{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T09:59:19Z","timestamp":1794218359127,"version":"4.8.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,15]],"date-time":"2022-11-15T00:00:00Z","timestamp":1668470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,15]],"date-time":"2022-11-15T00:00:00Z","timestamp":1668470400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To compare the visual outcomes and subjective experience of three intraocular lenses (IOL) implant strategies. Retrospective comparative study. This study comprised patients who underwent phacoemulsification and bilateral implantation of extended depth of focus (EDOF) IOL (ZXR00; EDOF group), blended implantation of EDOF and bifocal IOL (ZXR00\/ZLB00; blended group), and bilateral implantation of trifocal IOL (AT LISA tri 839MP; trifocal group). The outcomes included visual acuity (VA), visual\u00a0defocus curve, contrast sensitivity, visual quality, quality of life, spectacle independence, and patient satisfaction. Follow-up was performed 3\u00a0months after the surgery. This study included 114 eyes of 57 patients (20 in EDOF group; 16 in blended group; 21 in trifocal group). Patients in the three groups had high quality of life, patient satisfaction, and good contrast sensitivity. The EDOF group had the worst near VA, but the visual quality was the best. The blended group had good VA and slight photic disturbance. The trifocal group obtained the best whole range of VA, but the photic disturbance was significantly severe than the EDOF group. Both the blended and trifocal groups achieved high spectacle independence, but some patients in the EDOF group need spectacle when dealing with close-range tasks.<\/jats:p>","DOI":"10.1038\/s41598-022-23694-9","type":"journal-article","created":{"date-parts":[[2022,11,15]],"date-time":"2022-11-15T20:20:22Z","timestamp":1668543622000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Visual outcomes and subjective experience with three intraocular lenses based presbyopia correcting strategies in cataract patients"],"prefix":"10.1038","volume":"12","author":[{"given":"Meiyi","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangbin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,15]]},"reference":[{"key":"23694_CR1","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1016\/j.jcrs.2006.02.006","volume":"32","author":"JA Davison","year":"2006","unstructured":"Davison, J. A. & Simpson, M. J. History and development of the apodized diffractive intraocular lens. J. Cataract Refract. Surg. 32, 849\u2013858. https:\/\/doi.org\/10.1016\/j.jcrs.2006.02.006 (2006).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR2","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/s0886-3350(00)00540-x","volume":"27","author":"G H\u00e4ring","year":"2001","unstructured":"H\u00e4ring, G., Dick, H. B., Krummenauer, F., Weissmantel, U. & Kr\u00f6ncke, W. Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. Results of a multicenter questionnaire. J. Cataract Refract. Surg. 27, 245\u2013249. https:\/\/doi.org\/10.1016\/s0886-3350(00)00540-x (2001).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR3","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","volume":"37","author":"NE de Vries","year":"2011","unstructured":"de Vries, N. E. et al. Dissatisfaction after implantation of multifocal intraocular lenses. J. Cataract Refract. Surg. 37, 859\u2013865. https:\/\/doi.org\/10.1016\/j.jcrs.2010.11.032 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR4","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1097\/apo.0000000000000296","volume":"9","author":"P Kanclerz","year":"2020","unstructured":"Kanclerz, P., Toto, F., Grzybowski, A. & Alio, J. L. Extended depth-of-field intraocular lenses: An update. Asia-Pac. J. Ophthalmol. (Philadelphia, Pa.) 9, 194\u2013202. https:\/\/doi.org\/10.1097\/apo.0000000000000296 (2020).","journal-title":"Asia-Pac. J. Ophthalmol. (Philadelphia, Pa.)"},{"key":"23694_CR5","doi-asserted-by":"publisher","first-page":"236","DOI":"10.3928\/1081597x-20180206-04","volume":"34","author":"YS Yoo","year":"2018","unstructured":"Yoo, Y. S. et al. Through-focus optical bench performance of extended depth-of-focus and bifocal intraocular lenses compared to a monofocal lens. J. Refract. Surg. (Thorofare, N.J.: 1995) 34, 236\u2013243. https:\/\/doi.org\/10.3928\/1081597x-20180206-04 (2018).","journal-title":"J. Refract. Surg. (Thorofare, N.J.: 1995)"},{"key":"23694_CR6","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1016\/j.jcrs.2019.07.014","volume":"45","author":"M B\u00f6hm","year":"2019","unstructured":"B\u00f6hm, M., Petermann, K., Hemkeppler, E. & Kohnen, T. Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus. J. Cataract Refract. Surg. 45, 1625\u20131636. https:\/\/doi.org\/10.1016\/j.jcrs.2019.07.014 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR7","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1007\/s10792-019-01196-4","volume":"40","author":"MA Gil","year":"2020","unstructured":"Gil, M. A., Var\u00f3n, C., Cardona, G. & Buil, J. A. Visual acuity and defocus curves with six multifocal intraocular lenses. Int. Ophthalmol. 40, 393\u2013401. https:\/\/doi.org\/10.1007\/s10792-019-01196-4 (2020).","journal-title":"Int. Ophthalmol."},{"key":"23694_CR8","doi-asserted-by":"publisher","first-page":"7321794","DOI":"10.1155\/2018\/7321794","volume":"2018","author":"S Ganesh","year":"2018","unstructured":"Ganesh, S., Brar, S., Pawar, A. & Relekar, K. J. Visual and refractive outcomes following bilateral implantation of extended range of vision intraocular lens with micromonovision. J. Ophthalmol. 2018, 7321794. https:\/\/doi.org\/10.1155\/2018\/7321794 (2018).","journal-title":"J. Ophthalmol."},{"key":"23694_CR9","doi-asserted-by":"publisher","first-page":"8881794","DOI":"10.1155\/2021\/8881794","volume":"2021","author":"JH Lee","year":"2021","unstructured":"Lee, J. H. et al. Clinical outcomes after mix-and-match implantation of extended depth of focus and diffractive multifocal intraocular lenses. J. Ophthalmol. 2021, 8881794. https:\/\/doi.org\/10.1155\/2021\/8881794 (2021).","journal-title":"J. Ophthalmol."},{"key":"23694_CR10","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.2147\/opth.S145945","volume":"11","author":"AL de Medeiros","year":"2017","unstructured":"de Medeiros, A. L. et al. Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens. Clin. Ophthalmol. (Auckland, N.Z.) 11, 1911\u20131916. https:\/\/doi.org\/10.2147\/opth.S145945 (2017).","journal-title":"Clin. Ophthalmol. (Auckland, N.Z.)"},{"key":"23694_CR11","doi-asserted-by":"publisher","first-page":"528","DOI":"10.3928\/1081597x-20200616-01","volume":"36","author":"JE Song","year":"2020","unstructured":"Song, J. E., Khoramnia, R., Son, H. S., Knorz, M. C. & Choi, C. Y. Comparison between bilateral implantation of a trifocal IOL and mix-and-match implantation of a bifocal IOL and an extended depth of focus IOL. J. Refract. Surg. (Thorofare, N.J.: 1995) 36, 528\u2013535. https:\/\/doi.org\/10.3928\/1081597x-20200616-01 (2020).","journal-title":"J. Refract. Surg. (Thorofare, N.J.: 1995)"},{"key":"23694_CR12","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.ajo.2015.09.030","volume":"161","author":"T Kohnen","year":"2016","unstructured":"Kohnen, T., Titke, C. & B\u00f6hm, M. Trifocal intraocular lens implantation to treat visual demands in various distances following lens removal. Am. J. Ophthalmol. 161, 71-77.e71. https:\/\/doi.org\/10.1016\/j.ajo.2015.09.030 (2016).","journal-title":"Am. J. Ophthalmol."},{"key":"23694_CR13","doi-asserted-by":"publisher","first-page":"295","DOI":"10.3928\/1081597x-20150423-02","volume":"31","author":"FT Kretz","year":"2015","unstructured":"Kretz, F. T., Koss, M. J. & Auffarth, G. U. Intermediate and near visual acuity of an aspheric, bifocal, diffractive multifocal intraocular lens with\u2009+\u20093.25 D near addition. J. Refract. Surg. (Thorofare, N.J.: 1995) 31, 295\u2013299. https:\/\/doi.org\/10.3928\/1081597x-20150423-02 (2015).","journal-title":"J. Refract. Surg. (Thorofare, N.J.: 1995)"},{"key":"23694_CR14","doi-asserted-by":"publisher","first-page":"194","DOI":"10.21037\/atm-22-107","volume":"10","author":"Z Bai","year":"2022","unstructured":"Bai, Z. et al. Visual function assessment of posterior-chamber phakic implantable collamer lenses with a central port. Ann. Transl. Med. 10, 194. https:\/\/doi.org\/10.21037\/atm-22-107 (2022).","journal-title":"Ann. Transl. Med."},{"key":"23694_CR15","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.1055\/s-0033-1351030","volume":"230","author":"H Wilhelm","year":"2013","unstructured":"Wilhelm, H. et al. Assessment of mesopic and contrast vision for driving licences: Which cut-off values, which methods are appropriate?. Klin. Monatsbl. Augenheilkd. 230, 1106\u20131113. https:\/\/doi.org\/10.1055\/s-0033-1351030 (2013).","journal-title":"Klin. Monatsbl. Augenheilkd."},{"key":"23694_CR16","doi-asserted-by":"publisher","first-page":"4413","DOI":"10.1167\/iovs.14-14017","volume":"55","author":"J Khadka","year":"2014","unstructured":"Khadka, J. et al. Translation, cultural adaptation, and Rasch analysis of the visual function (VF-14) questionnaire. Invest. Ophthalmol. Vis. Sci. 55, 4413\u20134420. https:\/\/doi.org\/10.1167\/iovs.14-14017 (2014).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"23694_CR17","doi-asserted-by":"publisher","first-page":"2553","DOI":"10.1007\/s10792-020-01435-z","volume":"40","author":"W Lubi\u0144ski","year":"2020","unstructured":"Lubi\u0144ski, W., Podbor\u0105czy\u0144ska-Jodko, K., Kirkiewicz, M., Mularczyk, M. & Post, M. Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses. Int. Ophthalmol. 40, 2553\u20132562. https:\/\/doi.org\/10.1007\/s10792-020-01435-z (2020).","journal-title":"Int. Ophthalmol."},{"key":"23694_CR18","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/j.jcrs.2018.12.005","volume":"45","author":"A Mart\u00ednez de Carneros-Llorente","year":"2019","unstructured":"Mart\u00ednez de Carneros-Llorente, A., Mart\u00ednez de Carneros, A., Mart\u00ednez de Carneros-Llorente, P. & Jim\u00e9nez-Alfaro, I. Comparison of visual quality and subjective outcomes among 3 trifocal intraocular lenses and 1 bifocal intraocular lens. J. Cataract Refract. Surg. 45, 587\u2013594. https:\/\/doi.org\/10.1016\/j.jcrs.2018.12.005 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR19","doi-asserted-by":"publisher","first-page":"257","DOI":"10.3928\/1081597x-20080301-07","volume":"24","author":"A Mart\u00ednez Palmer","year":"2008","unstructured":"Mart\u00ednez Palmer, A. et al. Visual function with bilateral implantation of monofocal and multifocal intraocular lenses: A prospective, randomized, controlled clinical trial. J. Refract. Surg. (Thorofare, N.J.: 1995) 24, 257\u2013264. https:\/\/doi.org\/10.3928\/1081597x-20080301-07 (2008).","journal-title":"J. Refract. Surg. (Thorofare, N.J.: 1995)"},{"key":"23694_CR20","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.jcrs.2016.06.033","volume":"42","author":"B Cochener","year":"2016","unstructured":"Cochener, B. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J. Cataract Refract. Surg. 42, 1268\u20131275. https:\/\/doi.org\/10.1016\/j.jcrs.2016.06.033 (2016).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR21","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.jcrs.2009.02.018","volume":"35","author":"RJ Cionni","year":"2009","unstructured":"Cionni, R. J., Osher, R. H., Snyder, M. E. & Nordlund, M. L. Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intraocular lenses after cataract extraction: Prospective 6-month study. J. Cataract Refract. Surg. 35, 1033\u20131039. https:\/\/doi.org\/10.1016\/j.jcrs.2009.02.018 (2009).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR22","doi-asserted-by":"publisher","first-page":"2105","DOI":"10.2147\/opth.S66760","volume":"8","author":"D Carson","year":"2014","unstructured":"Carson, D., Hill, W. E., Hong, X. & Karakelle, M. Optical bench performance of AcrySof(\u00ae) IQ ReSTOR(\u00ae), AT LISA(\u00ae) tri, and FineVision(\u00ae) intraocular lenses. Clin. Ophthalmol. (Auckland, N.Z.) 8, 2105\u20132113. https:\/\/doi.org\/10.2147\/opth.S66760 (2014).","journal-title":"Clin. Ophthalmol. (Auckland, N.Z.)"},{"key":"23694_CR23","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1016\/j.jcrs.2016.02.009","volume":"42","author":"RM Nuijts","year":"2016","unstructured":"Nuijts, R. M. et al. Bilateral implantation of\u2009+\u20092.5 D multifocal intraocular lens and contralateral implantation of\u2009+\u20092.5 D and\u2009+\u20093.0 D multifocal intraocular lenses: Clinical outcomes. J. Cataract Refract. Surg. 42, 194\u2013202. https:\/\/doi.org\/10.1016\/j.jcrs.2016.02.009 (2016).","journal-title":"J. Cataract Refract. Surg."},{"key":"23694_CR24","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/j.jcrs.0000000000000780","volume":"48","author":"C Lwowski","year":"2022","unstructured":"Lwowski, C. et al. Visual and patient-reported factors leading to satisfaction after implantation of diffractive extended depth-of-focus and trifocal intraocular lenses. J. Cataract Refract. Surg. 48, 421\u2013428. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000780 (2022).","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-23694-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-23694-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-23694-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,15]],"date-time":"2022-11-15T20:27:01Z","timestamp":1668544021000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-23694-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,15]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["23694"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-23694-9","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,15]]},"assertion":[{"value":"29 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19625"}}