{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T00:04:23Z","timestamp":1772841863016,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,4]],"date-time":"2022-07-04T00:00:00Z","timestamp":1656892800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,4]],"date-time":"2022-07-04T00:00:00Z","timestamp":1656892800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Chang Gung Memorial Hospital Research Grants","award":["CMRPG3L0151"],"award-info":[{"award-number":["CMRPG3L0151"]}]},{"name":"Ministry of Science and Technology Research Grant","award":["MOST 109-2314-B-182A-019-MY3"],"award-info":[{"award-number":["MOST 109-2314-B-182A-019-MY3"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The risks of misdiagnosing a healthy individual as glaucomatous or vice versa may be high in a population with a large majority of highly myopic individuals, due to considerable morphologic variability in high myopic fundus. This study aims to compare the diagnostic ability of the regular and long axial length databases in the RS-3000 Advance SD-OCT (Nidek) device to correctly diagnose glaucoma with high myopia. Patients with high myopia (axial length\u2009\u2265\u200926.0\u00a0mm) in Chang Gung Memorial Hospital, Taiwan between 2015 and 2020 were included. Glaucoma was diagnosed based on glaucomatous discs, visual field defects and corresponding retinal nerve fiber layer defects. The sensitivity, specificity, diagnostic accuracy and likelihood ratios of diagnosing glaucoma via mGCC thickness in both superior\/inferior and GChart mapping using the regular and long axial length normative databases. The specificity and diagnostic accuracy of mGCC thickness for distinguishing glaucomatous eyes from nonglaucomatous eyes among highly myopic eyes were significantly improved using the long axial length database (p\u2009=\u20090.046). There were also significant proportion changes in S\/I mapping as well as GChart mapping (37.3% and 48.0%, respectively; p\u2009&lt;\u20090.01) from abnormal to normal in the myopic normal eye group when using the long axial length normative database. The study revealed that clinicians could utilize a long axial length database to effectively decrease the number of false-positive diagnoses or to correctly identify highly myopic normal eyes misdiagnosed as glaucomatous eyes.<\/jats:p>","DOI":"10.1038\/s41598-022-15255-x","type":"journal-article","created":{"date-parts":[[2022,7,4]],"date-time":"2022-07-04T14:04:59Z","timestamp":1656943499000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Glaucoma diagnostic performance of macular ganglion cell complex thickness using regular and long axial length normative databases"],"prefix":"10.1038","volume":"12","author":[{"given":"Henry Shen-Lih","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiao Chun","family":"Ling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Wen","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lan-Hsing","family":"Chuang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Wen","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yung-Sung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Chi","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Po-Han","family":"Yeh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,4]]},"reference":[{"key":"15255_CR1","first-page":"13","volume":"32","author":"JJ Ha","year":"2019","unstructured":"Ha, J. J. & He, M. Preventing myopia in East Asia. Community Eye Health 32, 13\u201314 (2019).","journal-title":"Community Eye Health"},{"key":"15255_CR2","doi-asserted-by":"publisher","first-page":"2010","DOI":"10.1016\/s0161-6420(99)90416-5","volume":"106","author":"P Mitchell","year":"1999","unstructured":"Mitchell, P., Hourihan, F., Sandbach, J. & Wang, J. J. The relationship between glaucoma and myopia: The Blue Mountains Eye Study. Ophthalmology 106, 2010\u20132015. https:\/\/doi.org\/10.1016\/s0161-6420(99)90416-5 (1999).","journal-title":"Ophthalmology"},{"key":"15255_CR3","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.ophtha.2015.07.002","volume":"123","author":"L Shen","year":"2016","unstructured":"Shen, L. et al. The association of refractive error with glaucoma in a multiethnic population. Ophthalmology 123, 92\u2013101. https:\/\/doi.org\/10.1016\/j.ophtha.2015.07.002 (2016).","journal-title":"Ophthalmology"},{"key":"15255_CR4","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.ophtha.2006.06.050","volume":"114","author":"L Xu","year":"2007","unstructured":"Xu, L., Wang, Y., Wang, S., Wang, Y. & Jonas, J. B. High myopia and glaucoma susceptibility the Beijing Eye Study. Ophthalmology 114, 216\u2013220. https:\/\/doi.org\/10.1016\/j.ophtha.2006.06.050 (2007).","journal-title":"Ophthalmology"},{"key":"15255_CR5","doi-asserted-by":"publisher","first-page":"3158","DOI":"10.1167\/iovs.16-20860","volume":"58","author":"WL Marsh-Tootle","year":"2017","unstructured":"Marsh-Tootle, W. L. et al. Optic nerve tilt, crescent, ovality, and torsion in a multi-ethnic cohort of young adults with and without myopia. Invest. Ophthalmol. Vis. Sci. 58, 3158\u20133171. https:\/\/doi.org\/10.1167\/iovs.16-20860 (2017).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"15255_CR6","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.ajo.2004.08.076","volume":"139","author":"E Tay","year":"2005","unstructured":"Tay, E. et al. Optic disk ovality as an index of tilt and its relationship to myopia and perimetry. Am. J. Ophthalmol. 139, 247\u2013252. https:\/\/doi.org\/10.1016\/j.ajo.2004.08.076 (2005).","journal-title":"Am. J. Ophthalmol."},{"key":"15255_CR7","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1111\/j.1475-1313.2005.00298.x","volume":"25","author":"SM Saw","year":"2005","unstructured":"Saw, S. M., Gazzard, G., Shih-Yen, E. C. & Chua, W. H. Myopia and associated pathological complications. Ophthalmic Physiol. Opt. 25, 381\u2013391. https:\/\/doi.org\/10.1111\/j.1475-1313.2005.00298.x (2005).","journal-title":"Ophthalmic Physiol. Opt."},{"key":"15255_CR8","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1016\/j.ophtha.2017.12.005","volume":"125","author":"Y Fang","year":"2018","unstructured":"Fang, Y. et al. Progression of myopic maculopathy during 18-year follow-up. Ophthalmology 125, 863\u2013877. https:\/\/doi.org\/10.1016\/j.ophtha.2017.12.005 (2018).","journal-title":"Ophthalmology"},{"key":"15255_CR9","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1167\/iovs.06-0426","volume":"48","author":"DS Lam","year":"2007","unstructured":"Lam, D. S. et al. Regional variations in the relationship between macular thickness measurements and myopia. Invest. Ophthalmol. Vis. Sci. 48, 376\u2013382. https:\/\/doi.org\/10.1167\/iovs.06-0426 (2007).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"15255_CR10","doi-asserted-by":"publisher","first-page":"2012","DOI":"10.1167\/iovs.04-0335","volume":"46","author":"H Ishikawa","year":"2005","unstructured":"Ishikawa, H. et al. Macular segmentation with optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 46, 2012\u20132017. https:\/\/doi.org\/10.1167\/iovs.04-0335 (2005).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"15255_CR11","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1016\/j.ophtha.2007.08.011","volume":"115","author":"O Tan","year":"2008","unstructured":"Tan, O. et al. Mapping of macular substructures with optical coherence tomography for glaucoma diagnosis. Ophthalmology 115, 949\u2013956. https:\/\/doi.org\/10.1016\/j.ophtha.2007.08.011 (2008).","journal-title":"Ophthalmology"},{"key":"15255_CR12","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1097\/IJG.0b013e3181ca7acf","volume":"19","author":"S Mori","year":"2010","unstructured":"Mori, S., Hangai, M., Sakamoto, A. & Yoshimura, N. Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J. Glaucoma 19, 528\u2013534. https:\/\/doi.org\/10.1097\/IJG.0b013e3181ca7acf (2010).","journal-title":"J. Glaucoma"},{"key":"15255_CR13","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1136\/bjo.2010.182493","volume":"95","author":"NR Kim","year":"2011","unstructured":"Kim, N. R. et al. Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br. J. Ophthalmol. 95, 1115\u20131121. https:\/\/doi.org\/10.1136\/bjo.2010.182493 (2011).","journal-title":"Br. J. Ophthalmol."},{"key":"15255_CR14","doi-asserted-by":"publisher","first-page":"2296","DOI":"10.1167\/iovs.12-10530","volume":"54","author":"YJ Choi","year":"2013","unstructured":"Choi, Y. J., Jeoung, J. W., Park, K. H. & Kim, D. M. Glaucoma detection ability of ganglion cell-inner plexiform layer thickness by spectral-domain optical coherence tomography in high myopia. Invest. Ophthalmol. Vis. Sci. 54, 2296\u20132304. https:\/\/doi.org\/10.1167\/iovs.12-10530 (2013).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"15255_CR15","doi-asserted-by":"publisher","first-page":"7494","DOI":"10.1167\/iovs.14-14043","volume":"55","author":"T Rock","year":"2014","unstructured":"Rock, T., Bartz-Schmidt, K. U., Bramkamp, M. & Rock, D. Influence of axial length on thickness measurements using spectral-domain optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 55, 7494\u20137498. https:\/\/doi.org\/10.1167\/iovs.14-14043 (2014).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"15255_CR16","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s10792-015-0119-x","volume":"36","author":"J Choovuthayakorn","year":"2016","unstructured":"Choovuthayakorn, J., Laowong, T., Watanachai, N., Patikulsila, D. & Chaikitmongkol, V. Spectral-domain optical coherence tomography of macula in myopia. Int. Ophthalmol. 36, 319\u2013325. https:\/\/doi.org\/10.1007\/s10792-015-0119-x (2016).","journal-title":"Int. Ophthalmol."},{"key":"15255_CR17","unstructured":"Nidek Reference material for the RS-3000 Normative database. NDB Clinical Report 1-071210. Nidek. Co., Ltd. Accessed 22 June 2020."},{"key":"15255_CR18","unstructured":"Fechtner R Review of Normative Database Construction in Available OCT Models. U.S.FDA web site. http:\/\/www.fda.gov\/downloads\/MedicalDevices\/NewsEvents\/WorkshopsConferences\/UCM326697.pdf. Accessed 22 June 2020."},{"key":"15255_CR19","unstructured":"Nidek. Reference material for the RS-3000 long axial length normative database. Long Axial Length NDB Clinical Report-060914. Nidek. Co., Ltd. Accessed 22 June 2020."},{"key":"15255_CR20","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.tjo.2016.01.001","volume":"6","author":"HS Chen","year":"2016","unstructured":"Chen, H. S., Liu, C. H. & Lu, D. W. Comparison of glaucoma diagnostic accuracy of macular ganglion cell complex thickness based on nonhighly myopic and highly myopic normative database. Taiwan J. Ophthalmol. 6, 15\u201320. https:\/\/doi.org\/10.1016\/j.tjo.2016.01.001 (2016).","journal-title":"Taiwan J. Ophthalmol."},{"key":"15255_CR21","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/BF00175988","volume":"232","author":"AG Bennett","year":"1994","unstructured":"Bennett, A. G., Rudnicka, A. R. & Edgar, D. F. Improvements on Littmann\u2019s method of determining the size of retinal features by fundus photography. Graefes Arch. Clin. Exp. Ophthalmol. 232, 361\u2013367. https:\/\/doi.org\/10.1007\/BF00175988 (1994).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"15255_CR22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0138825","volume":"10","author":"N Nagaoka","year":"2015","unstructured":"Nagaoka, N. et al. Glaucomatous-type optic discs in high myopia. PLoS ONE 10, e0138825. https:\/\/doi.org\/10.1371\/journal.pone.0138825 (2015).","journal-title":"PLoS ONE"},{"key":"15255_CR23","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/j.ophtha.2006.07.036","volume":"114","author":"A Doshi","year":"2007","unstructured":"Doshi, A., Kreidl, K. O., Lombardi, L., Sakamoto, D. K. & Singh, K. Nonprogressive glaucomatous cupping and visual field abnormalities in young Chinese males. Ophthalmology 114, 472\u2013479. https:\/\/doi.org\/10.1016\/j.ophtha.2006.07.036 (2007).","journal-title":"Ophthalmology"},{"key":"15255_CR24","doi-asserted-by":"publisher","first-page":"3485","DOI":"10.1038\/s41598-019-38960-6","volume":"9","author":"HL Park","year":"2019","unstructured":"Park, H. L., Kim, Y. C., Jung, Y. & Park, C. K. Vertical disc tilt and features of the optic nerve head anatomy are related to visual field defect in myopic eyes. Sci Rep 9, 3485. https:\/\/doi.org\/10.1038\/s41598-019-38960-6 (2019).","journal-title":"Sci Rep"},{"key":"15255_CR25","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.ophtha.2016.01.052","volume":"123","author":"R Malik","year":"2016","unstructured":"Malik, R. et al. Diagnostic accuracy of optical coherence tomography and scanning laser tomography for identifying glaucoma in myopic eyes. Ophthalmology 123, 1181\u20131189. https:\/\/doi.org\/10.1016\/j.ophtha.2016.01.052 (2016).","journal-title":"Ophthalmology"},{"key":"15255_CR26","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1007\/s00417-015-3026-y","volume":"253","author":"H Nakanishi","year":"2015","unstructured":"Nakanishi, H. et al. Sensitivity and specificity for detecting early glaucoma in eyes with high myopia from normative database of macular ganglion cell complex thickness obtained from normal non-myopic or highly myopic Asian eyes. Graefes Arch. Clin. Exp. Ophthalmol. 253, 1143\u20131152. https:\/\/doi.org\/10.1007\/s00417-015-3026-y (2015).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"15255_CR27","doi-asserted-by":"publisher","first-page":"e481","DOI":"10.1097\/IJG.0000000000000330","volume":"25","author":"H Nakanishi","year":"2016","unstructured":"Nakanishi, H. et al. Effect of axial length on macular ganglion cell complex thickness and on early glaucoma diagnosis by spectral-domain optical coherence tomography. J. Glaucoma 25, e481-490. https:\/\/doi.org\/10.1097\/IJG.0000000000000330 (2016).","journal-title":"J. Glaucoma"},{"key":"15255_CR28","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ajo.2017.09.010","volume":"183","author":"BR Seol","year":"2017","unstructured":"Seol, B. R., Kim, D. M., Park, K. H. & Jeoung, J. W. Assessment of optical coherence tomography color probability codes in myopic glaucoma eyes after applying a myopic normative database. Am. J. Ophthalmol. 183, 147\u2013155. https:\/\/doi.org\/10.1016\/j.ajo.2017.09.010 (2017).","journal-title":"Am. J. Ophthalmol."},{"key":"15255_CR29","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1001\/jamaophthalmol.2016.2343","volume":"134","author":"S Biswas","year":"2016","unstructured":"Biswas, S., Lin, C. & Leung, C. K. Evaluation of a myopic normative database for analysis of retinal nerve fiber layer thickness. JAMA Ophthalmol. 134, 1032\u20131039. https:\/\/doi.org\/10.1001\/jamaophthalmol.2016.2343 (2016).","journal-title":"JAMA Ophthalmol."},{"key":"15255_CR30","doi-asserted-by":"publisher","first-page":"3655","DOI":"10.1167\/iovs.18-24283","volume":"59","author":"YW Kim","year":"2018","unstructured":"Kim, Y. W. & Park, K. H. Diagnostic accuracy of three-dimensional neuroretinal rim thickness for differentiation of myopic glaucoma from myopia. Invest. Ophthalmol. Vis. Sci. 59, 3655\u20133666. https:\/\/doi.org\/10.1167\/iovs.18-24283 (2018).","journal-title":"Invest. Ophthalmol. Vis. Sci."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15255-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15255-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15255-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T06:04:50Z","timestamp":1669356290000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-15255-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,4]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["15255"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-15255-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,4]]},"assertion":[{"value":"2 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11263"}}