{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T22:46:53Z","timestamp":1793832413059,"version":"4.6.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,27]],"date-time":"2022-10-27T00:00:00Z","timestamp":1666828800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,27]],"date-time":"2022-10-27T00:00:00Z","timestamp":1666828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"E.M.S. Electro Medical Systems S.A., Nyon, Switzerland"},{"DOI":"10.13039\/501100007210","name":"RWTH Aachen University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100007210","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Ballistic devices that generate radial pressure waves are used for the treatment of different therapeutic indications. In order to assess the effectiveness of these devices and to interpret and transfer the results of clinical trials, it is important to know their acoustic output. In this paper, two ballistic devices and their reproducibility at different clinically relevant settings were investigated in the same in-vitro test setup. Pressure curves were measured in water at different intensity levels and pulse repetition rates. The sound field parameters (peak pressures, positive pulse intensity integral) were calculated from the pressure curves. Additionally, the surface velocity of the applicator was determined in air using a vibrometer. Both devices show a good pulse-to-pulse reproducibility. While the peak maximum pressure and the positive pulse intensity integral decrease only slightly (p<jats:sub>max<\/jats:sub> up to 12%, PII<jats:sup>+<\/jats:sup> up to 18.8%) comparing 1\u00a0Hz and 25\u00a0Hz for one device, they drop sharply (p<jats:sub>max<\/jats:sub> up to 68.4%, PII<jats:sup>+<\/jats:sup> up to 90.2%) for the other device comparing 1\u00a0Hz to 21\u00a0Hz. The same effect was observed in the vibrometer measurements. The results show that with increasing pulse repetition rate the stability of the parameters varies between different devices. Hence, all sound field parameters should be compared before transferring settings from one device to another.<\/jats:p>","DOI":"10.1038\/s41598-022-21595-5","type":"journal-article","created":{"date-parts":[[2022,10,27]],"date-time":"2022-10-27T12:03:32Z","timestamp":1666872212000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Influence of the pulse repetition rate on the acoustic output of ballistic pressure wave devices"],"prefix":"10.1038","volume":"12","author":[{"given":"Nina","family":"Reinhardt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Wegenaer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mat\u00edas","family":"de la Fuente","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,27]]},"reference":[{"key":"21595_CR1","unstructured":"Deutschsprachige Internationale Gesellschaft f\u00fcr Extrakorporale Sto\u00dfwellentherapie. DIGEST Guidelines for Extracorporeal Shock Wave Therapy. https:\/\/www.shockwavetherapy.org\/fileadmin\/user_upload\/ISMST_Guidelines.pdf (2019)."},{"key":"21595_CR2","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1063\/1.2205513","volume":"829","author":"PV Chitnis","year":"2006","unstructured":"Chitnis, P. V. Acoustic and cavitation fields of shock wave therapy devices. AIP Conf. Proc. 829, 440\u2013444. https:\/\/doi.org\/10.1063\/1.2205513 (2006).","journal-title":"AIP Conf. Proc."},{"key":"21595_CR3","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1016\/j.ultrasmedbio.2007.02.014","volume":"33","author":"RO Cleveland","year":"2007","unstructured":"Cleveland, R. O., Chitnis, P. V. & McClure, S. R. Acoustic field of a ballistic shock wave therapy device. Ultrasound Med. Biol. 33, 1327\u20131335. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2007.02.014 (2007).","journal-title":"Ultrasound Med. Biol."},{"key":"21595_CR4","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0140541","volume":"10","author":"NBM Cs\u00e1sz\u00e1r","year":"2015","unstructured":"Cs\u00e1sz\u00e1r, N. B. M. et al. Radial shock wave devices generate cavitation. PLoS\u00a0One 10, e0140541. https:\/\/doi.org\/10.1371\/journal.pone.0140541 (2015).","journal-title":"PLoS\u00a0One"},{"key":"21595_CR5","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1515\/cdbme-2015-0007","volume":"1","author":"A Jamshidi Rad","year":"2015","unstructured":"Jamshidi Rad, A. & Ueberle, F. Field mapping of ballistic pressure pulse sources. Curr. Dir. Biomed. Eng. 1, 26\u201329. https:\/\/doi.org\/10.1515\/cdbme-2015-0007 (2015).","journal-title":"Curr. Dir. Biomed. Eng."},{"key":"21595_CR6","doi-asserted-by":"publisher","DOI":"10.1515\/bmt-2012-4439","author":"F Ueberle","year":"2012","unstructured":"Ueberle, F. & Jamshidi Rad, A. Ballistic pain therapy devices: Measurement of pressure pulse parameters. Biomed. Eng. https:\/\/doi.org\/10.1515\/bmt-2012-4439 (2012).","journal-title":"Biomed. Eng."},{"key":"21595_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2020.3016071","volume":"70","author":"G Cosoli","year":"2021","unstructured":"Cosoli, G., Verdenelli, L. & Scalise, L. Metrological characterization of therapeutic devices for pressure wave therapy: Force, energy density, and waveform evaluation. IEEE Trans. Instrum. Meas. 70, 1\u20138. https:\/\/doi.org\/10.1109\/TIM.2020.3016071 (2021).","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"21595_CR8","doi-asserted-by":"publisher","DOI":"10.1515\/bmt-2013-4130","author":"F Ueberle","year":"2013","unstructured":"Ueberle, F. & Rad, A. J. Characterization of unfocused\/weakly focused pressure pulse sources for extracorporeal pain therapy (\u201cradial shock wave therapy\u201d sources). Biomed. Tech. https:\/\/doi.org\/10.1515\/bmt-2013-4130 (2013).","journal-title":"Biomed. Tech."},{"key":"21595_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultras.2020.106238","volume":"110","author":"MJ Choi","year":"2021","unstructured":"Choi, M. J. & Kwon, O. Temporal and spectral characteristics of the impulsive waves produced by a clinical ballistic shock wave therapy device. Ultrasonics 110, 106238. https:\/\/doi.org\/10.1016\/j.ultras.2020.106238 (2021).","journal-title":"Ultrasonics"},{"key":"21595_CR10","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1515\/cdbme-2021-2100","volume":"7","author":"N Reinhardt","year":"2021","unstructured":"Reinhardt, N., Dick, T., Lang, L., Radermacher, K. & La Fuente, M. D. Hybrid test bench for high repetition rate radial shock wave measurement. Curr. Dir. Biomed. Eng. 7, 395\u2013398. https:\/\/doi.org\/10.1515\/cdbme-2021-2100 (2021).","journal-title":"Curr. Dir. Biomed. Eng."},{"key":"21595_CR11","doi-asserted-by":"publisher","first-page":"135","DOI":"10.12693\/APhysPolA.127.135","volume":"127","author":"F Ueberle","year":"2015","unstructured":"Ueberle, F. & Jamshidi-Rad, A. Unfocused\/weakly focused pressure pulse sources for pain therapy: Measurements in water and in a dry test bench. Acta Phys. Pol. A 127, 135\u2013137. https:\/\/doi.org\/10.12693\/APhysPolA.127.135 (2015).","journal-title":"Acta Phys. Pol. A"},{"key":"21595_CR12","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1121\/1.2127115","volume":"6","author":"YA Pishchalnikov","year":"2005","unstructured":"Pishchalnikov, Y. A. et al. Cavitation selectively reduces the negative-pressure phase of lithotripter shock pulses. Acoust. Res. Lett. ARLO 6, 280\u2013286. https:\/\/doi.org\/10.1121\/1.2127115 (2005).","journal-title":"Acoust. Res. Lett. ARLO"},{"key":"21595_CR13","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1515\/cdbme-2018-0047","volume":"4","author":"N Reinhardt","year":"2018","unstructured":"Reinhardt, N. et al. Experimental setup for evaluation of cavitation effects in ESWL. Curr. Dir. Biomed. Eng. 4, 191\u2013194. https:\/\/doi.org\/10.1515\/cdbme-2018-0047 (2018).","journal-title":"Curr. Dir. Biomed. Eng."},{"key":"21595_CR14","doi-asserted-by":"publisher","first-page":"3113","DOI":"10.1088\/0031-9155\/43\/10\/029","volume":"43","author":"P Huber","year":"1998","unstructured":"Huber, P., J\u00f6chle, K. & Debus, J. Influence of shock wave pressure amplitude and pulse repetition frequency on the lifespan, size and number of transient cavities in the field of an electromagnetic lithotripter. Phys. Med. Biol. 43, 3113\u20133128. https:\/\/doi.org\/10.1088\/0031-9155\/43\/10\/029 (1998).","journal-title":"Phys. Med. Biol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21595-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21595-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21595-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,27]],"date-time":"2022-10-27T12:23:48Z","timestamp":1666873428000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-21595-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,27]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["21595"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-21595-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,27]]},"assertion":[{"value":"27 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18060"}}