{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T02:26:01Z","timestamp":1778639161215,"version":"3.51.4"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T00:00:00Z","timestamp":1664928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T00:00:00Z","timestamp":1664928000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cilia motion is an indicator of pathological-ciliary function, however current diagnosis relies on biopsies. In this paper, we propose an innovative approach for sensing cilia motility. We present an endoscopic configuration for measuring the motion frequency of cilia in the nasal cavity. The technique is based on temporal tracking of the reflected spatial distribution of defocused speckle patterns while illuminating the cilia with a laser. The setup splits the optical signal into two channels; One imaging channel is for the visualization of the physician and another is, defocusing channel, to capture the speckles. We present in-vivo measurements from healthy subjects undergoing endoscopic examination. We found an average motion frequency of around 7.3\u00a0Hz and 9.8\u00a0Hz in the antero-posterior nasal mucus (an area rich in cilia), which matches the normal cilia range of 7\u201316\u00a0Hz. Quantitative and precise measurements of cilia vibration will optimize the diagnosis and treatment of pathological-ciliary function. This method is simple, minimally invasive, inexpensive, and promising to distinguish between normal and ciliary dysfunction.<\/jats:p>","DOI":"10.1038\/s41598-022-20557-1","type":"journal-article","created":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T11:10:41Z","timestamp":1664968241000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Non-contact optical in-vivo sensing of cilia motion by analyzing speckle patterns"],"prefix":"10.1038","volume":"12","author":[{"given":"Doron","family":"Duadi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nadav","family":"Shabairou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adi","family":"Primov-Fever","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zeev","family":"Zalevsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,10,5]]},"reference":[{"key":"20557_CR1","doi-asserted-by":"publisher","first-page":"98","DOI":"10.18287\/JBPE-2015-1-2-98","volume":"1","author":"VV Tuchin","year":"2015","unstructured":"Tuchin, V. V. Tissue optics and photonics: Light-tissue interaction. J. Biomed. Photon. Eng. 1, 98\u2013134 (2015).","journal-title":"J. Biomed. Photon. Eng."},{"key":"20557_CR2","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1016\/S1542-3565(04)00345-3","volume":"2","author":"TD Wang","year":"2004","unstructured":"Wang, T. D. & Van Dam, J. Optical biopsy: A new frontier in endoscopic detection and diagnosis. Clin. Gastroenterol. Hepatol. 2, 744\u2013753 (2004).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"20557_CR3","doi-asserted-by":"publisher","first-page":"39","DOI":"10.21037\/tgh.2019.12.06","volume":"5","author":"R Singh","year":"2020","unstructured":"Singh, R. et al. Chromoendoscopy: Role in modern endoscopic imaging. Transl. Gastroenterol. Hepatol. 5, 39 (2020).","journal-title":"Transl. Gastroenterol. Hepatol."},{"key":"20557_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/jid.2012.429","volume":"132","author":"A Nwaneshiudu","year":"2012","unstructured":"Nwaneshiudu, A. et al. Introduction to confocal microscopy. J. Investig. Dermatol. 132, 1\u20135 (2012).","journal-title":"J. Investig. Dermatol."},{"key":"20557_CR5","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.1364\/BOE.8.002405","volume":"8","author":"MJ Gora","year":"2017","unstructured":"Gora, M. J., Suter, M. J., Tearney, G. J. & Li, X. Endoscopic optical coherence tomography: Technologies and clinical applications. Biomed. Opt. Express 8, 2405\u20132444 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR6","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.gie.2010.11.006","volume":"73","author":"L-MWK Song","year":"2011","unstructured":"Song, L.-M.W.K. et al. Autofluorescence imaging. Gastrointest. Endosc. 73, 647\u2013650 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"20557_CR7","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1055\/s-2005-921114","volume":"38","author":"K Kuznetsov","year":"2006","unstructured":"Kuznetsov, K., Lambert, R. & Rey, J.-F. Narrow-band imaging: Potential and limitations. Endoscopy 38, 76\u201381 (2006).","journal-title":"Endoscopy"},{"key":"20557_CR8","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1053\/tgie.2003.50004","volume":"5","author":"JW Tunnell","year":"2003","unstructured":"Tunnell, J. W., Haka, A. S., McGee, S. A., Mirkovic, J. & Feld, M. S. Diagnostic tissue spectroscopy and its applications to gastrointestinal endoscopy. Tech. Gastrointest. Endosc. 5, 65\u201373 (2003).","journal-title":"Tech. Gastrointest. Endosc."},{"key":"20557_CR9","volume-title":"Cummings Otolaryngology-Head and Neck Surgery e-Book","author":"PW Flint","year":"2014","unstructured":"Flint, P. W. et al. Cummings Otolaryngology-Head and Neck Surgery e-Book (Elsevier Health Sciences, 2014)."},{"key":"20557_CR10","first-page":"287","volume":"128","author":"M Sleigh","year":"1983","unstructured":"Sleigh, M. Ciliary function in transport of mucus. Eur. J. Respir. Dis. Suppl. 128, 287\u2013292 (1983).","journal-title":"Eur. J. Respir. Dis. Suppl."},{"key":"20557_CR11","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1164\/ajrccm\/137.3.726","volume":"137","author":"MA Sleigh","year":"1988","unstructured":"Sleigh, M. A., Blake, J. R. & Liron, N. The propulsion of mucus by cilia. Am. Rev. Respir. Dis. 137, 726\u2013741 (1988).","journal-title":"Am. Rev. Respir. Dis."},{"key":"20557_CR12","doi-asserted-by":"publisher","first-page":"4131","DOI":"10.1242\/dev.02595","volume":"133","author":"BW Bisgrove","year":"2006","unstructured":"Bisgrove, B. W. & Yost, H. J. The roles of cilia in developmental disorders and disease. Development 133, 4131\u20134143 (2006).","journal-title":"Development"},{"key":"20557_CR13","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1038\/nrm2278","volume":"8","author":"M Fliegauf","year":"2007","unstructured":"Fliegauf, M., Benzing, T. & Omran, H. When cilia go bad: Cilia defects and ciliopathies. Nat. Rev. Mol. Cell Biol. 8, 880\u2013893 (2007).","journal-title":"Nat. Rev. Mol. Cell Biol."},{"key":"20557_CR14","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.jbiomech.2019.01.015","volume":"85","author":"Y Shang","year":"2019","unstructured":"Shang, Y., Inthavong, K. & Tu, J. Development of a computational fluid dynamics model for mucociliary clearance in the nasal cavity. J. Biomech. 85, 74\u201383 (2019).","journal-title":"J. Biomech."},{"key":"20557_CR15","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.3390\/diagnostics11071301","volume":"11","author":"A Reula","year":"2021","unstructured":"Reula, A. et al. High-speed video microscopy for primary ciliary dyskinesia diagnosis: A study of ciliary motility variations with time and Temperature. Diagnostics 11, 1301 (2021).","journal-title":"Diagnostics"},{"key":"20557_CR16","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1211\/0022357055777","volume":"57","author":"S Dimova","year":"2005","unstructured":"Dimova, S. et al. High-speed digital imaging method for ciliary beat frequency measurement. J. Pharm. Pharmacol. 57, 521\u2013526 (2005).","journal-title":"J. Pharm. Pharmacol."},{"key":"20557_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.tiv.2020.104865","volume":"66","author":"L Tratnjek","year":"2020","unstructured":"Tratnjek, L., Kreft, M., Kristan, K. & Kreft, M. E. Ciliary beat frequency of in vitro human nasal epithelium measured with the simple high-speed microscopy is applicable for safety studies of nasal drug formulations. Toxicol. In Vitro 66, 104865 (2020).","journal-title":"Toxicol. In Vitro"},{"key":"20557_CR18","doi-asserted-by":"publisher","first-page":"2494","DOI":"10.1364\/BOE.7.002494","volume":"7","author":"KK Chu","year":"2016","unstructured":"Chu, K. K. et al. In vivo imaging of airway cilia and mucus clearance with micro-optical coherence tomography. Biomed. Opt. Express 7, 2494\u20132505 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR19","doi-asserted-by":"publisher","first-page":"1978","DOI":"10.1364\/BOE.3.001978","volume":"3","author":"AL Oldenburg","year":"2012","unstructured":"Oldenburg, A. L., Chhetri, R. K., Hill, D. B. & Button, B. Monitoring airway mucus flow and ciliary activity with optical coherence tomography. Biomed. Opt. Express 3, 1978\u20131992 (2012).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR20","doi-asserted-by":"publisher","first-page":"5100","DOI":"10.1364\/BOE.9.005100","volume":"9","author":"S Wagner","year":"2018","unstructured":"Wagner, S., Zrenner, E. & Strasser, T. Ciliary muscle thickness profiles derived from optical coherence tomography images. Biomed. Opt. Express 9, 5100\u20135114 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-017-14670-9","volume":"7","author":"UA Gamm","year":"2017","unstructured":"Gamm, U. A., Huang, B. K., Mis, E. K., Khokha, M. K. & Choma, M. A. Visualization and quantification of injury to the ciliated epithelium using quantitative flow imaging and speckle variance optical coherence tomography. Sci. Rep. 7, 1\u20137 (2017).","journal-title":"Sci. Rep."},{"key":"20557_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-017-08968-x","volume":"7","author":"JC Jing","year":"2017","unstructured":"Jing, J. C., Chen, J. J., Chou, L., Wong, B. J. & Chen, Z. Visualization and detection of ciliary beating pattern and frequency in the upper airway using phase resolved Doppler optical coherence tomography. Sci. Rep. 7, 1\u201311 (2017).","journal-title":"Sci. Rep."},{"key":"20557_CR23","volume-title":"Speckle Phenomena in Optics: Theory and Applications","author":"JW Goodman","year":"2007","unstructured":"Goodman, J. W. Speckle Phenomena in Optics: Theory and Applications (Roberts and Company Publishers, 2007)."},{"key":"20557_CR24","doi-asserted-by":"publisher","DOI":"10.1117\/1.3505008","volume":"15","author":"Y Beiderman","year":"2010","unstructured":"Beiderman, Y. et al. Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern. J. Biomed. Opt. 15, 061707 (2010).","journal-title":"J. Biomed. Opt."},{"key":"20557_CR25","doi-asserted-by":"publisher","first-page":"B45","DOI":"10.1364\/AO.57.000B45","volume":"57","author":"M Golberg","year":"2018","unstructured":"Golberg, M., Ruiz-Rivas, J., Polani, S., Beiderman, Y. & Zalevsky, Z. Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging. Appl. Opt. 57, B45\u2013B51 (2018).","journal-title":"Appl. Opt."},{"key":"20557_CR26","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1364\/BOE.2.000858","volume":"2","author":"Y Beiderman","year":"2011","unstructured":"Beiderman, Y. et al. Demonstration of remote optical measurement configuration that correlates to glucose concentration in blood. Biomed. Opt. Express 2, 858\u2013870 (2011).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR27","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.1364\/BOE.5.001926","volume":"5","author":"N Ozana","year":"2014","unstructured":"Ozana, N. et al. Improved noncontact optical sensor for detection of glucose concentration and indication of dehydration level. Biomed. Opt. Express 5, 1926\u20131940 (2014).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR28","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1364\/BOE.6.000651","volume":"6","author":"Y Bishitz","year":"2015","unstructured":"Bishitz, Y. et al. Noncontact optical sensor for bone fracture diagnostics. Biomed. Opt. Express 6, 651\u2013657 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR29","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1364\/BOE.7.001003","volume":"7","author":"Y Bishitz","year":"2016","unstructured":"Bishitz, Y. et al. Optical configuration of pigmented lesion detection by frequency analysis of skin speckle patterns. Biomed. Opt. Express 7, 1003\u20131014 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"20557_CR30","doi-asserted-by":"publisher","first-page":"16187","DOI":"10.1364\/OE.26.016187","volume":"26","author":"N Ozana","year":"2018","unstructured":"Ozana, N. et al. Remote optical sensing in otolaryngology: Middle ear effusion detection. Opt. Express 26, 16187\u201316199 (2018).","journal-title":"Opt. Express"},{"key":"20557_CR31","doi-asserted-by":"publisher","first-page":"20040","DOI":"10.1364\/OE.387932","volume":"28","author":"D Duadi","year":"2020","unstructured":"Duadi, D. et al. Non-contact optical sensing of vocal fold vibrations by secondary speckle patterns. Opt. Express 28, 20040\u201320050 (2020).","journal-title":"Opt. Express"},{"key":"20557_CR32","volume-title":"Laser Speckle and Related Phenomena 9\u201375","author":"JW Goodman","year":"1975","unstructured":"Goodman, J. W. Laser Speckle and Related Phenomena 9\u201375 (Springer, 1975)."},{"key":"20557_CR33","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1364\/JOSA.66.001145","volume":"66","author":"JW Goodman","year":"1976","unstructured":"Goodman, J. W. Some fundamental properties of speckle. JOSA 66, 1145\u20131150 (1976).","journal-title":"JOSA"},{"key":"20557_CR34","doi-asserted-by":"publisher","first-page":"21566","DOI":"10.1364\/OE.17.021566","volume":"17","author":"Z Zalevsky","year":"2009","unstructured":"Zalevsky, Z. et al. Simultaneous remote extraction of multiple speech sources and heart beats from secondary speckles pattern. Opt. Express 17, 21566\u201321580 (2009).","journal-title":"Opt. Express"},{"key":"20557_CR35","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1088\/0022-3735\/3\/3\/312","volume":"3","author":"J Leendertz","year":"1970","unstructured":"Leendertz, J. Interferometric displacement measurement on scattering surfaces utilizing speckle effect. J. Phys. E: Sci. Instrum. 3, 214 (1970).","journal-title":"J. Phys. E: Sci. Instrum."},{"key":"20557_CR36","first-page":"25","volume":"28","author":"A Halama","year":"1990","unstructured":"Halama, A., Decreton, S., Bijloos, J. & Clement, P. Density of epithelial cells in the normal human nose and the paranasal sinus mucosa. A scanning electron microscopic study. Rhinology 28, 25\u201332 (1990).","journal-title":"Rhinology"},{"key":"20557_CR37","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1109\/JPROC.2014.2385793","volume":"103","author":"N Ozana","year":"2015","unstructured":"Ozana, N. et al. Demonstration of a remote optical measurement configuration that correlates with breathing, heart rate, pulse pressure, blood coagulation, and blood oxygenation. Proc. IEEE 103, 248\u2013262 (2015).","journal-title":"Proc. IEEE"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-20557-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-20557-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-20557-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T11:47:39Z","timestamp":1664970459000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-20557-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,5]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["20557"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-20557-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,5]]},"assertion":[{"value":"6 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16614"}}