{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T20:43:25Z","timestamp":1773089005660,"version":"3.50.1"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,4,22]],"date-time":"2022-04-22T00:00:00Z","timestamp":1650585600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,4,22]],"date-time":"2022-04-22T00:00:00Z","timestamp":1650585600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Transcranial Doppler (TCD) is an easy, non-invasive, and real-time monitoring device for detecting right-to-left shunts (RLS). Nonetheless, it has limited benefits in patients with poor temporal windows. Therefore, we aimed to investigate whether the basilar artery (BA) window was as effective as the middle cerebral artery (MCA) in detecting RLS during TCD monitoring. Overall, we enrolled 344 patients with stroke, transient ischemic attack, headache, or dizziness. MCA and BA were monitored using a modified headset. To investigate the feasibility of the suboccipital window in detecting RLS, we instituted an evaluation tool with three tiers to evaluate microembolic signals (MESs) during TCD monitoring. Tier 1: TCD monitoring of the MCA (bilaterally) in the resting state, tier 2: TCD monitoring of the MCA (bilaterally) while performing the Valsalva maneuver, and tier 3: TCD monitoring of the index MCA and BA while performing the Valsalva maneuver. In tiers 2 and 3, a high agreement rate of 0.808 and 0.809 (p\u2009&lt;\u20090.001), respectively, on the weighted kappa index, and a high intra-class correlation coefficient of 0.982 and 0.986 (p\u2009&lt;\u20090.001), respectively, were observed on detecting MESs. Our data suggests that the BA window is as effective as the MCA window for detecting RLS on TCD.<\/jats:p>","DOI":"10.1038\/s41598-022-10645-7","type":"journal-article","created":{"date-parts":[[2022,4,22]],"date-time":"2022-04-22T11:03:30Z","timestamp":1650625410000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Simultaneous monitoring of the middle cerebral and basilar arteries to detect right-to-left shunts using transcranial Doppler by agitated saline administration"],"prefix":"10.1038","volume":"12","author":[{"given":"Min","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So Young","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji Man","family":"Hong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,4,22]]},"reference":[{"key":"10645_CR1","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.1056\/NEJMcp043981","volume":"353","author":"JR Kizer","year":"2005","unstructured":"Kizer, J. R. & Devereux, R. B. Clinical practice. Patent foramen ovale in young adults with unexplained stroke. N. Engl. J. Med. 353, 2361\u20132372. https:\/\/doi.org\/10.1056\/NEJMcp043981 (2005).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR2","doi-asserted-by":"publisher","first-page":"2065","DOI":"10.1056\/NEJMcp1503946","volume":"374","author":"JL Saver","year":"2016","unstructured":"Saver, J. L. Clinical practice. Cryptogenic stroke. N. Engl. J. Med. 374, 2065\u20132074. https:\/\/doi.org\/10.1056\/NEJMcp1503946 (2016).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR3","doi-asserted-by":"publisher","first-page":"1999","DOI":"10.1161\/circulationaha.107.757021","volume":"118","author":"SR Mess\u00e9","year":"2008","unstructured":"Mess\u00e9, S. R. & Kasner, S. E. Is closure recommended for patent foramen ovale and cryptogenic stroke? Patent foramen ovale in cryptogenic stroke: not to close. Circulation 118, 1999\u20132004. https:\/\/doi.org\/10.1161\/circulationaha.107.757021 (2008).","journal-title":"Circulation"},{"key":"10645_CR4","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1056\/NEJMoa1705915","volume":"377","author":"JL Mas","year":"2017","unstructured":"Mas, J. L. et al. Patent foramen ovale closure or anticoagulation vs antiplatelets after stroke. N. Engl. J. Med. 377, 1011\u20131021. https:\/\/doi.org\/10.1056\/NEJMoa1705915 (2017).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR5","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1056\/NEJMoa1610057","volume":"377","author":"JL Saver","year":"2017","unstructured":"Saver, J. L. et al. Long-term outcomes of patent foramen ovale closure or medical therapy after stroke. N. Engl. J. Med. 377, 1022\u20131032. https:\/\/doi.org\/10.1056\/NEJMoa1610057 (2017).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR6","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1056\/NEJMoa1707404","volume":"377","author":"L S\u00f8ndergaard","year":"2017","unstructured":"S\u00f8ndergaard, L. et al. Patent foramen ovale closure or antiplatelet therapy for cryptogenic stroke. N. Engl. J. Med. 377, 1033\u20131042. https:\/\/doi.org\/10.1056\/NEJMoa1707404 (2017).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR7","doi-asserted-by":"publisher","first-page":"2335","DOI":"10.1016\/j.jacc.2018.02.046","volume":"71","author":"PH Lee","year":"2018","unstructured":"Lee, P. H. et al. Cryptogenic stroke and high-risk patent foramen ovale: The DEFENSE-PFO trial. J. Am. Coll. Cardiol. 71, 2335\u20132342. https:\/\/doi.org\/10.1016\/j.jacc.2018.02.046 (2018).","journal-title":"J. Am. Coll. Cardiol."},{"key":"10645_CR8","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1136\/hrt.2004.052233","volume":"91","author":"FJ Pinto","year":"2005","unstructured":"Pinto, F. J. When and how to diagnose patent foramen ovale. Heart 91, 438\u2013440. https:\/\/doi.org\/10.1136\/hrt.2004.052233 (2005).","journal-title":"Heart"},{"key":"10645_CR9","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/0735-1097(91)90705-e","volume":"17","author":"AC Pearson","year":"1991","unstructured":"Pearson, A. C., Labovitz, A. J., Tatineni, S. & Gomez, C. R. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J. Am. Coll. Cardiol. 17, 66\u201372. https:\/\/doi.org\/10.1016\/0735-1097(91)90705-e (1991).","journal-title":"J. Am. Coll. Cardiol."},{"key":"10645_CR10","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/0002-9149(94)90407-3","volume":"74","author":"FP Job","year":"1994","unstructured":"Job, F. P. et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am. J. Cardiol. 74, 381\u2013384. https:\/\/doi.org\/10.1016\/0002-9149(94)90407-3 (1994).","journal-title":"Am. J. Cardiol."},{"key":"10645_CR11","doi-asserted-by":"publisher","first-page":"229","DOI":"10.5853\/jos.2015.17.3.229","volume":"17","author":"OY Bang","year":"2015","unstructured":"Bang, O. Y., Lee, M. J., Ryoo, S., Kim, S. J. & Kim, J. W. Patent foramen ovale and stroke-current status. J. Stroke 17, 229\u2013237. https:\/\/doi.org\/10.5853\/jos.2015.17.3.229 (2015).","journal-title":"J. Stroke"},{"key":"10645_CR12","doi-asserted-by":"publisher","DOI":"10.1161\/jaha.115.002975","volume":"5","author":"S Ryoo","year":"2016","unstructured":"Ryoo, S. et al. An approach to working up cases of embolic stroke of undetermined source. J. Am. Heart Assoc. 5, e002975. https:\/\/doi.org\/10.1161\/jaha.115.002975 (2016).","journal-title":"J. Am. Heart Assoc."},{"key":"10645_CR13","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.echo.2010.08.013","volume":"23","author":"JN Hilberath","year":"2010","unstructured":"Hilberath, J. N. et al. Safety of transesophageal echocardiography. J. Am. Soc. Echocardiogr. 23, 1115\u20131127. https:\/\/doi.org\/10.1016\/j.echo.2010.08.013 (2010).","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"10645_CR14","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1016\/0002-9149(91)90285-s","volume":"68","author":"JJ Nemec","year":"1991","unstructured":"Nemec, J. J. et al. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts. Am. J. Cardiol. 68, 1498\u20131502. https:\/\/doi.org\/10.1016\/0002-9149(91)90285-s (1991).","journal-title":"Am. J. Cardiol."},{"key":"10645_CR15","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1161\/01.str.24.7.1020","volume":"24","author":"M Di Tullio","year":"1993","unstructured":"Di Tullio, M. et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 24, 1020\u20131024. https:\/\/doi.org\/10.1161\/01.str.24.7.1020 (1993).","journal-title":"Stroke"},{"key":"10645_CR16","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1161\/01.str.25.6.1265","volume":"25","author":"M Jauss","year":"1994","unstructured":"Jauss, M., Kaps, M., Keberle, M., Haberbosch, W. & Dorndorf, W. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 25, 1265\u20131267. https:\/\/doi.org\/10.1161\/01.str.25.6.1265 (1994).","journal-title":"Stroke"},{"key":"10645_CR17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.jcmg.2009.12.012","volume":"3","author":"H Van","year":"2010","unstructured":"Van, H. et al. Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt. JACC Cardiovasc. Imaging 3, 343\u2013348. https:\/\/doi.org\/10.1016\/j.jcmg.2009.12.012 (2010).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"10645_CR18","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1161\/01.str.26.11.2061","volume":"26","author":"G Seidel","year":"1995","unstructured":"Seidel, G., Kaps, M. & Gerriets, T. Potential and limitations of transcranial color-coded sonography in stroke patients. Stroke 26, 2061\u20132066. https:\/\/doi.org\/10.1161\/01.str.26.11.2061 (1995).","journal-title":"Stroke"},{"key":"10645_CR19","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1161\/01.str.24.8.1192","volume":"24","author":"T Itoh","year":"1993","unstructured":"Itoh, T. et al. Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography. Stroke 24, 1192\u20131195. https:\/\/doi.org\/10.1161\/01.str.24.8.1192 (1993).","journal-title":"Stroke"},{"key":"10645_CR20","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1111\/j.1552-6569.2006.00064.x","volume":"16","author":"JH Kwon","year":"2006","unstructured":"Kwon, J. H., Kim, J. S., Kang, D. W., Bae, K. S. & Kwon, S. U. The thickness and texture of temporal bone in brain CT predict acoustic window failure of transcranial Doppler. J. Neuroimaging 16, 347\u2013352. https:\/\/doi.org\/10.1111\/j.1552-6569.2006.00064.x (2006).","journal-title":"J. Neuroimaging"},{"key":"10645_CR21","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1159\/000078503","volume":"23","author":"SL Bakker","year":"2004","unstructured":"Bakker, S. L. et al. Cerebral haemodynamics in the elderly: The Rotterdam study. Neuroepidemiology 23, 178\u2013184. https:\/\/doi.org\/10.1159\/000078503 (2004).","journal-title":"Neuroepidemiology"},{"key":"10645_CR22","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1016\/s0301-5629(97)00077-x","volume":"23","author":"M Marinoni","year":"1997","unstructured":"Marinoni, M., Ginanneschi, A., Forleo, P. & Amaducci, L. Technical limits in transcranial Doppler recording: Inadequate acoustic windows. Ultrasound Med. Biol. 23, 1275\u20131277. https:\/\/doi.org\/10.1016\/s0301-5629(97)00077-x (1997).","journal-title":"Ultrasound Med. Biol."},{"key":"10645_CR23","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1016\/j.ultrasmedbio.2007.11.022","volume":"34","author":"AD Wijnhoud","year":"2008","unstructured":"Wijnhoud, A. D., Franckena, M., van der Lugt, A., Koudstaal, P. J. & Dippel, E. D. Inadequate acoustical temporal bone window in patients with a transient ischemic attack or minor stroke: role of skull thickness and bone density. Ultrasound Med. Biol. 34, 923\u2013929. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2007.11.022 (2008).","journal-title":"Ultrasound Med. Biol."},{"key":"10645_CR24","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.1161\/01.str.21.11.1573","volume":"21","author":"JH Halsey","year":"1990","unstructured":"Halsey, J. H. Effect of emitted power on waveform intensity in transcranial Doppler. Stroke 21, 1573\u20131578. https:\/\/doi.org\/10.1161\/01.str.21.11.1573 (1990).","journal-title":"Stroke"},{"key":"10645_CR25","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1161\/01.str.18.6.1018","volume":"18","author":"P Grolimund","year":"1987","unstructured":"Grolimund, P., Seiler, R. W., Aaslid, R., Huber, P. & Zurbruegg, H. Evaluation of cerebrovascular disease by combined extracranial and transcranial Doppler sonography. Experience in 1039 patients. Stroke 18, 1018\u20131024. https:\/\/doi.org\/10.1161\/01.str.18.6.1018 (1987).","journal-title":"Stroke"},{"key":"10645_CR26","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1161\/01.str.30.7.1450","volume":"30","author":"AW Hoksbergen","year":"1999","unstructured":"Hoksbergen, A. W., Legemate, D. A., Ubbink, D. T. & Jacobs, M. J. Success rate of transcranial color-coded duplex ultrasonography in visualizing the basal cerebral arteries in vascular patients over 60 years of age. Stroke 30, 1450\u20131455. https:\/\/doi.org\/10.1161\/01.str.30.7.1450 (1999).","journal-title":"Stroke"},{"key":"10645_CR27","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1111\/j.1600-0404.1998.tb05961.x","volume":"97","author":"M Marinoni","year":"1998","unstructured":"Marinoni, M., Ginanneschi, A., Inzitari, D., Mugnai, S. & Amaducci, L. Sex-related differences in human cerebral hemodynamics. Acta Neurol. Scand. 97, 324\u2013327. https:\/\/doi.org\/10.1111\/j.1600-0404.1998.tb05961.x (1998).","journal-title":"Acta Neurol. Scand."},{"key":"10645_CR28","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1111\/j.1552-6569.2001.tb00064.x","volume":"11","author":"LM Lien","year":"2001","unstructured":"Lien, L. M. et al. Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute ischemic stroke. J. Neuroimaging 11, 363\u2013368. https:\/\/doi.org\/10.1111\/j.1552-6569.2001.tb00064.x (2001).","journal-title":"J. Neuroimaging"},{"key":"10645_CR29","doi-asserted-by":"publisher","first-page":"3707","DOI":"10.1161\/strokeaha.114.007453","volume":"45","author":"BJ Kim","year":"2014","unstructured":"Kim, B. J., Kim, N. Y., Kang, D. W., Kim, J. S. & Kwon, S. U. Provoked right-to-left shunt in patent foramen ovale associates with ischemic stroke in posterior circulation. Stroke 45, 3707\u20133710. https:\/\/doi.org\/10.1161\/strokeaha.114.007453 (2014).","journal-title":"Stroke"},{"key":"10645_CR30","doi-asserted-by":"publisher","first-page":"24932","DOI":"10.1038\/srep24932","volume":"6","author":"YZ Guo","year":"2016","unstructured":"Guo, Y. Z. et al. Comparison of vertebral artery and middle cerebral artery monitoring for right-to-left shunt detection by contrast-enhanced transcranial Doppler. Sci. Rep. 6, 24932. https:\/\/doi.org\/10.1038\/srep24932 (2016).","journal-title":"Sci. Rep."},{"key":"10645_CR31","doi-asserted-by":"publisher","first-page":"2254","DOI":"10.1161\/strokeaha.106.479485","volume":"38","author":"M Del Sette","year":"2007","unstructured":"Del Sette, M. et al. Diagnosis of right-to-left shunt with transcranial Doppler and vertebrobasilar recording. Stroke 38, 2254\u20132256. https:\/\/doi.org\/10.1161\/strokeaha.106.479485 (2007).","journal-title":"Stroke"},{"key":"10645_CR32","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1111\/jon.12311","volume":"26","author":"F Perren","year":"2016","unstructured":"Perren, F., Kremer, C., Iwanovski, P., Savva, E. & Landis, T. Detection of right-to-left cardiac shunt in the absence of transcranial acoustic bone. J. Neuroimaging 26, 269\u2013272. https:\/\/doi.org\/10.1111\/jon.12311 (2016).","journal-title":"J. Neuroimaging"},{"key":"10645_CR33","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1111\/j.1552-6569.2010.00518.x","volume":"22","author":"K Kobayashi","year":"2012","unstructured":"Kobayashi, K. et al. Right-to-left-shunt detected by c-TCD using the orbital window in comparison with temporal bone windows. J. Neuroimaging 22, 80\u201384. https:\/\/doi.org\/10.1111\/j.1552-6569.2010.00518.x (2012).","journal-title":"J. Neuroimaging"},{"key":"10645_CR34","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1159\/000016119","volume":"10","author":"M Jauss","year":"2000","unstructured":"Jauss, M. & Zanette, E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc. Dis. 10, 490\u2013496. https:\/\/doi.org\/10.1159\/000016119 (2000).","journal-title":"Cerebrovasc. Dis."},{"key":"10645_CR35","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1177\/1051228404268743","volume":"14","author":"MP Spencer","year":"2004","unstructured":"Spencer, M. P. et al. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J. Neuroimaging 14, 342\u2013349. https:\/\/doi.org\/10.1177\/1051228404268743 (2004).","journal-title":"J. Neuroimaging"},{"key":"10645_CR36","doi-asserted-by":"publisher","first-page":"e123","DOI":"10.1161\/strokeaha.107.498014","volume":"39","author":"MA Topcuoglu","year":"2008","unstructured":"Topcuoglu, M. A. Diagnosis of right-to-left shunts by transcranial doppler in patients with insufficient temporal bone window. Stroke 39, e123-124. https:\/\/doi.org\/10.1161\/strokeaha.107.498014 (2008) (author reply e125).","journal-title":"Stroke"},{"key":"10645_CR37","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1038\/jcbfm.2014.241","volume":"35","author":"L Zarrinkoob","year":"2015","unstructured":"Zarrinkoob, L. et al. Blood flow distribution in cerebral arteries. J. Cereb. Blood Flow Metab. 35, 648\u2013654. https:\/\/doi.org\/10.1038\/jcbfm.2014.241 (2015).","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"10645_CR38","doi-asserted-by":"publisher","first-page":"221","DOI":"10.7863\/jum.1991.10.4.221","volume":"10","author":"S Trattnig","year":"1991","unstructured":"Trattnig, S., Schwaighofer, B., H\u00fcbsch, P., Schwarz, M. & Kainberger, F. Color-coded Doppler sonography of vertebral arteries. J. Ultrasound Med. 10, 221\u2013226. https:\/\/doi.org\/10.7863\/jum.1991.10.4.221 (1991).","journal-title":"J. Ultrasound Med."},{"key":"10645_CR39","first-page":"1","volume":"21","author":"YM Chuang","year":"2012","unstructured":"Chuang, Y. M., Chan, L., Wu, H. M., Lee, S. P. & Chu, Y. T. The clinical relevance of vertebral artery hypoplasia. Acta Neurol. Taiwan 21, 1\u20137 (2012).","journal-title":"Acta Neurol. Taiwan"},{"key":"10645_CR40","doi-asserted-by":"publisher","first-page":"2201","DOI":"10.1161\/strokeaha.110.609875","volume":"42","author":"SJ Agustin","year":"2011","unstructured":"Agustin, S. J. et al. Effects of posture on right-to-left shunt detection by contrast transcranial doppler. Stroke 42, 2201\u20132205. https:\/\/doi.org\/10.1161\/strokeaha.110.609875 (2011).","journal-title":"Stroke"},{"key":"10645_CR41","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.ultrasmedbio.2014.09.005","volume":"41","author":"CT Wu","year":"2015","unstructured":"Wu, C. T. et al. Effects of patient position on right-to-left shunt detection by contrast transcranial Doppler. Ultrasound Med. Biol. 41, 654\u2013658. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2014.09.005 (2015).","journal-title":"Ultrasound Med. Biol."},{"key":"10645_CR42","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1056\/NEJMoa1211716","volume":"368","author":"B Meier","year":"2013","unstructured":"Meier, B. et al. Percutaneous closure of patent foramen ovale in cryptogenic embolism. N. Engl. J. Med. 368, 1083\u20131091. https:\/\/doi.org\/10.1056\/NEJMoa1211716 (2013).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR43","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1056\/NEJMoa1301440","volume":"368","author":"JD Carroll","year":"2013","unstructured":"Carroll, J. D. et al. Closure of patent foramen ovale versus medical therapy after cryptogenic stroke. N. Engl. J. Med. 368, 1092\u20131100. https:\/\/doi.org\/10.1056\/NEJMoa1301440 (2013).","journal-title":"N. Engl. J. Med."},{"key":"10645_CR44","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1056\/NEJMoa1009639","volume":"366","author":"AJ Furlan","year":"2012","unstructured":"Furlan, A. J. et al. Closure or medical therapy for cryptogenic stroke with patent foramen ovale. N. Engl. J. Med. 366, 991\u2013999. https:\/\/doi.org\/10.1056\/NEJMoa1009639 (2012).","journal-title":"N. Engl. J. Med."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-10645-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-10645-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-10645-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T20:47:51Z","timestamp":1669322871000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-10645-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,22]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["10645"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-10645-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-956948\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,22]]},"assertion":[{"value":"5 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6658"}}