{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:26:05Z","timestamp":1772756765250,"version":"3.50.1"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100008769","name":"Julius-Maximilians-Universit\u00e4t W\u00fcrzburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008769","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric\u00a0current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCT<jats:sub>SECO<\/jats:sub>). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.<\/jats:p>","DOI":"10.1038\/s41598-022-17732-9","type":"journal-article","created":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T14:08:53Z","timestamp":1659622133000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position"],"prefix":"10.1038","volume":"12","author":[{"given":"David P.","family":"Herrmann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franz-Tassilo","family":"M\u00fcller-Graff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Kaulitz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Cebulla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anja","family":"Kurz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rudolf","family":"Hagen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tilmann","family":"Neun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristen","family":"Rak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,8,4]]},"reference":[{"key":"17732_CR1","doi-asserted-by":"publisher","first-page":"S123","DOI":"10.1055\/s-0043-101812","volume":"96","author":"T Lenarz","year":"2017","unstructured":"Lenarz, T. Cochlear implant\u2014State of the art. Laryngo-Rhino-Otol. 96, S123\u2013S151 (2017).","journal-title":"Laryngo-Rhino-Otol."},{"key":"17732_CR2","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.joto.2019.01.002","volume":"14","author":"A Dhanasingh","year":"2019","unstructured":"Dhanasingh, A. & Jolly, C. Review on cochlear implant electrode array tip fold-over and scalar deviation. J. Otol. 14, 94\u2013100 (2019).","journal-title":"J. Otol."},{"key":"17732_CR3","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/s13244-020-00902-6","volume":"11","author":"G Widmann","year":"2020","unstructured":"Widmann, G., Dejaco, D., Luger, A. & Schmutzhard, J. Pre- and post-operative imaging of cochlear implants: A pictorial review. Insights Imaging 11, 93 (2020).","journal-title":"Insights Imaging"},{"key":"17732_CR4","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1080\/14670100.2020.1730066","volume":"21","author":"A Ishiyama","year":"2020","unstructured":"Ishiyama, A., Risi, F. & Boyd, P. Potential insertion complications with cochlear implant electrodes. Cochlear Implants Int. 21, 206\u2013219 (2020).","journal-title":"Cochlear Implants Int."},{"key":"17732_CR5","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0174900","volume":"12","author":"A B\u00fcchner","year":"2017","unstructured":"B\u00fcchner, A., Illg, A., Majdani, O. & Lenarz, T. Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis. PLoS ONE 12, e0174900 (2017).","journal-title":"PLoS ONE"},{"key":"17732_CR6","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1097\/MAO.0000000000001060","volume":"37","author":"NT Jiam","year":"2016","unstructured":"Jiam, N. T., Pearl, M. S., Carver, C. & Limb, C. J. Flat-panel CT imaging for individualized pitch mapping in cochlear implant users. Otol. Neurotol. 37, 672\u2013679 (2016).","journal-title":"Otol. Neurotol."},{"key":"17732_CR7","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1001\/jamaoto.2018.3096","volume":"145","author":"NT Jiam","year":"2019","unstructured":"Jiam, N. T. et al. Association between flat-panel computed tomographic imaging-guided place-pitch mapping and speech and pitch perception in cochlear implant users. JAMA Otolaryngol. Neck Surg. 145, 109\u2013116 (2019).","journal-title":"JAMA Otolaryngol. Neck Surg."},{"key":"17732_CR8","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1097\/MAO.0000000000001125","volume":"37","author":"BP O\u2019Connell","year":"2016","unstructured":"O\u2019Connell, B. P. et al. Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation. Otol. Neurotol. 37, 1016\u20131023 (2016).","journal-title":"Otol. Neurotol."},{"key":"17732_CR9","doi-asserted-by":"publisher","first-page":"2352","DOI":"10.1002\/lary.26467","volume":"127","author":"BP O\u2019Connell","year":"2017","unstructured":"O\u2019Connell, B. P. et al. Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. Laryngoscope 127, 2352\u20132357 (2017).","journal-title":"Laryngoscope"},{"key":"17732_CR10","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/s00106-020-00969-z","volume":"69","author":"K Rak","year":"2021","unstructured":"Rak, K. et al. Influence of cochlear parameters on the current practice in cochlear implantation. HNO 69, 24\u201330 (2021).","journal-title":"HNO"},{"key":"17732_CR11","doi-asserted-by":"publisher","first-page":"S16","DOI":"10.1055\/s-0030-1270448","volume":"90","author":"A Aschendorff","year":"2011","unstructured":"Aschendorff, A. Imaging bei cochlear-implant-patienten. Laryngo-Rhino-Otol. 90, S16\u2013S21 (2011).","journal-title":"Laryngo-Rhino-Otol."},{"key":"17732_CR12","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1111\/j.1365-2273.2007.01319.x","volume":"32","author":"B Carelsen","year":"2007","unstructured":"Carelsen, B. et al. Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray. Clin. Otolaryngol. 32, 46\u201350 (2007).","journal-title":"Clin. Otolaryngol."},{"key":"17732_CR13","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1007\/s00405-020-06151-z","volume":"278","author":"C Perazzini","year":"2021","unstructured":"Perazzini, C. et al. Fluoroscopy guided electrode-array insertion for cochlear implantation with straight electrode-arrays: A valuable tool in most cases. Eur. Arch. Otorhinolaryngol. 278, 965\u2013975 (2021).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"17732_CR14","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.wjorl.2020.04.006","volume":"7","author":"JH Barnes","year":"2021","unstructured":"Barnes, J. H., Yin, L. X., Saoji, A. A. & Carlson, M. L. Electrocochleography in cochlear implantation: Development, applications, and future directions. World J. Otorhinolaryngol. Head Neck Surg. 7, 94\u2013100 (2021).","journal-title":"World J. Otorhinolaryngol. Head Neck Surg."},{"key":"17732_CR15","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.1097\/MAO.0000000000000451","volume":"35","author":"NH Calloway","year":"2014","unstructured":"Calloway, N. H. et al. Intracochlear electrocochleography during cochlear implantation. Otol. Neurotol. 35, 1451\u20131457 (2014).","journal-title":"Otol. Neurotol."},{"key":"17732_CR16","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1097\/MAO.0000000000001559","volume":"38","author":"MS Harris","year":"2017","unstructured":"Harris, M. S. et al. Patterns seen during electrode insertion using intracochlear electrocochleography obtained directly through a cochlear implant. Otol. Neurotol. 38, 1415\u20131420 (2017).","journal-title":"Otol. Neurotol."},{"key":"17732_CR17","doi-asserted-by":"publisher","first-page":"1010","DOI":"10.1097\/MAO.0000000000000736","volume":"36","author":"P Mittmann","year":"2015","unstructured":"Mittmann, P., Ernst, A. & Todt, I. Intraoperative electrophysiologic variations caused by the scalar position of cochlear implant electrodes. Otol. Neurotol. 36, 1010\u20131014 (2015).","journal-title":"Otol. Neurotol."},{"key":"17732_CR18","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s00405-019-05653-9","volume":"277","author":"P Mittmann","year":"2020","unstructured":"Mittmann, P. et al. Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: A multi-center study case series. Eur. Arch. Otorhinolaryngol. 277, 31\u201335 (2020).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"17732_CR19","doi-asserted-by":"publisher","first-page":"S18","DOI":"10.1097\/MAO.0000000000002214","volume":"40","author":"FA Di Lella","year":"2019","unstructured":"Di Lella, F. A., De Marco, D., Fern\u00e1ndez, F., Parre\u00f1o, M. & Boccio, C. M. In vivo real-time remote cochlear implant capacitive impedance measurements: A glimpse into the implanted inner ear. Otol. Neurotol. 40, S18 (2019).","journal-title":"Otol. Neurotol."},{"key":"17732_CR20","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/MAO.0b013e31818f57ab","volume":"30","author":"W Grolman","year":"2009","unstructured":"Grolman, W. et al. Spread of excitation measurements for the detection of electrode array foldovers: A prospective study comparing 3-dimensional rotational X-ray and intraoperative spread of excitation measurements. Otol. Neurotol. 30, 27\u201333 (2009).","journal-title":"Otol. Neurotol."},{"key":"17732_CR21","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/6372704","volume":"2017","author":"A Stratmann","year":"2017","unstructured":"Stratmann, A. et al. MRI-based estimation of scalar cochlear-implant electrode position. BioMed Res. Int. 2017, e6372704 (2017).","journal-title":"BioMed Res. Int."},{"key":"17732_CR22","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1007\/s00106-017-0340-1","volume":"65","author":"J Prell","year":"2017","unstructured":"Prell, J., Strauss, C., Plontke, S. K. & Rampp, S. Intraoperative monitoring of the facial nerve: Vestibular schwannoma surgery. HNO 65, 404\u2013412 (2017).","journal-title":"HNO"},{"key":"17732_CR23","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1177\/0194599820915458","volume":"163","author":"K Casano","year":"2020","unstructured":"Casano, K. et al. Additional benefits of facial nerve monitoring during otologic surgery. Otolaryngol. Neck Surg. 163, 572\u2013576 (2020).","journal-title":"Otolaryngol. Neck Surg."},{"key":"17732_CR24","doi-asserted-by":"publisher","first-page":"2473974X1879180","DOI":"10.1177\/2473974X18791803","volume":"2","author":"PW Gidley","year":"2018","unstructured":"Gidley, P. W. et al. Contemporary opinions on intraoperative facial nerve monitoring. OTO Open 2, 2473974X18791803 (2018).","journal-title":"OTO Open"},{"key":"17732_CR25","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1159\/000442124","volume":"78","author":"O Guntinas-Lichius","year":"2016","unstructured":"Guntinas-Lichius, O. & Eisele, D. W. Facial nerve monitoring. Salivary Gland Neoplasms 78, 46\u201352 (2016).","journal-title":"Salivary Gland Neoplasms"},{"key":"17732_CR26","doi-asserted-by":"publisher","first-page":"e456","DOI":"10.1097\/MD.0000000000000456","volume":"94","author":"H-S Hsieh","year":"2015","unstructured":"Hsieh, H.-S., Wu, C.-M., Zhuo, M.-Y., Yang, C.-H. & Hwang, C.-F. Intraoperative facial nerve monitoring during cochlear implant surgery. Medicine (Baltimore) 94, e456 (2015).","journal-title":"Medicine (Baltimore)"},{"key":"17732_CR27","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1080\/14670100.2019.1625126","volume":"20","author":"MF Mandour","year":"2019","unstructured":"Mandour, M. F., Khalifa, M. A., Khalifa, H. M. A. & Amer, M. A. R. Iatrogenic facial nerve exposure in cochlear implant surgery: Incidence and clinical significance in the absence of intra-operative nerve monitoring. Cochlear Implants Int. 20, 250\u2013254 (2019).","journal-title":"Cochlear Implants Int."},{"key":"17732_CR28","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/MAO.0000000000000914","volume":"37","author":"J Ans\u00f3","year":"2016","unstructured":"Ans\u00f3, J. et al. A neuromonitoring approach to facial nerve preservation during image-guided robotic cochlear implantation. Otol. Neurotol. 37, 89\u201398 (2016).","journal-title":"Otol. Neurotol."},{"key":"17732_CR29","first-page":"11","volume":"31","author":"S Berrettini","year":"2011","unstructured":"Berrettini, S., de Vito, A., Bruschini, L., Passetti, S. & Forli, F. Facial nerve stimulation after cochlear implantation: Our experience. Acta Otorhinolaryngol Ital 31, 11\u201316 (2011).","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"17732_CR30","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/S0194-5998(98)70116-0","volume":"119","author":"SR Gold","year":"1998","unstructured":"Gold, S. R., Vicki, M., Kamerer, D. B. & Koconis, C. A. Fluoride treatment for facial nerve stimulation caused by cochlear implants in otosclerosis. Otolaryngol. Neck Surg. 119, 521\u2013523 (1998).","journal-title":"Otolaryngol. Neck Surg."},{"key":"17732_CR31","first-page":"394","volume":"15","author":"RP Muckle","year":"1994","unstructured":"Muckle, R. P. & Levine, S. C. Facial nerve stimulation produced by cochlear implants in patients with cochlear otosclerosis. Am. J. Otol. 15, 394\u2013398 (1994).","journal-title":"Am. J. Otol."},{"key":"17732_CR32","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000001440","volume":"38","author":"T Kamogashira","year":"2017","unstructured":"Kamogashira, T. et al. Prediction of intraoperative CSF gusher and postoperative facial nerve stimulation in patients with cochleovestibular malformations undergoing cochlear implantation surgery. Otol. Neurotol. 38, e114 (2017).","journal-title":"Otol. Neurotol."},{"key":"17732_CR33","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-020-06486-7","author":"IA Aljazeeri","year":"2020","unstructured":"Aljazeeri, I. A., Khurayzi, T., Al-Amro, M., Alzhrani, F. & Alsanosi, A. Evaluation of computed tomography parameters in patients with facial nerve stimulation post-cochlear implantation. Eur. Arch. Otorhinolaryngol. https:\/\/doi.org\/10.1007\/s00405-020-06486-7 (2020).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"17732_CR34","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1097\/MAO.0000000000001497","volume":"38","author":"JL Hatch","year":"2017","unstructured":"Hatch, J. L. et al. Can preoperative CT scans be used to predict facial nerve stimulation following CI?. Otol. Neurotol. 38, 1112\u20131117 (2017).","journal-title":"Otol. Neurotol."},{"key":"17732_CR35","doi-asserted-by":"publisher","first-page":"1168","DOI":"10.1097\/MAO.0b013e3181b12115","volume":"30","author":"JHM Frijns","year":"2009","unstructured":"Frijns, J. H. M., Kalkman, R. K. & Briaire, J. J. Stimulation of the facial nerve by intracochlear electrodes in otosclerosis: A computer modeling study. Otol. Neurotol. 30, 1168\u20131174 (2009).","journal-title":"Otol. Neurotol."},{"key":"17732_CR36","doi-asserted-by":"publisher","first-page":"e438","DOI":"10.1097\/MAO.0000000000001603","volume":"38","author":"A Bahmer","year":"2017","unstructured":"Bahmer, A., Adel, Y. & Baumann, U. Preventing facial nerve stimulation by triphasic pulse stimulation in cochlear implant users: Intraoperative recordings. Otol. Neurotol. 38, e438\u2013e444 (2017).","journal-title":"Otol. Neurotol."},{"key":"17732_CR37","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1097\/MAO.0000000000001156","volume":"37","author":"A Bahmer","year":"2016","unstructured":"Bahmer, A. & Baumann, U. The underlying mechanism of preventing facial nerve stimulation by triphasic pulse stimulation in cochlear implant users assessed with objective measure. Otol. Neurotol. 37, 1231\u20131237 (2016).","journal-title":"Otol. Neurotol."},{"key":"17732_CR38","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1007\/s12070-019-01649-3","volume":"71","author":"I Sefien","year":"2019","unstructured":"Sefien, I. & Hamada, S. Facial nerve stimulation as a complication of cochlear implantation. Indian J. Otolaryngol. Head Neck Surg. 71, 474\u2013479 (2019).","journal-title":"Indian J. Otolaryngol. Head Neck Surg."},{"key":"17732_CR39","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.3174\/ajnr.A3814","volume":"35","author":"MS Pearl","year":"2014","unstructured":"Pearl, M. S., Roy, A. & Limb, C. J. High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants. Am. J. Neuroradiol. 35, 1202\u20131208 (2014).","journal-title":"Am. J. Neuroradiol."},{"key":"17732_CR40","first-page":"49","volume":"21","author":"J Xu","year":"2000","unstructured":"Xu, J., Xu, S.-A., Cohen, L. T. & Clark, G. M. Cochlear view: Postoperative radiography for cochlear implantation. Otol. Neurotol. 21, 49\u201356 (2000).","journal-title":"Otol. Neurotol."},{"key":"17732_CR41","doi-asserted-by":"publisher","first-page":"110266","DOI":"10.1016\/j.ijporl.2020.110266","volume":"138","author":"D Ehrmann-M\u00fcller","year":"2020","unstructured":"Ehrmann-M\u00fcller, D. et al. Cochlear implantation in children without preoperative computed tomography diagnostics. Analysis of procedure and rate of complications. Int. J. Pediatr. Otorhinolaryngol. 138, 110266 (2020).","journal-title":"Int. J. Pediatr. Otorhinolaryngol."},{"key":"17732_CR42","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s00411-013-0491-8","volume":"53","author":"N Journy","year":"2014","unstructured":"Journy, N. et al. Predicted cancer risks induced by computed tomography examinations during childhood, by a quantitative risk assessment approach. Radiat. Environ. Biophys. 53, 39\u201354 (2014).","journal-title":"Radiat. Environ. Biophys."},{"key":"17732_CR43","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","volume":"167","author":"DL Miglioretti","year":"2013","unstructured":"Miglioretti, D. L. et al. The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatr. 167, 700\u2013707 (2013).","journal-title":"JAMA Pediatr."},{"key":"17732_CR44","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","volume":"380","author":"MS Pearce","year":"2012","unstructured":"Pearce, M. S. et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: A retrospective cohort study. Lancet 380, 499\u2013505 (2012).","journal-title":"Lancet"},{"key":"17732_CR45","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000002777","volume":"41","author":"NA George-Jones","year":"2020","unstructured":"George-Jones, N. A., Tolisano, A. M., Kutz, J. W. J., Isaacson, B. & Hunter, J. B. Comparing cochlear duct lengths between CT and MR images using an otological surgical planning software. Otol. Neurotol. 41, e1118 (2020).","journal-title":"Otol. Neurotol."},{"key":"17732_CR46","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1080\/14670100.2018.1549186","volume":"20","author":"R Nash","year":"2019","unstructured":"Nash, R., Otero, S. & Lavy, J. Use of MRI to determine cochlear duct length in patients undergoing cochlear implantation. Cochlear Implants Int. 20, 57\u201361 (2019).","journal-title":"Cochlear Implants Int."},{"key":"17732_CR47","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1111\/1754-9485.12962","volume":"63","author":"J Haneda","year":"2019","unstructured":"Haneda, J., Ishikawa, K. & Okamoto, K. Better continuity of the facial nerve demonstrated in the temporal bone on three-dimensional T1-weighted imaging with volume isotropic turbo spin echo acquisition than that with fast field echo at 3.0 tesla MRI. J. Med. Imaging Radiat. Oncol. 63, 745\u2013750 (2019).","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"17732_CR48","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/RMR.0000000000000044","volume":"24","author":"K Fruauff","year":"2015","unstructured":"Fruauff, K., Coffey, K., Chazen, J. L. & Phillips, C. D. Temporal bone imaging. Top. Magn. Reson. Imaging 24, 39\u201355 (2015).","journal-title":"Top. Magn. Reson. Imaging"},{"key":"17732_CR49","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1097\/MAO.0b013e318248ea86","volume":"33","author":"A Radeloff","year":"2012","unstructured":"Radeloff, A. et al. Intraoperative monitoring using cochlear microphonics in cochlear implant patients with residual hearing. Otol. Neurotol. 33, 348\u2013354 (2012).","journal-title":"Otol. Neurotol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17732-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17732-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17732-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T05:18:45Z","timestamp":1669353525000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17732-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,4]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["17732"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-17732-9","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,4]]},"assertion":[{"value":"20 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13426"}}