{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T18:40:21Z","timestamp":1795027221798,"version":"4.10.2"},"reference-count":63,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T00:00:00Z","timestamp":1652313600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T00:00:00Z","timestamp":1652313600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The increasing penetration levels of renewable distributed generation (RDG) into a power system have proven to bring both positive and negative impacts. The occurrence of under voltage at the far end of a conventional electrical distribution network (DN) may not raise concern anymore with RDGs integration into a power system. However, a penetration of RDGs into power system may cause problems such as voltage rise or over-voltage and reverse power flows at the Point of Common Coupling (PCC) between RDG and DN. This research paper presents the impact of voltage rise effect and reverse power flow constraint in power system with high concentration of RDG. The analysis is conducted on a sample DN, i.e., IEEE 13-bus test system, with RDG penetration by considering the most critical scenario such as low power demand in DN and a peak power injection by RDG. For studying the impact of voltage rise and reverse power flow, a mathematical model of a DN integrating RDG is developed. Furthermore, a controller incorporating an advance control-algorithm is proposed to be installed at PCC between DN and RDG to regulate the voltage rise effects and to mitigate the reverse power flow when operating at a worst critical scenario of minimum load and maximum generation from RDG. The proposed control strategy also mitigates the voltage\u2013current harmonic distortions, improves the power factor, and maintain the voltage stability at PCC. The simulations are carried out using MATLAB\/Simulink software. Finally, recommendations are provided for the power producers to counteract the effects of voltage rise at PCC. The study has demonstrated that, voltage at PCC can be sustained with a high concentration of RDG during a worst-case scenario without a reverse power flow and voltage rise beyond grid code limits.<\/jats:p>","DOI":"10.1038\/s41598-022-11765-w","type":"journal-article","created":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T05:03:46Z","timestamp":1652331826000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":46,"title":["Analysis of voltage rise phenomena in electrical power network with high concentration of renewable distributed generations"],"prefix":"10.1038","volume":"12","author":[{"given":"Ayodeji Stephen","family":"Akinyemi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kabeya","family":"Musasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Innocent E.","family":"Davidson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,12]]},"reference":[{"issue":"1","key":"11765_CR1","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1109\/JESTPE.2019.2908672","volume":"8","author":"MN Khan","year":"2020","unstructured":"Khan, M. N. et al. Transformer less inverter topologies for single-phase photo-voltaic systems: A comparative review. IEEE J. Emerg. Sel. Top. Power Electron. 8(1), 805\u2013835 (2020).","journal-title":"IEEE J. Emerg. Sel. Top. Power Electron."},{"issue":"3","key":"11765_CR2","doi-asserted-by":"publisher","first-page":"2058","DOI":"10.1109\/TIA.2021.3064911","volume":"57","author":"SM Reshikeshan","year":"2021","unstructured":"Reshikeshan, S. M., Matthiesen, S. L., Illindala, M. S., Renjit, A. A. & Roychowdhury, R. Autonomous voltage regulation by distributed PV inverters with minimal inter-node interference. IEEE Trans. Ind. Appl. 57(3), 2058\u20132066 (2021).","journal-title":"IEEE Trans. Ind. Appl."},{"issue":"4","key":"11765_CR3","first-page":"1","volume":"8","author":"FR Badal","year":"2019","unstructured":"Badal, F. R., Das, P., Sarker, S. K. & Das, S. K. A survey on control issues in renewable energy integration and microgrid. Prot. Control Mod. Power Syst. 8(4), 1\u201327 (2019).","journal-title":"Prot. Control Mod. Power Syst."},{"key":"11765_CR4","doi-asserted-by":"publisher","first-page":"60828","DOI":"10.1109\/ACCESS.2021.3073754","volume":"9","author":"E Memmel","year":"2021","unstructured":"Memmel, E. et al. Forecast of renewable curtailment in distribution grids considering uncertainties. IEEE Access 9, 60828\u201360840 (2021).","journal-title":"IEEE Access"},{"issue":"3","key":"11765_CR5","doi-asserted-by":"publisher","first-page":"3429","DOI":"10.1109\/TPWRS.2013.2256375","volume":"28","author":"P Jahangiri","year":"2013","unstructured":"Jahangiri, P. & Aliprantis, D. C. Distributed volt\/var control by PV inverters. IEEE Trans. Power Syst. 28(3), 3429\u20133439 (2013).","journal-title":"IEEE Trans. Power Syst."},{"issue":"6","key":"11765_CR6","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1109\/JPROC.2011.2116750","volume":"99","author":"K Turitsyn","year":"2011","unstructured":"Turitsyn, K., Sulc, P., Backhaus, S. & Chertkov, M. Options for control of reactive power by distributed photovoltaic generators. Proc. IEEE 99(6), 1063\u20131073 (2011).","journal-title":"Proc. IEEE"},{"issue":"1","key":"11765_CR7","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1109\/TPWRS.2012.2188819","volume":"28","author":"Y Kim","year":"2013","unstructured":"Kim, Y., Ahn, S., Hwang, P., Pyo, G. & Moon, S. Coordinated control of a DG and voltage control devices using a dynamic programming algorithm. IEEE Trans. Power Syst. 28(1), 42\u201351 (2013).","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"11765_CR8","first-page":"763","volume":"7","author":"J Dowell","year":"2016","unstructured":"Dowell, J. & Pinson, P. Very short-term probabilistic wind power forecasts by sparse vector auto-regression. IEEE Trans. Smart Grid 7(2), 763\u2013770 (2016).","journal-title":"IEEE Trans. Smart Grid"},{"issue":"1","key":"11765_CR9","first-page":"519","volume":"20","author":"MH Bollen","year":"2005","unstructured":"Bollen, M. H. & Sannino, A. Voltage control with inverter-based distributed generation. IEEE Trans. 20(1), 519\u2013520 (2005).","journal-title":"IEEE Trans."},{"issue":"2","key":"11765_CR10","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1109\/TPWRS.2008.919203","volume":"23","author":"PM Carvalho","year":"2008","unstructured":"Carvalho, P. M., Correia, P. F. & Ferreira, L. A. Distributed reactive power generation control for voltage rise mitigation in distribution networks. IEEE Trans. Power Syst. 23(2), 766\u2013772 (2008).","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"11765_CR11","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1109\/TSG.2012.2196528","volume":"3","author":"S Deshmukh","year":"2012","unstructured":"Deshmukh, S., Pahwa, A. & Natarajan, B. Voltage\/VAR control in distribution networks via reactive power injection through distributed generators. IEEE Trans. Smart Grid. 3(3), 1226\u20131234 (2012).","journal-title":"IEEE Trans. Smart Grid."},{"issue":"3","key":"11765_CR12","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1109\/TPWRS.2012.2186470","volume":"27","author":"T Sansawatt","year":"2012","unstructured":"Sansawatt, T., Ochoa, L. F. & Har, G. P. Smart decentralized control of DG for voltage and thermal constraint management. IEEE Trans. Power Syst. 27(3), 1637\u20131645 (2012).","journal-title":"IEEE Trans. Power Syst."},{"key":"11765_CR13","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.epsr.2015.05.018","volume":"127","author":"MZ Degefa","year":"2015","unstructured":"Degefa, M. Z., Lehtonen, M., Millar, R. J., Alah\u00e4iv\u00e4l\u00e4, A. & Sa, E. Optimal voltage control strategies for day-ahead active distribution network operation. Electr. Power Syst. Res. 127, 41\u201352 (2015).","journal-title":"Electr. Power Syst. Res."},{"issue":"3","key":"11765_CR14","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1109\/TSTE.2021.3053559","volume":"12","author":"H Qiu","year":"2021","unstructured":"Qiu, H., Gu, W. & You, F. Bilayer distributed optimization for robust microgrid dispatch with coupled individual-collective profits. IEEE Trans. Sustain. Energy 12(3), 1525\u20131538 (2021).","journal-title":"IEEE Trans. Sustain. Energy"},{"key":"11765_CR15","first-page":"4432","volume":"8","author":"RM Elavarasan","year":"2020","unstructured":"Elavarasan, R. M. et al. A comprehensive review on renewable energy development, challenges, and policies of leading Indian states with an international perspective. IEEE Access 8, 4432\u201374457 (2020).","journal-title":"IEEE Access"},{"key":"11765_CR16","doi-asserted-by":"publisher","first-page":"13344","DOI":"10.1109\/ACCESS.2021.3051843","volume":"9","author":"H Gao","year":"2021","unstructured":"Gao, H., Chen, J., Diao, J. & Zhang, J. A HEM-based sensitivity analysis method for fast voltage stability assessment in distribution power network. IEEE Access 9, 13344\u201313353 (2021).","journal-title":"IEEE Access"},{"key":"11765_CR17","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1109\/OJPEL.2021.3056627","volume":"2","author":"S Xu","year":"2021","unstructured":"Xu, S., Xue, Y. & Chang, L. Review of power system support functions for inverter-based distributed energy resources- standards, control algorithms, and trends. IEEE Open J. Power Electron. 2, 644\u20131314 (2021).","journal-title":"IEEE Open J. Power Electron."},{"issue":"9","key":"11765_CR18","first-page":"1","volume":"29","author":"P Wang","year":"2021","unstructured":"Wang, P. et al. Equivalent model of multi-type distributed generators under faults with fast-iterative calculation method based on improved PSO algorithm. Prot. Control Mod. Power Syst. 29(9), 1\u201312 (2021).","journal-title":"Prot. Control Mod. Power Syst."},{"key":"11765_CR19","doi-asserted-by":"crossref","unstructured":"Singh, N. K., Elrayyah, A. & Wanik, M.Z. Analysis of voltage rise and optimal PV curtailment strategy for its mitigation. In IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), 610\u2013614 (2020).","DOI":"10.1109\/ISGT-Europe47291.2020.9248971"},{"key":"11765_CR20","doi-asserted-by":"crossref","unstructured":"Matkar, G., Dheer, D. K., Vijay, A. S. & Suryanarayana D. A simple mathematical approach to assess the impact of solar PV penetration on voltage profile of distribution network. In National Power Electronics Conference (NPEC), 209\u2013214. (Pune, 2017).","DOI":"10.1109\/NPEC.2017.8310460"},{"key":"11765_CR21","doi-asserted-by":"crossref","unstructured":"Dhaval, Y. R. & Saurabh, N. P. Phase shifting strategy for mitigation of local voltage rise in highly PV penetrated distribution network. In IEEE International Conference on Power Systems (ICPS), 1\u20136 (Kharagpur, 2021).","DOI":"10.1109\/ICPS52420.2021.9670088"},{"key":"11765_CR22","doi-asserted-by":"crossref","unstructured":"Zad, B. B., Lobry, J., Vall\u00e9e, F. & Durieux, O. Improvement of on-load tap changer performance in voltage regulation of MV distribution. In International Conference and Exhibition on Electricity Distribution (CIRED), 0496 (Stockholm, 2013).","DOI":"10.1049\/cp.2013.0762"},{"issue":"9","key":"11765_CR23","first-page":"1","volume":"6","author":"S Keun","year":"2013","unstructured":"Keun, S. et al. General and simple decision method for DG penetration level in view of voltage regulation at distribution. Energies 6(9), 1\u201313 (2013).","journal-title":"Energies"},{"key":"11765_CR24","doi-asserted-by":"crossref","unstructured":"Nikolaos, E., Thomas, W., Carlos, G., Tom De, R. & Johan, D. Coordinated voltage control scheme for Flemish LV distribution grids utilizing OLTC transformers and D-STATCOM's. In IET International Conference on Developments in Power System Protection (DPSP), 1\u20136 (Copenhagen, 2014).","DOI":"10.1049\/cp.2014.0041"},{"issue":"10","key":"11765_CR25","first-page":"1","volume":"8","author":"RM Luis","year":"2020","unstructured":"Luis, R. M. et al. Linearly decoupled control of a dynamic voltage restorer without energy storage. Energies 8(10), 1\u201318 (2020).","journal-title":"Energies"},{"issue":"23","key":"11765_CR26","first-page":"1","volume":"12","author":"CT Igor","year":"2019","unstructured":"Igor, C. T., Gustavo, F. N. & Chigueru, T. Theoretical and experimental study to determine voltage violation, reverse electric current and losses in prosumers connected to low-voltage power grid. Energies 12(23), 1\u201320 (2019).","journal-title":"Energies"},{"issue":"8","key":"11765_CR27","first-page":"1","volume":"3","author":"D Edoardo","year":"2007","unstructured":"Edoardo, D., Marco, P., Ferdinanda, P. & Antonello, M. A coordinated voltage control for overvoltage mitigation in LV distribution grids. Energies 3(8), 1\u201320 (2007).","journal-title":"Energies"},{"issue":"12","key":"11765_CR28","first-page":"1","volume":"10","author":"A Dilini","year":"2021","unstructured":"Dilini, A., Jagadeesh, P., Shangari, K. R. & Reyasudin, B. K. Performance evaluation of solar PV inverter controls for overvoltage mitigation in MV distribution networks. Energies 10(12), 1\u201314 (2021).","journal-title":"Energies"},{"key":"11765_CR29","doi-asserted-by":"publisher","first-page":"10857","DOI":"10.1109\/ACCESS.2020.2964896","volume":"8","author":"DA Shakir","year":"2020","unstructured":"Shakir, D. A., Fahad, S. M., Shafiullah, M., Fahad, A. A. & Ibrahim, M. E. Grid integration challenges of wind energy: A review. IEEE Access 8, 10857\u201310878 (2020).","journal-title":"IEEE Access"},{"key":"11765_CR30","doi-asserted-by":"publisher","first-page":"99299","DOI":"10.1109\/ACCESS.2019.2930413","volume":"7","author":"OP Mahela","year":"2019","unstructured":"Mahela, O. P., Gupta, N., Khosravy, M. & Patel, N. Comprehensive overview of low voltage ride through methods of grid integrated wind generator. IEEE Access 7, 99299\u201399326 (2019).","journal-title":"IEEE Access"},{"issue":"3","key":"11765_CR31","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1109\/TPWRD.2015.2499701","volume":"31","author":"U Vargas","year":"2016","unstructured":"Vargas, U. & Ramirez, A. Extended harmonic domain model of a wind turbine generator for harmonic transient analysis. IEEE Trans. Power Deliv. 31(3), 1360\u20131368 (2016).","journal-title":"IEEE Trans. Power Deliv."},{"key":"11765_CR32","volume-title":"Power System Analysis & Design, SI Version","author":"JD Glover","year":"2012","unstructured":"Glover, J. D., Sarma, M. S. & Overbye, T. Power System Analysis & Design, SI Version (Cengage Learning, 2012)."},{"issue":"7","key":"11765_CR33","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1016\/j.epsr.2007.10.005","volume":"78","author":"A El-Sattar","year":"2008","unstructured":"El-Sattar, A., Saad, N. & El-Dein, M. S. Dynamic response of doubly fed induction generator variable speed wind turbine under fault. Electr. Power Syst. Res. 78(7), 1240\u20131246 (2008).","journal-title":"Electr. Power Syst. Res."},{"issue":"11","key":"11765_CR34","doi-asserted-by":"publisher","first-page":"8514","DOI":"10.1109\/TPEL.2016.2645791","volume":"32","author":"D Zhu","year":"2017","unstructured":"Zhu, D. et al. Inductance emulating control for DFIG-based wind turbine to ride-through grid faults. IEEE Trans. Power Electron. 32(11), 8514\u20138525 (2017).","journal-title":"IEEE Trans. Power Electron."},{"issue":"8","key":"11765_CR35","doi-asserted-by":"publisher","first-page":"1114","DOI":"10.1049\/iet-rpg.2015.0586","volume":"10","author":"J Mohammadi","year":"2016","unstructured":"Mohammadi, J., Vaez-Zadeh, S., Afsharnia, S. & Farhangi, S. Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults. IET Renew. Power Gener. 10(8), 1114\u20131122 (2016).","journal-title":"IET Renew. Power Gener."},{"issue":"1","key":"11765_CR36","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1109\/TIA.2016.2611665","volume":"53","author":"SB Naderi","year":"2017","unstructured":"Naderi, S. B., Negnevitsky, M., Jalilian, A., Hagh, M. T. & Muttaqi, K. M. Optimum resistive type fault current limiter: An efficient solution to achieve maximum fault ride-through capability of fixed-speed wind turbines during symmetrical and asymmetrical grid faults. IEEE Trans. Ind. Appl. 53(1), 538\u2013548 (2017).","journal-title":"IEEE Trans. Ind. Appl."},{"issue":"1","key":"11765_CR37","doi-asserted-by":"publisher","first-page":"013304","DOI":"10.1063\/1.4976141","volume":"9","author":"MY Worku","year":"2017","unstructured":"Worku, M. Y., Abido, M. A. & Iravani, R. PMSG based wind system for real-time maximum power generation and low voltage ride through. J. Renew. Sustain. Energy 9(1), 013304 (2017).","journal-title":"J. Renew. Sustain. Energy"},{"issue":"5","key":"11765_CR38","doi-asserted-by":"publisher","first-page":"4558","DOI":"10.1109\/TIA.2021.3089116","volume":"57","author":"J Amin","year":"2021","unstructured":"Amin, J., Kashem, M. M. & Danny, S. A novel voltage clamping-based overvoltage protection strategy to avoid spurious trip of inverter-based resources and eliminate the risk of wildfire following the REFCL operation in compensated networks. IEEE Trans. Ind. Appl. 57(5), 4558\u20134568 (2021).","journal-title":"IEEE Trans. Ind. Appl."},{"key":"11765_CR39","volume-title":"Grid Connection Code for Renewable Power Plants (RPPs) Connected to the Electricity Transmission System (TS) or the Distribution System (DS) in South Africa","author":"NERSA","year":"2014","unstructured":"NERSA. Grid Connection Code for Renewable Power Plants (RPPs) Connected to the Electricity Transmission System (TS) or the Distribution System (DS) in South Africa (RSA Grid Code Secretariat, 2014)."},{"key":"11765_CR40","doi-asserted-by":"crossref","unstructured":"Kersting, W. H. Radial distribution test feeders. In Power Engineering Society Winter Meeting. 2, 908\u2013912 (IEE Power Engineering Society Winter Meeting, 2001).","DOI":"10.1109\/PESW.2001.916993"},{"issue":"3","key":"11765_CR41","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1109\/59.119237","volume":"6","author":"WH Kersting","year":"1991","unstructured":"Kersting, W. H. Radial distribution test feeders. IEEE Trans. Power Syst. 6(3), 975\u2013985 (1991).","journal-title":"IEEE Trans. Power Syst."},{"key":"11765_CR42","volume-title":"EEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems","author":"IEEE Standard","year":"2014","unstructured":"IEEE Standard. EEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems (IEEE Standard, 2014)."},{"issue":"6","key":"11765_CR43","first-page":"1","volume":"26","author":"N Karmakar","year":"2021","unstructured":"Karmakar, N. & Bhattacharyya, B. Hybrid intelligence approach for multi-load level reactive power planning using VAR compensator in power transmission network. Prot. Control Mod. Power Syst. 26(6), 1\u201317 (2021).","journal-title":"Prot. Control Mod. Power Syst."},{"key":"11765_CR44","doi-asserted-by":"crossref","unstructured":"Hu, H. et al. Grid impedance impact analysis of the weak grid-tied VSC. In IEEE Green Technologies Conference (Greentech) (Denver, 2021).","DOI":"10.1109\/GreenTech48523.2021.00091"},{"key":"11765_CR45","volume-title":"Electric Power Systems Quality","author":"RC Dugan","year":"2002","unstructured":"Dugan, R. C., McGranaghan, M. F., Santosa, S. & Beaty, H. W. Electric Power Systems Quality (McGraw-Hill, 2002)."},{"key":"11765_CR46","doi-asserted-by":"crossref","unstructured":"Blazic, B. & Papic, I. Voltage profile support in distribution networks\u2014Influence of the network R\/X ratio. In International Power Electronics and Motion Control Conference (Poznan, 2008).","DOI":"10.1109\/EPEPEMC.2008.4635641"},{"key":"11765_CR47","unstructured":"Akinyemi, A. S. & Awodele, K. Voltage profiles improvement with wind energy converter connected to a distribution network. Southern African University Power Engineering Conference (SAUPEC) (Johannesburg, 2015)."},{"issue":"3","key":"11765_CR48","doi-asserted-by":"publisher","first-page":"2212","DOI":"10.1109\/TIA.2021.3064910","volume":"57","author":"S Mahdavi","year":"2021","unstructured":"Mahdavi, S., Panamtash, H., Dimitrovski, A. & Zhou, Q. Predictive coordinated and cooperative voltage control for systems with high penetration of PV. IEEE Trans. Ind. Appl. 57(3), 2212\u20132222 (2021).","journal-title":"IEEE Trans. Ind. Appl."},{"key":"11765_CR49","unstructured":"Sree, L. K., & Vijaya, K. M. Dynamic voltage stability enhancement of a wind farm connected to grid using facts\u2014A comparison. In International Conference on Circuits and Systems in Digital Enterprise Technology (ICCSDET), 1\u20135 (Kottayam, 2020)."},{"key":"11765_CR50","doi-asserted-by":"crossref","unstructured":"Tian, C., Chenghao, L., Gao, Z., Rao, Y., Cui, W. & Xueqing, P. Study on different modes of reactive power compensation and reactive power coordinated control for wind farm. In IEEE Industrial and Commercial Power System, 340\u2013345 (2020).","DOI":"10.1109\/ICPSAsia48933.2020.9208467"},{"key":"11765_CR51","doi-asserted-by":"crossref","unstructured":"Dorile, P. O., Jagessar, D. R., Guardado, L., Jagessar, S. S. & McCann, R. A. Power system stabilization of a grid highly penetrated from a variable-speed wind based farm through robust means of STATCOM and SSSC. In International Conference on Engineering of Modern Electric Systems (EMES) (Oradea, 2021).","DOI":"10.1109\/EMES52337.2021.9484110"},{"key":"11765_CR52","doi-asserted-by":"crossref","unstructured":"Dash, R. L., Tripathy, S., Mohanty, B. & Hota, P. K. Power quality improvement of grid connected wind system with STATCOM. In International Conference on Power Electronics and Energy (ICPEE) (Bhubaneswar, 2021).","DOI":"10.1109\/ICPEE50452.2021.9358720"},{"issue":"4","key":"11765_CR53","first-page":"1293","volume":"4","author":"K Arrik","year":"2013","unstructured":"Arrik, K. & Sirdeep, S. Integration of wind farm in power system using STATCOM. Int. J. Sci. Eng. Res. 4(4), 1293\u20131299 (2013).","journal-title":"Int. J. Sci. Eng. Res."},{"issue":"4","key":"11765_CR54","doi-asserted-by":"publisher","first-page":"4253","DOI":"10.1109\/TIA.2021.3079383","volume":"57","author":"S Hasan","year":"2021","unstructured":"Hasan, S. & AgarwaI, V. An unconstrained voltage support scheme for distributed generation connected to resistive-inductive grid under unbalanced conditions. IEEE Trans. Ind. Appl. 57(4), 4253\u20134262 (2021).","journal-title":"IEEE Trans. Ind. Appl."},{"key":"11765_CR55","first-page":"1447","volume":"2","author":"C Canizares","year":"2000","unstructured":"Canizares, C. Power flow and transient stability models of FACTS controllers for voltage and angle stability studies. IEEE Power Eng. Soc. Winter Meet. 2, 1447\u20131454 (2000).","journal-title":"IEEE Power Eng. Soc. Winter Meet."},{"issue":"2","key":"11765_CR56","first-page":"722","volume":"3","author":"MA Alinezhad","year":"2009","unstructured":"Alinezhad, M. A. & Kamarposhti, M. Comparison of SVC and STATCOM in static voltage stability margin enhancement. Int. Sci. Index 3(2), 722\u2013727 (2009).","journal-title":"Int. Sci. Index"},{"issue":"5","key":"11765_CR57","doi-asserted-by":"publisher","first-page":"4562","DOI":"10.1109\/TPWRS.2021.3056565","volume":"36","author":"G Lee","year":"2021","unstructured":"Lee, G., Hwang, P. & Moon, S. Reactive power control of hybrid multi-terminal HVDC systems considering the interaction between the AC network and multiple LCCs. IEEE Trans. Power Syst. 36(5), 4562\u20134574 (2021).","journal-title":"IEEE Trans. Power Syst."},{"key":"11765_CR58","doi-asserted-by":"publisher","DOI":"10.1002\/9780470551578","volume-title":"Voltage Converters in Power System","author":"A Yazdani","year":"2010","unstructured":"Yazdani, A. & Iravani, R. Voltage Converters in Power System (Wiley, 2010)."},{"key":"11765_CR59","doi-asserted-by":"publisher","first-page":"34119","DOI":"10.1109\/ACCESS.2021.3058081","volume":"9","author":"MI Mosaad","year":"2021","unstructured":"Mosaad, M. I., Ramadan, H. S., Aljohani, M., El-Naggar, M. F. & Ghoneim, S. S. Near-optimal PI controllers of STATCOM for efficient hybrid renewable power system. IEEE Access 9, 34119\u201334130 (2021).","journal-title":"IEEE Access"},{"key":"11765_CR60","doi-asserted-by":"publisher","first-page":"50138","DOI":"10.1109\/ACCESS.2021.3069293","volume":"9","author":"X Zhou","year":"2021","unstructured":"Zhou, X. et al. Control strategy research of D-STATCOM using active disturbance rejection control based on total disturbance error compensation. IEEE Access 9, 50138\u201350150 (2021).","journal-title":"IEEE Access"},{"issue":"6","key":"11765_CR61","first-page":"1","volume":"23","author":"OJ Oghorada","year":"2021","unstructured":"Oghorada, O. J., Zhang, L., Han, H., Esan, A. B. & Mao, M. Inter-cluster voltage balancing control of a delta connected modular multilevel cascaded converter under unbalanced grid voltage. Protect. Control Mod. Power Syst. 23(6), 1\u201311 (2021).","journal-title":"Protect. Control Mod. Power Syst."},{"key":"11765_CR62","doi-asserted-by":"publisher","first-page":"60531","DOI":"10.1109\/ACCESS.2021.3071815","volume":"9","author":"S Ranjan","year":"2021","unstructured":"Ranjan, S. et al. Maiden voltage control analysis of hybrid power system with dynamic voltage restorer. IEEE Access 9, 60531\u201360542 (2021).","journal-title":"IEEE Access"},{"key":"11765_CR63","doi-asserted-by":"publisher","first-page":"145840","DOI":"10.1109\/ACCESS.2021.3119745","volume":"9","author":"JH Woo","year":"2021","unstructured":"Woo, J. H., Wu, L., Lee, S. M., Park, J. & Roh, J. H. D-STATCOM d-q axis current reference control applying DDPG algorithm in the distribution system. IEEE Access 9, 145840\u2013214585 (2021).","journal-title":"IEEE Access"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11765-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11765-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11765-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,24]],"date-time":"2024-09-24T10:10:55Z","timestamp":1727172655000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-11765-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,12]]},"references-count":63,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["11765"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-11765-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,12]]},"assertion":[{"value":"29 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"7815"}}