Nat. Mach. Intell."},{"key":"5701_CR6","unstructured":"The Occupational Safety and Health Administration. Laser\/Electrosurgery Plume. https:\/\/www.osha.gov\/laser-electrosurgery-plume (2021)."},{"key":"5701_CR7","doi-asserted-by":"publisher","first-page":"515","DOI":"10.3390\/ijerph17020515","volume":"17","author":"M Michaelis","year":"2020","unstructured":"Michaelis, M., Hofmann, F. M., Nienhaus, A. & Eickmann, U. Surgical Smoke\u2014Hazard Perceptions and Protective Measures in German Operating Rooms. Int. J. Environ. Res. Public Health 17, 515 (2020).","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"5701_CR8","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1001\/jamasurg.2019.2515","volume":"154","author":"IV Limchantra","year":"2019","unstructured":"Limchantra, I. V., Fong, Y. & Melstrom, K. A. Surgical smoke exposure in operating room personnel: A review. JAMA Surg. 154, 960\u2013967. https:\/\/doi.org\/10.1001\/jamasurg.2019.2515 (2019).","journal-title":"JAMA Surg."},{"key":"5701_CR9","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/1745-6673-3-31","volume":"3","author":"I Br\u00fcske-Hohlfeld","year":"2008","unstructured":"Br\u00fcske-Hohlfeld, I. et al. Surgical smoke and ultrafine particles. J. Occup. Med. Toxicol. 3, 31. https:\/\/doi.org\/10.1186\/1745-6673-3-31 (2008).","journal-title":"J. Occup. Med. Toxicol."},{"key":"5701_CR10","doi-asserted-by":"publisher","first-page":"3100","DOI":"10.1007\/s00464-013-2940-5","volume":"27","author":"N Mowbray","year":"2013","unstructured":"Mowbray, N., Ansell, J., Warren, N., Wall, P. & Torkington, J. Is surgical smoke harmful to theater staff? A systematic review. Surg. Endosc. 27, 3100\u20133107. https:\/\/doi.org\/10.1007\/s00464-013-2940-5 (2013).","journal-title":"Surg. Endosc."},{"key":"5701_CR11","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1016\/j.aorn.2007.07.005","volume":"86","author":"L Bigony","year":"2007","unstructured":"Bigony, L. Risks associated with exposure to surgical smoke plume: A review of the literature. AORN J. 86, 1013\u20131020. https:\/\/doi.org\/10.1016\/j.aorn.2007.07.005 (2007) (quiz 1021-1014).","journal-title":"AORN J."},{"key":"5701_CR12","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1111\/j.1748-5991.2010.01070.x","volume":"4","author":"K Ko","year":"2010","unstructured":"Ko, K., Mendeloff, J. & Gray, W. The role of inspection sequence in compliance with the US Occupational Safety and Health Administration\u2019s (OSHA) standards: Interpretations and implications. Regul. Gov. 4, 48\u201370. https:\/\/doi.org\/10.1111\/j.1748-5991.2010.01070.x (2010).","journal-title":"Regul. Gov."},{"key":"5701_CR13","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/S1015-9584(09)60403-6","volume":"32","author":"KM Fan","year":"2009","unstructured":"Fan, K. M., Chan, S. Y. & Chu, K. M. Surgical smoke. Asian J. Surg. 32, 253\u2013257. https:\/\/doi.org\/10.1016\/S1015-9584(09)60403-6 (2009).","journal-title":"Asian J. Surg."},{"key":"5701_CR14","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1080\/14733315.2019.1704539","volume":"20","author":"JJ Cheng","year":"2021","unstructured":"Cheng, J. J. et al. Experimental study on influence of personnel activity and surgical smoke on indoor environment inside clean operating room. Int. J. Vent. 20, 50\u201364. https:\/\/doi.org\/10.1080\/14733315.2019.1704539 (2021).","journal-title":"Int. J. Vent."},{"key":"5701_CR15","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1016\/s0886-3350(00)00813-0","volume":"27","author":"MJ Taravella","year":"2001","unstructured":"Taravella, M. J. et al. Respirable particles in the excimer laser plume. J. Cataract Refract. Surg. 27, 604\u2013607. https:\/\/doi.org\/10.1016\/s0886-3350(00)00813-0 (2001).","journal-title":"J. Cataract Refract. Surg."},{"key":"5701_CR16","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1007\/s00595-014-1085-z","volume":"45","author":"K Okoshi","year":"2015","unstructured":"Okoshi, K. et al. Health risks associated with exposure to surgical smoke for surgeons and operation room personnel. Surg. Today 45, 957\u2013965. https:\/\/doi.org\/10.1007\/s00595-014-1085-z (2015).","journal-title":"Surg. Today"},{"key":"5701_CR17","unstructured":"The International Agency for Research on Cancer. Agents Classified by the IARC Monographs, Volumes 1\u2013129, https:\/\/monographs.iarc.who.int\/agents-classified-by-the-iarc\/ (2021)."},{"key":"5701_CR18","doi-asserted-by":"publisher","first-page":"14096","DOI":"10.1038\/s41598-021-92859-9","volume":"11","author":"PC Cheng","year":"2021","unstructured":"Cheng, P. C., Wen, M. H., Hsu, W. L., Cheng, P. W. & Liao, L. J. A study to quantify surgical plume and survey the efficiency of different local exhaust ventilations. Sci. Rep. 11, 14096. https:\/\/doi.org\/10.1038\/s41598-021-92859-9 (2021).","journal-title":"Sci. Rep."},{"key":"5701_CR19","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.bjps.2012.02.012","volume":"65","author":"DS Hill","year":"2012","unstructured":"Hill, D. S., O\u2019Neill, J. K., Powell, R. J. & Oliver, D. W. Surgical smoke: A health hazard in the operating theatre: A study to quantify exposure and a survey of the use of smoke extractor systems in UK plastic surgery units. J. Plast. Reconstr. Aesthet. Surg. 65, 911\u2013916. https:\/\/doi.org\/10.1016\/j.bjps.2012.02.012 (2012).","journal-title":"J. Plast. Reconstr. Aesthet. Surg."},{"key":"5701_CR20","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1016\/j.jaad.2018.06.003","volume":"79","author":"C Georgesen","year":"2018","unstructured":"Georgesen, C. & Lipner, S. R. Surgical smoke: Risk assessment and mitigation strategies. J. Am. Acad. Dermatol. 79, 746\u2013755. https:\/\/doi.org\/10.1016\/j.jaad.2018.06.003 (2018).","journal-title":"J. Am. Acad. Dermatol."},{"key":"5701_CR21","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1136\/oemed-2019-106333","volume":"77","author":"A Fox-Lewis","year":"2020","unstructured":"Fox-Lewis, A., Allum, C., Vokes, D. & Roberts, S. Human papillomavirus and surgical smoke: A systematic review. Occup. Environ. Med. 77, 809\u2013817. https:\/\/doi.org\/10.1136\/oemed-2019-106333 (2020).","journal-title":"Occup. Environ. Med."},{"key":"5701_CR22","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1002\/bjs.11679","volume":"107","author":"NG Mowbray","year":"2020","unstructured":"Mowbray, N. G. et al. Safe management of surgical smoke in the age of COVID-19. Br. J. Surg. 107, 1406\u20131413. https:\/\/doi.org\/10.1002\/bjs.11679 (2020).","journal-title":"Br. J. Surg."},{"key":"5701_CR23","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1177\/0194599820917394","volume":"163","author":"DC O\u2019Brien","year":"2020","unstructured":"O\u2019Brien, D. C. et al. Surgical team exposure to cautery smoke and its mitigation during tonsillectomy. Otolaryngology 163, 508\u2013516. https:\/\/doi.org\/10.1177\/0194599820917394 (2020).","journal-title":"Otolaryngology"},{"key":"5701_CR24","unstructured":"Technology, H. In Online pdf (ed LLC HAL Technology) 1 (HAL Technology, LLC)."},{"key":"5701_CR25","first-page":"339","volume-title":"Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms","author":"Z Xu","year":"2013","unstructured":"Xu, Z. Classification of air cleanliness. In Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms 339\u2013376 (Springer, 2013)."},{"issue":"70","key":"5701_CR26","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1080\/10962247.2020.1717675","volume":"1995","author":"CI Li","year":"2020","unstructured":"Li, C. I., Pai, J. Y. & Chen, C. H. Characterization of smoke generated during the use of surgical knife in laparotomy surgeries. J. Air Waste Manag. Assoc. 1995(70), 324\u2013332. https:\/\/doi.org\/10.1080\/10962247.2020.1717675 (2020).","journal-title":"J. Air Waste Manag. Assoc."},{"key":"5701_CR27","unstructured":"UN World Population Prospects 2019. https:\/\/population.un.org\/wpp\/ (2019)."},{"key":"5701_CR28","unstructured":"The Occupational Safety and Health Administration. 1910.1048: Formaldehyde. https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.1048 (2021)."},{"key":"5701_CR29","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.aorn.2010.06.002","volume":"92","author":"K Ball","year":"2010","unstructured":"Ball, K. Compliance with surgical smoke evacuation guidelines: Implications for practice. AORN J. 92, 142\u2013149. https:\/\/doi.org\/10.1016\/j.aorn.2010.06.002 (2010).","journal-title":"AORN J."},{"key":"5701_CR30","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.aorn.2013.07.020","volume":"99","author":"L Schultz","year":"2014","unstructured":"Schultz, L. An analysis of surgical smoke plume components, capture, and evacuation. AORN J. 99, 289\u2013298. https:\/\/doi.org\/10.1016\/j.aorn.2013.07.020 (2014).","journal-title":"AORN J."},{"key":"5701_CR31","unstructured":"Liu, B. Y. H., Rubow, K. L. & Pui, D. Y. H. Performance of HEPA and ULPA filters. Proceedings, Annual Technical Meeting - Institute of Environmental Sciences 25\u201328 (1985)."},{"key":"5701_CR32","doi-asserted-by":"publisher","first-page":"4290","DOI":"10.1007\/s00464-018-6222-0","volume":"32","author":"SH Choi","year":"2018","unstructured":"Choi, S. H. et al. Activated carbon fiber filters could reduce the risk of surgical smoke exposure during laparoscopic surgery: Application of volatile organic compounds. Surg. Endosc. 32, 4290\u20134298. https:\/\/doi.org\/10.1007\/s00464-018-6222-0 (2018).","journal-title":"Surg. Endosc."},{"key":"5701_CR33","doi-asserted-by":"publisher","first-page":"137","DOI":"10.3390\/ijerph14020137","volume":"14","author":"F Romano","year":"2017","unstructured":"Romano, F., Gust\u00e9n, J., De Antonellis, S. & Joppolo, C. M. Electrosurgical smoke: Ultrafine particle measurements and work environment quality in different operating theatres. Int. J. Environ. Res. Public Health 14, 137 (2017).","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"5701_CR34","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.ajic.2007.07.008","volume":"36","author":"T Oberg","year":"2008","unstructured":"Oberg, T. & Brosseau, L. M. Surgical mask filter and fit performance. Am. J. Infect. Control 36, 276\u2013282. https:\/\/doi.org\/10.1016\/j.ajic.2007.07.008 (2008).","journal-title":"Am. J. Infect. Control"},{"key":"5701_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jhin.2005.01.014","volume":"62","author":"E Alp","year":"2006","unstructured":"Alp, E., Bijl, D., Bleichrodt, R. P., Hansson, B. & Voss, A. Surgical smoke and infection control. J. Hosp. Infect. 62, 1\u20135. https:\/\/doi.org\/10.1016\/j.jhin.2005.01.014 (2006).","journal-title":"J. Hosp. Infect."},{"key":"5701_CR36","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000001104","volume":"94","author":"T Kisch","year":"2015","unstructured":"Kisch, T. et al. Electrocautery devices with feedback mode and teflon-coated blades create less surgical smoke for a quality improvement in the operating theater. Medicine 94, e1104. https:\/\/doi.org\/10.1097\/md.0000000000001104 (2015).","journal-title":"Medicine"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-05701-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-05701-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-05701-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T16:31:16Z","timestamp":1669307476000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-05701-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,2]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["5701"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-05701-1","relation":{"has-review":[{"id-type":"doi","id":"10.32388\/A13O0G","asserted-by":"object"},{"id-type":"doi","id":"10.32388\/HCO65L","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,2]]},"assertion":[{"value":"10 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1719"}}