{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T23:56:14Z","timestamp":1794441374465,"version":"4.9.1"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T00:00:00Z","timestamp":1658188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T00:00:00Z","timestamp":1658188800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>3D-navigated pedicle screw placement is increasingly performed as the accuracy has been shown to be considerably higher compared to fluoroscopy-guidance. While different imaging and navigation devices can be used, there are few studies comparing these under similar conditions. Thus, the objective of this study was to compare the accuracy of two combinations most used in the literature for spinal navigation and a recently approved combination of imaging device and navigation system. With each combination of imaging system and navigation interface, 160 navigated screws were placed percutaneously in spine levels T11-S1 in ten artificial spine models. 470 screws were included in the final evaluation. Two blinded observers classified screw placement according to the Gertzbein Robbins grading system. Grades A and B were considered acceptable and Grades C-E unacceptable. Weighted kappa was used to calculate reliability between the observers. Mean accuracy was 94.9% (149\/157) for iCT\/Curve, 97.5% (154\/158) for C-arm CBCT\/Pulse and 89.0% for CBCT\/StealthStation (138\/155). The differences between the different combinations were not statistically significant except for the comparison of C-arm CBCT\/Pulse and CBCT\/StealthStation (p\u2009=\u20090.003). Relevant perforations of the medial pedicle wall were only seen in the CBCT group. Weighted interrater reliability was found to be 0.896 for iCT, 0.424 for C-arm CBCT and 0.709 for CBCT. Under quasi-identical conditions, higher screw accuracy was achieved with the combinations iCT\/Curve and C-arm CBCT\/Pulse compared with CBCT\/StealthStation. However, the exact reasons for the difference in accuracy remain unclear. Weighted interrater reliability for Gertzbein Robbins grading was moderate for C-arm CBCT, substantial for CBCT and almost perfect for iCT.<\/jats:p>","DOI":"10.1038\/s41598-022-16709-y","type":"journal-article","created":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T15:04:30Z","timestamp":1658243070000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Comparison of three imaging and navigation systems regarding accuracy of pedicle screw placement in a sawbone model"],"prefix":"10.1038","volume":"12","author":[{"given":"Nils","family":"Beisemann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jula","family":"Gierse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Mandelka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Hassel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul A.","family":"Gr\u00fctzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jochen","family":"Franke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8024-9276","authenticated-orcid":false,"given":"Sven Y.","family":"Vetter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,19]]},"reference":[{"key":"16709_CR1","doi-asserted-by":"publisher","first-page":"1698","DOI":"10.1007\/s00586-018-5513-4","volume":"27","author":"K Kobayashi","year":"2018","unstructured":"Kobayashi, K., Ando, K., Nishida, Y., Ishiguro, N. & Imagama, S. Epidemiological trends in spine surgery over 10 years in a multicenter database. Eur. Spine J. 27, 1698\u20131703. https:\/\/doi.org\/10.1007\/s00586-018-5513-4 (2018).","journal-title":"Eur. Spine J."},{"key":"16709_CR2","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1007\/s00113-017-0435-x","volume":"120","author":"KJ Schnake","year":"2017","unstructured":"Schnake, K. J. et al. Thoracolumbar spinal fractures in the elderly\u202f: Classification and treatment. Unfallchirurg 120, 1071\u20131085. https:\/\/doi.org\/10.1007\/s00113-017-0435-x (2017).","journal-title":"Unfallchirurg"},{"key":"16709_CR3","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1097\/00007632-199311000-00015","volume":"18","author":"SI Esses","year":"1993","unstructured":"Esses, S. I., Sachs, B. L. & Dreyzin, V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18, 2231\u20132238. https:\/\/doi.org\/10.1097\/00007632-199311000-00015 (1993) ((discussion 2238\u20132239)).","journal-title":"Spine (Phila Pa 1976)"},{"key":"16709_CR4","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.3171\/2011.7.Focus11168","volume":"31","author":"OP Gautschi","year":"2011","unstructured":"Gautschi, O. P., Schatlo, B., Schaller, K. & Tessitore, E. Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: A literature review of 35,630 pedicle screws. Neurosurg. Focus 31, E8. https:\/\/doi.org\/10.3171\/2011.7.Focus11168 (2011).","journal-title":"Neurosurg. Focus"},{"key":"16709_CR5","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1007\/bf01142678","volume":"6","author":"AA Faraj","year":"1997","unstructured":"Faraj, A. A. & Webb, J. K. Early complications of spinal pedicle screw. Eur. Spine J. 6, 324\u2013326. https:\/\/doi.org\/10.1007\/bf01142678 (1997).","journal-title":"Eur. Spine J."},{"key":"16709_CR6","doi-asserted-by":"publisher","unstructured":"Vaccaro, A. R. et al. Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. J. Bone Jt. Surg. Am. 77, 1193\u20131199. https:\/\/doi.org\/10.2106\/00004623-199508000-00008 (1995).","DOI":"10.2106\/00004623-199508000-00008"},{"key":"16709_CR7","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1097\/00007632-198703000-00012","volume":"12","author":"MR Zindrick","year":"1987","unstructured":"Zindrick, M. R. et al. Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine (Phila Pa 1976) 12, 160\u2013166. https:\/\/doi.org\/10.1097\/00007632-198703000-00012 (1987).","journal-title":"Spine (Phila Pa 1976)"},{"key":"16709_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2020.106113","volume":"198","author":"R Ganguly","year":"2020","unstructured":"Ganguly, R., Minnema, A., Singh, V. & Grossbach, A. Retrospective analysis of pedicle screw accuracy for patients undergoing spinal surgery assisted by intraoperative computed tomography (CT) scanner AIRO\u00ae and BrainLab\u00a9 navigation. Clin. Neurol. Neurosurg. 198, 106113. https:\/\/doi.org\/10.1016\/j.clineuro.2020.106113 (2020).","journal-title":"Clin. Neurol. Neurosurg."},{"key":"16709_CR9","doi-asserted-by":"publisher","first-page":"S54","DOI":"10.1097\/01.Brs.0000076899.78522.D9","volume":"28","author":"LT Holly","year":"2003","unstructured":"Holly, L. T. & Foley, K. T. Intraoperative spinal navigation. Spine (Phila Pa 1976) 28, S54\u2013S61. https:\/\/doi.org\/10.1097\/01.Brs.0000076899.78522.D9 (2003).","journal-title":"Spine (Phila Pa 1976)"},{"key":"16709_CR10","doi-asserted-by":"publisher","first-page":"532","DOI":"10.3171\/2010.10.Spine091032","volume":"14","author":"MF Oertel","year":"2011","unstructured":"Oertel, M. F., Hobart, J., Stein, M., Schreiber, V. & Scharbrodt, W. Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging. J. Neurosurg. Spine 14, 532\u2013536. https:\/\/doi.org\/10.3171\/2010.10.Spine091032 (2011).","journal-title":"J. Neurosurg. Spine"},{"issue":"Suppl 1","key":"16709_CR11","doi-asserted-by":"publisher","first-page":"S-a35","DOI":"10.1016\/j.injury.2004.05.009","volume":"35","author":"F Gebhard","year":"2004","unstructured":"Gebhard, F., Weidner, A., Liener, U. C., St\u00f6ckle, U. & Arand, M. Navigation at the spine. Injury 35(Suppl 1), S-a35-S-a45. https:\/\/doi.org\/10.1016\/j.injury.2004.05.009 (2004).","journal-title":"Injury"},{"key":"16709_CR12","doi-asserted-by":"publisher","first-page":"4563","DOI":"10.1118\/1.3597566","volume":"38","author":"S Schafer","year":"2011","unstructured":"Schafer, S. et al. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance. Med. Phys. 38, 4563\u20134574. https:\/\/doi.org\/10.1118\/1.3597566 (2011).","journal-title":"Med. Phys."},{"key":"16709_CR13","doi-asserted-by":"publisher","first-page":"e24","DOI":"10.1016\/j.wneu.2017.09.091","volume":"109","author":"J Fichtner","year":"2018","unstructured":"Fichtner, J. et al. Revision rate of misplaced pedicle screws of the thoracolumbar spine-comparison of three-dimensional fluoroscopy navigation with freehand placement: A systematic analysis and review of the literature. World Neurosurg. 109, e24\u2013e32. https:\/\/doi.org\/10.1016\/j.wneu.2017.09.091 (2018).","journal-title":"World Neurosurg."},{"key":"16709_CR14","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s10143-015-0679-2","volume":"39","author":"X-T Meng","year":"2016","unstructured":"Meng, X.-T., Guan, X.-F., Zhang, H.-L. & He, S.-S. Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: A meta-analysis. Neurosurg. Rev. 39, 385\u2013391. https:\/\/doi.org\/10.1007\/s10143-015-0679-2 (2016).","journal-title":"Neurosurg. Rev."},{"key":"16709_CR15","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","volume":"126","author":"A Perdomo-Pantoja","year":"2019","unstructured":"Perdomo-Pantoja, A. et al. Accuracy of current techniques for placement of pedicle screws in the spine: A comprehensive systematic review and meta-analysis of 51,161 screws. World Neurosurg. 126, 664-678.e663. https:\/\/doi.org\/10.1016\/j.wneu.2019.02.217 (2019).","journal-title":"World Neurosurg."},{"key":"16709_CR16","doi-asserted-by":"publisher","first-page":"113","DOI":"10.3171\/2012.5.Spine11399","volume":"17","author":"BJ Shin","year":"2012","unstructured":"Shin, B. J., James, A. R., Njoku, I. U. & H\u00e4rtl, R. Pedicle screw navigation: A systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion. J. Neurosurg. Spine 17, 113\u2013122. https:\/\/doi.org\/10.3171\/2012.5.Spine11399 (2012).","journal-title":"J. Neurosurg. Spine"},{"key":"16709_CR17","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1007\/s00586-010-1577-5","volume":"20","author":"N-F Tian","year":"2011","unstructured":"Tian, N.-F. et al. Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies. Eur. Spine J. 20, 846\u2013859. https:\/\/doi.org\/10.1007\/s00586-010-1577-5 (2011).","journal-title":"Eur. Spine J."},{"key":"16709_CR18","doi-asserted-by":"publisher","first-page":"157","DOI":"10.3109\/10929080802102110","volume":"13","author":"J Geerling","year":"2008","unstructured":"Geerling, J. et al. Navigated pedicle screw placement: Experimental comparison between CT- and 3D fluoroscopy-based techniques. Comput. Aided Surg. 13, 157\u2013166. https:\/\/doi.org\/10.3109\/10929080802102110 (2008).","journal-title":"Comput. Aided Surg."},{"key":"16709_CR19","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/978-3-319-39546-3_42","volume":"124","author":"G Innocenzi","year":"2017","unstructured":"Innocenzi, G., Bistazzoni, S., D\u2019Ercole, M., Cardarelli, G. & Ricciardi, F. Does navigation improve pedicle screw placement accuracy? Comparison between navigated and non-navigated percutaneous and open fixations. Acta Neurochir. Suppl. 124, 289\u2013295. https:\/\/doi.org\/10.1007\/978-3-319-39546-3_42 (2017).","journal-title":"Acta Neurochir. Suppl."},{"key":"16709_CR20","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3171\/2013.11.Spine13413","volume":"20","author":"A Mason","year":"2014","unstructured":"Mason, A. et al. The accuracy of pedicle screw placement using intraoperative image guidance systems. J. Neurosurg. Spine 20, 196\u2013203. https:\/\/doi.org\/10.3171\/2013.11.Spine13413 (2014).","journal-title":"J. Neurosurg. Spine"},{"key":"16709_CR21","doi-asserted-by":"publisher","unstructured":"Mirza, S. K. et al. Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study. Spine (Phila Pa 1976) 28, 402\u2013413. https:\/\/doi.org\/10.1097\/01.Brs.0000048461.51308.Cd (2003).","DOI":"10.1097\/01.Brs.0000048461.51308.Cd"},{"key":"16709_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-021-06981-3","author":"S Ille","year":"2021","unstructured":"Ille, S., Baumgart, L., Obermueller, T., Meyer, B. & Krieg, S. M. Clinical efficiency of operating room-based sliding gantry CT as compared to mobile cone-beam CT-based navigated pedicle screw placement in 853 patients and 6733 screws. Eur. Spine J. https:\/\/doi.org\/10.1007\/s00586-021-06981-3 (2021).","journal-title":"Eur. Spine J."},{"key":"16709_CR23","doi-asserted-by":"publisher","first-page":"155","DOI":"10.21037\/jss.2019.02.04","volume":"5","author":"GM Malham","year":"2019","unstructured":"Malham, G. M. & Wells-Quinn, T. What should my hospital buy next?-Guidelines for the acquisition and application of imaging, navigation, and robotics for spine surgery. J. Spine Surg. 5, 155\u2013165. https:\/\/doi.org\/10.21037\/jss.2019.02.04 (2019).","journal-title":"J. Spine Surg."},{"key":"16709_CR24","doi-asserted-by":"publisher","first-page":"e175","DOI":"10.1016\/j.wneu.2018.06.148","volume":"118","author":"K Farah","year":"2018","unstructured":"Farah, K. et al. Prospective comparative study in spine surgery between O-arm and Airo systems: Efficacy and radiation exposure. World Neurosurg. 118, e175\u2013e184. https:\/\/doi.org\/10.1016\/j.wneu.2018.06.148 (2018).","journal-title":"World Neurosurg."},{"key":"16709_CR25","doi-asserted-by":"publisher","unstructured":"Hecht, N. et al. Intraoperative computed tomography versus 3D C-arm imaging for navigated spinal instrumentation. Spine (Phila Pa 1976) 43, 370\u2013377. https:\/\/doi.org\/10.1097\/brs.0000000000002173 (2018).","DOI":"10.1097\/brs.0000000000002173"},{"key":"16709_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2020.02.093","author":"M Privalov","year":"2020","unstructured":"Privalov, M. et al. First experiences with intraoperative CT in navigated sacroiliac (SI) instrumentation: An analysis of 25 cases and comparison with conventional intraoperative 2D and 3D imaging. Injury https:\/\/doi.org\/10.1016\/j.injury.2020.02.093 (2020).","journal-title":"Injury"},{"key":"16709_CR27","doi-asserted-by":"publisher","unstructured":"Keil, H. et al. Evaluation of image quality and assessability of a new flat-panel 3D C-arm compared to mobile and fixed computed tomography in posterior spinal fixation. Int. J. Med. Robot. https:\/\/doi.org\/10.1002\/rcs.2181 (2020).","DOI":"10.1002\/rcs.2181"},{"key":"16709_CR28","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jspd.2018.04.010","volume":"6","author":"JM Bauer","year":"2018","unstructured":"Bauer, J. M. et al. Intraoperative CT scan verification of pedicle screw placement in AIS to prevent malpositioned screws: Safety benefit and cost. Spine Deform. 6, 662\u2013668. https:\/\/doi.org\/10.1016\/j.jspd.2018.04.010 (2018).","journal-title":"Spine Deform."},{"key":"16709_CR29","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1007\/s00586-009-1258-4","volume":"19","author":"R Verma","year":"2010","unstructured":"Verma, R., Krishan, S., Haendlmayer, K. & Mohsen, A. Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5,992 pedicle screws. Eur. Spine J. 19, 370\u2013375. https:\/\/doi.org\/10.1007\/s00586-009-1258-4 (2010).","journal-title":"Eur. Spine J."},{"key":"16709_CR30","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein, S. D. & Robbins, S. E. Accuracy of pedicular screw placement in vivo. Spine 15, 11\u201314 (1990).","journal-title":"Spine"},{"key":"16709_CR31","doi-asserted-by":"publisher","unstructured":"Rampersaud, Y. R., Pik, J. H., Salonen, D. & Farooq, S. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine (Phila Pa 1976) 30, E183\u2013190. https:\/\/doi.org\/10.1097\/01.brs.0000157490.65706.38 (2005).","DOI":"10.1097\/01.brs.0000157490.65706.38"},{"key":"16709_CR32","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis, J. R. & Koch, G. G. The measurement of observer agreement for categorical data. Biometrics 33, 159\u2013174. https:\/\/doi.org\/10.2307\/2529310 (1977).","journal-title":"Biometrics"},{"key":"16709_CR33","doi-asserted-by":"publisher","unstructured":"Frisk, H. et al. Feasibility and accuracy of thoracolumbar pedicle screw placement using an augmented reality head mounted device. Sensors (Basel). https:\/\/doi.org\/10.3390\/s22020522 (2022).","DOI":"10.3390\/s22020522"},{"key":"16709_CR34","doi-asserted-by":"publisher","unstructured":"Burstr\u00f6m, G., Nachabe, R., Persson, O., Edstr\u00f6m, E. & Elmi Terander, A. Augmented and virtual reality instrument tracking for minimally invasive spine surgery: A feasibility and accuracy study. Spine (Phila Pa 1976) 44, 1097\u20131104. https:\/\/doi.org\/10.1097\/brs.0000000000003006 (2019).","DOI":"10.1097\/brs.0000000000003006"},{"key":"16709_CR35","doi-asserted-by":"publisher","unstructured":"Rao, G., Brodke, D. S., Rondina, M., Bacchus, K. & Dailey, A. T. Inter- and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement. Spine (Phila Pa 1976) 28, 2527\u20132530. https:\/\/doi.org\/10.1097\/01.Brs.0000092341.56793.F1 (2003).","DOI":"10.1097\/01.Brs.0000092341.56793.F1"},{"key":"16709_CR36","doi-asserted-by":"publisher","first-page":"11","DOI":"10.14444\/1011","volume":"8","author":"WF Lavelle","year":"2014","unstructured":"Lavelle, W. F. et al. Inter- and intra-observer reliability of measurement of pedicle screw breach assessed by postoperative CT scans. Int. J. Spine Surg. 8, 11. https:\/\/doi.org\/10.14444\/1011 (2014).","journal-title":"Int. J. Spine Surg."},{"key":"16709_CR37","doi-asserted-by":"publisher","first-page":"2349","DOI":"10.1007\/s00330-020-07315-5","volume":"31","author":"G Burstr\u00f6m","year":"2021","unstructured":"Burstr\u00f6m, G. et al. Intraoperative cone beam computed tomography is as reliable as conventional computed tomography for identification of pedicle screw breach in thoracolumbar spine surgery. Eur. Radiol. 31, 2349\u20132356. https:\/\/doi.org\/10.1007\/s00330-020-07315-5 (2021).","journal-title":"Eur. Radiol."},{"key":"16709_CR38","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1007\/s00586-019-06242-4","volume":"29","author":"D Tkatschenko","year":"2020","unstructured":"Tkatschenko, D. et al. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging. Eur. Spine J. 29, 803\u2013812. https:\/\/doi.org\/10.1007\/s00586-019-06242-4 (2020).","journal-title":"Eur. Spine J."},{"key":"16709_CR39","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1007\/s00586-015-3814-4","volume":"25","author":"N Hecht","year":"2016","unstructured":"Hecht, N. et al. Accuracy and workflow of navigated spinal instrumentation with the mobile AIRO(\u00ae) CT scanner. Eur. Spine J. 25, 716\u2013723. https:\/\/doi.org\/10.1007\/s00586-015-3814-4 (2016).","journal-title":"Eur. Spine J."},{"key":"16709_CR40","doi-asserted-by":"publisher","unstructured":"Van de Kelft, E., Costa, F., Van der Planken, D. & Schils, F. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine (Phila Pa 1976) 37, E1580\u20131587. https:\/\/doi.org\/10.1097\/BRS.0b013e318271b1fa (2012).","DOI":"10.1097\/BRS.0b013e318271b1fa"},{"key":"16709_CR41","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s11701-019-00994-3","volume":"14","author":"AB Vardiman","year":"2020","unstructured":"Vardiman, A. B. et al. Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery. J. Robot Surg. 14, 409\u2013413. https:\/\/doi.org\/10.1007\/s11701-019-00994-3 (2020).","journal-title":"J. Robot Surg."},{"key":"16709_CR42","doi-asserted-by":"publisher","unstructured":"Kosmopoulos, V. & Schizas, C. Pedicle screw placement accuracy: A meta-analysis. Spine (Phila Pa 1976) 32, E111\u2013120. https:\/\/doi.org\/10.1097\/01.brs.0000254048.79024.8b (2007).","DOI":"10.1097\/01.brs.0000254048.79024.8b"},{"key":"16709_CR43","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2021.12.103","author":"N Foster","year":"2022","unstructured":"Foster, N. et al. Image quality and dose comparison of 3 mobile intraoperative three-dimensional imaging systems in spine surgery. World Neurosurg. https:\/\/doi.org\/10.1016\/j.wneu.2021.12.103 (2022).","journal-title":"World Neurosurg."},{"key":"16709_CR44","doi-asserted-by":"publisher","unstructured":"Gonzalvo, A. et al. The learning curve of pedicle screw placement: How many screws are enough? Spine (Phila Pa 1976) 34, E761\u2013765. https:\/\/doi.org\/10.1097\/BRS.0b013e3181b2f928 (2009).","DOI":"10.1097\/BRS.0b013e3181b2f928"},{"key":"16709_CR45","doi-asserted-by":"publisher","first-page":"38","DOI":"10.14444\/3038","volume":"10","author":"CA Miller","year":"2016","unstructured":"Miller, C. A., Ledonio, C. G., Hunt, M. A., Siddiq, F. & Polly, D. W. Jr. Reliability of the planned pedicle screw trajectory versus the actual pedicle screw trajectory using intra-operative 3D CT and image guidance. Int. J. Spine Surg. 10, 38\u201338. https:\/\/doi.org\/10.14444\/3038 (2016).","journal-title":"Int. J. Spine Surg."},{"key":"16709_CR46","doi-asserted-by":"publisher","unstructured":"Laudato, P. A., Pierzchala, K. & Schizas, C. Pedicle screw insertion accuracy using O-arm, robotic guidance, or freehand technique: A comparative study. Spine (Phila Pa 1976) 43, E373\u2013E378. https:\/\/doi.org\/10.1097\/brs.0000000000002449 (2018).","DOI":"10.1097\/brs.0000000000002449"},{"key":"16709_CR47","doi-asserted-by":"publisher","unstructured":"Pojski\u0107, M., Bopp, M., Nimsky, C., Carl, B. & Sa\u03b2, B. Initial intraoperative experience with robotic-assisted pedicle screw placement with Cirq(\u00ae) robotic alignment: An evaluation of the first 70 screws. J. Clin. Med. https:\/\/doi.org\/10.3390\/jcm10245725 (2021).","DOI":"10.3390\/jcm10245725"},{"key":"16709_CR48","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.1007\/s00586-018-5587-z","volume":"27","author":"T Tajsic","year":"2018","unstructured":"Tajsic, T., Patel, K., Farmer, R., Mannion, R. J. & Trivedi, R. A. Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: Implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur. Spine J. 27, 1918\u20131924. https:\/\/doi.org\/10.1007\/s00586-018-5587-z (2018).","journal-title":"Eur. Spine J."},{"key":"16709_CR49","doi-asserted-by":"publisher","first-page":"112","DOI":"10.5312\/wjo.v5.i2.112","volume":"5","author":"V Puvanesarajah","year":"2014","unstructured":"Puvanesarajah, V., Liauw, J. A., Lo, S. F., Lina, I. A. & Witham, T. F. Techniques and accuracy of thoracolumbar pedicle screw placement. World J. Orthop. 5, 112\u2013123. https:\/\/doi.org\/10.5312\/wjo.v5.i2.112 (2014).","journal-title":"World J. Orthop."},{"key":"16709_CR50","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.wneu.2017.07.154","volume":"109","author":"JP Du","year":"2018","unstructured":"Du, J. P. et al. Accuracy of pedicle screw insertion among 3 image-guided navigation systems: Systematic review and meta-analysis. World Neurosurg. 109, 24\u201330. https:\/\/doi.org\/10.1016\/j.wneu.2017.07.154 (2018).","journal-title":"World Neurosurg."},{"key":"16709_CR51","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1016\/j.wneu.2020.07.205","volume":"144","author":"J Sun","year":"2020","unstructured":"Sun, J., Wu, D., Wang, Q., Wei, Y. & Yuan, F. Pedicle screw insertion: Is O-arm-based navigation superior to the conventional freehand technique? A systematic review and meta-analysis. World Neurosurg. 144, e87\u2013e99. https:\/\/doi.org\/10.1016\/j.wneu.2020.07.205 (2020).","journal-title":"World Neurosurg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16709-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16709-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16709-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T04:47:25Z","timestamp":1669351645000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-16709-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,19]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["16709"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-16709-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,19]]},"assertion":[{"value":"15 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The research group MINTOS had grants\/grants pending and technical support from Siemens Healthineers (Erlangen, Germany) and Nuvasive Inc. (San Diego, USA). The funders had no involvement in the study conceptualization, design, data collection, analysis, nor the decision to publish or the preparation of the manuscript. FH serves as a consultant to Medtronic. JF and PAG serve as unpaid members of a consulting\/advisory board for Siemens Healthineers. The other authors declare that they have no financial or non-financial interests to disclose.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12344"}}