{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T14:19:25Z","timestamp":1773584365238,"version":"3.50.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T00:00:00Z","timestamp":1660780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T00:00:00Z","timestamp":1660780800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To report the visual and refractive outcomes of new aspheric hydrophobic acrylic monofocal intraocular lens (IOL). Retrospective case series. This study included eyes of patients who underwent routine cataract surgery for uncomplicated age-related cataract with implantation of a Aktis SP (NS-60YG; Nidek Co. Ltd., Japan) IOL and attended regular follow ups at 1\u00a0week, 1\u00a0month, 3\u00a0months, and 12\u00a0months. At each post-operative visit, ophthalmological evaluation included measurement Uncorrected (UCVA) and Best corrected visual acuity (BCVA), contrast sensitivity, posterior capsular opacification (PCO), optical aberrations, analysis of point spread function (PSF) and modulation transfer function (MTF). The study included 2102 eyes of 1358 patients aged 45 to 75\u00a0years (mean age 62.6\u00a0years\u2009\u00b1\u20095.6 SD). The mean preoperative BCVA was 0.56\u2009\u00b1\u20090.26 logMAR. At 1\u00a0year follow up, the mean postoperative UCVA and BCVA were 0.11\u2009\u00b1\u20090.09 and 0.02\u2009\u00b1\u20090.03 logMAR, respectively. At the end of 6\u00a0months, around 1487 (93%) eyes had BCVA of 20\/20 and better than 20\/30 in 100% of the eyes. Mild posterior capsule opacification (PCO) was observed in 56 patients, but none required Nd YAG laser capsulotomy. There was reduction in ocular spherical aberration and Higher order aberrations (HOAs) as compared to pre operative. This explains better contrast sensitivity obtained by MTF and PSF values. The study shows that the Aktis SP IOL is safe, effective, and stable lens that could be inserted through 2.2\u00a0mm incision with satisfactory visual and refractive outcomes, even in late post-operative period.<\/jats:p>","DOI":"10.1038\/s41598-022-14315-6","type":"journal-article","created":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T17:17:49Z","timestamp":1660843069000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Visual and refractive outcomes of new intraocular lens implantation after cataract surgery"],"prefix":"10.1038","volume":"12","author":[{"given":"Bhupesh","family":"Singh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sourabh","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neha","family":"Bharti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dharitri","family":"Samantrey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dadan J.","family":"Paandey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sudhank","family":"Bharti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,8,18]]},"reference":[{"key":"14315_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2017.08.020","volume":"185","author":"RJ Olson","year":"2018","unstructured":"Olson, R. J. Cataract surgery from 1918 to the present and future-just imagine!. Am. J. Ophthalmol. 185, 10\u201313 (2018).","journal-title":"Am. J. Ophthalmol."},{"key":"14315_CR2","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1016\/j.jcrs.2007.02.029","volume":"3","author":"V Vasavada","year":"2007","unstructured":"Vasavada, V., Vasavada, V., Raj, S. M. & Vasavada, A. R. Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification; observational study. J. Cataract. Refract. Surg. 3, 1019\u20131024 (2007).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR3","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.ophtha.2012.10.026","volume":"120","author":"TV Roberts","year":"2013","unstructured":"Roberts, T. V., Lawless, M., Bali, S. J., Hodge, C. & Sutton, G. Surgical outcomes and safety of femtosecond laser cataract surgery; a prospective study of 1500 consecutive cases. Ophthalmology 120, 227\u2013233 (2013).","journal-title":"Ophthalmology"},{"key":"14315_CR4","doi-asserted-by":"publisher","first-page":"1753","DOI":"10.1016\/j.jcrs.2013.09.002","volume":"39","author":"ED Kendall","year":"2013","unstructured":"Kendall, E. D. et al. Femtosecond laser\u2014assisted cataract surgery. J. Cataract. Refract. Surg. 39, 1753\u20131763 (2013).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR5","doi-asserted-by":"publisher","first-page":"285","DOI":"10.4103\/0974-9233.90129","volume":"18","author":"M Moshirfar","year":"2011","unstructured":"Moshirfar, M., Churgin, D. S. & Hsu, M. Femtosecond laser-assisted cataract surgery: A current review. Middle East Afr. J. Ophthalmol. 18, 285\u2013291 (2011).","journal-title":"Middle East Afr. J. Ophthalmol."},{"key":"14315_CR6","first-page":"2105","volume":"8","author":"D Carson","year":"2014","unstructured":"Carson, D. et al. Optical bench performance of AcrySof((R)) IQ ReSTOR((R)), AT LISA((R)) tri, and FineVision((R)) intraocular lenses. Clin. Ophthalmol. 8, 2105\u20132113 (2014).","journal-title":"Clin. Ophthalmol."},{"issue":"5","key":"14315_CR7","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1097\/ICL.0000000000000637","volume":"46","author":"S Bhupesh","year":"2020","unstructured":"Bhupesh, S., Sharma, S., Dadia, S., Bharti, N. & Bharti, S. Comparative evaluation of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and an extended depth of focus intraocular lens. Eye Contact. Lens. 46(5), 314\u2013318 (2020).","journal-title":"Eye Contact. Lens."},{"key":"14315_CR8","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1016\/j.ophtha.2011.08.036","volume":"119","author":"JL Alio","year":"2012","unstructured":"Alio, J. L. et al. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens. Ophthalmology 119, 555\u2013563 (2012).","journal-title":"Ophthalmology"},{"issue":"5","key":"14315_CR9","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","volume":"37","author":"NE de Vries","year":"2011","unstructured":"de Vries, N. E. et al. Dissatisfaction after implantation of multifocal intraocular lenses. J. Cataract. Refract. Surg. 37(5), 859\u2013865 (2011).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR10","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s12886-015-0012-4","volume":"14","author":"J Carballo-Alvarez","year":"2015","unstructured":"Carballo-Alvarez, J., Vazquez-Molini, J. M. & Sanz-Fernandez, J. C. Visual outcomes after bilateral trifocal diffractive intraocular lens implantation. BMC Ophthalmol. 14, 26 (2015).","journal-title":"BMC Ophthalmol."},{"issue":"4","key":"14315_CR11","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1097\/APO.0000000000000253","volume":"8","author":"RR Sudhir","year":"2019","unstructured":"Sudhir, R. R., Dey, A., Bhattacharrya, S. & Bahulayan, A. AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: A clinical overview. Asia Pac. J. Ophthalmol. (Phila). 8(4), 335\u2013349 (2019).","journal-title":"Asia Pac. J. Ophthalmol. (Phila)."},{"key":"14315_CR12","first-page":"169","volume":"12","author":"SR de Silva","year":"2016","unstructured":"de Silva, S. R., Evans, J. R., Kirthi, V., Ziaei, M. & Leyland, M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst. Rev. 12, 169 (2016).","journal-title":"Cochrane Database Syst. Rev."},{"key":"14315_CR13","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1038\/sj.eye.6702153","volume":"21","author":"P Prakash","year":"2007","unstructured":"Prakash, P., Kasaby, H. E., Aggarwal, R. K. & Humfrey, S. Microincision bimanual phacoemulsification and Thinoptx implantation through a 1.70 mm incision. Eye 21, 177\u2013182 (2007).","journal-title":"Eye"},{"key":"14315_CR14","doi-asserted-by":"publisher","first-page":"1549","DOI":"10.1016\/j.jcrs.2005.01.030","volume":"31","author":"JL Alio","year":"2005","unstructured":"Alio, J. L., Rodriguez-Prats, J. L., Vianello, A. & Galal, A. Visual outcome of microincision cataract surgery with implantation of an Acri. Smart Lens. J Cataract. Refract. Surg. 31, 1549\u20131556 (2005).","journal-title":"Smart Lens. J Cataract. Refract. Surg."},{"key":"14315_CR15","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1016\/j.jcrs.2009.03.055","volume":"35","author":"JL Alio","year":"2009","unstructured":"Alio, J. L., Pinero, D. P., Ortiz, D. & Montalban, R. Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens. J. Cataract. Refract. Surg. 35, 1548\u20131554 (2009).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR16","doi-asserted-by":"publisher","first-page":"1905","DOI":"10.1016\/j.jcrs.2010.06.057","volume":"36","author":"I Can","year":"2010","unstructured":"Can, I., Takmaz, T., Bayhan, H. A. & Bostanc\u0131, C. B. Aspheric microincision intraocular lens implantation with biaxial microincision cataract surgery: Efficacy and reliability. J. Cataract. Refract. Surg. 36, 1905\u20131911 (2010).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR17","first-page":"112067212090203","volume":"30","author":"K Kawai","year":"2020","unstructured":"Kawai, K. An evaluation of glistening and stability of intraocular lens material manufactured by different methods. Eur. J. Ophthalmol. 30, 1120672120902038 (2020).","journal-title":"Eur. J. Ophthalmol."},{"key":"14315_CR18","unstructured":"Tinted and Aspheric Single-piece IOL Aktis SP https:\/\/www.nidekintl.com\/product\/ophthaloptom\/surgical\/sur_intraocular\/aktis_sp.html"},{"key":"14315_CR19","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1159\/000364808","volume":"53","author":"C von Sonnleithner","year":"2015","unstructured":"von Sonnleithner, C. et al. Clinical results and higher-order aberrations after 14-mm biaxial cataract surgery and implantation of a new aspheric intraocular lens. Ophthalm. Res. 53, 8\u201314 (2015).","journal-title":"Ophthalm. Res."},{"issue":"5","key":"14315_CR20","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1007\/s10792-016-0178-7","volume":"36","author":"B Toygar","year":"2016","unstructured":"Toygar, B., Yabas Kiziloglu, O., Toygar, O. & Hacimustafaoglu, A. M. Early clinical outcome with a new monofocal microincision intraocular lens. Int. Ophthalmol. 36(5), 657\u2013664. https:\/\/doi.org\/10.1007\/s10792-016-0178-7 (2016).","journal-title":"Int. Ophthalmol."},{"key":"14315_CR21","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/j.jcrs.2012.12.030","volume":"39","author":"MA Nanavaty","year":"2013","unstructured":"Nanavaty, M. A., Spalton, D. J., Gala, K. B., Dhital, A. & Boyce, J. Fellow-eye comparison of posterior capsule opacification between 2 aspheric microincision intraocular lenses. J. Cataract. Refract. Surg. 39, 705\u2013711 (2013).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR22","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1016\/j.jcrs.2009.04.037","volume":"35","author":"M Wilczynski","year":"2009","unstructured":"Wilczynski, M. et al. Comparison of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and bimanual phacoemulsification through 1.7 mm microincision. J. Cataract. Refract. Surg. 35, 1563\u20131569 (2009).","journal-title":"J. Cataract. Refract. Surg."},{"issue":"1","key":"14315_CR23","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1186\/s12886-017-0460-0","volume":"17","author":"HS Son","year":"2017","unstructured":"Son, H. S. et al. In vitro optical quality measurements of three intraocular lens models having identical platform. BMC Ophthalmol. 17(1), 108 (2017).","journal-title":"BMC Ophthalmol."},{"key":"14315_CR24","doi-asserted-by":"publisher","first-page":"639","DOI":"10.3928\/1081-597X-20070901-02","volume":"23","author":"A Caporossi","year":"2007","unstructured":"Caporossi, A., Martone, G., Casprini, F. & Rapisarda, L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J. Refract. Surg. 23, 639\u2013648 (2007).","journal-title":"J. Refract. Surg."},{"key":"14315_CR25","doi-asserted-by":"publisher","first-page":"2379","DOI":"10.1016\/j.jcrs.2005.10.024","volume":"31","author":"T Kawamorita","year":"2005","unstructured":"Kawamorita, T. & Uozato, H. Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro. J. Cataract. Refract. Surg 31, 2379\u20132385 (2005).","journal-title":"J. Cataract. Refract. Surg"},{"issue":"12","key":"14315_CR26","doi-asserted-by":"publisher","first-page":"1445","DOI":"10.4103\/ijo.IJO_757_17","volume":"65","author":"S Yadav","year":"2017","unstructured":"Yadav, S. et al. Comparison of visual performance and after cataract formation between two monofocal aspheric intraocular lenses following phacoemulsification for senile cataract: A randomized controlled study. Indian J. Ophthalmol. 65(12), 1445\u20131449 (2017).","journal-title":"Indian J. Ophthalmol."},{"key":"14315_CR27","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1001\/archophthalmol.2009.3","volume":"127","author":"N Awasthi","year":"2009","unstructured":"Awasthi, N., Guo, S. & Wagner, B. J. Posterior capsular opacification: A problem reduced but not yet eradicated. Arch. Ophthalmol. 127, 555\u2013562 (2009).","journal-title":"Arch. Ophthalmol."},{"key":"14315_CR28","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/j.jcrs.2003.08.007","volume":"30","author":"LE Bender","year":"2004","unstructured":"Bender, L. E. et al. Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery. Cataract. Refract. Surg. 30, 786\u2013789 (2004).","journal-title":"Cataract. Refract. Surg."},{"issue":"352","key":"14315_CR29","first-page":"60","volume":"24","author":"PG Ursell","year":"1998","unstructured":"Ursell, P. G. et al. Relationship between intraocular lens biomaterials and posterior capsule opacification. J. Cataract. Refract. Surg. 24(352), 60 (1998).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR30","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.jcrs.2007.12.024","volume":"34","author":"MA Nanavaty","year":"2008","unstructured":"Nanavaty, M. A., Spalton, D. J., Boyce, J., Brain, A. & Marshall, J. Edge profile of commercially available square-edged intraocular lenses. J. Cataract. Refract. Surg. 34, 677\u2013686 (2008).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR31","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/S0161-6420(00)00589-3","volume":"108","author":"DJ Apple","year":"2001","unstructured":"Apple, D. J. et al. Eradication of posterior capsule opacification: Documentation of a marked decrease in Nd: YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 108, 505\u2013518 (2001).","journal-title":"Ophthalmology"},{"key":"14315_CR32","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1016\/j.jcrs.2004.09.053","volume":"31","author":"W Buehl","year":"2005","unstructured":"Buehl, W. et al. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J. Cataract. Refract. Surg. 31, 954\u2013961 (2005).","journal-title":"J. Cataract. Refract. Surg."},{"key":"14315_CR33","doi-asserted-by":"publisher","first-page":"1550","DOI":"10.1016\/j.ophtha.2005.03.024","volume":"112","author":"K Hayashi","year":"2005","unstructured":"Hayashi, K. & Hayashi, H. Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. Ophthalmology 112, 1550\u20131556 (2005).","journal-title":"Ophthalmology"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14315-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14315-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14315-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T07:08:35Z","timestamp":1669360115000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14315-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,18]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["14315"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-14315-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,18]]},"assertion":[{"value":"7 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"14100"}}