{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T06:12:35Z","timestamp":1793081555767,"version":"4.5.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,12]],"date-time":"2022-08-12T00:00:00Z","timestamp":1660262400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,12]],"date-time":"2022-08-12T00:00:00Z","timestamp":1660262400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In this study, we retrospectively evaluated the deviation from the planned axis of 3 Toric intraocular lenses (TIOL). Included in the study 190 eyes, operated by two surgeons using two different manual marking techniques. The patients were implanted with either AcrySof IQ Toric SN6AT (Alcon) (n\u2009=\u200990), POD FT (PhysIOL) (n\u2009=\u200950), or TECNIS Symfony Toric (J&amp;J) (n\u2009=\u200950). At least 1 month postoperatively, the IOL was photographed, and the axis was measured using a designed software. The difference between the planned and actual axis was defined as axis deviation. The effect of IOL type, astigmatism direction, and marking techniques on the average degree and direction of the IOL deviation were evaluated and compared. There was no significant difference in the average deviation between the IOLs (TECNIS Symfony: 4.03\u00b0\u2009\u00b1\u20094.34, POD FT: 3.52\u00b0\u2009\u00b1\u20093.38, and SN6AT: 4.24\u00b0\u2009\u00b1\u20094.10), and its direction (55.8%, 39.0%, and 56.6% clockwise (CW) deviation, respectively). With the rule, astigmatism had significantly more CW deviation compared with against the rule and oblique astigmatism (64.3%, 43.8%, and 41.7%, respectively, P\u2009=\u20090.027), but the average deviation was similar. The marking techniques did not influence the degree or direction of the deviation.<\/jats:p>","DOI":"10.1038\/s41598-022-17811-x","type":"journal-article","created":{"date-parts":[[2022,8,12]],"date-time":"2022-08-12T15:06:01Z","timestamp":1660316761000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Deviation from the planned axis of three toric intraocular lenses"],"prefix":"10.1038","volume":"12","author":[{"given":"Shira","family":"Sheen-Ophir","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olga","family":"Reitblat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adi","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ehud I.","family":"Assia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy","family":"Kleinmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,12]]},"reference":[{"issue":"1","key":"17811_CR1","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jcrs.2008.09.027","volume":"35","author":"T Ferrer-Blasco","year":"2009","unstructured":"Ferrer-Blasco, T., Mont\u00e9s-Mic\u00f3, R., Peixoto-de-Matos, S. C., Gonz\u00e1lez-M\u00e9ijome, J. M. & Cervi\u00f1o, A. Prevalence of corneal astigmatism before cataract surgery. J. Cataract Refract. Surg. 35(1), 70\u201375. https:\/\/doi.org\/10.1016\/j.jcrs.2008.09.027 (2009).","journal-title":"J. Cataract Refract. Surg."},{"issue":"3","key":"17811_CR2","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/s0002-9394(14)74917-7","volume":"90","author":"KJ Hoffer","year":"1980","unstructured":"Hoffer, K. J. Biometry of 7500 cataractous eyes. Am. J. Ophthalmol. 90(3), 360\u2013368. https:\/\/doi.org\/10.1016\/s0002-9394(14)74917-7 (1980).","journal-title":"Am. J. Ophthalmol."},{"issue":"4","key":"17811_CR3","doi-asserted-by":"publisher","first-page":"333","DOI":"10.3928\/1081-597X-19920701-19","volume":"8","author":"MD Wagoner","year":"1992","unstructured":"Wagoner, M. D. Sutureless cataract surgery: An evolution toward minimally invasive technique. J. Refract. Surg. 8(4), 333\u2013333. https:\/\/doi.org\/10.3928\/1081-597X-19920701-19 (1992).","journal-title":"J. Refract. Surg."},{"issue":"8","key":"17811_CR4","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","volume":"43","author":"L Wang","year":"2017","unstructured":"Wang, L., Koch, D. D., Hill, W. & Abulafia, A. Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes. J. Cataract Refract Surg. 43(8), 999\u20131002. https:\/\/doi.org\/10.1016\/j.jcrs.2017.08.003 (2017).","journal-title":"J. Cataract Refract Surg."},{"issue":"9","key":"17811_CR5","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1016\/j.ophtha.2017.05.025","volume":"124","author":"Y Inoue","year":"2017","unstructured":"Inoue, Y., Takehara, H. & Oshika, T. Axis misalignment of toric intraocular lens: Placement error and postoperative rotation. Ophthalmology 124(9), 1424\u20131425. https:\/\/doi.org\/10.1016\/j.ophtha.2017.05.025 (2017).","journal-title":"Ophthalmology"},{"issue":"9","key":"17811_CR6","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1016\/j.ophtha.2018.02.012","volume":"125","author":"BS Lee","year":"2018","unstructured":"Lee, B. S. & Chang, D. F. Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes. Ophthalmology 125(9), 1325\u20131331. https:\/\/doi.org\/10.1016\/j.ophtha.2018.02.012 (2018).","journal-title":"Ophthalmology"},{"issue":"11","key":"17811_CR7","doi-asserted-by":"publisher","first-page":"2104","DOI":"10.1016\/j.ophtha.2010.07.033","volume":"117","author":"E Holland","year":"2010","unstructured":"Holland, E. et al. The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: A randomized, subject-masked, parallel-group, 1-year study. Ophthalmology 117(11), 2104\u20132111. https:\/\/doi.org\/10.1016\/j.ophtha.2010.07.033 (2010).","journal-title":"Ophthalmology"},{"issue":"7","key":"17811_CR8","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1080\/02713683.2018.1458881","volume":"43","author":"L Asena","year":"2018","unstructured":"Asena, L., Akman, A., G\u00fcng\u00f6r, S. G. & Dursun, A. D. Comparison of keratometry obtained by a swept source OCT-based biometer with a standard optical biometer and scheimpflug imaging. Curr. Eye Res. 43(7), 882\u2013888 (2018).","journal-title":"Curr. Eye Res."},{"issue":"2","key":"17811_CR9","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel, L. et al. Toric intraocular lenses in the correction of astigmatism during cataract surgery: A systematic review and meta-analysis. Ophthalmology 123(2), 275\u2013286. https:\/\/doi.org\/10.1016\/j.ophtha.2015.10.002 (2016).","journal-title":"Ophthalmology"},{"key":"17811_CR10","doi-asserted-by":"publisher","unstructured":"Matthias, K.J., Von Sonnleithner, C., Gonnermann, J., Anna-Karina, B. Maier, Necip Torun, Eckart Bertelmann, 2013. Influence of Biometric Parameters on Rotational Stability of Toric IOLs. Accessed April 9, 2019. https:\/\/doi.org\/10.5301\/ejo.5000316","DOI":"10.5301\/ejo.5000316"},{"issue":"1","key":"17811_CR11","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ophtha.2014.06.027","volume":"122","author":"KL Waltz","year":"2015","unstructured":"Waltz, K. L., Featherstone, K., Tsai, L. & Trentacost, D. Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism. Ophthalmology 122(1), 39\u201347. https:\/\/doi.org\/10.1016\/j.ophtha.2014.06.027 (2015).","journal-title":"Ophthalmology"},{"issue":"10","key":"17811_CR12","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.1016\/j.jcrs.2014.01.044","volume":"40","author":"T Miyake","year":"2014","unstructured":"Miyake, T. et al. Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism. J. Cataract Refract Surg. 40(10), 1654\u20131660. https:\/\/doi.org\/10.1016\/j.jcrs.2014.01.044 (2014).","journal-title":"J. Cataract Refract Surg."},{"key":"17811_CR13","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1471-2415-8-8","volume":"8","author":"B Zuberbuhler","year":"2008","unstructured":"Zuberbuhler, B., Signer, T., Gale, R. & Haefliger, E. Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study. BMC Ophthalmol. 8, 8. https:\/\/doi.org\/10.1186\/1471-2415-8-8 (2008).","journal-title":"BMC Ophthalmol."},{"issue":"3","key":"17811_CR14","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1159\/000368658","volume":"53","author":"A Harrer","year":"2015","unstructured":"Harrer, A., Hirnschall, N., Maedel, S. & Findl, O. Influence of the overall intraocular lens diameter on rotational stability. Ophthalm. Res. 53(3), 117\u2013121. https:\/\/doi.org\/10.1159\/000368658 (2015).","journal-title":"Ophthalm. Res."},{"issue":"4","key":"17811_CR15","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1177\/1120672118795065","volume":"29","author":"F Poyales","year":"2019","unstructured":"Poyales, F., Garz\u00f3n, N., Pizarro, D., Cobreces, S. & Hern\u00e1ndez, A. Stability and visual outcomes yielded by three intraocular trifocal lenses with same optical zone design but differing material or toricity. Eur. J. Ophthalmol. 29(4), 417\u2013425. https:\/\/doi.org\/10.1177\/1120672118795065 (2019).","journal-title":"Eur. J. Ophthalmol."},{"issue":"2","key":"17811_CR16","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1136\/bjophthalmol-2017-311797","volume":"103","author":"D Schartm\u00fcller","year":"2019","unstructured":"Schartm\u00fcller, D., Schriefl, S., Schwarzenbacher, L., Leydolt, C. & Menapace, R. True rotational stability of a single-piece hydrophobic intraocular lens. Br. J. Ophthalmol. 103(2), 186\u2013190. https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311797 (2019).","journal-title":"Br. J. Ophthalmol."},{"issue":"7","key":"17811_CR17","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1016\/S0886-3350(00)00317-5","volume":"26","author":"I Ruhswurm","year":"2000","unstructured":"Ruhswurm, I. et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J. Cataract Refract Surg. 26(7), 1022\u20131027. https:\/\/doi.org\/10.1016\/S0886-3350(00)00317-5 (2000).","journal-title":"J. Cataract Refract Surg."},{"issue":"2","key":"17811_CR18","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/S0886-3350(01)01035-5","volume":"28","author":"JS Till","year":"2002","unstructured":"Till, J. S., Yoder, P. R., Wilcox, T. K. & Spielman, J. L. Toric intraocular lens implantation: 100 consecutive cases. J. Cataract Refract Surg. 28(2), 295\u2013301. https:\/\/doi.org\/10.1016\/S0886-3350(01)01035-5 (2002).","journal-title":"J. Cataract Refract Surg."},{"issue":"8","key":"17811_CR19","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/j.jcrs.2011.02.024","volume":"37","author":"N Visser","year":"2011","unstructured":"Visser, N. et al. Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J. Cataract Refract Surg. 37(8), 1394\u20131402. https:\/\/doi.org\/10.1016\/j.jcrs.2011.02.024 (2011).","journal-title":"J. Cataract Refract Surg."},{"key":"17811_CR20","doi-asserted-by":"publisher","first-page":"2094","DOI":"10.1016\/j.jcrs.2012.07.039","volume":"38","author":"N Popp","year":"2012","unstructured":"Popp, N., Hirnschall, N., Maedel, S. & Findl, O. Evaluation of 4 corneal astigmatic marking methods. J. Cataract Refract Surg. 38, 2094\u20132099 (2012).","journal-title":"J. Cataract Refract Surg."},{"issue":"10","key":"17811_CR21","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.jcrs.2009.05.024","volume":"35","author":"MJ Saldanha","year":"2009","unstructured":"Saldanha, M. J., Benjamin, L. & Patel, C. K. Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens. J. Cataract Refract Surg. 35(10), 1751\u20131755. https:\/\/doi.org\/10.1016\/j.jcrs.2009.05.024 (2009).","journal-title":"J. Cataract Refract Surg."},{"issue":"2","key":"17811_CR22","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","volume":"100","author":"X Zhu","year":"2016","unstructured":"Zhu, X., He, W., Zhang, K. & Lu, Y. Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses. Br. J. Ophthalmol. 100(2), 263\u2013268. https:\/\/doi.org\/10.1136\/bjophthalmol-2015-306656 (2016).","journal-title":"Br. J. Ophthalmol."},{"issue":"1","key":"17811_CR23","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcrs.2011.08.028","volume":"38","author":"GD Shah","year":"2012","unstructured":"Shah, G. D. et al. Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bag. J. Cataract Refract Surg. 38(1), 54\u201359. https:\/\/doi.org\/10.1016\/j.jcrs.2011.08.028 (2012).","journal-title":"J. Cataract Refract Surg."},{"issue":"11","key":"17811_CR24","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1016\/S0161-6420(99)90504-3","volume":"106","author":"CK Patel","year":"1999","unstructured":"Patel, C. K., Ormonde, S., Rosen, P. H. & Bron, A. J. Postoperative intraocular lens rotation: A randomized comparison of plate and loop haptic implants. Ophthalmology 106(11), 2190\u20132195. https:\/\/doi.org\/10.1016\/S0161-6420(99)90504-3 (1999) (discussion 2196).","journal-title":"Ophthalmology"},{"issue":"3","key":"17811_CR25","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/j.jcrs.2004.07.019","volume":"31","author":"A Viestenz","year":"2005","unstructured":"Viestenz, A., Seitz, B. & Langenbucher, A. Evaluating the eye\u2019s rotational stability during standard photography: Effect on determining the axial orientation of toric intraocular lenses. J. Cataract Refract Surg. 31(3), 557\u2013561. https:\/\/doi.org\/10.1016\/j.jcrs.2004.07.019 (2005).","journal-title":"J. Cataract Refract Surg."},{"issue":"5","key":"17811_CR26","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.jcrs.2007.01.030","volume":"33","author":"F Weinand","year":"2007","unstructured":"Weinand, F. et al. Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation control. J. Cataract Refract Surg. 33(5), 800\u2013803. https:\/\/doi.org\/10.1016\/j.jcrs.2007.01.030 (2007).","journal-title":"J. Cataract Refract Surg."},{"issue":"10","key":"17811_CR27","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1016\/s0886-3350(00)00442-9","volume":"26","author":"TM Nguyen","year":"2000","unstructured":"Nguyen, T. M. & Miller, K. M. Digital overlay technique for documenting toric intraocular lens axis orientation. J. Cataract Refract Surg. 26(10), 1496\u20131504. https:\/\/doi.org\/10.1016\/s0886-3350(00)00442-9 (2000).","journal-title":"J. Cataract Refract Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17811-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17811-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17811-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T07:24:39Z","timestamp":1669361079000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-17811-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,12]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["17811"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-17811-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,12]]},"assertion":[{"value":"12 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13760"}}