{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T20:23:47Z","timestamp":1777407827891,"version":"3.51.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T00:00:00Z","timestamp":1646956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T00:00:00Z","timestamp":1646956800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The studies for astigmatism prediction error at different diameters using optical biometry are scant. We investigated patients who underwent cataract surgery with monofocal, nontoric intraocular lens (IOL) from 2017 through 2019 in a medical center. Patients with prior refractive surgeries, corneal opacity, or surgical complications were excluded. Corneal astigmatism (CA) was measured using AL-Scan at 2.4- and 3.3-mm diameter zones and calculated using the Barrett toric calculator preoperatively and postoperatively. The mean absolute error and centroid prediction error for the two zones were computed using double-angle plots. In total, 101 eyes of 76 patients were analyzed. Mean patient age was 68.7\u2009\u00b1\u20099.3\u00a0years and mean preoperative CA power was 0.7\u2009\u00b1\u20090.5 D. The overall centroid prediction error\u00a0a 3.3 mm\u00a0(0.09\u2009\u00b1\u20090.58 D@25) was significantly lower than that at 2.4\u00a0mm (0.09\u2009\u00b1\u20090.68 D@87) on the X-axis (<jats:italic>P<\/jats:italic>\u2009=\u20090.003). The 3.3-mm measurement also had a lower centroid prediction error than the 2.4-mm did for eyes with against-the-rule (ATR) and oblique astigmatism (P\u2009=\u20090.024; 0.002 on X-axis, respectively). The 3.3-mm measurement provided a more accurate CA estimation than the 2.4-mm did, particularly for ATR astigmatism. Diameter zone and astigmatism type should be considered crucial to precise astigmatism calculation.<\/jats:p>","DOI":"10.1038\/s41598-022-08253-6","type":"journal-article","created":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T19:02:52Z","timestamp":1647025372000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Prediction of residual astigmatism in cataract surgery at different diameter zones using optical biometry measurement"],"prefix":"10.1038","volume":"12","author":[{"given":"Yin-Hsi","family":"Chang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christy","family":"Pu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken-Kuo","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiahn-Shing","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiun-Ho","family":"Hou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,3,11]]},"reference":[{"key":"8253_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2017.08.020","volume":"185","author":"RJ Olson","year":"2018","unstructured":"Olson, R. J. Cataract surgery from 1918 to the present and future-just imagine!. Am. J. Ophthalmol. 185, 10\u201313 (2018).","journal-title":"Am. J. Ophthalmol."},{"key":"8253_CR2","doi-asserted-by":"publisher","first-page":"2104","DOI":"10.1016\/j.ophtha.2010.07.033","volume":"117","author":"E Holland","year":"2010","unstructured":"Holland, E. et al. The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: A randomized, subject-masked, parallel-group, 1-year study. Ophthalmology 117, 2104\u20132111 (2010).","journal-title":"Ophthalmology"},{"key":"8253_CR3","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel, L. et al. Toric intraocular lenses in the correction of astigmatism during cataract surgery: A systematic review and meta-analysis. Ophthalmology 123, 275\u2013286 (2016).","journal-title":"Ophthalmology"},{"key":"8253_CR4","doi-asserted-by":"publisher","first-page":"e396","DOI":"10.1111\/aos.12584","volume":"93","author":"C Ostri","year":"2015","unstructured":"Ostri, C., Falck, L., Boberg-Ans, G. & Kessel, L. The need for toric intra-ocular lens implantation in public ophthalmology departments. Acta Ophthalmol. 93, e396\u2013e397 (2015).","journal-title":"Acta Ophthalmol."},{"key":"8253_CR5","doi-asserted-by":"publisher","first-page":"394","DOI":"10.3928\/1081597X-20140429-01","volume":"30","author":"N Hirnschall","year":"2014","unstructured":"Hirnschall, N., Hoffmann, P. C., Draschl, P., Maedel, S. & Findl, O. Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation. J. Refract. Surg. (Thorofare, NJ, 1995). 30, 394\u2013400 (2014).","journal-title":"J. Refract. Surg. (Thorofare, NJ, 1995)."},{"key":"8253_CR6","first-page":"26","volume":"2015","author":"H Lee","year":"2015","unstructured":"Lee, H., Kim, T.-I. & Kim, E. K. Corneal astigmatism analysis for toric intraocular lens implantation: Precise measurements for perfect correction. Curr. Opin. Ophthalmol. 2015, 26 (2015).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"8253_CR7","first-page":"112067211986606","volume":"2019","author":"YJ Ho","year":"2019","unstructured":"Ho, Y. J., Sun, C. C., Lee, J. S., Lin, K. K. & Hou, C. H. Comparison of using Galilei dual Scheimpflug analyzer G4 and Barrett formula in predicting low cylinder preoperatively for cataract surgeries. Eur. J. Ophthalmol. 2019, 1120672119866068 (2019).","journal-title":"Eur. J. Ophthalmol."},{"key":"8253_CR8","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/s12886-017-0550-z","volume":"17","author":"DY Park","year":"2017","unstructured":"Park, D. Y., Lim, D. H., Hwang, S., Hyun, J. & Chung, T. Y. Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation. BMC Ophthalmol. 17, 156 (2017).","journal-title":"BMC Ophthalmol."},{"key":"8253_CR9","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.2147\/OPTH.S213132","volume":"13","author":"FJ Ribeiro","year":"2019","unstructured":"Ribeiro, F. J., Ferreira, T. B., Relha, C., Esteves, C. & Gaspar, S. Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens. Clin. Ophthalmol. (Auckland, NZ) 13, 1649\u20131656 (2019).","journal-title":"Clin. Ophthalmol. (Auckland, NZ)"},{"key":"8253_CR10","doi-asserted-by":"publisher","first-page":"1561","DOI":"10.18240\/ijo.2019.10.07","volume":"12","author":"J Yang","year":"2019","unstructured":"Yang, J., Zhang, H., Yang, X. T., Tian, F. & Zhao, S. Z. Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods. Int. J. Ophthalmol. 12, 1561\u20131566 (2019).","journal-title":"Int. J. Ophthalmol."},{"key":"8253_CR11","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1016\/j.jcrs.2014.08.036","volume":"41","author":"A Abulafia","year":"2015","unstructured":"Abulafia, A. et al. Prediction of refractive outcomes with toric intraocular lens implantation. J. Cataract Refract. Surg. 41, 936\u2013944 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR12","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1038\/s41433-018-0063-x","volume":"32","author":"O Reitblat","year":"2018","unstructured":"Reitblat, O., Levy, A., Kleinmann, G. & Assia, E. I. Accuracy of intraocular lens power calculation using three optical biometry measurement devices: The OA-2000, Lenstar-LS900 and IOLMaster-500. Eye 32, 1244\u20131252 (2018).","journal-title":"Eye"},{"key":"8253_CR13","doi-asserted-by":"publisher","first-page":"114","DOI":"10.3928\/1081597X-20130117-06","volume":"29","author":"BW Lee","year":"2013","unstructured":"Lee, B. W. et al. Agreement between Pentacam and IOL master in patients undergoing toric IOL implantation. J. Refract. Surg. (Thorofare, NJ, 1995) 29, 114\u2013120 (2013).","journal-title":"J. Refract. Surg. (Thorofare, NJ, 1995)"},{"key":"8253_CR14","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1136\/bjophthalmol-2014-305150","volume":"98","author":"J Huang","year":"2014","unstructured":"Huang, J. et al. Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster. Br. J. Ophthalmol. 98, 1277\u20131281 (2014).","journal-title":"Br. J. Ophthalmol."},{"key":"8253_CR15","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1016\/j.jcrs.2013.09.015","volume":"40","author":"G Kaswin","year":"2014","unstructured":"Kaswin, G., Rousseau, A., Mgarrech, M., Barreau, E. & Labetoulle, M. Biometry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standard. J. Cataract Refract. Surg. 40, 593\u2013600 (2014).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR16","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.clae.2016.06.001","volume":"39","author":"E G\u00fcler","year":"2016","unstructured":"G\u00fcler, E., Kulak, A. E., Totan, Y., Yuvarlak, A. & Hep\u015fen, \u0130F. Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry. Contact Lens Anterior Eye J. Br. Contact Lens Assoc. 39, 336\u2013341 (2016).","journal-title":"Contact Lens Anterior Eye J. Br. Contact Lens Assoc."},{"key":"8253_CR17","doi-asserted-by":"publisher","first-page":"694","DOI":"10.3928\/1081597X-20160712-03","volume":"32","author":"KJ Hoffer","year":"2016","unstructured":"Hoffer, K. J. & Savini, G. Comparison of AL-Scan and IOLMaster 500 partial coherence interferometry optical biometers. J. Refract. Surg. (Thorofare, NJ, 1995) 32, 694\u2013698 (2016).","journal-title":"J. Refract. Surg. (Thorofare, NJ, 1995)"},{"key":"8253_CR18","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.2147\/OPTH.S137878","volume":"11","author":"HY Lin","year":"2017","unstructured":"Lin, H. Y. et al. Comparison of corneal power obtained from VERION image-guided surgery system and four other devices. Clin. Ophthalmol. (Auckland, NZ) 11, 1291\u20131299 (2017).","journal-title":"Clin. Ophthalmol. (Auckland, NZ)"},{"key":"8253_CR19","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/S0002-9394(98)00113-5","volume":"126","author":"W Drexler","year":"1998","unstructured":"Drexler, W. et al. Partial coherence interferometry: A novel approach to biometry in cataract surgery. Am. J. Ophthalmol. 126, 524\u2013534 (1998).","journal-title":"Am. J. Ophthalmol."},{"key":"8253_CR20","first-page":"37","volume":"2011","author":"W Hill","year":"2011","unstructured":"Hill, W. et al. Simulation of toric intraocular lens results: Manual keratometry versus dual-zone automated keratometry from an integrated biometer. J. Cataract Refract. Surg. 2011, 37 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR21","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1136\/bjo.2009.161729","volume":"94","author":"LP Cruysberg","year":"2010","unstructured":"Cruysberg, L. P. et al. Evaluation of the Lenstar LS 900 non-contact biometer. Br. J. Ophthalmol. 94, 106\u2013110 (2010).","journal-title":"Br. J. Ophthalmol."},{"key":"8253_CR22","doi-asserted-by":"publisher","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","volume":"128","author":"JX Kane","year":"2020","unstructured":"Kane, J. X. & Chang, D. F. Intraocular lens power formulas, biometry, and intraoperative aberrometry: A review. Ophthalmology 128, e94 (2020).","journal-title":"Ophthalmology"},{"key":"8253_CR23","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ajo.2013.01.029","volume":"156","author":"AZ Crawford","year":"2013","unstructured":"Crawford, A. Z., Patel, D. V. & McGhee, C. N. J. Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems. Am. J. Ophthalmol. 156, 53\u201360 (2013).","journal-title":"Am. J. Ophthalmol."},{"key":"8253_CR24","doi-asserted-by":"publisher","first-page":"9659481","DOI":"10.1155\/2017\/9659481","volume":"2017","author":"Y Qian","year":"2017","unstructured":"Qian, Y., Liu, Y., Zhou, X. & Naidu, R. K. Comparison of corneal power and astigmatism between simulated keratometry, true net power, and total corneal refractive power before and after SMILE surgery. J. Ophthalmol. 2017, 9659481 (2017).","journal-title":"J. Ophthalmol."},{"key":"8253_CR25","first-page":"4","volume":"2020","author":"Z Ashena","year":"2020","unstructured":"Ashena, Z., Maqsood, S., Ahmed, S. N. & Nanavaty, M. A. Effect of intraocular lens tilt and decentration on visual acuity, dysphotopsia and wavefront aberrations. Vision (Basel, Switzerland) 2020, 4 (2020).","journal-title":"Vision (Basel, Switzerland)"},{"key":"8253_CR26","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ajo.2016.04.011","volume":"167","author":"S Klijn","year":"2016","unstructured":"Klijn, S., Reus, N. J., van der Sommen, C. M. & Sicam, V. A. D. P. Accuracy of total corneal astigmatism measurements with a Scheimpflug Imager and a color light-emitting diode corneal topographer. Am. J. Ophthalmol. 167, 72\u201378 (2016).","journal-title":"Am. J. Ophthalmol."},{"key":"8253_CR27","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1016\/j.jcrs.2018.07.027","volume":"44","author":"A Abulafia","year":"2018","unstructured":"Abulafia, A., Koch, D. D., Holladay, J. T., Wang, L. & Hill, W. Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports. J. Cataract Refract. Surg. 44, 1169\u20131174 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR28","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.survophthal.2003.10.010","volume":"49","author":"NA Alpins","year":"2004","unstructured":"Alpins, N. A. & Goggin, M. Practical astigmatism analysis for refractive outcomes in cataract and refractive surgery. Surv. Ophthalmol. 49, 109\u2013122 (2004).","journal-title":"Surv. Ophthalmol."},{"key":"8253_CR29","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1016\/j.jcrs.2017.05.033","volume":"43","author":"A Kawahara","year":"2017","unstructured":"Kawahara, A. & Takayanagi, Y. Comparison of refractive and keratometric astigmatism after microincision cataract surgery. J. Cataract Refract. Surg. 43, 1050\u20131053 (2017).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR30","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/S0886-3350(00)00796-3","volume":"27","author":"JT Holladay","year":"2001","unstructured":"Holladay, J. T., Moran, J. R. & Kezirian, G. M. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J. Cataract Refract. Surg. 27, 61\u201379 (2001).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR31","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.jcrs.2013.09.020","volume":"40","author":"S Srivannaboon","year":"2014","unstructured":"Srivannaboon, S., Chirapapaisan, C., Chonpimai, P. & Koodkaew, S. Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometer. J. Cataract Refract. Surg. 40, 709\u2013715 (2014).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR32","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1167\/iovs.04-0558","volume":"46","author":"WR Davis","year":"2005","unstructured":"Davis, W. R., Raasch, T. W., Mitchell, G. L., Mutti, D. O. & Zadnik, K. Corneal asphericity and apical curvature in children: A cross-sectional and longitudinal evaluation. Invest. Ophthalmol. Vis. Sci. 46, 1899\u20131906 (2005).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"8253_CR33","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/ICO.0000000000002052","volume":"39","author":"J Dong","year":"2020","unstructured":"Dong, J. et al. Comparison of corneal power and corneal astigmatism of different diameter zones centered on the pupil and corneal apex using Scheimpflug tomography. Cornea 39, 77\u201383 (2020).","journal-title":"Cornea"},{"key":"8253_CR34","doi-asserted-by":"publisher","first-page":"3471","DOI":"10.1364\/BOE.7.003471","volume":"7","author":"S Manzanera","year":"2016","unstructured":"Manzanera, S. & Artal, P. Minimum change in spherical aberration that can be perceived. Biomed. Opt. Exp. 7, 3471\u20133477 (2016).","journal-title":"Biomed. Opt. Exp."},{"key":"8253_CR35","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1167\/iovs.14-15903","volume":"56","author":"G Savini","year":"2015","unstructured":"Savini, G. & N\u00e6ser, K. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest. Ophthalmol. Vis. Sci. 56, 827\u2013835 (2015).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"8253_CR36","first-page":"81","volume":"2004","author":"R Legras","year":"2004","unstructured":"Legras, R., Chateau, N. & Charman, W. N. Assessment of just-noticeable differences for refractive errors and spherical aberration using visual simulation. Optom. Vis. Sci. 2004, 81 (2004).","journal-title":"Optom. Vis. Sci."},{"key":"8253_CR37","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1111\/j.1444-0938.2010.00514.x","volume":"93","author":"P Rosales","year":"2010","unstructured":"Rosales, P., De Castro, A., Jim\u00e9nez-Alfaro, I. & Marcos, S. Intraocular lens alignment from purkinje and Scheimpflug imaging. Clin. Exp. Optom. 93, 400\u2013408 (2010).","journal-title":"Clin. Exp. Optom."},{"key":"8253_CR38","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.jcrs.2018.09.028","volume":"45","author":"JT Holladay","year":"2019","unstructured":"Holladay, J. T. & Pettit, G. Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5 mm temporal incision. J. Cataract Refract. Surg. 45, 272\u2013283 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"8253_CR39","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.jcrs.2017.10.037","volume":"44","author":"K Hayashi","year":"2018","unstructured":"Hayashi, K. et al. Changes in shape and astigmatism of total, anterior, and posterior cornea after long versus short clear corneal incision cataract surgery. J. Cataract Refract. Surg. 44, 39\u201349 (2018).","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-08253-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-08253-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-08253-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T23:50:29Z","timestamp":1669333829000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-08253-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,11]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["8253"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-08253-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,11]]},"assertion":[{"value":"8 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4305"}}