{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:20:44Z","timestamp":1784161244355,"version":"3.55.0"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Fluorescence spectroscopy has the potential to identify discriminatory signatures, crucial for early diagnosis of cervical cancer. We demonstrate here the design, fabrication and testing of a 3D printed smartphone based spectroscopic device. Polarized fluorescence and elastic scattering spectra are captured through the device using a 405 nm laser and a white LED source respectively. The device has been calibrated by comparison of spectra of standard fluorophores (Flavin adenine dinucleotide, fluorescein, rhodamine, and porphyrin) with the corresponding spectra collected from a commercial spectrometer. A few cervical tissue spectra have also been captured for proof of its applicability as a portable, standalone device for the collection of intrinsic fluorescence spectra from human cervix.<\/jats:p>","DOI":"10.1038\/s41598-022-15007-x","type":"journal-article","created":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T15:09:17Z","timestamp":1656688157000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Design, fabrication and testing of 3D printed smartphone-based device for collection of intrinsic fluorescence from human cervix"],"prefix":"10.1038","volume":"12","author":[{"given":"Shivam","family":"Shukla","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amar Nath","family":"Sah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diganta","family":"Hatiboruah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shikha","family":"Ahirwar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pabitra","family":"Nath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asima","family":"Pradhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,1]]},"reference":[{"key":"15007_CR1","unstructured":"Ferlay, J. et\u00a0al. Global Cancer Observatory: Cancer Today. (International Agency for Research on Cancer, 2020)."},{"key":"15007_CR2","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1006\/gyno.1994.1007","volume":"52","author":"N Ramanujam","year":"1994","unstructured":"Ramanujam, N. et al. Fluorescence spectroscopy: A diagnostic tool for cervical intraepithelial neoplasia (cin). Gynecol. Oncol. 52, 31\u201338 (1994).","journal-title":"Gynecol. Oncol."},{"key":"15007_CR3","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1117\/1.429874","volume":"3","author":"NN Zhadin","year":"1998","unstructured":"Zhadin, N. N. & Alfano, R. R. Correction of the internal absorption effect in fluorescence emission and excitation spectra from absorbing and highly scattering media: Theory and experiment. J. Biomed. Opt. 3, 171\u2013186 (1998).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR4","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1593\/neo.81386","volume":"11","author":"VT-C Chang","year":"2009","unstructured":"Chang, V.T.-C. et al. Quantitative physiology of the precancerous cervix in vivo through optical spectroscopy. Neoplasia 11, 325\u2013332 (2009).","journal-title":"Neoplasia"},{"key":"15007_CR5","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1038\/nrc2462","volume":"8","author":"N Thekkek","year":"2008","unstructured":"Thekkek, N. & Richards-Kortum, R. Optical imaging for cervical cancer detection: Solutions for a continuing global problem. Nat. Rev. Cancer 8, 725\u2013731 (2008).","journal-title":"Nat. Rev. Cancer"},{"key":"15007_CR6","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1002\/cncr.23324","volume":"112","author":"RJ Mallia","year":"2008","unstructured":"Mallia, R. J. et al. Laser-induced autofluorescence spectral ratio reference standard for early discrimination of oral cancer. Cancer 112, 1503\u20131512 (2008).","journal-title":"Cancer"},{"key":"15007_CR7","first-page":"682","volume":"62","author":"I Georgakoudi","year":"2002","unstructured":"Georgakoudi, I. et al. Nad (p) h and collagen as in vivo quantitative fluorescent biomarkers of epithelial precancerous changes. Can. Res. 62, 682\u2013687 (2002).","journal-title":"Can. Res."},{"key":"15007_CR8","doi-asserted-by":"publisher","first-page":"4764","DOI":"10.1016\/S0021-9258(17)30079-0","volume":"254","author":"B Chance","year":"1979","unstructured":"Chance, B., Schoener, B., Oshino, R., Itshak, F. & Nakase, Y. Oxidation-reduction ratio studies of mitochondria in freeze-trapped samples. nadh and flavoprotein fluorescence signals. J. Biol. Chem. 254, 4764\u20134771 (1979).","journal-title":"J. Biol. Chem."},{"key":"15007_CR9","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1109\/JQE.1984.1072322","volume":"20","author":"R Alfano","year":"1984","unstructured":"Alfano, R. et al. Laser induced fluorescence spectroscopy from native cancerous and normal tissue. IEEE J. Quantum Electron. 20, 1507\u20131511 (1984).","journal-title":"IEEE J. Quantum Electron."},{"key":"15007_CR10","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1364\/JOSAB.6.001015","volume":"6","author":"R Alfano","year":"1989","unstructured":"Alfano, R., Pradhan, A., Tang, G. & Wahl, S. Optical spectroscopic diagnosis of cancer and normal breast tissues. JOSA B 6, 1015\u20131023 (1989).","journal-title":"JOSA B"},{"key":"15007_CR11","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1111\/j.1751-1097.1996.tb03130.x","volume":"64","author":"N Ramanujam","year":"1996","unstructured":"Ramanujam, N. et al. Cervical precancer detection using a multivariate statistical algorithm based on laser-induced fluorescence spectra at multiple excitation wavelengths. Photochem. Photobiol. 64, 720\u2013735 (1996).","journal-title":"Photochem. Photobiol."},{"key":"15007_CR12","doi-asserted-by":"publisher","DOI":"10.1117\/1.1899686","volume":"10","author":"SK Chang","year":"2005","unstructured":"Chang, S. K. et al. Combined reflectance and fluorescence spectroscopy for in vivo detection of cervical pre-cancer. J. Biomed. Opt. 10, 024031 (2005).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR13","doi-asserted-by":"publisher","DOI":"10.1117\/1.3558840","volume":"16","author":"Q Liu","year":"2011","unstructured":"Liu, Q. et al. Compact point-detection fluorescence spectroscopy system for quantifying intrinsic fluorescence redox ratio in brain cancer diagnostics. J. Biomed. Opt. 16, 037004 (2011).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR14","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.jphotobiol.2006.05.004","volume":"85","author":"S Majumder","year":"2006","unstructured":"Majumder, S., Gupta, A., Gupta, S., Ghosh, N. & Gupta, P. Multi-class classification algorithm for optical diagnosis of oral cancer. J. Photochem. Photobiol. B 85, 109\u2013117 (2006).","journal-title":"J. Photochem. Photobiol. B"},{"key":"15007_CR15","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.pdpdt.2014.03.009","volume":"11","author":"ALN Francisco","year":"2014","unstructured":"Francisco, A. L. N. et al. Fluorescence spectroscopy for the detection of potentially malignant disorders and squamous cell carcinoma of the oral cavity. Photodiagn. Photodyn. Ther. 11, 82\u201390 (2014).","journal-title":"Photodiagn. Photodyn. Ther."},{"key":"15007_CR16","doi-asserted-by":"publisher","first-page":"3942","DOI":"10.1158\/0008-5472.CAN-17-0668","volume":"77","author":"M Jermyn","year":"2017","unstructured":"Jermyn, M. et al. Highly accurate detection of cancer in situ with intraoperative, label-free, multimodal optical spectroscopy. Can. Res. 77, 3942\u20133950 (2017).","journal-title":"Can. Res."},{"key":"15007_CR17","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.23.1.015005","volume":"23","author":"BL Meena","year":"2018","unstructured":"Meena, B. L. et al. Intrinsic fluorescence for cervical precancer detection using polarized light based in-house fabricated portable device. J. Biomed. Opt. 23, 015005 (2018).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR18","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s10895-017-2203-2","volume":"28","author":"P Kumar","year":"2018","unstructured":"Kumar, P., Singh, A., Kanaujia, S. K. & Pradhan, A. Human saliva for oral precancer detection: A comparison of fluorescence and stokes shift spectroscopy. J. Fluoresc. 28, 419\u2013426 (2018).","journal-title":"J. Fluoresc."},{"key":"15007_CR19","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.bios.2014.04.014","volume":"60","author":"SC Gopinath","year":"2014","unstructured":"Gopinath, S. C., Tang, T.-H., Chen, Y., Citartan, M. & Lakshmipriya, T. Bacterial detection: From microscope to smartphone. Biosens. Bioelectron. 60, 332\u2013342 (2014).","journal-title":"Biosens. Bioelectron."},{"key":"15007_CR20","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1039\/C4LC01358A","volume":"15","author":"HC Koydemir","year":"2015","unstructured":"Koydemir, H. C. et al. Rapid imaging, detection and quantification of giardia lamblia cysts using mobile-phone based fluorescent microscopy and machine learning. Lab Chip 15, 1284\u20131293 (2015).","journal-title":"Lab Chip"},{"key":"15007_CR21","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1109\/LPT.2013.2297700","volume":"26","author":"S Dutta","year":"2014","unstructured":"Dutta, S., Choudhury, A. & Nath, P. Evanescent wave coupled spectroscopic sensing using smartphone. IEEE Photon. Technol. Lett. 26, 568\u2013570 (2014).","journal-title":"IEEE Photon. Technol. Lett."},{"key":"15007_CR22","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1002\/jbio.201500329","volume":"10","author":"S Dutta","year":"2017","unstructured":"Dutta, S. et al. Protein, enzyme and carbohydrate quantification using smartphone through colorimetric digitization technique. J. Biophoton. 10, 623\u2013633 (2017).","journal-title":"J. Biophoton."},{"key":"15007_CR23","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1016\/j.bios.2015.07.072","volume":"74","author":"M-Y Jia","year":"2015","unstructured":"Jia, M.-Y. et al. The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine. Biosens. Bioelectron. 74, 1029\u20131037 (2015).","journal-title":"Biosens. Bioelectron."},{"key":"15007_CR24","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0006320","volume":"4","author":"DN Breslauer","year":"2009","unstructured":"Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A. & Fletcher, D. A. Mobile phone based clinical microscopy for global health applications. PLoS One 4, e6320 (2009).","journal-title":"PLoS One"},{"key":"15007_CR25","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0017150","volume":"6","author":"ZJ Smith","year":"2011","unstructured":"Smith, Z. J. et al. Cell-phone-based platform for biomedical device development and education applications. PLoS One 6, e17150 (2011).","journal-title":"PLoS One"},{"key":"15007_CR26","doi-asserted-by":"publisher","first-page":"2124","DOI":"10.1039\/c3lc40991k","volume":"13","author":"D Gallegos","year":"2013","unstructured":"Gallegos, D. et al. Label-free biodetection using a smartphone. Lab Chip 13, 2124\u20132132 (2013).","journal-title":"Lab Chip"},{"key":"15007_CR27","doi-asserted-by":"publisher","first-page":"8805","DOI":"10.1021\/ac502080t","volume":"86","author":"H Yu","year":"2014","unstructured":"Yu, H., Tan, Y. & Cunningham, B. T. Smartphone fluorescence spectroscopy. Anal. Chem. 86, 8805\u20138813 (2014).","journal-title":"Anal. Chem."},{"key":"15007_CR28","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1364\/OL.41.002237","volume":"41","author":"MA Hossain","year":"2016","unstructured":"Hossain, M. A., Canning, J., Cook, K. & Jamalipour, A. Optical fiber smartphone spectrometer. Opt. Lett. 41, 2237\u20132240 (2016).","journal-title":"Opt. Lett."},{"key":"15007_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep32504","volume":"6","author":"AJ Das","year":"2016","unstructured":"Das, A. J., Wahi, A., Kothari, I. & Raskar, R. Ultra-portable, wireless smartphone spectrometer for rapid, non-destructive testing of fruit ripeness. Sci. Rep. 6, 1\u20138 (2016).","journal-title":"Sci. Rep."},{"key":"15007_CR30","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1021\/acs.analchem.6b03424","volume":"89","author":"I Hussain","year":"2017","unstructured":"Hussain, I., Ahamad, K. U. & Nath, P. Low-cost, robust, and field portable smartphone platform photometric sensor for fluoride level detection in drinking water. Anal. Chem. 89, 767\u2013775 (2017).","journal-title":"Anal. Chem."},{"key":"15007_CR31","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1016\/j.snb.2016.08.102","volume":"239","author":"I Hussain","year":"2017","unstructured":"Hussain, I., Das, M., Ahamad, K. U. & Nath, P. Water salinity detection using a smartphone. Sens. Actuators B Chem. 239, 1042\u20131050 (2017).","journal-title":"Sens. Actuators B Chem."},{"key":"15007_CR32","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.sna.2018.03.008","volume":"274","author":"H Ding","year":"2018","unstructured":"Ding, H., Chen, C., Qi, S., Han, C. & Yue, C. Smartphone-based spectrometer with high spectral accuracy for mhealth application. Sens. Actuators A 274, 94\u2013100 (2018).","journal-title":"Sens. Actuators A"},{"key":"15007_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-52327-x","volume":"9","author":"X Hong","year":"2019","unstructured":"Hong, X., Lu, T., Fruzyna, L. & Yu, B. A dual-modality smartphone microendoscope for quantifying the physiological and morphological properties of epithelial tissues. Sci. Rep. 9, 1\u20139 (2019).","journal-title":"Sci. Rep."},{"key":"15007_CR34","doi-asserted-by":"publisher","first-page":"3320","DOI":"10.1364\/OE.11.003320","volume":"11","author":"NC Biswal","year":"2003","unstructured":"Biswal, N. C., Gupta, S., Ghosh, N. & Pradhan, A. Recovery of turbidity free fluorescence from measured fluorescence: An experimental approach. Opt. Express 11, 3320\u20133331 (2003).","journal-title":"Opt. Express"},{"key":"15007_CR35","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.19.12.127003","volume":"19","author":"S Devi","year":"2014","unstructured":"Devi, S., Panigrahi, P. K. & Pradhan, A. Detecting cervical cancer progression through extracted intrinsic fluorescence and principal component analysis. J. Biomed. Opt. 19, 127003 (2014).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR36","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.24.3.035008","volume":"24","author":"BL Meena","year":"2019","unstructured":"Meena, B. L., Agarwal, A., Pantola, C., Pandey, K. & Pradhan, A. Concentration of fad as a marker for cervical precancer detection. J. Biomed. Opt. 24, 035008 (2019).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR37","first-page":"119201J","volume":"11920","author":"S Shukla","year":"2021","unstructured":"Shukla, S., Ahirwar, S. & Pradhan, A. A smartphone-based 3d printed prototype for polarized fluorescence collection from human cervix. Proc. of SPIE-OSA 11920, 119201J\u20131 (2021).","journal-title":"Proc. of SPIE-OSA"},{"key":"15007_CR38","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1039\/C5LC01226K","volume":"16","author":"C Zhang","year":"2016","unstructured":"Zhang, C. et al. G-fresnel smartphone spectrometer. Lab Chip 16, 246\u2013250 (2016).","journal-title":"Lab Chip"},{"key":"15007_CR39","doi-asserted-by":"publisher","first-page":"5935","DOI":"10.1364\/AO.57.005935","volume":"57","author":"A Bayram","year":"2018","unstructured":"Bayram, A., Yalcin, E., Demic, S., Gunduz, O. & Solmaz, M. E. Development and application of a low-cost smartphone-based turbidimeter using scattered light. Appl. Opt. 57, 5935\u20135940 (2018).","journal-title":"Appl. Opt."},{"key":"15007_CR40","doi-asserted-by":"publisher","first-page":"7529","DOI":"10.1364\/AO.45.007529","volume":"45","author":"S Gupta","year":"2006","unstructured":"Gupta, S., Raja, V. S. & Pradhan, A. Simultaneous extraction of optical transport parameters and intrinsic fluorescence of tissue mimicking model media using a spatially resolved fluorescence technique. Appl. Opt. 45, 7529\u20137537 (2006).","journal-title":"Appl. Opt."},{"key":"15007_CR41","doi-asserted-by":"publisher","DOI":"10.1117\/1.2907161","volume":"13","author":"GM Palmer","year":"2008","unstructured":"Palmer, G. M. & Ramanujam, N. Monte-carlo-based model for the extraction of intrinsic fluorescence from turbid media. J. Biomed. Opt. 13, 024017 (2008).","journal-title":"J. Biomed. Opt."},{"key":"15007_CR42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jphotobiol.2015.06.019","volume":"151","author":"S Devi","year":"2015","unstructured":"Devi, S., Ghosh, N. & Pradhan, A. A technique for correction of attenuations in synchronous fluorescence spectroscopy. J. Photochem. Photobiol. B 151, 1\u20139 (2015).","journal-title":"J. Photochem. Photobiol. B"},{"key":"15007_CR43","doi-asserted-by":"publisher","first-page":"1974","DOI":"10.1364\/BOE.416753","volume":"12","author":"I Hussain","year":"2021","unstructured":"Hussain, I. & Bowden, A. K. Smartphone-based optical spectroscopic platforms for biomedical applications: A review. Biomed. Opt. Express 12, 1974\u20131998 (2021).","journal-title":"Biomed. Opt. Express"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15007-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15007-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15007-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T06:38:03Z","timestamp":1669358283000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15007-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,1]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["15007"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-15007-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,1]]},"assertion":[{"value":"8 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11192"}}