{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T23:36:15Z","timestamp":1778196975297,"version":"3.51.4"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T00:00:00Z","timestamp":1662336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T00:00:00Z","timestamp":1662336000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Current dynamic MRA techniques are limited by temporal resolution and signal-to-noise penalties. GRASP, a fast and flexible MRI technique combining compressed-sensing, parallel imaging, and golden-angle radial sampling, acquires volumetric data continuously and can be reconstructed post hoc for user-defined applications. We describe a custom pipeline to retrospectively reconstruct ultrahigh temporal resolution, dynamic MRA from GRASP imaging obtained in the course of routine practice. GRASP scans were reconstructed using a custom implementation of the GRASP algorithm and post-processed with MeVisLab (MeVis Medical Solutions AG, Germany). Twenty consecutive examinations were scored by three neuroradiologists for angiographic quality of specific vascular segments and imaging artifacts using a 4-point scale. Unsubtracted images, baseline-subtracted images, and a temporal gradient dataset were available in 2D and 3D reconstructions. Distinct arterial and capillary phases were identified in all reconstructions, with a median of 2 frames (IQR1-3 and 2\u20133, respectively). Median rating for vascular segments was 3 (excellent) in all reconstructions and for nearly all segments, with excellent intraclass correlation (range 0.91\u20131.00). No cases were degraded by artifacts. GRASP-MRI obtained in routine practice can be seamlessly repurposed to produce high quality 4D MRA with 1\u20132-s resolved isotropic cerebrovascular angiography. Further exploration into diagnostic accuracy in disease-specific applications is warranted.<\/jats:p>","DOI":"10.1038\/s41598-022-18191-y","type":"journal-article","created":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T18:02:33Z","timestamp":1662400953000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Highly time-resolved 4D MR angiography using golden-angle radial sparse parallel (GRASP) MRI"],"prefix":"10.1038","volume":"12","author":[{"given":"Adam E.","family":"Goldman-Yassen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eytan","family":"Raz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria J.","family":"Borja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Duan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Derman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddhant","family":"Dogra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai Tobias","family":"Block","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seena","family":"Dehkharghani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,9,5]]},"reference":[{"key":"18191_CR1","doi-asserted-by":"publisher","first-page":"W613","DOI":"10.2214\/AJR.10.4227","volume":"196","author":"KA Blackham","year":"2011","unstructured":"Blackham, K. A. et al. Applications of time-resolved MR angiography. AJR Am. J. Roentgenol. 196, W613-620. https:\/\/doi.org\/10.2214\/AJR.10.4227 (2011).","journal-title":"AJR Am. J. Roentgenol."},{"key":"18191_CR2","doi-asserted-by":"publisher","first-page":"2112","DOI":"10.3174\/ajnr.A4008","volume":"35","author":"SR Boddu","year":"2014","unstructured":"Boddu, S. R., Tong, F. C., Dehkharghani, S., Dion, J. E. & Saindane, A. M. Contrast-enhanced time-resolved MRA for follow-up of intracranial aneurysms treated with the pipeline embolization device. AJNR Am. J. Neuroradiol. 35, 2112\u20132118. https:\/\/doi.org\/10.3174\/ajnr.A4008 (2014).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"18191_CR3","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1136\/neurintsurg-2013-010981","volume":"7","author":"AM Saindane","year":"2015","unstructured":"Saindane, A. M., Boddu, S. R., Tong, F. C., Dehkharghani, S. & Dion, J. E. Contrast-enhanced time-resolved MRA for pre-angiographic evaluation of suspected spinal dural arterial venous fistulas. J. Neurointerv. Surg. 7, 135\u2013140. https:\/\/doi.org\/10.1136\/neurintsurg-2013-010981 (2015).","journal-title":"J. Neurointerv. Surg."},{"key":"18191_CR4","doi-asserted-by":"publisher","first-page":"E3","DOI":"10.3171\/2019.9.FOCUS19627","volume":"47","author":"JA Grossberg","year":"2019","unstructured":"Grossberg, J. A., Howard, B. M. & Saindane, A. M. The use of contrast-enhanced, time-resolved magnetic resonance angiography in cerebrovascular pathology. Neurosurg. Focus 47, E3. https:\/\/doi.org\/10.3171\/2019.9.FOCUS19627 (2019).","journal-title":"Neurosurg. Focus"},{"key":"18191_CR5","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1002\/jmri.23646","volume":"36","author":"TM Grist","year":"2012","unstructured":"Grist, T. M., Mistretta, C. A., Strother, C. M. & Turski, P. A. Time-resolved angiography: Past, present, and future. J. Magn. Reason. Imaging 36, 1273\u20131286. https:\/\/doi.org\/10.1002\/jmri.23646 (2012).","journal-title":"J. Magn. Reason. Imaging"},{"key":"18191_CR6","doi-asserted-by":"publisher","first-page":"450","DOI":"10.3174\/ajnr.A3693","volume":"35","author":"S Dehkharghani","year":"2014","unstructured":"Dehkharghani, S., Kang, J. & Saindane, A. M. Improved quality and diagnostic confidence achieved by use of dose-reduced gadolinium blood-pool agents for time-resolved intracranial MR angiography. AJNR Am. J. Neuroradiol. 35, 450\u2013456. https:\/\/doi.org\/10.3174\/ajnr.A3693 (2014).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"18191_CR7","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1002\/mrm.1910370306","volume":"37","author":"J Hennig","year":"1997","unstructured":"Hennig, J., Scheffler, K., Laubenberger, J. & Strecker, R. Time-resolved projection angiography after bolus injection of contrast agent. Magn. Reason. Med. 37, 341\u2013345 (1997).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR8","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1002\/mrm.1910360304","volume":"36","author":"FR Korosec","year":"1996","unstructured":"Korosec, F. R., Frayne, R., Grist, T. M. & Mistretta, C. A. Time-resolved contrast-enhanced 3D MR angiography. Magn. Reason. Med. 36, 345\u2013351 (1996).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR9","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1002\/mrm.21901","volume":"61","author":"T Song","year":"2009","unstructured":"Song, T. et al. Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography. Magn. Reason. Med. 61, 1242\u20131248. https:\/\/doi.org\/10.1002\/mrm.21901 (2009).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR10","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1002\/mrm.22434","volume":"64","author":"CR Haider","year":"2010","unstructured":"Haider, C. R. et al. Max CAPR: High-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds. Magn. Reason. Med. 64, 1171\u20131181. https:\/\/doi.org\/10.1002\/mrm.22434 (2010).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR11","first-page":"743","volume":"26","author":"T Gu","year":"2005","unstructured":"Gu, T. et al. PC VIPR: A high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. AJNR Am. J. Neuroradiol. 26, 743\u2013749 (2005).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"18191_CR12","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.3174\/ajnr.A4245","volume":"36","author":"W Chang","year":"2015","unstructured":"Chang, W. et al. Fast contrast-enhanced 4D MRA and 4D flow MRI using constrained reconstruction (HYPRFlow): Potential applications for brain arteriovenous malformations. AJNR Am. J. Neuroradiol. 36, 1049\u20131055. https:\/\/doi.org\/10.3174\/ajnr.A4245 (2015).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"18191_CR13","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1002\/mrm.25414","volume":"74","author":"S Rapacchi","year":"2015","unstructured":"Rapacchi, S. et al. Reducing view-sharing using compressed sensing in time-resolved contrast-enhanced magnetic resonance angiography. Magn. Reason. Med. 74, 474\u2013481. https:\/\/doi.org\/10.1002\/mrm.25414 (2015).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR14","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1080\/02841850701326958","volume":"48","author":"JO Heidenreich","year":"2007","unstructured":"Heidenreich, J. O. et al. Assessment of 3D-TOF-MRA at 3.0 Tesla in the characterization of the angioarchitecture of cerebral arteriovenous malformations: A preliminary study. Acta Radiol. 48, 678\u2013686. https:\/\/doi.org\/10.1080\/02841850701326958 (2007).","journal-title":"Acta Radiol."},{"key":"18191_CR15","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1002\/mrm.24980","volume":"72","author":"L Feng","year":"2014","unstructured":"Feng, L. et al. Golden-angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn. Reason. Med. 72, 707\u2013717. https:\/\/doi.org\/10.1002\/mrm.24980 (2014).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR16","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000586","author":"J Weiss","year":"2019","unstructured":"Weiss, J. et al. Assessment of hepatic perfusion using GRASP MRI: Bringing liver MRI on a new level. Investig. Radiol. https:\/\/doi.org\/10.1097\/RLI.0000000000000586 (2019).","journal-title":"Investig. Radiol."},{"key":"18191_CR17","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.mri.2019.03.015","volume":"60","author":"N Hainc","year":"2019","unstructured":"Hainc, N. et al. Golden-angle radial sparse parallel (GRASP) MRI in clinical routine detection of pituitary microadenomas: First experience and feasibility. Magn. Reason. Imaging 60, 38\u201343. https:\/\/doi.org\/10.1016\/j.mri.2019.03.015 (2019).","journal-title":"Magn. Reason. Imaging"},{"key":"18191_CR18","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1148\/radiol.2018180556","volume":"290","author":"DJ Winkel","year":"2019","unstructured":"Winkel, D. J. et al. Compressed sensing radial sampling MRI of prostate perfusion: Utility for detection of prostate cancer. Radiology 290, 702\u2013708. https:\/\/doi.org\/10.1148\/radiol.2018180556 (2019).","journal-title":"Radiology"},{"key":"18191_CR19","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.3174\/ajnr.A6055","volume":"40","author":"JL Mogen","year":"2019","unstructured":"Mogen, J. L. et al. Dynamic contrast-enhanced MRI to differentiate parotid neoplasms using golden-angle radial sparse parallel imaging. AJNR Am. J. Neuroradiol. 40, 1029\u20131036. https:\/\/doi.org\/10.3174\/ajnr.A6055 (2019).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"18191_CR20","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1002\/jmri.25530","volume":"45","author":"L Heacock","year":"2017","unstructured":"Heacock, L. et al. Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity. J. Magn. Reason. Imaging 45, 1746\u20131752. https:\/\/doi.org\/10.1002\/jmri.25530 (2017).","journal-title":"J. Magn. Reason. Imaging"},{"key":"18191_CR21","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1002\/mrm.24256","volume":"69","author":"GR Lee","year":"2013","unstructured":"Lee, G. R., Seiberlich, N., Sunshine, J. L., Carroll, T. J. & Griswold, M. A. Rapid time-resolved magnetic resonance angiography via a multiecho radial trajectory and GraDeS reconstruction. Magn. Reason. Med. 69, 346\u2013359. https:\/\/doi.org\/10.1002\/mrm.24256 (2013).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR22","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1016\/j.mri.2015.12.030","volume":"34","author":"Y Zhu","year":"2016","unstructured":"Zhu, Y. et al. GOCART: GOlden-angle CArtesian randomized time-resolved 3D MRI. Magn. Reason. Imaging 34, 940\u2013950. https:\/\/doi.org\/10.1016\/j.mri.2015.12.030 (2016).","journal-title":"Magn. Reason. Imaging"},{"key":"18191_CR23","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1002\/mrm.22892","volume":"66","author":"JD Trzasko","year":"2011","unstructured":"Trzasko, J. D. et al. Sparse-CAPR: Highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing. Magn. Reason. Med. 66, 1019\u20131032. https:\/\/doi.org\/10.1002\/mrm.22892 (2011).","journal-title":"Magn. Reason. Med."},{"key":"18191_CR24","doi-asserted-by":"publisher","first-page":"87","DOI":"10.13104\/jksmrm.2014.18.2.87","volume":"18","author":"KT Block","year":"2014","unstructured":"Block, K. T. et al. Towards routine clinical use of radial stack-of-stars 3D gradient-echo sequences for reducing motion sensitivity. Investig. Magn. Reason. Imaging 18, 87\u2013106. https:\/\/doi.org\/10.13104\/jksmrm.2014.18.2.87 (2014).","journal-title":"Investig. Magn. Reason. Imaging"},{"key":"18191_CR25","doi-asserted-by":"publisher","first-page":"W701","DOI":"10.2214\/AJR.14.13435","volume":"204","author":"S Dehkharghani","year":"2015","unstructured":"Dehkharghani, S., Qiu, D., Albin, L. S. & Saindane, A. M. Dose reduction in contrast-enhanced cervical MR angiography: Field strength dependency of vascular signal intensity, contrast administration, and arteriographic quality. AJR Am. J. Roentgenol. 204, W701-706. https:\/\/doi.org\/10.2214\/AJR.14.13435 (2015).","journal-title":"AJR Am. J. Roentgenol."},{"key":"18191_CR26","doi-asserted-by":"publisher","first-page":"621","DOI":"10.2214\/AJR.16.16049","volume":"207","author":"S Dehkharghani","year":"2016","unstructured":"Dehkharghani, S., Williams, T. R. 3rd., Qiu, D. & Saindane, A. M. Effects of height and blood volume on venous enhancement after gadolinium-based contrast administration in MR venography: A paradigm challenge and implications for clinical imaging. AJR Am. J. Roentgenol. 207, 621\u2013627. https:\/\/doi.org\/10.2214\/AJR.16.16049 (2016).","journal-title":"AJR Am. J. Roentgenol."},{"key":"18191_CR27","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012 (2016).","journal-title":"J. Chiropr. Med."},{"key":"18191_CR28","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/RLI.0b013e318271869c","volume":"48","author":"H Chandarana","year":"2013","unstructured":"Chandarana, H. et al. Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling. Investig. Radiol. 48, 10\u201316. https:\/\/doi.org\/10.1097\/RLI.0b013e318271869c (2013).","journal-title":"Investig. Radiol."},{"key":"18191_CR29","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1148\/radiol.2021202734","volume":"298","author":"S Dehkharghani","year":"2021","unstructured":"Dehkharghani, S. et al. High-performance automated anterior circulation CT angiographic clot detection in acute stroke: A multireader comparison. Radiology 298, 665\u2013670. https:\/\/doi.org\/10.1148\/radiol.2021202734 (2021).","journal-title":"Radiology"},{"key":"18191_CR30","doi-asserted-by":"publisher","first-page":"2790","DOI":"10.1161\/STROKEAHA.119.026259","volume":"50","author":"SA Amukotuwa","year":"2019","unstructured":"Amukotuwa, S. A. et al. Automated detection of intracranial large vessel occlusions on computed tomography angiography: A single center experience. Stroke 50, 2790\u20132798. https:\/\/doi.org\/10.1161\/STROKEAHA.119.026259 (2019).","journal-title":"Stroke"},{"key":"18191_CR31","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/01.rli.0000197668.44926.f7","volume":"41","author":"J Pintaske","year":"2006","unstructured":"Pintaske, J. et al. Relaxivity of gadopentetate dimeglumine (Magnevist), gadobutrol (Gadovist), and gadobenate dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Investig. Radiol. 41, 213\u2013221. https:\/\/doi.org\/10.1097\/01.rli.0000197668.44926.f7 (2006).","journal-title":"Investig. Radiol."},{"key":"18191_CR32","doi-asserted-by":"publisher","first-page":"e190205","DOI":"10.1148\/ryct.2020190205","volume":"2","author":"H Haji-Valizadeh","year":"2020","unstructured":"Haji-Valizadeh, H. et al. Rapid reconstruction of four-dimensional MR angiography of the thoracic aorta using a convolutional neural network. Radiol. Cardiothorac. Imaging 2, e190205. https:\/\/doi.org\/10.1148\/ryct.2020190205 (2020).","journal-title":"Radiol. Cardiothorac. Imaging"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-18191-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-18191-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-18191-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T18:04:46Z","timestamp":1662401086000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-18191-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,5]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["18191"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-18191-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,5]]},"assertion":[{"value":"21 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"K.T.B. holds a patent for GRASP MRI, with no royalties or reimbursements received. The authors report no other relevant conflicts of interest. S. De. discloses modest past travel and research support by iSchemaView (Menlo Park CA, USA) and scientific consulting with Regeneron (Tarrytown, NY, USA), both unrelated to this work.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15099"}}