{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T22:22:21Z","timestamp":1794003741640,"version":"4.8.0"},"reference-count":66,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Infectious diseases are among the leading causes of mortality worldwide. A new coronavirus named severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) was identified in Wuhan, China in 2019, and the World Health Organization (WHO) declared its outbreak, coronavirus disease 2019 (COVID-19), as a global pandemic in 2020. COVID-19 can spread quickly from person to person. One of the most challenging issues is to identify the infected individuals and prevent potential spread of SARS-CoV-2. Recently, anti-SARS-CoV-2 immunoglobulin M (IgM) and immunoglobulin G (IgG) antibody tests using immunochromatographic methods have been used as a complement to current detection methods and have provided information of the approximate course of COVID-19 infection. However, blood sampling causes pain and poses risks of infection at the needle puncture site. In this study, a novel patch sensor integrating porous microneedles and an immunochromatographic assay (PMNIA) was developed for the rapid detection of anti-SARS-CoV-2 IgM\/IgG in dermal interstitial fluid (ISF), which is a rich source of protein biomarkers, such as antibodies. Biodegradable porous microneedles (MNs) made of polylactic acid were fabricated to extract ISF from human skin by capillary effect. The extracted ISF was vertically transported and flowed into the affixed immunoassay biosensor, where specific antibodies could be detected colorimetrically on-site. Anti-SARS-CoV-2 IgM\/IgG antibodies were simultaneously detected within 3\u00a0min in vitro. Moreover, the limit of detection of anti-SARS-CoV-2 IgM and IgG concentrations was as low as 3 and 7\u00a0ng\/mL, respectively. The developed device integrating porous MNs and immunochromatographic biosensors is expected to enable minimally invasive, simple, and rapid anti-SARS-CoV-2 IgM\/IgG antibody testing. Furthermore, the compact size of the MN and biosensor-integrated device is advantageous for its widespread use. The proposed device has great potential for rapid screening of various infectious diseases in addition to COVID-19 as an effective complementary method with other diagnostic tests.<\/jats:p>","DOI":"10.1038\/s41598-022-14725-6","type":"journal-article","created":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T06:13:20Z","timestamp":1656656000000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":62,"title":["Anti-SARS-CoV-2 IgM\/IgG antibodies detection using a patch sensor containing porous microneedles and a paper-based immunoassay"],"prefix":"10.1038","volume":"12","author":[{"given":"Leilei","family":"Bao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jongho","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyu","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beomjoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,1]]},"reference":[{"key":"14725_CR1","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1038\/s41586-020-2012-7","volume":"579","author":"P Zhou","year":"2020","unstructured":"Zhou, P. et al. A pneumonia outbreak associated with a new coronavirus of probable bat origin. Nature 579, 270\u2013273 (2020).","journal-title":"Nature"},{"key":"14725_CR2","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1016\/S0140-6736(20)30673-5","volume":"395","author":"J Bedford","year":"2020","unstructured":"Bedford, J. et al. COVID-19: Towards controlling of a pandemic. Lancet 395, 1015\u20131018 (2020).","journal-title":"Lancet"},{"key":"14725_CR3","unstructured":"World Health Organization. Coronavirus disease (COVID-19) pandemic (WHO, 2020). https:\/\/www.who.int\/emergencies\/diseases\/novel-coronavirus-2019."},{"key":"14725_CR4","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1016\/S0140-6736(20)30183-5","volume":"395","author":"C Huang","year":"2020","unstructured":"Huang, C. et al. Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China. Lancet 395, 497\u2013506 (2020).","journal-title":"Lancet"},{"key":"14725_CR5","doi-asserted-by":"publisher","first-page":"2307","DOI":"10.1002\/jmv.26699","volume":"93","author":"R Alizadehsani","year":"2021","unstructured":"Alizadehsani, R. et al. Risk factors prediction, clinical outcomes, and mortality in COVID-19 patients. J. Med. Virol. 93, 2307\u20132320 (2021).","journal-title":"J. Med. Virol."},{"key":"14725_CR6","doi-asserted-by":"publisher","first-page":"e0249090","DOI":"10.1371\/journal.pone.0249090","volume":"16","author":"M Alene","year":"2021","unstructured":"Alene, M. et al. Magnitude of asymptomatic COVID-19 cases throughout the course of infection: A systematic review and meta-analysis. PLoS ONE 16, e0249090 (2021).","journal-title":"PLoS ONE"},{"key":"14725_CR7","unstructured":"Our World in Data. Coronavirus (COVID-19) Vaccinations, (2021) https:\/\/ourworldindata.org\/covid-vaccinations."},{"key":"14725_CR8","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1038\/s41562-021-01122-8","volume":"5","author":"E Mathieu","year":"2021","unstructured":"Mathieu, E. et al. A global database of COVID-19 vaccinations. Nat. Hum. Behav. 5, 947\u2013953 (2021).","journal-title":"Nat. Hum. Behav."},{"key":"14725_CR9","doi-asserted-by":"publisher","first-page":"23","DOI":"10.2807\/1560-7917.ES.2020.25.3.2000045","volume":"25","author":"VM Corman","year":"2020","unstructured":"Corman, V. M. et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill. 25, 23\u201330 (2020).","journal-title":"Euro Surveill."},{"key":"14725_CR10","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1038\/s41563-020-00906-z","volume":"20","author":"BD Kevadiya","year":"2021","unstructured":"Kevadiya, B. D. et al. Diagnostics for SARS-CoV-2 infections. Nat. Mater. 20, 593\u2013605 (2021).","journal-title":"Nat. Mater."},{"key":"14725_CR11","doi-asserted-by":"publisher","first-page":"2004","DOI":"10.1002\/jmv.25930","volume":"92","author":"J Xie","year":"2020","unstructured":"Xie, J. et al. Characteristics of patients with coronavirus disease (COVID-19) confirmed using an IgM-IgG antibody test. J. Med. Virol. 92, 2004\u20132010 (2020).","journal-title":"J. Med. Virol."},{"key":"14725_CR12","doi-asserted-by":"crossref","first-page":"e1136","DOI":"10.1002\/cti2.1136","volume":"9","author":"H Hou","year":"2020","unstructured":"Hou, H. et al. Detection of IgM and IgG antibodies in patients with coronavirus disease 2019. Clini. Transl. Immunol. 9, e1136 (2020).","journal-title":"Clini. Transl. Immunol."},{"key":"14725_CR13","doi-asserted-by":"publisher","first-page":"S74","DOI":"10.1016\/j.arth.2020.04.055","volume":"35","author":"D Jacofsky","year":"2020","unstructured":"Jacofsky, D., Jacofsky, E. M. & Jacofsky, M. Understanding antibody testing for COVID-19. J. Arthroplasty. 35, S74\u2013S81 (2020).","journal-title":"J. Arthroplasty."},{"key":"14725_CR14","doi-asserted-by":"publisher","first-page":"e00461","DOI":"10.1128\/JCM.00461-20","volume":"58","author":"W Liu","year":"2020","unstructured":"Liu, W. et al. Evaluation of nucleocapsid and spike protein-based enzyme-linked immunosorbent assays for detecting antibodies against SARS-CoV-2. J. Clin. Microbiol. 58, e00461-e520 (2020).","journal-title":"J. Clin. Microbiol."},{"key":"14725_CR15","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1038\/s41591-020-0897-1","volume":"26","author":"QX Long","year":"2020","unstructured":"Long, Q. X. et al. Antibody responses to SARS-CoV-2 in patients with COVID-19. Nat. Med. 26, 845\u2013848 (2020).","journal-title":"Nat. Med."},{"key":"14725_CR16","doi-asserted-by":"publisher","first-page":"e0244126","DOI":"10.1371\/journal.pone.0244126","volume":"15","author":"N Post","year":"2020","unstructured":"Post, N. et al. Antibody response to SARS-CoV-2 infection in humans: A systematic review. PLoS ONE 15, e0244126 (2020).","journal-title":"PLoS ONE"},{"key":"14725_CR17","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1056\/NEJMc2025179","volume":"383","author":"FJ Ibarrondo","year":"2020","unstructured":"Ibarrondo, F. J. et al. Rapid decay of anti\u2013SARS-CoV-2 antibodies in persons with mild Covid-19. N. Engl. J. Med. 383, 1085\u20131087 (2020).","journal-title":"N. Engl. J. Med."},{"key":"14725_CR18","doi-asserted-by":"publisher","first-page":"112572","DOI":"10.1016\/j.bios.2020.112572","volume":"169","author":"X Tan","year":"2020","unstructured":"Tan, X. et al. Rapid and quantitative detection of SARS-CoV-2 specific IgG for convalescent serum evaluation. Biosens. Bioelectron. 169, 112572 (2020).","journal-title":"Biosens. Bioelectron."},{"key":"14725_CR19","doi-asserted-by":"publisher","first-page":"eabe0367","DOI":"10.1126\/sciimmunol.abe0367","volume":"5","author":"AS Iyer","year":"2020","unstructured":"Iyer, A. S. et al. Persistence and decay of human antibody responses to the receptor binding domain of SARS-CoV-2 spike protein in COVID-19 patients. Sci. Immunol. 5, eabe0367 (2020).","journal-title":"Sci. Immunol."},{"key":"14725_CR20","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1002\/jmv.25727","volume":"92","author":"Z Li","year":"2020","unstructured":"Li, Z. et al. Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis. J. Med. Virol. 92, 1518\u20131524 (2020).","journal-title":"J. Med. Virol."},{"key":"14725_CR21","doi-asserted-by":"publisher","first-page":"e90","DOI":"10.1002\/ctm2.90","volume":"10","author":"H Li","year":"2020","unstructured":"Li, H. et al. A new and rapid approach for detecting COVID-19 based on S1 protein fragments. Clin. Transl. Med. 10, e90 (2020).","journal-title":"Clin. Transl. Med."},{"key":"14725_CR22","doi-asserted-by":"publisher","first-page":"121737","DOI":"10.1016\/j.talanta.2020.121737","volume":"223","author":"S Cavalera","year":"2021","unstructured":"Cavalera, S. et al. A multi-target lateral flow immunoassay enabling the specific and sensitive detection of total antibodies to SARS COV-2. Talanta 223, 121737 (2021).","journal-title":"Talanta"},{"key":"14725_CR23","doi-asserted-by":"publisher","first-page":"5345","DOI":"10.1039\/D0AN00629G","volume":"145","author":"T Wen","year":"2020","unstructured":"Wen, T. et al. Development of a lateral flow immunoassay strip for rapid detection of IgG antibody against SARS-CoV-2 virus. Analyst. 145, 5345\u20135352 (2020).","journal-title":"Analyst."},{"key":"14725_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13104-020-05212-0","volume":"13","author":"B Ragnesola","year":"2020","unstructured":"Ragnesola, B. et al. COVID19 antibody detection using lateral flow assay tests in a cohort of convalescent plasma donors. BMC Res. Notes. 13, 1\u20137 (2020).","journal-title":"BMC Res. Notes."},{"key":"14725_CR25","doi-asserted-by":"publisher","first-page":"12550","DOI":"10.1021\/acsomega.0c01554","volume":"5","author":"C Huang","year":"2020","unstructured":"Huang, C., Wen, T., Shi, F. J., Zeng, X. Y. & Jiao, Y. J. Rapid detection of IgM antibodies against the SARS-CoV-2 virus via colloidal gold nanoparticle-based lateral-flow assay. ACS Omega 5, 12550\u201312556 (2020).","journal-title":"ACS Omega"},{"key":"14725_CR26","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.1039\/D0QM00294A","volume":"4","author":"L Zeng","year":"2020","unstructured":"Zeng, L. et al. Rapid, ultrasensitive and highly specific biosensor for the diagnosis of SARS-CoV-2 in clinical blood samples. Mater. Chem. Front. 4, 2000\u20132005 (2020).","journal-title":"Mater. Chem. Front."},{"key":"14725_CR27","doi-asserted-by":"publisher","first-page":"112909","DOI":"10.1016\/j.jim.2020.112909","volume":"489","author":"MA Black","year":"2021","unstructured":"Black, M. A. et al. Analytical performance of lateral flow immunoassay for SARS-CoV-2 exposure screening on venous and capillary blood samples. J. Immunol. Methods. 489, 112909 (2021).","journal-title":"J. Immunol. Methods."},{"key":"14725_CR28","first-page":"188","volume":"25","author":"SM Geaghan","year":"2014","unstructured":"Geaghan, S. M. Infection transmission associated with point of care testing and the laboratory\u2019s role in risk reduction. J. Int. Fed. Clin. Chem. Lab. Med. 25, 188\u2013194 (2014).","journal-title":"J. Int. Fed. Clin. Chem. Lab. Med."},{"key":"14725_CR29","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1021\/js980042+","volume":"87","author":"S Henry","year":"1998","unstructured":"Henry, S., McAllister, D. V., Allen, M. G. & Prausnitz, M. R. Microfabricated microneedles: A novel approach to transdermal drug delivery. J. Pharm. Sci. 87, 922\u2013925 (1998).","journal-title":"J. Pharm. Sci."},{"key":"14725_CR30","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1213\/00000539-200102000-00041","volume":"92","author":"S Kaushik","year":"2011","unstructured":"Kaushik, S. et al. Lack of pain associated with microfabricated microneedles. Anesth. Analg. 92, 502\u2013504 (2011).","journal-title":"Anesth. Analg."},{"key":"14725_CR31","doi-asserted-by":"publisher","first-page":"e10109","DOI":"10.1002\/mds3.10109","volume":"3","author":"H Lee","year":"2020","unstructured":"Lee, H. et al. Porous microneedles on a paper for screening test of prediabetes. Med. Devices Sens. 3, e10109 (2020).","journal-title":"Med. Devices Sens."},{"key":"14725_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10544-020-00532-1","volume":"22","author":"K Takeuchi","year":"2020","unstructured":"Takeuchi, K., Takama, N., Kinoshita, R., Okitsu, T. & Kim, B. Flexible and porous microneedles of PDMS for continuous glucose monitoring. Biomed. Microdevices 22, 1\u201312 (2020).","journal-title":"Biomed. Microdevices"},{"key":"14725_CR33","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s13346-021-01050-0","volume":"12","author":"K Takeuchi","year":"2022","unstructured":"Takeuchi, K. et al. Microfluidic chip connected to porous microneedle array for continuous ISF sampling. Drug Deliv. Transl. Res. 12, 435\u2013434 (2022).","journal-title":"Drug Deliv. Transl. Res."},{"key":"14725_CR34","doi-asserted-by":"publisher","first-page":"1901201","DOI":"10.1002\/adhm.201901201","volume":"9","author":"R He","year":"2020","unstructured":"He, R. et al. A hydrogel microneedle patch for point-of-care testing based on skin interstitial fluid. Adv. Healthc. Mater. 9, 1901201 (2020).","journal-title":"Adv. Healthc. Mater."},{"key":"14725_CR35","doi-asserted-by":"publisher","first-page":"1702243","DOI":"10.1002\/adma.201702243","volume":"29","author":"H Chang","year":"2017","unstructured":"Chang, H. et al. A swellable microneedle patch to rapidly extract skin interstitial fluid for timely metabolic analysis. Adv. Mater. 29, 1702243 (2017).","journal-title":"Adv. Mater."},{"key":"14725_CR36","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.snb.2019.02.020","volume":"287","author":"J Gao","year":"2019","unstructured":"Gao, J., Huang, W., Chen, Z., Yi, C. & Jiang, L. Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer. Sens. Actuators B Chem. 287, 102\u2013110 (2019).","journal-title":"Sens. Actuators B Chem."},{"key":"14725_CR37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s42003-018-0170-z","volume":"1","author":"PR Miller","year":"2018","unstructured":"Miller, P. R. et al. Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles. Commun. Biol. 1, 1\u201311 (2018).","journal-title":"Commun. Biol."},{"key":"14725_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41378-020-00206-1","volume":"6","author":"X Jiang","year":"2020","unstructured":"Jiang, X. & Lillehoj, P. B. Microneedle-based skin patch for blood-free rapid diagnostic testing. Microsyst. Nanoeng. 6, 1\u201311 (2020).","journal-title":"Microsyst. Nanoeng."},{"key":"14725_CR39","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1038\/s41551-020-00672-y","volume":"5","author":"Z Wang","year":"2021","unstructured":"Wang, Z. et al. Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid. Nat. Biomed. Eng. 5, 64\u201376 (2021).","journal-title":"Nat. Biomed. Eng."},{"key":"14725_CR40","doi-asserted-by":"publisher","first-page":"2788","DOI":"10.1039\/D0LC00567C","volume":"20","author":"CJ Bolton","year":"2020","unstructured":"Bolton, C. J. et al. Hollow silicon microneedle fabrication using advanced plasma etch technologies for applications in transdermal drug delivery. Lab Chip 20, 2788\u20132795 (2020).","journal-title":"Lab Chip"},{"key":"14725_CR41","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1109\/JMEMS.2014.2307320","volume":"23","author":"PC Wang","year":"2014","unstructured":"Wang, P. C., Paik, S. J., Kim, S. H. & Allen, M. G. Hypodermic-needle-like hollow polymer microneedle array: Fabrication and characterization. J. Microelectromech. Syst 23, 991\u2013998 (2014).","journal-title":"J. Microelectromech. Syst"},{"key":"14725_CR42","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1007\/s13346-021-01045-x","volume":"12","author":"L Bao","year":"2021","unstructured":"Bao, L., Park, J., Bonfante, G. & Kim, B. Recent advances in porous microneedles: Materials, fabrication, and transdermal applications. Drug Deliv. Transl. Res. 12, 395\u2013414 (2021).","journal-title":"Drug Deliv. Transl. Res."},{"key":"14725_CR43","doi-asserted-by":"publisher","first-page":"2100171","DOI":"10.1002\/mame.202100171","volume":"306","author":"H Abe","year":"2021","unstructured":"Abe, H., Matsui, Y., Kimura, N. & Nishizawa, M. Biodegradable porous microneedles for an electric skin patch. Macro. Mater. Eng. 306, 2100171 (2021).","journal-title":"Macro. Mater. Eng."},{"key":"14725_CR44","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1038\/s41587-019-0045-y","volume":"37","author":"J Kim","year":"2019","unstructured":"Kim, J., Campbell, A. S., de \u00c1vila, B. E. F. & Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 37, 389\u2013406 (2019).","journal-title":"Nat. Biotechnol."},{"key":"14725_CR45","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1038\/s41587-019-0040-3","volume":"37","author":"J Heikenfeld","year":"2019","unstructured":"Heikenfeld, J. et al. Accessing analytes in biofluids for peripheral biochemical monitoring. Nat. Biotechnol. 37, 407\u2013419 (2019).","journal-title":"Nat. Biotechnol."},{"key":"14725_CR46","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1046\/j.0022-202X.2003.22110.x","volume":"122","author":"N Otberg","year":"2004","unstructured":"Otberg, N. et al. Variations of hair follicle size and distribution in different body site. J. Investig. Dermatol. 122, 14\u201319 (2004).","journal-title":"J. Investig. Dermatol."},{"key":"14725_CR47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41378-021-00284-9","volume":"7","author":"L Wu","year":"2021","unstructured":"Wu, L., Park, J., Kamaki, Y. & Kim, B. Optimization of the fused deposition modeling-based fabrication process for polylactic acid microneedles. Microsyst. Nanoeng. 7, 1\u201313 (2021).","journal-title":"Microsyst. Nanoeng."},{"key":"14725_CR48","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1080\/14737159.2021.1913123","volume":"21","author":"JJ Wang","year":"2021","unstructured":"Wang, J. J., Zhang, N., Richardson, S. A. & Wu, J. V. Rapid lateral flow tests for the detection of SARS-CoV-2 neutralizing antibodies. Expert Rev. Mol. Diagn. 21, 363\u2013370 (2021).","journal-title":"Expert Rev. Mol. Diagn."},{"key":"14725_CR49","doi-asserted-by":"publisher","first-page":"295","DOI":"10.3390\/bios11090295","volume":"11","author":"WWW Hsiao","year":"2021","unstructured":"Hsiao, W. W. W. et al. Recent advances in novel lateral flow technologies for detection of COVID-19. Biosensors 11, 295 (2021).","journal-title":"Biosensors"},{"key":"14725_CR50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41467-021-20948-4","volume":"12","author":"S Kusama","year":"2021","unstructured":"Kusama, S. et al. Transdermal electroosmotic flow generated by a porous microneedle array patch. Nat. Commun. 12, 1\u201311 (2021).","journal-title":"Nat. Commun."},{"key":"14725_CR51","doi-asserted-by":"publisher","first-page":"8493","DOI":"10.1016\/j.biortech.2010.05.092","volume":"101","author":"KM Nampoothiri","year":"2010","unstructured":"Nampoothiri, K. M., Nair, N. R. & John, R. P. An overview of the recent developments in polylactide (PLA) research. Bioresour. Technol. 101, 8493\u20138501 (2010).","journal-title":"Bioresour. Technol."},{"key":"14725_CR52","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/BF00714709","volume":"7","author":"LV Smirnov","year":"1967","unstructured":"Smirnov, L. V., Platonova, N. V. & Popov, K. R. Color change of poly (vinyl alcohol) during heat treatment (dehydration and formation of polyene fractions). J. Appl. Spectrosc. 7, 71\u201374 (1967).","journal-title":"J. Appl. Spectrosc."},{"key":"14725_CR53","doi-asserted-by":"publisher","first-page":"463001","DOI":"10.1088\/1361-6463\/ac1623","volume":"54","author":"M Thulliez","year":"2021","unstructured":"Thulliez, M., Bastin, O., Nonclercq, A., Delchambre, A. & Reniers, F. Gel models to assess distribution and diffusion of reactive species from cold atmospheric plasma: An overview for plasma medicine applications. J. Phys. D: Appl. Phys. 54, 463001 (2021).","journal-title":"J. Phys. D: Appl. Phys."},{"key":"14725_CR54","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.jconrel.2005.02.002","volume":"104","author":"JH Park","year":"2005","unstructured":"Park, J. H., Allen, M. G. & Prausnitz, M. R. Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery. J. Control. Release 104, 51\u201366 (2005).","journal-title":"J. Control. Release"},{"key":"14725_CR55","doi-asserted-by":"publisher","first-page":"129196","DOI":"10.1016\/j.snb.2020.129196","volume":"329","author":"H Liu","year":"2021","unstructured":"Liu, H. et al. Development of a SERS-based lateral flow immunoassay for rapid and ultra-sensitive detection of anti-SARS-CoV-2 IgM\/IgG in clinical samples. Sens. Actuators B Chem. 329, 129196 (2021).","journal-title":"Sens. Actuators B Chem."},{"key":"14725_CR56","doi-asserted-by":"publisher","first-page":"120601","DOI":"10.1063\/5.0021842","volume":"117","author":"T Peng","year":"2020","unstructured":"Peng, T. et al. Enhancing sensitivity of lateral flow assay with application to SARS-CoV-2. Appl. Phys. Lett. 117, 120601 (2020).","journal-title":"Appl. Phys. Lett."},{"key":"14725_CR57","doi-asserted-by":"publisher","first-page":"12391","DOI":"10.1021\/acs.analchem.1c02305","volume":"93","author":"S Srivastav","year":"2021","unstructured":"Srivastav, S. et al. Rapid and sensitive SERS-based lateral flow test for SARS-CoV2-specific IgM\/IgG antibodies. Anal. Chem. 93, 12391\u201312399 (2021).","journal-title":"Anal. Chem."},{"key":"14725_CR58","doi-asserted-by":"publisher","first-page":"4255","DOI":"10.1039\/D0LC00828A","volume":"20","author":"Z Wang","year":"2020","unstructured":"Wang, Z. et al. A point-of-care selenium nanoparticle-based test for the combined detection of anti-SARS-CoV-2 IgM and IgG in human serum and blood. Lab. Chip 20, 4255\u20134261 (2020).","journal-title":"Lab. Chip"},{"key":"14725_CR59","doi-asserted-by":"publisher","first-page":"3638","DOI":"10.1002\/pmic.200600938","volume":"7","author":"J Kool","year":"2007","unstructured":"Kool, J. et al. Suction blister fluid as potential body fluid for biomarker proteins. Proteomics 7, 3638\u20133650 (2007).","journal-title":"Proteomics"},{"key":"14725_CR60","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1021\/acs.jproteome.7b00642","volume":"17","author":"BQ Tran","year":"2018","unstructured":"Tran, B. Q. et al. Proteomic characterization of dermal interstitial fluid extracted using a novel microneedle-assisted technique. J. Proteome Res. 17, 479\u2013485 (2018).","journal-title":"J. Proteome Res."},{"key":"14725_CR61","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/0045-7949(88)90011-9","volume":"28","author":"WG Smith","year":"1988","unstructured":"Smith, W. G. Analytic solutions for tapered column buckling. Comput. Struct. 28, 677\u2013681 (1988).","journal-title":"Comput. Struct."},{"key":"14725_CR62","doi-asserted-by":"publisher","first-page":"2113","DOI":"10.1016\/j.biomaterials.2007.12.048","volume":"29","author":"JW Lee","year":"2008","unstructured":"Lee, J. W., Park, J. H. & Prausnitz, M. R. Dissolving microneedles for transdermal drug delivery. Biomaterials 29, 2113\u20132124 (2008).","journal-title":"Biomaterials"},{"key":"14725_CR63","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.molimm.2014.10.023","volume":"66","author":"A Summerfield","year":"2015","unstructured":"Summerfield, A., Meurens, F. & Ricklin, M. E. The immunology of the porcine skin and its value as a model for human skin. Mol. Immunol. 66, 14\u201321 (2015).","journal-title":"Mol. Immunol."},{"key":"14725_CR64","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1016\/j.ijpharm.2018.06.002","volume":"547","author":"D Nicholas","year":"2018","unstructured":"Nicholas, D. et al. Rapid paper based colorimetric detection of glucose using a hollow microneedle device. Int. J. Pharm. 547, 244\u2013249 (2018).","journal-title":"Int. J. Pharm."},{"key":"14725_CR65","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.talanta.2006.12.045","volume":"72","author":"F Barni","year":"2007","unstructured":"Barni, F., Lewis, S. W., Berti, A., Miskelly, G. M. & Lago, G. Forensic application of the luminol reaction as a presumptive test for latent blood detection. Talanta 72, 896\u2013913 (2007).","journal-title":"Talanta"},{"key":"14725_CR66","doi-asserted-by":"publisher","first-page":"3788","DOI":"10.1038\/s41596-020-0357-x","volume":"15","author":"C Parolo","year":"2020","unstructured":"Parolo, C. et al. Tutorial: Design and fabrication of nanoparticle-based lateral-flow immunoassays. Nat. Protoc. 15, 3788\u20133816 (2020).","journal-title":"Nat. Protoc."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14725-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14725-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14725-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,23]],"date-time":"2023-11-23T20:23:25Z","timestamp":1700771005000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-14725-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,1]]},"references-count":66,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["14725"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-14725-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,1]]},"assertion":[{"value":"16 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10693"}}