{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:49:55Z","timestamp":1792784995226,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T00:00:00Z","timestamp":1656115200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T00:00:00Z","timestamp":1656115200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["FKZ: 13GW0302B"],"award-info":[{"award-number":["FKZ: 13GW0302B"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013920","name":"Uniwersytet im. Adama Mickiewicza w Poznaniu","doi-asserted-by":"publisher","award":["Faculty of Chemistry"],"award-info":[{"award-number":["Faculty of Chemistry"]}],"id":[{"id":"10.13039\/501100013920","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Herzzentrum G\u00f6ttingen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Magnetically controlled growing rods (MCGRs) are an effective treatment method for early-onset scoliosis (EOS). In recent years, increasing titanium wear was observed in tissue adjacent to implants and in blood samples of these patients. This study aims to investigate the potential correlation between amount of metal loss and titanium levels in blood during MCGR treatment as well as influencing factors for metal wear. In total, 44 MCGRs (\n                    <jats:italic>n<\/jats:italic>\n                    \u2009=\u200923 patients) were retrieved after an average of 2.6\u00a0years of implantation and analyzed using a tactile measurement instrument and subsequent metal loss calculation. Titanium plasma levels (\n                    <jats:italic>n<\/jats:italic>\n                    \u2009=\u200923) were obtained using inductively coupled plasma-mass spectrometry (ICP-MS). The correlation of both parameters as well as influencing factors were analyzed. Titanium abrasion on MCGRs was observed in the majority of implants. There was no correlation of metal implant wear or titanium plasma values to the duration of MCGR implantation time, number of external lengthening procedures, patient\u2019s ambulatory status, gender, weight or height. Material loss on the MCGRs showed a positive correlation to titanium blood plasma values. The present study is one of the first studies to analyze retrieved MCGRs using high-precision metrological techniques and compare these results with ICP-MS analyses determining blood titanium values.\n                  <\/jats:p>","DOI":"10.1038\/s41598-022-15057-1","type":"journal-article","created":{"date-parts":[[2022,6,25]],"date-time":"2022-06-25T06:30:39Z","timestamp":1656138639000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Titanium wear from magnetically controlled growing rods (MCGRs) for the treatment of spinal deformities in children"],"prefix":"10.1038","volume":"12","author":[{"given":"K. A.","family":"L\u00fcders","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Braunschweig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Zio\u0142a-Frankowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Stojek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Jakkielska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Wichmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. H.","family":"Dihazi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Streit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. E.","family":"G\u00fcsewell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. C.","family":"Tr\u00fce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"L\u00fcders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Schlie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Tsaknakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. M.","family":"Lorenz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Frankowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. K.","family":"Hell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,25]]},"reference":[{"key":"15057_CR1","doi-asserted-by":"publisher","first-page":"399","DOI":"10.2106\/00004623-200303000-00001","volume":"85-A","author":"RM Campbell","year":"2003","unstructured":"Campbell, R. M. et al. The characteristics of thoracic insufficiency syndrome associated with fused ribs and congenital scoliosis. J. Bone Joint Surg. Am. 85-A, 399\u2013408 (2003).","journal-title":"J. Bone Joint Surg. Am."},{"key":"15057_CR2","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1016\/S0140-6736(12)60112-3","volume":"379","author":"KM-C Cheung","year":"2012","unstructured":"Cheung, K.M.-C. et al. Magnetically controlled growing rods for severe spinal curvature in young children: A prospective case series. Lancet Lond. Engl. 379, 1967\u20131974 (2012).","journal-title":"Lancet Lond. Engl."},{"key":"15057_CR3","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1302\/2633-1462.17.BJO-2020-0099.R1","volume":"1","author":"A Abdelaal","year":"2020","unstructured":"Abdelaal, A., Munigangaiah, S., Trivedi, J. & Davidson, N. Magnetically controlled growing rods in the treatment of early onset scoliosis. Bone Jt. Open 1, 405\u2013414 (2020).","journal-title":"Bone Jt. Open"},{"key":"15057_CR4","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.OA.17.00036","volume":"2","author":"HM Lorenz","year":"2017","unstructured":"Lorenz, H. M. et al. Magnetically controlled devices parallel to the spine in children with spinal muscular atrophy. JB JS Open Access 2, e0036 (2017).","journal-title":"JB JS Open Access"},{"key":"15057_CR5","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1302\/0301-620X.100B9.BJJ-2018-0031.R2","volume":"100-B","author":"T Subramanian","year":"2018","unstructured":"Subramanian, T. et al. A six-year observational study of 31 children with early-onset scoliosis treated using magnetically controlled growing rods with a minimum follow-up of two years. Bone Jt. J. 100-B, 1187\u20131200 (2018).","journal-title":"Bone Jt. J."},{"key":"15057_CR6","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-018-5590-4","author":"C Thakar","year":"2018","unstructured":"Thakar, C. et al. Systematic review of the complications associated with magnetically controlled growing rods for the treatment of early onset scoliosis. Eur. Spine J. Off. Publ. Eur. Spine Soc. Eur. Spinal Deform. Soc. Eur. Sect. Cerv. Spine Res. Soc. https:\/\/doi.org\/10.1007\/s00586-018-5590-4 (2018).","journal-title":"Eur. Spine J. Off. Publ. Eur. Spine Soc. Eur. Spinal Deform. Soc. Eur. Sect. Cerv. Spine Res. Soc."},{"key":"15057_CR7","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.jspd.2017.06.005","volume":"6","author":"C Yilgor","year":"2018","unstructured":"Yilgor, C. et al. Metal ion release during growth-friendly instrumentation for early-onset scoliosis: A preliminary study. Spine Deform. 6, 48\u201353 (2018).","journal-title":"Spine Deform."},{"key":"15057_CR8","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.1097\/BRS.0000000000002221","volume":"43","author":"TJ Joyce","year":"2018","unstructured":"Joyce, T. J., Smith, S. L., Rushton, P. R. P., Bowey, A. J. & Gibson, M. J. Analysis of explanted magnetically controlled growing rods from seven UK spinal centers. Spine 43, E16-22 (2018).","journal-title":"Spine"},{"key":"15057_CR9","doi-asserted-by":"publisher","first-page":"2393","DOI":"10.1007\/s00586-014-3279-x","volume":"23","author":"TP Cundy","year":"2014","unstructured":"Cundy, T. P. et al. Serum titanium, niobium and aluminium levels two years following instrumented spinal fusion in children: Does implant surface area predict serum metal ion levels?. Eur. Spine J. Off. Publ. Eur. Spine Soc. Eur. Spinal Deform. Soc. Eur. Sect. Cerv. Spine Res. Soc. 23, 2393\u20132400 (2014).","journal-title":"Eur. Spine J. Off. Publ. Eur. Spine Soc. Eur. Spinal Deform. Soc. Eur. Sect. Cerv. Spine Res. Soc."},{"key":"15057_CR10","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.spinee.2015.11.040","volume":"16","author":"E Lukina","year":"2016","unstructured":"Lukina, E. et al. Metal concentrations in the blood and tissues after implantation of titanium growth guidance sliding instrumentation. Spine J. Off. J. North Am. Spine Soc. 16, 380\u2013388 (2016).","journal-title":"Spine J. Off. J. North Am. Spine Soc."},{"key":"15057_CR11","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1302\/0301-620X.102B10.BJJ-2020-0842.R1","volume":"102-B","author":"T Zhang","year":"2020","unstructured":"Zhang, T. et al. Systematic investigation of metallosis associated with magnetically controlled growing rod implantation for early-onset scoliosis. Bone Jt. J. 102-B, 1375\u20131383 (2020).","journal-title":"Bone Jt. J."},{"key":"15057_CR12","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/S1529-9430(02)00443-6","volume":"3","author":"BW Cunningham","year":"2003","unstructured":"Cunningham, B. W. et al. The effect of spinal instrumentation particulate wear debris. An in vivo rabbit model and applied clinical study of retrieved instrumentation cases. Spine. J. Off. J. North Am. Spine Soc. 3, 19\u201332 (2003).","journal-title":"J. Off. J. North Am. Spine Soc."},{"key":"15057_CR13","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1002\/(SICI)1097-4636(2000)53:3<193::AID-JBM1>3.0.CO;2-3","volume":"53","author":"Y Mochida","year":"2000","unstructured":"Mochida, Y., Bauer, T. W., Nitto, H., Kambic, H. E. & Muschler, G. F. Influence of stability and mechanical properties of a spinal fixation device on production of wear debris particles in vivo. J. Biomed. Mater. Res. 53, 193\u2013198 (2000).","journal-title":"J. Biomed. Mater. Res."},{"key":"15057_CR14","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s10856-007-3002-0","volume":"19","author":"JC Rubio","year":"2008","unstructured":"Rubio, J. C. et al. Determination of metallic traces in kidneys, livers, lungs and spleens of rats with metallic implants after a long implantation time. J. Mater. Sci. Mater. Med. 19, 369\u2013375 (2008).","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"15057_CR15","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1038\/sj.bjc.6600758","volume":"88","author":"N Coen","year":"2003","unstructured":"Coen, N., Kadhim, M. A., Wright, E. G., Case, C. P. & Mothersill, C. E. Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells. Br. J. Cancer 88, 548\u2013552 (2003).","journal-title":"Br. J. Cancer"},{"key":"15057_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-020-03543-4","volume":"21","author":"JZ Wei","year":"2020","unstructured":"Wei, J. Z. et al. Mechanical wear analysis helps understand a mechanism of failure in retrieved magnetically controlled growing rods: A retrieval study. BMC Musculoskelet. Disord. 21, 1\u201311 (2020).","journal-title":"BMC Musculoskelet. Disord."},{"key":"15057_CR17","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1007\/s00586-016-4936-z","volume":"26","author":"VC Panagiotopoulou","year":"2017","unstructured":"Panagiotopoulou, V. C. et al. Analysing a mechanism of failure in retrieved magnetically controlled spinal rods. Eur. Spine J. 26, 1699\u20131710 (2017).","journal-title":"Eur. Spine J."},{"key":"15057_CR18","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1302\/0301-620X.98B12.38061","volume":"98-B","author":"KH Teoh","year":"2016","unstructured":"Teoh, K. H. et al. Metallosis following implantation of magnetically controlled growing rods in the treatment of scoliosis: A case series. Bone Jt. J. 98-B, 1662\u20131667 (2016).","journal-title":"Bone Jt. J."},{"key":"15057_CR19","doi-asserted-by":"publisher","first-page":"e420","DOI":"10.1097\/BPO.0000000000001463","volume":"40","author":"Y Li","year":"2020","unstructured":"Li, Y., Graham, C. K., Robbins, C., Caird, M. S. & Farley, F. A. Elevated serum titanium levels in children with early onset scoliosis treated with growth-friendly instrumentation. J. Pediatr. Orthop. 40, e420\u2013e423 (2020).","journal-title":"J. Pediatr. Orthop."},{"key":"15057_CR20","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1007\/s43390-021-00335-1","volume":"9","author":"MD Borde","year":"2021","unstructured":"Borde, M. D., Sapare, S., Schutgens, E., Ali, C. & Noordeen, H. Analysis of serum levels of titanium and aluminium ions in patients with early onset scoliosis operated upon using the magnetic growing rod\u2014A single centre study of 14 patients. Spine Deform. 9, 1473\u20131478 (2021).","journal-title":"Spine Deform."},{"key":"15057_CR21","doi-asserted-by":"publisher","first-page":"2242","DOI":"10.1021\/es204168d","volume":"46","author":"A Weir","year":"2012","unstructured":"Weir, A., Westerhoff, P., Fabricius, L., Hristovski, K. & von Goetz, N. Titanium dioxide nanoparticles in food and personal care products. Environ. Sci. Technol. 46, 2242\u20132250 (2012).","journal-title":"Environ. Sci. Technol."},{"key":"15057_CR22","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.jtemb.2019.02.013","volume":"53","author":"I Swiatkowska","year":"2019","unstructured":"Swiatkowska, I., Martin, N. & Hart, A. J. Blood titanium level as a biomarker of orthopaedic implant wear. J. Trace Elem. Med. Biol. Organ Soc. Miner. Trace Elem. GMS 53, 120\u2013128 (2019).","journal-title":"J. Trace Elem. Med. Biol. Organ Soc. Miner. Trace Elem. GMS"},{"key":"15057_CR23","doi-asserted-by":"publisher","first-page":"5520","DOI":"10.1039\/C8AN00824H","volume":"143","author":"D Koller","year":"2018","unstructured":"Koller, D. et al. Analysis of soluble or titanium dioxide derived titanium levels in human whole blood: Consensus from an inter-laboratory comparison. Analyst 143, 5520\u20135529 (2018).","journal-title":"Analyst"},{"key":"15057_CR24","doi-asserted-by":"publisher","first-page":"e768","DOI":"10.3928\/01477447-20160503-02","volume":"39","author":"IP McAlister","year":"2016","unstructured":"McAlister, I. P. & Abdel, M. P. Elevated serum titanium level as a marker for failure in a titanium modular fluted tapered stem. Orthopedics 39, e768\u2013e770 (2016).","journal-title":"Orthopedics"},{"key":"15057_CR25","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1620\/tjem.185.253","volume":"185","author":"TK Liu","year":"1998","unstructured":"Liu, T. K., Liu, S. H., Chang, C. H. & Yang, R. S. Concentration of metal elements in the blood and urine in the patients with cementless total knee arthroplasty. Tohoku J. Exp. Med. 185, 253\u2013262 (1998).","journal-title":"Tohoku J. Exp. Med."},{"key":"15057_CR26","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.arth.2004.09.019","volume":"19","author":"JJ Jacobs","year":"2004","unstructured":"Jacobs, J. J. et al. Can metal levels be used to monitor metal-on-metal hip arthroplasties?. J. Arthroplasty 19, 59\u201365 (2004).","journal-title":"J. Arthroplasty"},{"key":"15057_CR27","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1258\/acb.2011.011141","volume":"49","author":"B Sampson","year":"2012","unstructured":"Sampson, B. & Hart, A. Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants. Ann. Clin. Biochem. Int. J. Lab. Med. 49, 118\u2013131 (2012).","journal-title":"Ann. Clin. Biochem. Int. J. Lab. Med."},{"issue":"Suppl 4","key":"15057_CR28","doi-asserted-by":"publisher","first-page":"202","DOI":"10.2106\/JBJS.H.00672","volume":"90","author":"K De Smet","year":"2008","unstructured":"De Smet, K. et al. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J. Bone Jt. Surg. 90(Suppl 4), 202\u2013208 (2008).","journal-title":"J. Bone Jt. Surg."},{"key":"15057_CR29","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1302\/0301-620X.93B10.26249","volume":"93-B","author":"AJ Hart","year":"2011","unstructured":"Hart, A. J. et al. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J. Bone Joint Surg. Br. 93-B, 1308\u20131313 (2011).","journal-title":"J. Bone Joint Surg. Br."},{"key":"15057_CR30","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.jtemb.2019.09.005","volume":"57","author":"I Swiatkowska","year":"2020","unstructured":"Swiatkowska, I. et al. Blood and plasma titanium levels associated with well-functioning hip implants. J. Trace Elem. Med. Biol. 57, 9\u201317 (2020).","journal-title":"J. Trace Elem. Med. Biol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15057-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15057-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15057-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T00:56:09Z","timestamp":1669337769000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15057-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,25]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["15057"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-15057-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,25]]},"assertion":[{"value":"4 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All authors declare to have no conflict of interest. Parts of the measuring time at Mahr GmbH were funded by BMBF funds of UMG.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10811"}}