{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T14:07:58Z","timestamp":1791986878894,"version":"4.4.0"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01 MH111825"],"award-info":[{"award-number":["R01 MH111825"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Transcranial focused ultrasound with the InSightec Exablate system uses thermal ablation for the treatment of movement and mood disorders and blood brain barrier disruption for tumor therapy. The system uses computed tomography (CT) images to calculate phase corrections that account for aberrations caused by the human skull. This work investigates whether magnetic resonance (MR) images can be used as an alternative to CT images to calculate phase corrections. Phase corrections were calculated using the gold standard hydrophone method and the standard of care InSightec ray tracing method. MR binary image mask, MR-simulated-CT (MRsimCT), and CT images of three ex vivo human skulls were supplied as inputs to the InSightec ray tracing method. The degassed ex vivo human skulls were sonicated with a 670\u00a0kHz hemispherical phased array transducer (InSightec Exablate 4000). 3D raster scans of the beam profiles were acquired using a hydrophone mounted on a 3-axis positioner system. Focal spots were evaluated using six metrics: pressure at the target, peak pressure, intensity at the target, peak intensity, positioning error, and focal spot volume. Targets at the geometric focus and 5\u00a0mm lateral to the geometric focus were investigated. There was no statistical difference between any of the metrics at either target using either MRsimCT or CT for phase aberration correction. As opposed to the MRsimCT, the use of CT images for aberration correction requires registration to the treatment day MR images; CT misregistration within a range of\u2009\u00b1\u20092 degrees of rotation error along three dimensions was shown to reduce focal spot intensity by up to 9.4%. MRsimCT images used for phase aberration correction for the skull produce similar results as CT-based correction, while avoiding both CT to MR registration errors and unnecessary patient exposure to ionizing radiation.\n<\/jats:p>","DOI":"10.1038\/s41598-022-17319-4","type":"journal-article","created":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T12:03:11Z","timestamp":1659614591000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":43,"title":["Comparison between MR and CT imaging used to correct for skull-induced phase aberrations during transcranial focused ultrasound"],"prefix":"10.1038","volume":"12","author":[{"given":"Steven A.","family":"Leung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yekaterina","family":"Gilbo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Snell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taylor D.","family":"Webb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig H.","family":"Meyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Wilson","family":"Miller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pejman","family":"Ghanouni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kim","family":"Butts Pauly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,4]]},"reference":[{"key":"17319_CR1","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1056\/NEJMoa1300962","volume":"369","author":"WJ Elias","year":"2013","unstructured":"Elias, W. J. et al. A pilot study of focused ultrasound thalamotomy for essential tremor. N. Engl. J. Med. 369, 640\u2013648 (2013).","journal-title":"N. Engl. J. Med."},{"key":"17319_CR2","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/2050-5736-2-17","volume":"2","author":"D Coluccia","year":"2014","unstructured":"Coluccia, D. et al. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound. J. Ther. Ultrasound 2, 17 (2014).","journal-title":"J. Ther. Ultrasound"},{"key":"17319_CR3","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/2050-5736-2-11","volume":"2","author":"A Magara","year":"2014","unstructured":"Magara, A. et al. First experience with MR-guided focused ultrasound in the treatment of Parkinson\u2019s disease. J. Ther. Ultrasound 2, 11 (2014).","journal-title":"J. Ther. Ultrasound"},{"key":"17319_CR4","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/S1474-4422(17)30403-9","volume":"17","author":"R Mart\u00ednez-Fern\u00e1ndez","year":"2018","unstructured":"Mart\u00ednez-Fern\u00e1ndez, R. et al. Focused ultrasound subthalamotomy in patients with asymmetric Parkinson\u2019s disease: A pilot study. Lancet Neurol. 17, 54 (2018).","journal-title":"Lancet Neurol."},{"key":"17319_CR5","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1038\/nn.3620","volume":"17","author":"W Legon","year":"2014","unstructured":"Legon, W. et al. Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans. Nat. Neurosci. 17, 322\u2013329 (2014).","journal-title":"Nat. Neurosci."},{"key":"17319_CR6","doi-asserted-by":"publisher","first-page":"8743","DOI":"10.1038\/srep08743","volume":"5","author":"W Lee","year":"2015","unstructured":"Lee, W. et al. Image-guided transcranial focused ultrasound stimulates human primary somatosensory cortex. Sci. Rep. 5, 8743 (2015).","journal-title":"Sci. Rep."},{"key":"17319_CR7","doi-asserted-by":"publisher","first-page":"34026","DOI":"10.1038\/srep34026","volume":"6","author":"W Lee","year":"2016","unstructured":"Lee, W. et al. Transcranial focused ultrasound stimulation of human primary visual cortex. Sci. Rep. 6, 34026 (2016).","journal-title":"Sci. Rep."},{"key":"17319_CR8","volume-title":"Consensus on Hyperthermia for the 1990s","author":"JT Patrick","year":"1990","unstructured":"Patrick, J. T. et al. Ultrasound and the blood-brain barrier. In Consensus on Hyperthermia for the 1990s (eds Bicher, H. I. et al.) (Springer, 1990)."},{"key":"17319_CR9","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1148\/radiol.2202001804","volume":"220","author":"K Hynynen","year":"2001","unstructured":"Hynynen, K. & Mcdannold, N. Imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 220, 640\u2013646 (2001).","journal-title":"Radiology"},{"key":"17319_CR10","doi-asserted-by":"publisher","first-page":"3652","DOI":"10.1158\/0008-5472.CAN-12-0128","volume":"72","author":"N Mcdannold","year":"2012","unstructured":"Mcdannold, N., Arvanitis, C. D., Vykhodtseva, N. & Livingstone, M. S. Temporary disruption of the blood\u2013brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in Rhesus Macaques. Am. Assoc. Cancer Res. 72, 3652\u20133664 (2012).","journal-title":"Am. Assoc. Cancer Res."},{"key":"17319_CR11","doi-asserted-by":"publisher","first-page":"15076","DOI":"10.1038\/srep15076","volume":"5","author":"ME Downs","year":"2015","unstructured":"Downs, M. E., Buch, A., Karakatsani, M. E., Konofagou, E. E. & Ferrera, V. P. Blood-brain barrier opening in behaving non-human primates via focused ultrasound with systemically administered microbubbles. Sci. Rep. 5, 15076 (2015).","journal-title":"Sci. Rep."},{"key":"17319_CR12","doi-asserted-by":"publisher","first-page":"5170","DOI":"10.1118\/1.4955436","volume":"43","author":"U Vyas","year":"2016","unstructured":"Vyas, U. et al. Predicting variation in subject thermal response during transcranial magnetic resonance guided focused ultrasound surgery: Comparison in seventeen subject datasets. Med. Phys. 43, 5170\u20135180 (2016).","journal-title":"Med. Phys."},{"key":"17319_CR13","doi-asserted-by":"publisher","first-page":"36","DOI":"10.3109\/02656736.2013.861519","volume":"30","author":"A Kyriakou","year":"2014","unstructured":"Kyriakou, A. et al. A review of numerical and experimental compensation techniques for skull-induced phase aberrations in transcranial focused ultrasound. Int. J. Hyperth. 30, 36\u201346 (2014).","journal-title":"Int. J. Hyperth."},{"key":"17319_CR14","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s40349-015-0032-9","volume":"3","author":"A Kyriakou","year":"2015","unstructured":"Kyriakou, A., Neufeld, E., Werner, B., Sz\u00e9kely, G. & Kuster, N. Full-wave acoustic and thermal modeling of transcranial ultrasound propagation and investigation of skull-induced aberration correction techniques: a feasibility study. J. Ther. Ultrasound 3, 11 (2015).","journal-title":"J. Ther. Ultrasound"},{"key":"17319_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s42490-020-00043-3","volume":"2","author":"C Jin","year":"2020","unstructured":"Jin, C., Moore, D., Snell, J. & Paeng, D. An open-source phase correction toolkit for transcranial focused ultrasound. BMC Biomed. Eng. 2, 1\u201311 (2020).","journal-title":"BMC Biomed. Eng."},{"key":"17319_CR16","doi-asserted-by":"publisher","first-page":"3925","DOI":"10.1088\/0031-9155\/47\/22\/302","volume":"47","author":"C Connor","year":"2002","unstructured":"Connor, C., Clement, G. & Hynynen, K. A unified model for the speed of sound in cranial bone based on genetic algorithm optimization. Phys. Med. Biol. 47, 3925\u20133944 (2002).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR17","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1121\/1.1529663","volume":"113","author":"JF Aubry","year":"2003","unstructured":"Aubry, J. F., Tanter, M., Pernot, M., Thomas, J. L. & Fink, M. Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans. J. Acoust. Soc. Am. 113, 84\u201393 (2003).","journal-title":"J. Acoust. Soc. Am."},{"key":"17319_CR18","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1088\/0031-9155\/61\/1\/23","volume":"61","author":"RM Jones","year":"2016","unstructured":"Jones, R. M. & Hynynen, K. Comparison of analytical and numerical approaches for CT-based aberration correction in transcranial passive acoustic imaging. Phys. Med. Biol. 61, 23\u201336 (2016).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR19","doi-asserted-by":"publisher","first-page":"6350","DOI":"10.1080\/02656736.2017.1295322","volume":"33","author":"L Marsac","year":"2017","unstructured":"Marsac, L. et al. Ex vivo optimisation of a heterogeneous speed of sound model of the human skull for non-invasive transcranial focused ultrasound at 1 MHz. Int. J. Hyperth. 33, 6350 (2017).","journal-title":"Int. J. Hyperth."},{"key":"17319_CR20","doi-asserted-by":"publisher","first-page":"2597","DOI":"10.1088\/0031-9155\/54\/9\/001","volume":"54","author":"F Marquet","year":"2009","unstructured":"Marquet, F. et al. Non-invasive transcranial ultrasound therapy based on a 3D CT scan: Protocol validation and in vitro results. Phys. Med. Biol. 54, 2597\u20132613 (2009).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR21","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.1109\/TUFFC.2010.1738","volume":"57","author":"T Deffieux","year":"2010","unstructured":"Deffieux, T. & Konofagou, E. Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57, 2637\u20132653 (2010).","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"17319_CR22","first-page":"282","volume":"1215","author":"S Pichardo","year":"2011","unstructured":"Pichardo, S. & Hynynen, K. Multi-frequency characterization of speed of sound for longitudinal transmission on freshly excised human skulls. Phys. Med. Biol. 1215, 282\u2013286 (2011).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR23","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1299\/jbse.7.43","volume":"7","author":"N Leduc","year":"2012","unstructured":"Leduc, N., Okita, K., Sugiyama, K., Takagi, S. & Matsumoto, Y. Focus control in HIFU therapy assisted by time-reversal simulation with an iterative procedure for hot spot elimination. J. Biomech. Sci. Eng. 7, 43\u201356 (2012).","journal-title":"J. Biomech. Sci. Eng."},{"key":"17319_CR24","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1016\/j.ultrasmedbio.2013.12.025","volume":"40","author":"G Bouchoux","year":"2014","unstructured":"Bouchoux, G., Shivashankar, R., Abruzzo, T. A. & Holland, C. K. In silico study of low-frequency transcranial ultrasound fields in acute ischemic stroke patients. Ultrasound Med. Biol. 40, 1154\u20131166 (2014).","journal-title":"Ultrasound Med. Biol."},{"key":"17319_CR25","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1088\/0031-9155\/59\/7\/1679","volume":"59","author":"A Pulkkinen","year":"2014","unstructured":"Pulkkinen, A., Werner, B., Martin, E. & Hynynen, K. Numerical simulations of clinical focused ultrasound functional neurosurgery. Phys. Med. Biol. 59, 1679\u20131700 (2014).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR26","doi-asserted-by":"publisher","first-page":"4385","DOI":"10.1118\/1.4922677","volume":"42","author":"RM Jones","year":"2015","unstructured":"Jones, R. M. & Reilly, M. A. O. Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections. Med. Phys. 42, 4385 (2015).","journal-title":"Med. Phys."},{"key":"17319_CR27","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1118\/1.4939809","volume":"43","author":"CB Top","year":"2016","unstructured":"Top, C. B., White, P. J. & McDannold, N. J. Nonthermal ablation of deep brain targets: A simulation study on a large animal model. Med. Phys. 43, 870\u2013882 (2016).","journal-title":"Med. Phys."},{"key":"17319_CR28","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1121\/1.4976339","volume":"141","author":"JLB Robertson","year":"2017","unstructured":"Robertson, J. L. B., Cox, B. T., Jaros, J. & Treeby, B. E. Accurate simulation of transcranial ultrasound propagation for ultrasonic neuromodulation and stimulation. J. Acoust. Soc. Am. 141, 1726\u20131738 (2017).","journal-title":"J. Acoust. Soc. Am."},{"key":"17319_CR29","doi-asserted-by":"publisher","first-page":"2559","DOI":"10.1088\/1361-6560\/aa5e98","volume":"62","author":"J Robertson","year":"2017","unstructured":"Robertson, J., Martin, E., Cox, B. & Treeby, B. E. Sensitivity of simulated transcranial ultrasound fields to acoustic medium property maps. Phys. Med. Biol. 62, 2559 (2017).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR30","doi-asserted-by":"publisher","first-page":"033205","DOI":"10.1103\/PhysRevResearch.1.033205","volume":"1","author":"N Mcdannold","year":"2019","unstructured":"Mcdannold, N., White, P. J. & Cosgrove, R. Elementwise approach for simulating transcranial MRI-guided focused ultrasound thermal ablation. Phys. Rev. Res. 1, 033205 (2019).","journal-title":"Phys. Rev. Res."},{"key":"17319_CR31","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1109\/TUFFC.2020.2993718","volume":"67","author":"G Maimbourg","year":"2020","unstructured":"Maimbourg, G. et al. Computationally efficient transcranial ultrasonic focusing: Taking advantage of the high correlation length of the human skull. IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 67, 1993 (2020).","journal-title":"IEEE Trans. Ultrason. Ferroelect. Freq. Contr."},{"key":"17319_CR32","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1109\/TUFFC.2012.2300","volume":"59","author":"U Vyas","year":"2012","unstructured":"Vyas, U. & Christensen, D. Ultrasound beam simulations in inhomogeneous tissue geometries using the hybrid angular spectrum method. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 1093\u20131100 (2012).","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"17319_CR33","first-page":"310","volume":"2014","author":"S Almquist","year":"2014","unstructured":"Almquist, S., de Bever, J., Merrill, R., Parker, D. & Christensen, D. A full-wave phase aberration correction method for transcranial high-intensity focused ultrasound brain therapies. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. 2014, 310\u2013313 (2014).","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"17319_CR34","doi-asserted-by":"publisher","first-page":"P9","DOI":"10.1186\/2050-5736-3-S1-P9","volume":"3","author":"S Almquist","year":"2015","unstructured":"Almquist, S., Parker, D. L. & Christensen, D. A. Simulation of hemispherical transducers for transcranial HIFU treatments using the hybrid angular spectrum approach. J. Ther. Ultrasound 3, P9 (2015).","journal-title":"J. Ther. Ultrasound"},{"key":"17319_CR35","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40349-016-0074-7","volume":"4","author":"S Almquist","year":"2016","unstructured":"Almquist, S., Parker, D. L. & Christensen, D. A. Rapid full-wave phase aberration correction method for transcranial high-intensity focused ultrasound therapies. J. Ther. Ultrasound 4, 30 (2016).","journal-title":"J. Ther. Ultrasound"},{"key":"17319_CR36","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-43775-6","author":"SA Leung","year":"2019","unstructured":"Leung, S. A., Webb, T. D., Bitton, R. R., Ghanouni, P. & Pauly, K. B. A rapid beam simulation framework for transcranial focused ultrasound. Sci. Rep. https:\/\/doi.org\/10.1038\/s41598-019-43775-6 (2019).","journal-title":"Sci. Rep."},{"key":"17319_CR37","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-85535-5","author":"SA Leung","year":"2021","unstructured":"Leung, S. A. et al. Transcranial focused ultrasound phase correction using the hybrid angular spectrum method. Sci. Rep. https:\/\/doi.org\/10.1038\/s41598-021-85535-5 (2021).","journal-title":"Sci. Rep."},{"key":"17319_CR38","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26160","author":"EM Johnson","year":"2016","unstructured":"Johnson, E. M., Vyas, U., Ghanouni, P., Pauly, K. B. & Pauly, J. M. Improved cortical bone specificity in UTE MR Imaging. Magn. Reson. Med. https:\/\/doi.org\/10.1002\/mrm.26160 (2016).","journal-title":"Magn. Reson. Med."},{"key":"17319_CR39","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1002\/mrm.25545","volume":"114","author":"F Wiesinger","year":"2016","unstructured":"Wiesinger, F. et al. Zero TE MR bone imaging in the head. Magn. Reson. Med. 114, 107\u2013114 (2016).","journal-title":"Magn. Reson. Med."},{"key":"17319_CR40","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1002\/mrm.27134","volume":"80","author":"F Wiesinger","year":"2018","unstructured":"Wiesinger, F., Bylund, M., Yang, J. & Kaushik, S. Magnetic resonance in medicine zero TE-based pseudo-CT image conversion in the head and its application in PET\/MR attenuation correction and MR-guided radiation therapy planning. Magn. Reson. Med. 80, 1440\u20131451. https:\/\/doi.org\/10.1002\/mrm.27134 (2018).","journal-title":"Magn. Reson. Med."},{"key":"17319_CR41","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab12f7","author":"S Guo","year":"2019","unstructured":"Guo, S. et al. Feasibility of ultrashort echo time images using full-wave acoustic and thermal modeling for transcranial MRI-guided focused ultrasound (tcMRgFUS) planning. Phys. Med. Biol. https:\/\/doi.org\/10.1088\/1361-6560\/ab12f7 (2019).","journal-title":"Phys. Med. Biol."},{"key":"17319_CR42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3174\/ajnr.A6758","volume":"41","author":"P Su","year":"2020","unstructured":"Su, P., Guo, S., Roys, S., Maier, F. & Bhat, H. Transcranial MR imaging-guided focused ultrasound interventions using deep learning synthesized CT. Am. J. Neuroradiol. 41, 1\u20138 (2020).","journal-title":"Am. J. Neuroradiol."},{"key":"17319_CR43","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1109\/JBHI.2021.3103387","volume":"26","author":"H Koh","year":"2022","unstructured":"Koh, H., Park, T. Y., Chung, Y. A., Lee, J. & Kim, H. Acoustic simulation for transcranial focused ultrasound using GAN-based synthetic CT. IEEE J. Biomed. Health Inform. 26, 161\u2013171 (2022).","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"17319_CR44","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.1118\/1.4916656","volume":"42","author":"GW Miller","year":"2015","unstructured":"Miller, G. W., Eames, M., Snell, J. & Aubry, J. F. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria. Med. Phys. 42, 2223\u20132233 (2015).","journal-title":"Med. Phys."},{"key":"17319_CR45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TUFFC.2018.2827899","volume":"65","author":"TD Webb","year":"2018","unstructured":"Webb, T. D. et al. Measurements of the relationship between CT hounsfield units and acoustic velocity and how it changes with photon energy and reconstruction method. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 65, 1\u201320 (2018).","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"17319_CR46","unstructured":"Mugler, J. P. et al. Breath-Hold UTE Lung Imaging Using a Stack-of-Spirals Acquisition.  (International Society for Magnetic Resonance Imaging, 2015)."},{"key":"17319_CR47","unstructured":"Hubbell, J. H. & Seltzer, S. M. Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients. (National Institute of Standard Technology, 2004)."},{"key":"17319_CR48","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1109\/TPAMI.1987.4767965","volume":"9","author":"K Arun","year":"1987","unstructured":"Arun, K., Huang, T. & Blostein, S. Least-squares fitting of two 3D point sets. IEEE Trans. Pattern Anal. Mach. Intell. 9, 698\u2013700 (1987).","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17319-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17319-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17319-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T05:14:29Z","timestamp":1669353269000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17319-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,4]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["17319"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-17319-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,4]]},"assertion":[{"value":"15 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13407"}}