{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T23:45:25Z","timestamp":1793317525345,"version":"4.5.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T00:00:00Z","timestamp":1651536000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T00:00:00Z","timestamp":1651536000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100018936","name":"Universit\u00e4tsklinikum Heidelberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018936","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Clinical photon-counting CT (PCCT) offers a spatial resolution of about 200\u00a0\u00b5m and might allow for acquisitions close to conventional dental CBCTs. In this study, the capabilities of this new system in comparison to dental CBCTs shall be evaluated. All 8 apical osteolysis identified in CBCT were identified by both readers in all three PCCT scan protocols. Mean visibility scores showed statistical significant differences for root canals(p\u2009=\u20090.0001), periodontal space(p\u2009=\u20090.0090), cortical(p\u2009=\u20090.0003) and spongious bone(p\u2009=\u20090.0293) in favor of high and medium dose PCCT acquisitions. Overall, both devices showed excellent image quality of all structures assessed. Interrater-agreement showed high values for all protocols in all structures. Bland\u2013Altman plots revealed a high concordance of both modalities with the reference  measurements. In vitro, ultra-high resolution PCCT can reliably identify different diagnostic entities and structures relevant for dental diagnostics similar to conventional dental CBCT with similar radiation dose. Acquisitions of five cadaveric heads were performed in an experimental CT-system containing an ultra-high resolution PC detector (0.25\u00a0mm pixel size in isocenter) as well as in a dental CBCT scanner. Acquisitions were performed using dose levels of 8.5\u00a0mGy, 38.0\u00a0mGy and 66.5\u00a0mGy (CTDI16cm) in case of PCCT and of 8.94\u00a0mGy (CTDI16cm) in case of CBCT. The quality of delineation of hard tissues, root-canals, periodontal-space as well as apical osteolysis was assessed by two readers. Mean visibility scores and interrater-agreement (overall agreement (%)) were calculated. Vertical bone loss (bl) and thickness (bt) of the buccal bone lamina of 15 lower incisors were measured and compared to reference measurements by ore microscopy and clinical probing.<\/jats:p>","DOI":"10.1038\/s41598-022-11281-x","type":"journal-article","created":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T06:02:54Z","timestamp":1651557774000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Dental imaging using an ultra-high resolution photon-counting CT system"],"prefix":"10.1038","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9945-7286","authenticated-orcid":false,"given":"Maurice","family":"Ruetters","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sinan","family":"Sen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Holger","family":"Gehrig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Bruckner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ti-Sun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Lux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heinz-Peter","family":"Schlemmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Heinze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joscha","family":"Maier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Kachelrie\u00df","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Sawall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,3]]},"reference":[{"issue":"7","key":"11281_CR1","doi-asserted-by":"publisher","first-page":"20170030","DOI":"10.1259\/dmfr.20170030","volume":"46","author":"C Nardi","year":"2017","unstructured":"Nardi, C. et al. Head and neck effective dose and quantitative assessment of image quality: A study to compare cone beam CT and multislice spiral CT. Dentomaxillofac. Radiol. 46(7), 20170030 (2017).","journal-title":"Dentomaxillofac. Radiol."},{"key":"11281_CR2","doi-asserted-by":"crossref","unstructured":"Schlemmer, H.P. The eye of the CT scanner: The story of learning to see the invisible or from the fluorescent screen to the photon-counting detector. Rofo. 2021.","DOI":"10.1055\/a-1308-2693"},{"issue":"2","key":"11281_CR3","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/RLI.0000000000000616","volume":"55","author":"L Klein","year":"2020","unstructured":"Klein, L. et al. Effects of detector sampling on noise reduction in clinical photon-counting whole-body computed tomography. Invest Radiol. 55(2), 111\u2013119 (2020).","journal-title":"Invest Radiol."},{"issue":"1","key":"11281_CR4","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1097\/RLI.0000000000000601","volume":"55","author":"MM Lell","year":"2020","unstructured":"Lell, M. M. & Kachelriess, M. Recent and upcoming technological developments in computed tomography: High speed, low dose, deep learning. Multienergy. Invest Radiol. 55(1), 8\u201319 (2020).","journal-title":"Multienergy. Invest Radiol."},{"key":"11281_CR5","first-page":"2","volume":"2","author":"K Rajendran","year":"2021","unstructured":"Rajendran, K. et al. Full field-of-view, high-resolution, photon-counting detector CT: Technical assessment and initial patient experience. Phys. Med. Biol. 2, 2 (2021).","journal-title":"Phys. Med. Biol."},{"issue":"3","key":"11281_CR6","doi-asserted-by":"publisher","first-page":"03TR01","DOI":"10.1088\/1361-6560\/abc5a5","volume":"66","author":"M Danielsson","year":"2021","unstructured":"Danielsson, M., Persson, M. & Sjolin, M. Photon-counting x-ray detectors for CT. Phys. Med. Biol. 66(3), 03TR01 (2021).","journal-title":"Phys. Med. Biol."},{"issue":"10","key":"11281_CR7","doi-asserted-by":"publisher","DOI":"10.1118\/1.4820371","volume":"40","author":"K Taguchi","year":"2013","unstructured":"Taguchi, K. & Iwanczyk, J. S. Vision 20\/20: Single photon counting x-ray detectors in medical imaging. Med Phys. 40(10), 100901 (2013).","journal-title":"Med Phys."},{"key":"11281_CR8","doi-asserted-by":"crossref","unstructured":"Wehrse, E., Klein, L., Rotkopf, L.T., et al. Photon-counting detectors in computed tomography: from quantum physics to clinical practice. Radiologe. 2021","DOI":"10.1007\/s00117-021-00812-8"},{"issue":"4","key":"11281_CR9","volume":"12","author":"DP Antony","year":"2020","unstructured":"Antony, D. P., Thomas, T. & Nivedhitha, M. S. Two-dimensional periapical, panoramic radiography versus three-dimensional cone-beam computed tomography in the detection of periapical lesion after endodontic treatment: A systematic review. Cureus. 12(4), e7736 (2020).","journal-title":"Cureus."},{"issue":"1","key":"11281_CR10","doi-asserted-by":"publisher","first-page":"53","DOI":"10.5624\/isd.2014.44.1.53","volume":"44","author":"JH Kang","year":"2014","unstructured":"Kang, J. H. et al. The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography. Imaging Sci. Dent. 44(1), 53\u201360 (2014).","journal-title":"Imaging Sci. Dent."},{"issue":"8","key":"11281_CR11","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1007\/s00276-013-1247-5","volume":"36","author":"GM Leite","year":"2014","unstructured":"Leite, G. M. et al. Anatomic variations and lesions of the mandibular canal detected by cone beam computed tomography. Surg. Radiol. Anat. 36(8), 795\u2013804 (2014).","journal-title":"Surg. Radiol. Anat."},{"issue":"2","key":"11281_CR12","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s12663-019-01193-1","volume":"19","author":"R Mohanty","year":"2020","unstructured":"Mohanty, R., Rout, P. & Singh, V. Preoperative anatomic evaluation of the relationship between inferior alveolar nerve canal and impacted mandibular third molar in a population of Bhubaneswar, Odisha, Using CBCT: A hospital-based study. J. Maxillofac. Oral Surg. 19(2), 257\u2013262 (2020).","journal-title":"J. Maxillofac. Oral Surg."},{"issue":"2","key":"11281_CR13","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.joen.2016.10.007","volume":"43","author":"JM Parker","year":"2017","unstructured":"Parker, J. M. et al. Cone-beam computed tomography uses in clinical endodontics: Observer variability in detecting periapical lesions. J. Endod. 43(2), 184\u2013187 (2017).","journal-title":"J. Endod."},{"issue":"1","key":"11281_CR14","first-page":"25","volume":"47","author":"C Walter","year":"2016","unstructured":"Walter, C. et al. Cone beam computed tomography (CBCT) for diagnosis and treatment planning in periodontology: A systematic review. Quintessence Int. 47(1), 25\u201337 (2016).","journal-title":"Quintessence Int."},{"issue":"9","key":"11281_CR15","doi-asserted-by":"publisher","first-page":"2943","DOI":"10.1007\/s00784-020-03326-0","volume":"24","author":"C Walter","year":"2020","unstructured":"Walter, C. et al. Cone beam computed tomography (CBCT) for diagnosis and treatment planning in periodontology: Systematic review update. Clin. Oral Investig. 24(9), 2943\u20132958 (2020).","journal-title":"Clin. Oral Investig."},{"issue":"3","key":"11281_CR16","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1111\/j.1600-0501.2011.02330.x","volume":"23","author":"C Walter","year":"2012","unstructured":"Walter, C. et al. Does three-dimensional imaging offer a financial benefit for treating maxillary molars with furcation involvement?\u2014A pilot clinical case series. Clin. Oral Implant Res. 23(3), 351\u2013358 (2012).","journal-title":"Clin. Oral Implant Res."},{"issue":"5","key":"11281_CR17","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1111\/j.1600-051X.2010.01556.x","volume":"37","author":"C Walter","year":"2010","unstructured":"Walter, C., Weiger, R. & Zitzmann, N. U. Accuracy of three-dimensional imaging in assessing maxillary molar furcation involvement. J. Clin. Periodontol. 37(5), 436\u2013441 (2010).","journal-title":"J. Clin. Periodontol."},{"key":"11281_CR18","unstructured":"Schiegnitz, E., Al-Nawas, B., Hoefert, S,, et al. S3-Leitlinie Antiresorptiva-assoziierte Kiefernekrosen. AWMF Registernummer: 007\u2013091. 2017."},{"key":"11281_CR19","doi-asserted-by":"crossref","unstructured":"Schulze, R., Deppe, H., Betz, W., et al. s2k-Leitlinie: Dentale digitale Volumentomographie. AWMF Registernummer: 083\u2013005. 2013.","DOI":"10.1055\/s-0032-1324998"},{"key":"11281_CR20","unstructured":"Kr\u00fcger, M., Hautmann, M., Bartella, A., et al. S2k-Leitlinie: Infizierte Osteoradionekrose (IORN) der Kiefer, AWMF-Registernummer: 007\/046. 2018."},{"key":"11281_CR21","unstructured":"Floh\u00e9, S., Ruchholtz, S., Eikermann, M., et al. Deutsche Gesellschaft f\u00fcr Unfallchirurgie e.V. (DGU): S3 \u2013 Leitlinie Polytrauma \/ Schwerverletzten-Behandlung, AWMF Register-Nr. 012\/019. 2016."},{"issue":"1","key":"11281_CR22","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1038\/s41746-020-00323-1","volume":"3","author":"N Rieke","year":"2020","unstructured":"Rieke, N. et al. The future of digital health with federated learning. NPJ Digit. Med. 3(1), 119 (2020).","journal-title":"NPJ Digit. Med."},{"issue":"8","key":"11281_CR23","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1902\/jop.1990.61.8.497","volume":"61","author":"J Osborn","year":"1990","unstructured":"Osborn, J. et al. Comparison of measurement variability using a standard and constant force periodontal probe. J. Periodontol. 61(8), 497\u2013503 (1990).","journal-title":"J. Periodontol."},{"issue":"3","key":"11281_CR24","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1308\/205016814812736619","volume":"3","author":"KNAA Shayeb","year":"2014","unstructured":"Shayeb, K. N. A. A., Turner, W. & Gillam, D. G. Periodontal probing: A review. Primary Dent. J. 3(3), 25\u201329 (2014).","journal-title":"Primary Dent. J."},{"key":"11281_CR25","doi-asserted-by":"crossref","unstructured":"Ruetters, M., Gehrig, H., Kronsteiner, D., et al. Ex-vivo imaging of buccal and oral periodontal bone with low-dose CBCT in porcine jaws. Dentomaxillofac. Radiol. 2021:accepted.","DOI":"10.1259\/dmfr.20210233"},{"key":"11281_CR26","doi-asserted-by":"crossref","unstructured":"Ruetters, M., Gehrig, H., Kronsteiner, D., et al. Ex-vivo assessment of the buccal and oral bone by CBCT J. Orofac. Orthop. \/ Fortschritte der Kieferorthop\u00e4die. 2021:accepted.","DOI":"10.1007\/s00056-021-00335-w"},{"issue":"1","key":"11281_CR27","doi-asserted-by":"publisher","first-page":"147","DOI":"10.5152\/dir.2020.19560","volume":"27","author":"E Atli","year":"2021","unstructured":"Atli, E. et al. Radiation doses from head, neck, chest and abdominal CT examinations: An institutional dose report. Diagn. Interv. Radiol. 27(1), 147\u2013151 (2021).","journal-title":"Diagn. Interv. Radiol."},{"key":"11281_CR28","doi-asserted-by":"publisher","first-page":"e61","DOI":"10.5114\/pjr.2019.82743","volume":"84","author":"D Khoramian","year":"2019","unstructured":"Khoramian, D., Sistani, S. & Firouzjah, R. A. Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations. Pol. J. Radiol. 84, e61\u2013e67 (2019).","journal-title":"Pol. J. Radiol."},{"key":"11281_CR29","unstructured":"Wolff K-D, Bootz F, Beck J, et al. Leitlinienprogramm Onkologie (Deutsche Krebsgesellschaft, Deutsche Krebshilfe, AWMF): S3-Leitlinie Diagnostik und Therapie des Mundh\u00f6hlenkarzinoms, Version 3.0, AWMF Registernummer: 007\/100OL https:\/\/www.leitlinienprogramm-onkologie.de\/leitlinien\/mundhoehlenkarzinom\/ 2021."},{"issue":"5","key":"11281_CR30","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1259\/dmfr\/30642039","volume":"40","author":"R Schulze","year":"2011","unstructured":"Schulze, R. et al. Artefacts in CBCT: A review. Dentomaxillofac. Radiol. 40(5), 265\u2013273 (2011).","journal-title":"Dentomaxillofac. Radiol."},{"issue":"3","key":"11281_CR31","doi-asserted-by":"publisher","first-page":"227","DOI":"10.5624\/isd.2020.50.3.227","volume":"50","author":"J Moratin","year":"2020","unstructured":"Moratin, J. et al. Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality. Imaging Sci. Dent. 50(3), 227\u2013236 (2020).","journal-title":"Imaging Sci. Dent."},{"issue":"1","key":"11281_CR32","doi-asserted-by":"publisher","first-page":"20190240","DOI":"10.1259\/dmfr.20190240","volume":"49","author":"GM Santaella","year":"2020","unstructured":"Santaella, G. M. et al. Impact of movement and motion-artefact correction on image quality and interpretability in CBCT units with aligned and lateral-offset detectors. Dentomaxillofac. Radiol. 49(1), 20190240 (2020).","journal-title":"Dentomaxillofac. Radiol."},{"issue":"5","key":"11281_CR33","doi-asserted-by":"publisher","first-page":"20180013","DOI":"10.1259\/dmfr.20180013","volume":"47","author":"R Spin-Neto","year":"2018","unstructured":"Spin-Neto, R. et al. An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability. Dentomaxillofac. Radiol. 47(5), 20180013 (2018).","journal-title":"Dentomaxillofac. Radiol."},{"key":"11281_CR34","first-page":"2","volume":"2","author":"CK McGarry","year":"2020","unstructured":"McGarry, C. K. et al. Tissue mimicking materials for imaging and therapy phantoms: A review. Phys. Med. Biol. 2, 2 (2020).","journal-title":"Phys. Med. Biol."},{"issue":"1","key":"11281_CR35","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1186\/s13244-020-00899-y","volume":"11","author":"G Paulo","year":"2020","unstructured":"Paulo, G. et al. Diagnostic Reference Levels based on clinical indications in computed tomography: A literature review. Insights Imaging. 11(1), 96 (2020).","journal-title":"Insights Imaging."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11281-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11281-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11281-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T21:09:44Z","timestamp":1669324184000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11281-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,3]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["11281"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-11281-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,3]]},"assertion":[{"value":"7 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"7125"}}