{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T18:31:03Z","timestamp":1791311463153,"version":"4.3.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T00:00:00Z","timestamp":1667174400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T00:00:00Z","timestamp":1667174400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The present study examined the effects of auxetic shoes on the biomechanics of the spine, as compared to barefoot and conventional shoe conditions, during gait and drop vertical jump (DVJ) activities using a combined in vivo and musculoskeletal modeling approach. Motion and force-plate data as well as electromyographic (EMG) activities of select trunk muscles of 11 individuals were collected during foregoing activities. In DVJ activity, two main phases of first landing (FL) and second landing (SL) were studied. In the FL phase of DVJ noticeable alternations were observed when auxetic shoes were used. That is, compared to the conventional footwear condition, smaller EMG activities in extensor muscles (by\u2009~\u200916\u201329%, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), smaller anterior\u2013posterior (AP) distance between the center of pressure of ground reaction force and heel (by\u2009~\u200919%, <jats:italic>p<\/jats:italic>\u2009=\u20090.002), generally larger maximal hip, knee, and ankle flexion angles (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.005) and finally smaller maximal L5-S1 compression force and maximal external moment (by\u2009~\u200912 and 8%, respectively, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) were obtained by wearing auxetic shoes. Our results, therefore, indicate that using auxetic shoes can reduce load on the lumbar spine during high-demanding activities such as vertical jump and thus may decrease the musculoskeletal risk of injuries during these activities.<\/jats:p>","DOI":"10.1038\/s41598-022-21540-6","type":"journal-article","created":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T17:04:49Z","timestamp":1667235889000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Effects of auxetic shoe on lumbar spine kinematics and kinetics during gait and drop vertical jump by a combined in vivo and modeling investigation"],"prefix":"10.1038","volume":"12","author":[{"given":"M. Rahmani","family":"Dehaghani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Nourani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Arjmand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,31]]},"reference":[{"key":"21540_CR1","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.gaitpost.2019.02.007","volume":"69","author":"R Michalik","year":"2019","unstructured":"Michalik, R. et al. Comparison of two different designs of forefoot off-loader shoes and their influence on gait and spinal posture. Gait Posture 69, 202\u2013208 (2019).","journal-title":"Gait Posture"},{"key":"21540_CR2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjsem-2016-000170","volume":"2","author":"CS MacRae","year":"2016","unstructured":"MacRae, C. S., Critchley, D., Morrissey, M., Shortland, A. & Lewis, J. S. Do rocker-sole shoes influence postural stability in chronic low back pain? A randomised trial. BMJ Open Sports Exerc. Med. 2, e000170 (2016).","journal-title":"BMJ Open Sports Exerc. Med."},{"key":"21540_CR3","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.gaitpost.2019.01.017","volume":"69","author":"M Khoury-Mireb","year":"2019","unstructured":"Khoury-Mireb, M., Solomonow-Avnon, D., Rozen, N. & Wolf, A. The effect of unstable shoe designs on the variability of gait measures. Gait Posture 69, 60\u201365 (2019).","journal-title":"Gait Posture"},{"key":"21540_CR4","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1016\/j.jbiomech.2013.02.024","volume":"46","author":"NA Bates","year":"2013","unstructured":"Bates, N. A., Ford, K. R., Myer, G. D. & Hewett, T. E. Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment. J. Biomech. 46, 1237\u20131241 (2013).","journal-title":"J. Biomech."},{"key":"21540_CR5","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.humov.2018.03.011","volume":"59","author":"JD Simpson","year":"2018","unstructured":"Simpson, J. D., Miller, B. L., O\u2019Neal, E. K., Chander, H. & Knight, A. C. Ground reaction forces during a drop vertical jump: Impact of external load training. Hum. Mov. Sci. 59, 12\u201319 (2018).","journal-title":"Hum. Mov. Sci."},{"key":"21540_CR6","doi-asserted-by":"crossref","unstructured":"Collin Herb, C., Grossman, K., Feger, M. A., Donovan, L. & Hertel, J. Lower extremity biomechanics during a drop-vertical jump in participants with or without chronic ankle instability. J. Athl. Train. 53, 364\u2013371 (2018).","DOI":"10.4085\/1062-6050-481-15"},{"issue":"Suppl 1","key":"21540_CR7","first-page":"159","volume":"39","author":"M \u010coh","year":"2015","unstructured":"\u010coh, M. et al. Kinematic, dynamic and EMG analysis of drop jumps in female elite triple jump athletes. Coll. Antropol. 39(Suppl 1), 159\u2013166 (2015).","journal-title":"Coll. Antropol."},{"key":"21540_CR8","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.ptsp.2010.10.001","volume":"12","author":"HT Peng","year":"2011","unstructured":"Peng, H. T., Kernozek, T. W. & Song, C. Y. Quadricep and hamstring activation during drop jumps with changes in drop height. Phys. Ther. Sport 12, 127\u2013132 (2011).","journal-title":"Phys. Ther. Sport"},{"key":"21540_CR9","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.jbiomech.2018.01.011","volume":"69","author":"K Koyama","year":"2018","unstructured":"Koyama, K. & Yamauchi, J. Comparison of lower limb kinetics, kinematics and muscle activation during drop jumping under shod and barefoot conditions. J. Biomech. 69, 47\u201353 (2018).","journal-title":"J. Biomech."},{"key":"21540_CR10","doi-asserted-by":"crossref","unstructured":"Fong Yan, A., Hiller, C., Sinclair, P. J. & Smith, R. M. Kinematic analysis of Saut\u00e9s in barefoot and shod conditions. J. Dance Med. Sci. 18, 149\u2013158 (2014).","DOI":"10.12678\/1089-313X.18.4.149"},{"key":"21540_CR11","first-page":"1","volume":"10","author":"R Alonzo","year":"2020","unstructured":"Alonzo, R. et al. Effects of basketball shoe midsole hardness on lower extremity biomechanics and perception during drop jumping from different heights. Appl. Sci. (Switzerland) 10, 1\u201313 (2020).","journal-title":"Appl. Sci. (Switzerland)"},{"key":"21540_CR12","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1016\/j.clinbiomech.2009.08.003","volume":"24","author":"KA Boyer","year":"2009","unstructured":"Boyer, K. A. & Andriacchi, T. P. Changes in running kinematics and kinetics in response to a rockered shoe intervention. Clin. Biomech. 24, 872\u2013876 (2009).","journal-title":"Clin. Biomech."},{"key":"21540_CR13","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.jelekin.2016.10.005","volume":"31","author":"DJ Southwell","year":"2016","unstructured":"Southwell, D. J., Petersen, S. A., Beach, T. A. C. & Graham, R. B. The effects of squatting footwear on three-dimensional lower limb and spine kinetics. J. Electromyogr. Kinesiol. 31, 111\u2013118 (2016).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"21540_CR14","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.proeng.2014.06.079","volume":"72","author":"M Sanami","year":"2014","unstructured":"Sanami, M., Ravirala, N., Alderson, K. & Alderson, A. Auxetic materials for sports applications. Procedia Eng. 72, 453\u2013458 (2014).","journal-title":"Procedia Eng."},{"key":"21540_CR15","doi-asserted-by":"crossref","unstructured":"Moroney, C., Alderson, A., Allen, T., Sanami, M. & Venkatraman, P. The application of auxetic material for protective sports apparel. Proceedings 2, 251 (2018).","DOI":"10.3390\/proceedings2060251"},{"key":"21540_CR16","unstructured":"M. Cross, T., W. Hoffer, K., P. Jones, D., B. Kirschner, E. & C. Meschter, J. Auxetic structures and footwear with soles having auxetic structures. vol. 2 402\u2013439 (2016)."},{"key":"21540_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.110043","volume":"112","author":"F Asadi","year":"2020","unstructured":"Asadi, F. & Arjmand, N. Marker-less versus marker-based driven musculoskeletal models of the spine during static load-handling activities. J. Biomech. 112, 110043 (2020).","journal-title":"J. Biomech."},{"key":"21540_CR18","unstructured":"Haddad, O. Development and validation of a fatigue-modified, EMG-assisted biomechanical model of the lumbar region. (2011)."},{"key":"21540_CR19","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.ergon.2013.08.004","volume":"43","author":"O Haddad","year":"2013","unstructured":"Haddad, O. & Mirka, G. A. Trunk muscle fatigue and its implications in EMG-assisted biomechanical modeling. Int. J. Ind. Ergon. 43, 425\u2013429 (2013).","journal-title":"Int. J. Ind. Ergon."},{"key":"21540_CR20","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1152\/jn.00549.2010","volume":"106","author":"SA Chvatal","year":"2011","unstructured":"Chvatal, S. A., Torres-Oviedo, G., Safavynia, S. A. & Ting, L. H. Common muscle synergies for control of center of mass and force in nonstepping and stepping postural behaviors. J. Neurophysiol. 106, 999\u20131015 (2011).","journal-title":"J. Neurophysiol."},{"key":"21540_CR21","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.ergon.2010.02.006","volume":"40","author":"C Trask","year":"2010","unstructured":"Trask, C. et al. EMG estimated mean, peak, and cumulative spinal compression of workers in five heavy industries. Int. J. Ind. Ergon. 40, 448\u2013454 (2010).","journal-title":"Int. J. Ind. Ergon."},{"key":"21540_CR22","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.jelekin.2018.04.007","volume":"41","author":"T Alenabi","year":"2018","unstructured":"Alenabi, T., Whittaker, R., Kim, S. Y. & Dickerson, C. R. Maximal voluntary isometric contraction tests for normalizing electromyographic data from different regions of supraspinatus and infraspinatus muscles: Identifying reliable combinations. J. Electromyogr. Kinesiol. 41, 19\u201326 (2018).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"21540_CR23","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1016\/j.clinbiomech.2007.10.012","volume":"23","author":"M Abdoli-E","year":"2008","unstructured":"Abdoli-E, M. & Stevenson, J. M. The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting. Clin. Biomech. 23, 372\u2013380 (2008).","journal-title":"Clin. Biomech."},{"key":"21540_CR24","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1016\/j.jbiomech.2016.02.046","volume":"49","author":"ME Raabe","year":"2016","unstructured":"Raabe, M. E. & Chaudhari, A. M. W. An investigation of jogging biomechanics using the full-body lumbar spine model: Model development and validation. J. Biomech. 49, 1238\u20131243 (2016).","journal-title":"J. Biomech."},{"key":"21540_CR25","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","volume":"54","author":"SL Delp","year":"2007","unstructured":"Delp, S. L. et al. OpenSim: Open-source software to create and analyze dynamic simulations of movement. IEEE Trans. Biomed. Eng. 54, 1940\u20131950 (2007).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"21540_CR26","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.gaitpost.2011.11.023","volume":"35","author":"KM Steele","year":"2011","unstructured":"Steele, K. M., DeMers, M. S., Schwartz, M. H. & Delp, S. L. Compressive tibiofemoral force during crouch gait. Gait Posture 35, 556\u2013560 (2011).","journal-title":"Gait Posture"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21540-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21540-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21540-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T17:16:48Z","timestamp":1667236608000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21540-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,31]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["21540"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-21540-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,31]]},"assertion":[{"value":"26 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18326"}}