{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T22:57:18Z","timestamp":1771455438986,"version":"3.50.1"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T00:00:00Z","timestamp":1671235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T00:00:00Z","timestamp":1671235200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Quantitative MR imaging is becoming more feasible to be used in clinical work since new approaches have been proposed in order to substantially accelerate the acquisition and due to the possibility of synthetically deriving weighted images from the parametric maps. However, their applicability has to be thoroughly validated in order to be included in clinical practice. In this pilot study, we acquired Magnetic Resonance Image Compilation scans to obtain T1, T2 and PD maps in 14 glioma patients. Abnormal tissue was segmented based on conventional images and using a deep learning segmentation technique to define regions of interest (ROIs). The quantitative T1, T2 and PD values inside ROIs were analyzed using the mean, the standard deviation, the skewness and the kurtosis and compared to the quantitative T1, T2 and PD values found in normal white matter. We found significant differences in pre-contrast T1 and T2 values between abnormal tissue and healthy tissue, as well as between T1w-enhancing and non-enhancing regions. ROC analysis was used to evaluate the potential of quantitative T1 and T2 values for voxel-wise classification of abnormal\/normal tissue (AUC\u2009=\u20090.95) and of T1w enhancement\/non-enhancement (AUC\u2009=\u20090.85). A cross-validated ROC analysis found high sensitivity (73%) and specificity (73%) with AUCs up to 0.68 on the a priori distinction between abnormal tissue with and without T1w-enhancement. These results suggest that normal tissue, abnormal tissue, and tissue with T1w-enhancement are distinguishable by their pre-contrast quantitative values but further investigation is needed.<\/jats:p>","DOI":"10.1038\/s41598-022-24276-5","type":"journal-article","created":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T11:03:49Z","timestamp":1671275029000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Pre-contrast MAGiC in treated gliomas: a pilot study of quantitative MRI"],"prefix":"10.1038","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9025-3631","authenticated-orcid":false,"given":"Laura","family":"Nunez-Gonzalez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9610-4397","authenticated-orcid":false,"given":"Karin A.","family":"van Garderen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5563-2871","authenticated-orcid":false,"given":"Marion","family":"Smits","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1904-4914","authenticated-orcid":false,"given":"Jaap","family":"Jaspers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alejandra M\u00e9ndez","family":"Romero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0656-2963","authenticated-orcid":false,"given":"Dirk H. J.","family":"Poot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan A.","family":"Hernandez-Tamames","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,12,17]]},"reference":[{"key":"24276_CR1","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1586\/14737175.5.6.S3","volume":"5","author":"KI Olsen","year":"2005","unstructured":"Olsen, K. I., Schroeder, P., Corby, R., Vucic, I. & Bardo, D. M. Advanced magnetic resonance imaging techniques to evaluate CNS glioma. Expert Rev. Neurother. 5, 3\u201311 (2005).","journal-title":"Expert Rev. Neurother."},{"key":"24276_CR2","first-page":"1","volume":"2013","author":"H-W Kao","year":"2013","unstructured":"Kao, H.-W., Chiang, S.-W., Chung, H.-W., Tsai, F. Y. & Chen, C.-Y. Advanced MR Imaging of Gliomas: An update. Biomed. Res. Int. 2013, 1\u201314 (2013).","journal-title":"Biomed. Res. Int."},{"key":"24276_CR3","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1007\/s11060-015-1908-9","volume":"125","author":"SJ Fouke","year":"2015","unstructured":"Fouke, S. J. et al. The role of imaging in the management of adults with diffuse low grade glioma: A systematic review and evidence-based clinical practice guideline. J. Neurooncol. 125, 457\u2013479 (2015).","journal-title":"J. Neurooncol."},{"key":"24276_CR4","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s10334-021-00911-6","volume":"35","author":"EAH Warnert","year":"2022","unstructured":"Warnert, E. A. H. et al. Mapping tumour heterogeneity with pulsed 3D CEST MRI in non-enhancing glioma at 3 T. Magn. Reson. Mater. Phy. 35, 53\u201362 (2022).","journal-title":"Magn. Reson. Mater. Phy."},{"key":"24276_CR5","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1093\/neuonc\/noaa141","volume":"22","author":"JL Boxerman","year":"2020","unstructured":"Boxerman, J. L. et al. Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas. Neuro. Oncol. 22, 1262\u20131275 (2020).","journal-title":"Neuro. Oncol."},{"key":"24276_CR6","doi-asserted-by":"publisher","DOI":"10.1093\/neuonc\/nov095","author":"BM Ellingson","year":"2015","unstructured":"Ellingson, B. M. et al. Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials. Neuro-Oncol https:\/\/doi.org\/10.1093\/neuonc\/nov095 (2015).","journal-title":"Neuro-Oncol"},{"key":"24276_CR7","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1038\/s41571-020-00447-z","volume":"18","author":"M Weller","year":"2021","unstructured":"Weller, M. et al. EANO guidelines on the diagnosis and treatment of diffuse gliomas of adulthood. Nat. Rev. Clin. Oncol. 18, 170\u2013186 (2021).","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"24276_CR8","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/RMR.0b013e31821e56d8","volume":"21","author":"SCL Deoni","year":"2010","unstructured":"Deoni, S. C. L. Quantitative relaxometry of the brain. Top. Magn. Reson. Imaging 21, 101\u2013113 (2010).","journal-title":"Top. Magn. Reson. Imaging"},{"key":"24276_CR9","doi-asserted-by":"crossref","unstructured":"G\u00f3mez, P. A. et al. Rapid three-dimensional multiparametric MRI with quantitative transient-state imaging. arXiv:2001.07173 [physics] (2020).","DOI":"10.1038\/s41598-020-70789-2"},{"key":"24276_CR10","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1002\/mrm.21635","volume":"60","author":"JBM Warntjes","year":"2008","unstructured":"Warntjes, J. B. M., Leinhard, O. D., West, J. & Lundberg, P. Rapid magnetic resonance quantification on the brain: Optimization for clinical usage. Magn. Reson. Med. 60, 320\u2013329 (2008).","journal-title":"Magn. Reson. Med."},{"key":"24276_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/BF00173524","author":"S Newman","year":"1993","unstructured":"Newman, S. et al. T1, T2 and proton density measurements in the grading of cerebral gliomas. Eur. Radiol. https:\/\/doi.org\/10.1007\/BF00173524 (1993).","journal-title":"Eur. Radiol."},{"key":"24276_CR12","doi-asserted-by":"publisher","first-page":"53542","DOI":"10.18632\/oncotarget.18612","volume":"8","author":"E Hattingen","year":"2017","unstructured":"Hattingen, E. et al. Value of quantitative magnetic resonance imaging T1-relaxometry in predicting contrast-enhancement in glioblastoma patients. Oncotarget 8, 53542\u201353551 (2017).","journal-title":"Oncotarget"},{"key":"24276_CR13","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1097\/RLI.0000000000000583","volume":"54","author":"J Kleesiek","year":"2019","unstructured":"Kleesiek, J. et al. Can virtual contrast enhancement in brain MRI replace gadolinium?: A feasibility study. Invest. Radiol. 54, 653\u2013660 (2019).","journal-title":"Invest. Radiol."},{"key":"24276_CR14","doi-asserted-by":"publisher","first-page":"2205","DOI":"10.1007\/s00415-017-8609-6","volume":"264","author":"C Laule","year":"2017","unstructured":"Laule, C. et al. Characterization of brain tumours with spin\u2013spin relaxation: pilot case study reveals unique T 2 distribution profiles of glioblastoma, oligodendroglioma and meningioma. J. Neurol. 264, 2205\u20132214 (2017).","journal-title":"J. Neurol."},{"key":"24276_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-021-02703-0","author":"CM Pirkl","year":"2021","unstructured":"Pirkl, C. M. et al. Accelerated 3D whole-brain T1, T2, and proton density mapping: feasibility for clinical glioma MR imaging. Neuroradiology https:\/\/doi.org\/10.1007\/s00234-021-02703-0 (2021).","journal-title":"Neuroradiology"},{"key":"24276_CR16","unstructured":"Tofts, P. S. Methods for quantitative relaxation parameter mapping measuring T1 and T2. In: Proc int soc magn reson med. 1\u20136 (2009)."},{"key":"24276_CR17","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1148\/radiology.171.1.2928538","volume":"171","author":"RK Breger","year":"1989","unstructured":"Breger, R. K., Rimm, A. A., Fischer, M. E., Papke, R. A. & Haughton, V. M. T1 and T2 measurements on a 1.5-T commercial MR imager. Radiology 171, 273\u2013276 (1989).","journal-title":"Radiology"},{"key":"24276_CR18","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.mri.2016.08.021","volume":"35","author":"JZ Bojorquez","year":"2017","unstructured":"Bojorquez, J. Z. et al. What are normal relaxation times of tissues at 3 T?. Magn. Reson. Imaging 35, 69\u201380 (2017).","journal-title":"Magn. Reson. Imaging"},{"key":"24276_CR19","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1038\/nature11971","volume":"495","author":"D Ma","year":"2013","unstructured":"Ma, D. et al. Magnetic resonance fingerprinting. Nature 495, 187\u2013192 (2013).","journal-title":"Nature"},{"key":"24276_CR20","doi-asserted-by":"publisher","first-page":"492","DOI":"10.3174\/ajnr.A5035","volume":"38","author":"C Badve","year":"2017","unstructured":"Badve, C. et al. MR fingerprinting of adult brain tumors: Initial experience. Am. J. Neuroradiol. 38, 492\u2013499 (2017).","journal-title":"Am. J. Neuroradiol."},{"key":"24276_CR21","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3174\/ajnr.A6373","volume":"41","author":"MI Vargas","year":"2020","unstructured":"Vargas, M. I., Delattre, B. M. A., Vayssiere, P., Corniola, M. & Meling, T. Intraoperative MR and synthetic imaging. Am. J. Neuroradiol. 41, E4\u2013E6 (2020).","journal-title":"Am. J. Neuroradiol."},{"key":"24276_CR22","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.neurad.2019.03.002","volume":"47","author":"KH Ryu","year":"2020","unstructured":"Ryu, K. H. et al. Initial clinical experience of synthetic MRI as a routine neuroimaging protocol in daily practice: A single-center study. J. Neuroradiol. 47, 151\u2013160 (2020).","journal-title":"J. Neuroradiol."},{"key":"24276_CR23","doi-asserted-by":"publisher","first-page":"882","DOI":"10.3174\/ajnr.A6533","volume":"41","author":"T Vanderhasselt","year":"2020","unstructured":"Vanderhasselt, T. et al. Synthetic MRI of preterm infants at term-equivalent age: Evaluation of diagnostic image quality and automated brain volume segmentation. Am. J. Neuroradiol. 41, 882\u2013888 (2020).","journal-title":"Am. J. Neuroradiol."},{"key":"24276_CR24","doi-asserted-by":"publisher","first-page":"783","DOI":"10.3348\/kjr.2018.19.4.783","volume":"19","author":"KM Kang","year":"2018","unstructured":"Kang, K. M. et al. Application of synthetic MRI for direct measurement of magnetic resonance relaxation time and tumor volume at multiple time points after contrast administration: Preliminary results in patients with brain metastasis. Korean J. Radiol. 19, 783 (2018).","journal-title":"Korean J. Radiol."},{"key":"24276_CR25","doi-asserted-by":"publisher","first-page":"e0177135","DOI":"10.1371\/journal.pone.0177135","volume":"12","author":"I Blystad","year":"2017","unstructured":"Blystad, I. et al. Quantitative MRI for analysis of peritumoral edema in malignant gliomas. Plos One 12, e0177135 (2017).","journal-title":"Plos One"},{"key":"24276_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-75105-6","author":"I Blystad","year":"2020","unstructured":"Blystad, I. et al. Quantitative MRI using relaxometry in malignant gliomas detects contrast enhancement in peritumoral oedema. Scientific Reports https:\/\/doi.org\/10.1038\/s41598-020-75105-6 (2020).","journal-title":"Scientific Reports"},{"key":"24276_CR27","doi-asserted-by":"publisher","first-page":"94","DOI":"10.3174\/ajnr.A4501","volume":"37","author":"I Blystad","year":"2016","unstructured":"Blystad, I. et al. Quantitative MRI for analysis of active multiple sclerosis Lesions without Gadolinium-based contrast agent. Am. J. Neuroradiol. 37, 94\u2013100 (2016).","journal-title":"Am. J. Neuroradiol."},{"key":"24276_CR28","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1111\/nan.12432","volume":"44","author":"P Wesseling","year":"2018","unstructured":"Wesseling, P. & Capper, D. WHO 2016 Classification of gliomas. Neuropathol Appl Neurobiol 44, 139\u2013150 (2018).","journal-title":"Neuropathol Appl Neurobiol"},{"key":"24276_CR29","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1002\/mrm.21165","volume":"57","author":"JBM Warntjes","year":"2007","unstructured":"Warntjes, J. B. M., Dahlqvist, O. & Lundberg, P. Novel method for rapid, simultaneousT1, T*2, and proton density quantification. Magn. Reson. Med. 57, 528\u2013537 (2007).","journal-title":"Magn. Reson. Med."},{"key":"24276_CR30","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/S1470-2045(19)30098-1","volume":"20","author":"P Kickingereder","year":"2019","unstructured":"Kickingereder, P. et al. Automated quantitative tumour response assessment of MRI in neuro-oncology with artificial neural networks: A multicentre, retrospective study. Lancet Oncol. 20, 728\u2013740 (2019).","journal-title":"Lancet Oncol."},{"key":"24276_CR31","unstructured":"Isensee, F., J\u00e4ger, P. F., Kohl, S. A. A., Petersen, J. & Maier-Hein, K. H. Automated Design of Deep Learning Methods for Biomedical Image Segmentation. arXiv:1904.08128 [cs] (2020)."},{"key":"24276_CR32","unstructured":"HD-GLIO,https:\/\/github.com\/NeuroAI-HD\/HD-GLIO-AUTO."},{"key":"24276_CR33","unstructured":"SPM12 - Statistical Parametric Mapping. https:\/\/www.fil.ion.ucl.ac.uk\/spm."},{"key":"24276_CR34","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.neuroimage.2005.02.018","volume":"26","author":"J Ashburner","year":"2005","unstructured":"Ashburner, J. & Friston, K. J. Unified segmentation. Neuroimage 26, 839\u2013851 (2005).","journal-title":"Neuroimage"},{"key":"24276_CR35","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.neuroimage.2011.09.015","volume":"62","author":"M Jenkinson","year":"2012","unstructured":"Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W. & Smith, S. M. FSL. NeuroImage 62, 782\u2013790 (2012).","journal-title":"NeuroImage"},{"key":"24276_CR36","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/S1361-8415(01)00036-6","volume":"5","author":"M Jenkinson","year":"2001","unstructured":"Jenkinson, M. & Smith, S. A global optimisation method for robust affine registration of brain images. Med. Image Anal. 5, 143\u2013156 (2001).","journal-title":"Med. Image Anal."},{"key":"24276_CR37","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","volume":"17","author":"M Jenkinson","year":"2002","unstructured":"Jenkinson, M., Bannister, P., Brady, M. & Smith, S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage 17, 825\u2013841 (2002).","journal-title":"Neuroimage"},{"key":"24276_CR38","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1177\/070674370705200210","volume":"52","author":"DL Streiner","year":"2007","unstructured":"Streiner, D. L. & Cairney, J. What\u2019s under the ROC? An introduction to receiver operating characteristics curves. Can. J. Psychiatry 52, 121\u2013128 (2007).","journal-title":"Can. J. Psychiatry"},{"key":"24276_CR39","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3","volume":"3","author":"WJ Youden","year":"1950","unstructured":"Youden, W. J. Index for rating diagnostic tests. Cancer 3, 32\u201335 (1950).","journal-title":"Cancer"},{"key":"24276_CR40","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1016\/j.csda.2010.11.018","volume":"55","author":"A Airola","year":"2011","unstructured":"Airola, A., Pahikkala, T., Waegeman, W., De Baets, B. & Salakoski, T. An experimental comparison of cross-validation techniques for estimating the area under the ROC curve. Comput. Stat. Data Anal. 55, 1828\u20131844 (2011).","journal-title":"Comput. Stat. Data Anal."},{"key":"24276_CR41","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.1016\/j.clineuro.2012.12.031","volume":"115","author":"Z Min","year":"2013","unstructured":"Min, Z., Niu, C., Rana, N., Ji, H. & Zhang, M. Differentiation of pure vasogenic edema and tumor-infiltrated edema in patients with peritumoral edema by analyzing the relationship of axial and radial diffusivities on 3.0T MRI. Clin. Neurol. Neuros. 115, 1366\u20131370 (2013).","journal-title":"Clin. Neurol. Neuros."},{"key":"24276_CR42","first-page":"111","volume":"4","author":"S Safari","year":"2016","unstructured":"Safari, S., Baratloo, A., Elfil, M. & Negida, A. Evidence based emergency medicine; part 5 receiver operating curve and area under the curve. Emergency 4, 111\u2013113 (2016).","journal-title":"Emergency"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-24276-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-24276-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-24276-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T11:09:45Z","timestamp":1671275385000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-24276-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,17]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["24276"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-24276-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,17]]},"assertion":[{"value":"16 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"M.S. declares: speaker fees (paid to institution) from GE Healthcare and AuntMinnie and consultation fees (paid to institution) from Bracco The rest of the authors, L.N.G., D.H.J.P, K.A.G, J.J, A.M.R, J.A.H.T declare no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21820"}}