{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T18:03:17Z","timestamp":1794852197240,"version":"4.9.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinik M\u00fcnchen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To determine protrusion assessment via Hertel exophthalmometry in comparison to measurement on Computed Tomography (CT). Retrospective blinded comparison of exophthalmos measurements on axial CT with Hertel exophthalmometry measurements in 113 patients. Descriptive statistics, Pearson\u2019s correlation, Kruskal\u2013Wallis and Mann\u2013Whitney-U test were employed for analysis. Mean difference of proptosis between both eyes was 2.4 (SD\u2009\u00b1\u20092.0)\u00a0mm in CT and 2.2 (SD\u2009\u00b1\u20092.0)\u00a0mm in Hertel measurements. Proptosis of 0\u20132\u00a0mm was present in 69 (61.1%), and\u2009&gt;\u20092\u00a0mm in 42 (38.9%) patients in Hertel measurements (CT 64 (56.6%), and 49 (43.4%) patients). Pearson\u2019s coefficient showed a correlation of 0.793 between both methods (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Accuracy of Hertel measurement depended significantly from the examiners\u2019 experience (&lt;\u20095 (group 1), 5\u201315 (2) and\u2009&gt;\u200925 (3) years, <jats:italic>p<\/jats:italic>\u2009=\u20090.042, Kruskal\u2013Wallis analysis; <jats:italic>p<\/jats:italic>\u2009=\u20090.086 group 1 vs. 2, <jats:italic>p<\/jats:italic>\u2009=\u20090.014 group 1 vs. 3, <jats:italic>p<\/jats:italic>\u2009=\u20090.688 group 2 vs. 3, Mann\u2013Whitney-U-test), reflected by levels of Pearson\u2019s coefficient (correlation of both methods 0.691 (group 1), 0.837 (2) and 0.831 (3), respectively, <jats:italic>p<\/jats:italic>\u2009=\u20090.01). Generally, Hertel exophthalmometry correlates well with CT measurements. Subgroup analysis confirmed a superior quality of Hertel measurements in favour of experienced examiners. Teaching of accurate Hertel exophthalmometry should be improved. Assessment of exophthalmos using standardized criteria should be implemented for imaging reports.<\/jats:p>","DOI":"10.1038\/s41598-022-16131-4","type":"journal-article","created":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T22:05:04Z","timestamp":1657749904000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Cross-sectional computed tomography assessment of exophthalmos in comparison to clinical measurement via Hertel exophthalmometry"],"prefix":"10.1038","volume":"12","author":[{"given":"A.","family":"Klingenstein","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Samel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Garip-K\u00fcbler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Hintschich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U. G.","family":"M\u00fcller-Lisse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,13]]},"reference":[{"key":"16131_CR1","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/S0002-9394(02)01429-0","volume":"133","author":"M Segni","year":"2002","unstructured":"Segni, M., Bartley, G. B., Garrity, J. A., Bergstralh, E. J. & Gorman, C. A. Comparability of proptosis measurements by different techniques. Am. J. Ophthalmol. 133, 813\u2013818 (2002).","journal-title":"Am. J. Ophthalmol."},{"key":"16131_CR2","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1097\/01.IOP.0000143712.42344.8C","volume":"20","author":"H Ameri","year":"2004","unstructured":"Ameri, H. & Fenton, S. Comparison of unilateral and simultaneous bilateral measurement of the globe position, using the Hertel exophthalmometer. Ophthal. Plast. Reconstr. Surg. 20, 448\u2013451 (2004).","journal-title":"Ophthal. Plast. Reconstr. Surg."},{"key":"16131_CR3","first-page":"496","volume":"1004","author":"W Hassler","year":"2007","unstructured":"Hassler, W., Uns\u00f6ld, R. & Schick, U. Orbital tumors\u2014Diagnosis and surgical treatment. Dtsch. \u00c4rztebl. 1004, 496\u2013501 (2007).","journal-title":"Dtsch. \u00c4rztebl."},{"key":"16131_CR4","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1475-1313.2008.00617.x","volume":"29","author":"AK Lam","year":"2009","unstructured":"Lam, A. K., Lam, C. F., Leung, W. K. & Hung, P. K. Intra-observer and interobserver variation of Hertel exophthalmometry. Ophthalmic Physiol. Opt. 29, 472\u2013476 (2009).","journal-title":"Ophthalmic Physiol. Opt."},{"key":"16131_CR5","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1001\/archinte.1980.00330200106028","volume":"140","author":"E de Juan","year":"1980","unstructured":"de Juan, E., Hurley, D. P. & Sapira, J. D. Racial differences in normal values of proptosis. Arch. Intern. Med. 140, 1230\u20131231 (1980).","journal-title":"Arch. Intern. Med."},{"key":"16131_CR6","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1055\/s-0042-121809","volume":"234","author":"A Klingenstein","year":"2017","unstructured":"Klingenstein, A. & Hintschich, C. Diagnostic management of exophthalmos. Klin Monatsbl Augenheilk. 234, 53\u201358 (2017).","journal-title":"Klin Monatsbl Augenheilk."},{"key":"16131_CR7","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1076\/orbi.22.4.239.17245","volume":"22","author":"MB Kashkouli","year":"2003","unstructured":"Kashkouli, M. B., Beigi, B. & Noorani, M. M. Hertel exophthalmometry: Reliability and interobserver variation. Orbit 22, 239\u2013245 (2003).","journal-title":"Orbit"},{"key":"16131_CR8","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1080\/01676830490504089","volume":"23","author":"MP Mourits","year":"2004","unstructured":"Mourits, M. P., Lombardo, S. H., van der Sluijs, F. A. & Fenton, S. Reliability of exophthalmos measurement and the exophthalmometry value distribution in a healthy Dutch population and in Graves patients. An exploratory study. Orbit 23, 161\u2013168 (2004).","journal-title":"Orbit"},{"key":"16131_CR9","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1097\/00002341-200207000-00004","volume":"18","author":"TJ Sleep","year":"2002","unstructured":"Sleep, T. J. & Manners, R. M. Interinstrument variability in Hertel-type exophthalmometers. Ophthal. Plast. Reconstr. Surg. 18, 254\u2013257 (2002).","journal-title":"Ophthal. Plast. Reconstr. Surg."},{"key":"16131_CR10","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/01.iop.0000180066.87572.39","volume":"21","author":"Y Vardizer","year":"2005","unstructured":"Vardizer, Y., Berendschot, T. T. & Mourits, M. P. Effect of exophthalmometer design on its accuracy. Ophthal. Plast. Reconstr. Surg. 21, 427\u2013430 (2005).","journal-title":"Ophthal. Plast. Reconstr. Surg."},{"key":"16131_CR11","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.2147\/OPTH.S216838","volume":"13","author":"NR Park","year":"2019","unstructured":"Park, N. R., Moon, J. H. & Lee, J. K. Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy. Clin. Ophthalmol. 13, 1461\u20131467 (2019).","journal-title":"Clin. Ophthalmol."},{"key":"16131_CR12","first-page":"146","volume":"6","author":"ZJ Fang","year":"2013","unstructured":"Fang, Z. J., Zhang, J. Y. & He, W. M. CT features of exophthalmos in Chinese subjects with thyroid-associated ophthalmopathy. Int. J. Ophthalmol. 6, 146\u2013149 (2013).","journal-title":"Int. J. Ophthalmol."},{"key":"16131_CR13","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.jcms.2003.07.001","volume":"31","author":"E Nkenke","year":"2003","unstructured":"Nkenke, E. et al. Relative en- and exophthalmometry in zygomatic fractures comparing optical non-contact, non-ionizing 3D imaging to the Hertel instrument and computed tomography. J. Craniomaxillofac. Surg. 31, 362\u2013368 (2003).","journal-title":"J. Craniomaxillofac. Surg."},{"key":"16131_CR14","doi-asserted-by":"publisher","first-page":"257","DOI":"10.3109\/01676830.2015.1057291","volume":"34","author":"N Ramli","year":"2015","unstructured":"Ramli, N., Kala, S., Samsudin, A., Rahmat, K. & Abidin, Z. Z. Proptosis\u2014Correlation and agreement between Hertel exophthalmometry and computed tomography. Orbit 34, 257\u2013262 (2015).","journal-title":"Orbit"},{"key":"16131_CR15","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1080\/02713683.2018.1431285","volume":"43","author":"J Guo","year":"2018","unstructured":"Guo, J., Qian, J. & Yuan, Y. Computed tomography measurements as a standard of exophthalmos? Two-dimensional versus three-dimensional techniques. Curr. Eye Res. 43, 647\u2013653 (2018).","journal-title":"Curr. Eye Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16131-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16131-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16131-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T04:18:38Z","timestamp":1669349918000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16131-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,13]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["16131"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-16131-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,13]]},"assertion":[{"value":"28 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11973"}}