{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T00:08:32Z","timestamp":1773965312061,"version":"3.50.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,23]],"date-time":"2022-07-23T00:00:00Z","timestamp":1658534400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,23]],"date-time":"2022-07-23T00:00:00Z","timestamp":1658534400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["17CPRE33650059"],"award-info":[{"award-number":["17CPRE33650059"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["19TPA34910176"],"award-info":[{"award-number":["19TPA34910176"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["1F30HL13728801A1"],"award-info":[{"award-number":["1F30HL13728801A1"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The aim\u00a0of this study was to validate a motion-immune (MI) solution to dynamic CT myocardial perfusion measurement, in the presence of motion without image registration. The MI perfusion technique was retrospectively validated in six swine (37.3\u2009\u00b1\u20097.5\u00a0kg) with a motion-susceptible (MS) perfusion technique  performed for comparison. In each swine, varying severities of stenoses were generated in the left anterior descending (LAD) coronary artery using a balloon under intracoronary adenosine stress, followed by contrast-enhanced imaging with 20 consecutive volume scans per stenosis. Two volume scans were then systematically selected from each acquisition for both MI and MS perfusion measurement, where the resulting LAD and left circumflex (LCx) measurements were compared to reference microsphere perfusion measurements using regression and diagnostic performance analysis. The MI (P<jats:sub>MI<\/jats:sub>) and microsphere (P<jats:sub>MICRO<\/jats:sub>) perfusion measurements were related through regression by P<jats:sub>MI<\/jats:sub>\u2009=\u20090.98 P<jats:sub>MICRO<\/jats:sub>\u2009+\u20090.03 (r\u2009=\u20090.97), while the MS (P<jats:sub>MS<\/jats:sub>) and microsphere (P<jats:sub>MICRO<\/jats:sub>) perfusion measurements were related by P<jats:sub>MS<\/jats:sub>\u2009=\u20090.62 P<jats:sub>MICRO<\/jats:sub>\u2009+\u20090.15 (r\u2009=\u20090.89). The accuracy of the MI and MS techniques in detecting functionally significant stenosis was 93% and 84%, respectively. The motion-immune (MI) perfusion technique provides accurate myocardial perfusion measurement in the presence of motion without image registration.<\/jats:p>","DOI":"10.1038\/s41598-022-16573-w","type":"journal-article","created":{"date-parts":[[2022,7,23]],"date-time":"2022-07-23T09:13:03Z","timestamp":1658567583000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Dynamic CT myocardial perfusion without image registration"],"prefix":"10.1038","volume":"12","author":[{"given":"Logan","family":"Hubbard","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shant","family":"Malkasian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabee","family":"Molloi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,23]]},"reference":[{"key":"16573_CR1","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1056\/NEJMoa1415516","volume":"372","author":"PS Douglas","year":"2015","unstructured":"Douglas, P. S. et al. Outcomes of anatomical versus functional testing for coronary artery disease. N. Engl. J. Med. 372, 1291\u20131300. https:\/\/doi.org\/10.1056\/NEJMoa1415516 (2015).","journal-title":"N. Engl. J. Med."},{"key":"16573_CR2","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1161\/CIRCIMAGING.111.969303","volume":"5","author":"RT George","year":"2012","unstructured":"George, R. T. et al. Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease. Circ. Cardiovasc. Imaging 5, 333\u2013340. https:\/\/doi.org\/10.1161\/CIRCIMAGING.111.969303 (2012).","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"16573_CR3","doi-asserted-by":"publisher","first-page":"2816","DOI":"10.1016\/j.jacc.2009.11.096","volume":"55","author":"PAL Tonino","year":"2010","unstructured":"Tonino, P. A. L. et al. Angiographic versus functional severity of coronary artery stenoses in the FAME study: Fractional flow reserve versus angiography in multivessel evaluation. J. Am. Coll. Cardiol. 55, 2816\u20132821. https:\/\/doi.org\/10.1016\/j.jacc.2009.11.096 (2010).","journal-title":"J. Am. Coll. Cardiol."},{"key":"16573_CR4","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1093\/eurheartj\/ehl039","volume":"27","author":"J Rieber","year":"2006","unstructured":"Rieber, J. et al. Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease: A comparison with coronary angiography and fractional flow reserve. Eur. Heart J. 27, 1465\u20131471. https:\/\/doi.org\/10.1093\/eurheartj\/ehl039 (2006).","journal-title":"Eur. Heart J."},{"key":"16573_CR5","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1161\/circulationaha.113.002744","volume":"128","author":"R Doukky","year":"2013","unstructured":"Doukky, R. et al. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging. Circulation 128, 1634\u20131643. https:\/\/doi.org\/10.1161\/circulationaha.113.002744 (2013).","journal-title":"Circulation"},{"key":"16573_CR6","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1001\/jamacardio.2017.2471","volume":"2","author":"I Danad","year":"2017","unstructured":"Danad, I. et al. Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2, 1100\u20131107. https:\/\/doi.org\/10.1001\/jamacardio.2017.2471 (2017).","journal-title":"JAMA Cardiol."},{"key":"16573_CR7","doi-asserted-by":"publisher","first-page":"452","DOI":"10.21037\/cdt.2017.06.11","volume":"7","author":"KR Branch","year":"2017","unstructured":"Branch, K. R. et al. Myocardial computed tomography perfusion. Cardiovasc. Diagn. Ther. 7, 452\u2013462. https:\/\/doi.org\/10.21037\/cdt.2017.06.11 (2017).","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"16573_CR8","doi-asserted-by":"publisher","first-page":"7295460","DOI":"10.1155\/2018\/7295460","volume":"2018","author":"S Seitun","year":"2018","unstructured":"Seitun, S. et al. CT myocardial perfusion imaging: A new frontier in cardiac imaging. Biomed. Res. Int. 2018, 7295460. https:\/\/doi.org\/10.1155\/2018\/7295460 (2018).","journal-title":"Biomed. Res. Int."},{"key":"16573_CR9","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.jcct.2019.09.003","volume":"14","author":"K Nieman","year":"2020","unstructured":"Nieman, K. & Balla, S. Dynamic CT myocardial perfusion imaging. J. Cardiovasc. Comput. Tomogr. 14, 303\u2013306. https:\/\/doi.org\/10.1016\/j.jcct.2019.09.003 (2020).","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"16573_CR10","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1016\/j.jcmg.2017.10.010","volume":"11","author":"M Lubbers","year":"2018","unstructured":"Lubbers, M. et al. Comprehensive cardiac CT with myocardial perfusion imaging versus functional testing in suspected coronary artery disease: The multicenter randomized CRESCENT-II trial. JACC Cardiovasc. Imaging 11, 1625\u20131636. https:\/\/doi.org\/10.1016\/j.jcmg.2017.10.010 (2018).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"16573_CR11","doi-asserted-by":"publisher","first-page":"2460","DOI":"10.1016\/j.jcmg.2019.02.015","volume":"12","author":"G Pontone","year":"2019","unstructured":"Pontone, G. et al. Dynamic stress computed tomography perfusion with a whole-heart coverage scanner in addition to coronary computed tomography angiography and fractional flow reserve computed tomography derived. JACC Cardiovasc. Imaging 12, 2460\u20132471 (2019).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"16573_CR12","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.1093\/eurheartj\/eht488","volume":"35","author":"CE Rochitte","year":"2013","unstructured":"Rochitte, C. E. et al. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study. Eur. Heart J. 35, 1120\u20131130. https:\/\/doi.org\/10.1093\/eurheartj\/eht488 (2013).","journal-title":"Eur. Heart J."},{"key":"16573_CR13","doi-asserted-by":"publisher","first-page":"e005505","DOI":"10.1161\/CIRCIMAGING.116.005505","volume":"10","author":"A Rossi","year":"2017","unstructured":"Rossi, A. et al. Dynamic computed tomography myocardial perfusion imaging. Circ. Cardiovasc. Imaging 10, e005505. https:\/\/doi.org\/10.1161\/CIRCIMAGING.116.005505 (2017).","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"16573_CR14","doi-asserted-by":"publisher","first-page":"129","DOI":"10.21037\/cdt.2017.03.22","volume":"7","author":"F Cademartiri","year":"2017","unstructured":"Cademartiri, F. et al. Myocardial blood flow quantification for evaluation of coronary artery disease by computed tomography. Cardiovasc. Diagn. Ther. 7, 129\u2013150. https:\/\/doi.org\/10.21037\/cdt.2017.03.22 (2017).","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"16573_CR15","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1148\/radiol.2017162821","volume":"286","author":"L Hubbard","year":"2018","unstructured":"Hubbard, L. et al. Comprehensive assessment of coronary artery disease by using first-pass analysis dynamic CT perfusion: Validation in a swine model. Radiology 286, 93\u2013102. https:\/\/doi.org\/10.1148\/radiol.2017162821 (2018).","journal-title":"Radiology"},{"key":"16573_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1161\/circimaging.116.005325","volume":"9","author":"L Hubbard","year":"2016","unstructured":"Hubbard, L. et al. Functional assessment of coronary artery disease using whole-heart dynamic computed tomographic perfusion. Circ. Cardiovasc. Imaging 9, 1\u20138. https:\/\/doi.org\/10.1161\/circimaging.116.005325 (2016).","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"16573_CR17","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1097\/rli.0000000000000613","volume":"54","author":"L Hubbard","year":"2019","unstructured":"Hubbard, L. et al. Low-Radiation-dose stress myocardial perfusion measurement using first-pass analysis dynamic computed tomography: A preliminary investigation in a swine model. Invest. Radiol. 54, 774\u2013780. https:\/\/doi.org\/10.1097\/rli.0000000000000613 (2019).","journal-title":"Invest. Radiol."},{"key":"16573_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-020-02130-x","author":"L Hubbard","year":"2021","unstructured":"Hubbard, L., Malkasian, S., Zhao, Y., Abbona, P. & Molloi, S. Combining perfusion and angiography with a low-dose cardiac CT technique: A preliminary investigation in a swine model. Int. J. Cardiovasc. Imaging https:\/\/doi.org\/10.1007\/s10554-020-02130-x (2021).","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"16573_CR19","doi-asserted-by":"crossref","unstructured":"Boone, J. et al. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations: report of AAPM task group 204. College Park, MD: American Association of Physicists in Medicine (2011).","DOI":"10.37206\/143"},{"key":"16573_CR20","doi-asserted-by":"publisher","first-page":"2772","DOI":"10.1016\/j.jacc.2016.03.584","volume":"67","author":"NP Johnson","year":"2016","unstructured":"Johnson, N. P., Gould, K. L., Di Carli, M. F. & Taqueti, V. R. Invasive FFR and noninvasive CFR in the evaluation of ischemia: What is the future?. J. Am. Coll. Cardiol. 67, 2772\u20132788. https:\/\/doi.org\/10.1016\/j.jacc.2016.03.584 (2016).","journal-title":"J. Am. Coll. Cardiol."},{"key":"16573_CR21","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1002\/acm2.12246","volume":"19","author":"I Ali","year":"2018","unstructured":"Ali, I., Alsbou, N., Jaskowiak, J. & Ahmad, S. Quantitative evaluation of the performance of different deformable image registration algorithms in helical, axial, and cone-beam CT images using a mobile phantom. J. Appl. Clin. Med. Phys. 19, 62\u201373. https:\/\/doi.org\/10.1002\/acm2.12246 (2018).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"16573_CR22","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.ejmp.2020.02.016","volume":"71","author":"Y Huang","year":"2020","unstructured":"Huang, Y. et al. A quantitative evaluation of deformable image registration based on MV cone beam CT images: Impact of deformation magnitudes and image modalities. Phys. Med. 71, 82\u201387. https:\/\/doi.org\/10.1016\/j.ejmp.2020.02.016 (2020).","journal-title":"Phys. Med."},{"key":"16573_CR23","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1016\/j.jcmg.2013.05.018","volume":"6","author":"F Schwarz","year":"2013","unstructured":"Schwarz, F. et al. Myocardial CT perfusion imaging in a large animal model: Comparison of dynamic versus single-phase acquisitions. JACC Cardiovasc. Imaging 6, 1229\u20131238. https:\/\/doi.org\/10.1016\/j.jcmg.2013.05.018 (2013).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"16573_CR24","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1093\/ehjci\/jew044","volume":"17","author":"I Danad","year":"2016","unstructured":"Danad, I., Szymonifka, J., Schulman-Marcus, J. & Min, J. K. Static and dynamic assessment of myocardial perfusion by computed tomography. Eur. Heart J. Cardiovasc. Imaging 17, 836\u2013844. https:\/\/doi.org\/10.1093\/ehjci\/jew044 (2016).","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"16573_CR25","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.jcct.2012.02.008","volume":"6","author":"P Madaj","year":"2012","unstructured":"Madaj, P. & Budoff, M. J. Risk stratification of non-contrast CT beyond the coronary calcium scan. J. Cardiovasc. Comput. Tomogr. 6, 301\u2013307. https:\/\/doi.org\/10.1016\/j.jcct.2012.02.008 (2012).","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"16573_CR26","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.jcct.2014.10.004","volume":"9","author":"JW Nance Jr","year":"2015","unstructured":"Nance, J. W. Jr., Crane, G. M., Halushka, M. K., Fishman, E. K. & Zimmerman, S. L. Myocardial calcifications: Pathophysiology, etiologies, differential diagnoses, and imaging findings. J. Cardiovasc. Comput. Tomogr. 9, 58\u201367. https:\/\/doi.org\/10.1016\/j.jcct.2014.10.004 (2015).","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"16573_CR27","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1016\/j.jcmg.2011.12.014","volume":"5","author":"NP Johnson","year":"2012","unstructured":"Johnson, N. P. & Gould, K. L. Integrating noninvasive absolute flow, coronary flow reserve, and ischemic thresholds into a comprehensive map of physiological severity. JACC Cardiovasc. Imaging 5, 430\u2013440. https:\/\/doi.org\/10.1016\/j.jcmg.2011.12.014 (2012).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"16573_CR28","first-page":"1","volume":"2","author":"L Hubbard","year":"2018","unstructured":"Hubbard, L., Malkasian, S., Zhao, Y., Abbona, P. & Molloi, S. Contrast-to-noise ratio optimization in coronary computed tomography angiography: Validation in a swine model. Acad. Radiol. 2, 1\u201311 (2018).","journal-title":"Acad. Radiol."},{"issue":"16","key":"16573_CR29","first-page":"1","volume":"3","author":"L Hubbard","year":"2019","unstructured":"Hubbard, L., Malkasian, S., Zhao, Y., Abbona, P. & Molloi, S. Timing optimization of low-dose first-pass analysis dynamic CT myocardial perfusion measurment: Validation in a swine model. Eur. Radiol. Exp. 3(16), 1\u20139 (2019).","journal-title":"Eur. Radiol. Exp."},{"key":"16573_CR30","doi-asserted-by":"publisher","first-page":"439","DOI":"10.21037\/cdt.2017.06.07","volume":"7","author":"J-E Scholtz","year":"2017","unstructured":"Scholtz, J.-E. & Ghoshhajra, B. Advances in cardiac CT contrast injection and acquisition protocols. Cardiovasc. Diagn. Ther. 7, 439\u2013451. https:\/\/doi.org\/10.21037\/cdt.2017.06.07 (2017).","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"16573_CR31","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.jcct.2018.06.006","volume":"12","author":"S Malkasian","year":"2018","unstructured":"Malkasian, S., Hubbard, L., Dertli, B., Kwon, J. & Molloi, S. Quantification of vessel-specific coronary perfusion territories using minimum-cost path assignment and computed tomography angiography: Validation in a swine model. J. Cardiovasc. Comput. Tomogr. 12, 425\u2013435 (2018).","journal-title":"J. Cardiovasc. Comput. Tomogr."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16573-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16573-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16573-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T04:22:52Z","timestamp":1669350172000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16573-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,23]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["16573"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-16573-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,23]]},"assertion":[{"value":"18 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12608"}}