{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T23:52:55Z","timestamp":1794009175215,"version":"4.8.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T00:00:00Z","timestamp":1671062400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T00:00:00Z","timestamp":1671062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Modified monovision\u2014or \u201cmini-monovision\u201d\u2014is an alternative method to multifocal intraocular lenses (IOLs) for treating presbyopia. This study aimed to evaluate the clinical outcomes of patients bilaterally implanted with the new enhanced monofocal Tecnis Eyhance (ICB00) IOLs with the mini-monovision technique to improve near vision. In this retrospective case series, the medical records of 50 patients (100 eyes) who underwent bilateral cataract surgery were reviewed. Patients were divided into the Emmetropia and Mini-monovision groups based on the postoperative spherical equivalent and residual myopia. The binocular visual acuity for far (4\u00a0m), intermediate (66\u00a0cm), and near (40\u00a0cm) distances, binocular defocus curves, contrast sensitivity, visual symptoms, spectacle independence, and patient satisfaction rates were evaluated at 3\u00a0months postoperatively. The binocular uncorrected distance and intermediate visual acuities, contrast sensitivity, incidence of photic phenomena, and patient satisfaction were not significantly different between the two groups (p\u2009&gt;\u20090.05). However, the binocular uncorrected near visual acuities and spectacle independence rates were significantly better in the Mini-monovision group (p\u2009&lt;\u20090.001). Conclusively, the pseudophakic mini-monovision technique using enhanced monofocal IOLs may be a promising option for presbyopia correction in patients unsuitable for multifocal IOLs.<\/jats:p>","DOI":"10.1038\/s41598-022-26315-7","type":"journal-article","created":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T17:04:04Z","timestamp":1671123844000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Visual outcomes, spectacle independence, and patient satisfaction of pseudophakic mini-monovision using a new monofocal intraocular lens"],"prefix":"10.1038","volume":"12","author":[{"given":"Ella SeoYeon","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyunmin","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung Uk","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ikhyun","family":"Jun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyoung Yul","family":"Seo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eung Kweon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae-im","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,15]]},"reference":[{"key":"26315_CR1","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1097\/ICU.0000000000000340","volume":"28","author":"CM Lee","year":"2017","unstructured":"Lee, C. M. & Afshari, N. A. The global state of cataract blindness. Curr. Opin. Ophthalmol. 28, 98\u2013103 (2017).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"26315_CR2","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/S0140-6736(17)30544-5","volume":"390","author":"Y-C Liu","year":"2017","unstructured":"Liu, Y.-C., Wilkins, M., Kim, T., Malyugin, B. & Mehta, J. S. Cataracts. Lancet 390, 600\u2013612 (2017).","journal-title":"Lancet"},{"key":"26315_CR3","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1097\/00055735-199602000-00005","volume":"7","author":"IH Fine","year":"1996","unstructured":"Fine, I. H. & Hoffman, R. S. Refractive aspects to cataract surgery. Curr. Opin. Ophthalmol. 7, 21\u201325 (1996).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"26315_CR4","first-page":"339","volume":"6","author":"DR Breyer","year":"2017","unstructured":"Breyer, D. R. et al. Multifocal intraocular lenses and extended depth of focus intraocular lenses. Asia-Pac. J. Ophthalmol. 6, 339\u2013349 (2017).","journal-title":"Asia-Pac. J. Ophthalmol."},{"key":"26315_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12886-018-0963-3","volume":"18","author":"DG Goldberg","year":"2018","unstructured":"Goldberg, D. G., Goldberg, M. H., Shah, R., Meagher, J. N. & Ailani, H. Pseudophakic mini-monovision: High patient satisfaction, reduced spectacle dependence, and low cost. BMC Ophthalmol. 18, 1\u20136 (2018).","journal-title":"BMC Ophthalmol."},{"key":"26315_CR6","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1097\/j.jcrs.0000000000000424","volume":"47","author":"O-S Koo","year":"2021","unstructured":"Koo, O.-S., Kang, J.-W., Park, J.-K. & Kim, K.-H. Visual performance and patient satisfaction after implantation of extended range-of-vision IOLs: Bilateral implantation vs 2 different mix-and-match approaches. J. Cataract Refract. Surg. 47, 192\u2013197 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR7","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.ajo.2019.03.019","volume":"208","author":"JQ Hu","year":"2019","unstructured":"Hu, J. Q., Sarkar, R., Sella, R., Murphy, J. D. & Afshari, N. A. Cost-effectiveness analysis of multifocal intraocular lenses compared to monofocal intraocular lenses in cataract surgery. Am. J. Ophthalmol. 208, 305\u2013312 (2019).","journal-title":"Am. J. Ophthalmol."},{"key":"26315_CR8","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.jcrs.2013.12.011","volume":"40","author":"R Braga-Mele","year":"2014","unstructured":"Braga-Mele, R. et al. Multifocal intraocular lenses: relative indications and contraindications for implantation. J. Cataract Refract. Surg. 40, 313\u2013322 (2014).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR9","first-page":"12","volume":"2016","author":"SR de Silva","year":"2016","unstructured":"de Silva, S. R., Evans, J. R., Kirthi, V., Ziaei, M. & Leyland, M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst. Rev. 2016, 12 (2016).","journal-title":"Cochrane Database Syst. Rev."},{"key":"26315_CR10","first-page":"45","volume":"5","author":"B Cochener","year":"2011","unstructured":"Cochener, B., Lafuma, A., Khoshnood, B., Courouve, L. & Berdeaux, G. Comparison of outcomes with multifocal intraocular lenses: A meta-analysis. Clin. Ophthalmol. 5, 45 (2011).","journal-title":"Clin. Ophthalmol."},{"key":"26315_CR11","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0886-3350(00)00540-X","volume":"27","author":"G H\u00e4ring","year":"2001","unstructured":"H\u00e4ring, G., Dick, H. B., Krummenauer, F., Weissmantel, U. & Kr\u00f6ncke, W. Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses: Results of a multicenter questionnaire. J. Cataract Refract. Surg. 27, 245\u2013249 (2001).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR12","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1016\/j.jcrs.2010.10.056","volume":"37","author":"JL Ali\u00f3","year":"2011","unstructured":"Ali\u00f3, J. L. et al. Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal model. J. Cataract Refract. Surg. 37, 638\u2013648 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR13","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","volume":"37","author":"NE de Vries","year":"2011","unstructured":"de Vries, N. E. et al. Dissatisfaction after implantation of multifocal intraocular lenses. J. Cataract Refract. Surg. 37, 859\u2013865 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR14","doi-asserted-by":"publisher","first-page":"664","DOI":"10.3928\/1081597X-20170621-08","volume":"33","author":"MS Attia","year":"2017","unstructured":"Attia, M. S. et al. Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk. J. Refract. Surg. 33, 664\u2013669 (2017).","journal-title":"J. Refract. Surg."},{"key":"26315_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12886-021-02124-w","volume":"21","author":"J Huh","year":"2021","unstructured":"Huh, J. et al. A comparison of clinical outcomes and optical performance between monofocal and new monofocal with enhanced intermediate function intraocular lenses: A case-control study. BMC Ophthalmol. 21, 1\u20139 (2021).","journal-title":"BMC Ophthalmol."},{"key":"26315_CR16","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1016\/S0886-3350(02)01218-X","volume":"28","author":"S Greenbaum","year":"2002","unstructured":"Greenbaum, S. Monovision pseudophakia. J. Cataract Refract. Surg. 28, 1439\u20131443 (2002).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR17","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1080\/08820538.2016.1228400","volume":"32","author":"S Greenstein","year":"2017","unstructured":"Greenstein, S. & Pineda, R. The quest for spectacle independence: A comparison of multifocal intraocular lens implants and pseudophakic monovision for patients with presbyopia. Semin. Ophthalmol. 32, 111\u2013115 (2017).","journal-title":"Semin. Ophthalmol."},{"key":"26315_CR18","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1016\/j.jcrs.2010.12.041","volume":"37","author":"F Zhang","year":"2011","unstructured":"Zhang, F., Sugar, A., Jacobsen, G. & Collins, M. Visual function and spectacle independence after cataract surgery: Bilateral diffractive multifocal intraocular lenses versus monovision pseudophakia. J. Cataract Refract. Surg. 37, 853\u2013858 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR19","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.jcrs.2014.06.015","volume":"41","author":"G Labiris","year":"2015","unstructured":"Labiris, G., Giarmoukakis, A., Patsiamanidi, M., Papadopoulos, Z. & Kozobolis, V. P. Mini-monovision versus multifocal intraocular lens implantation. J. Cataract Refract. Surg. 41, 53\u201357 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR20","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s12009-007-0035-4","volume":"39","author":"M Chen","year":"2007","unstructured":"Chen, M. & Atebara, N. H. A comparison of a monofocal Acrysoft IOL using the \u201cblended monovision\u201d formula with the multifocal array IOL for glasses independence after cataract surgery. Ann. Ophthalmol. 39, 237\u2013240 (2007).","journal-title":"Ann. Ophthalmol."},{"key":"26315_CR21","doi-asserted-by":"publisher","first-page":"2449","DOI":"10.1016\/j.ophtha.2013.07.048","volume":"120","author":"MR Wilkins","year":"2013","unstructured":"Wilkins, M. R. et al. Randomized trial of multifocal intraocular lenses versus monovision after bilateral cataract surgery. Ophthalmology 120, 2449\u20132455 (2013).","journal-title":"Ophthalmology"},{"key":"26315_CR22","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1097\/ICU.0000000000000487","volume":"29","author":"A Mahrous","year":"2018","unstructured":"Mahrous, A., Ciralsky, J. B. & Lai, E. C. Revisiting monovision for presbyopia. Curr. Opin. Ophthalmol. 29, 313\u2013317 (2018).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"26315_CR23","first-page":"95","volume":"50","author":"J Mu","year":"2014","unstructured":"Mu, J., Chen, H. & Li, Y. Comparison study of visual function and patient satisfaction in patients with monovision and patients with bilateral multifocal intraocular lenses. Chin. J. Ophthalmol. 50, 95\u201399 (2014).","journal-title":"Chin. J. Ophthalmol."},{"key":"26315_CR24","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1097\/j.jcrs.0000000000000332","volume":"46","author":"P V\u00e1mosi","year":"2020","unstructured":"V\u00e1mosi, P. & N\u00e9meth, G. Enhanced aspheric optic: The ideal compromise for intermediate visual acuity. J. Cataract Refract. Surg. 46, 1326 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR25","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1177\/1120672121995343","volume":"32","author":"D Lopes","year":"2021","unstructured":"Lopes, D. et al. Comparative evaluation of visual outcomes after bilateral implantation of an advanced or conventional monofocal intraocular lens. Eur. J. Ophthalmol. 32, 229\u2013234 (2021).","journal-title":"Eur. J. Ophthalmol."},{"key":"26315_CR26","first-page":"101511","volume":"26","author":"GU Auffarth","year":"2020","unstructured":"Auffarth, G. U. et al. Clinical evaluation of a new monofocal intraocular lens with enhanced intermediate function in cataract patients. J. Cataract Refract. Surg. 26, 101511 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR27","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000000061","volume":"46","author":"R Mencucci","year":"2020","unstructured":"Mencucci, R., Cennamo, M., Venturi, D., Vignapiano, R. & Favuzza, E. Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: Preliminary results. J. Cataract Refract. Surg. 46, 378\u2013387 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR28","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.jcrs.2012.08.059","volume":"39","author":"G Beiko","year":"2013","unstructured":"Beiko, G. Comparison of visual results with accommodating intraocular lenses versus mini-monovision with a monofocal intraocular lens. J. Cataract Refract. Surg. 39, 48\u201355 (2013).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR29","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1097\/j.jcrs.0000000000000706","volume":"48","author":"E Corbelli","year":"2021","unstructured":"Corbelli, E., Iuliano, L., Bandello, F. & Fasce, F. Comparative analysis of visual outcome with three intraocular lenses: Monofocal, enhanced monofocal, and extended range of vision. J. Cataract Refract. Surg. 48, 67\u201374 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"26315_CR30","doi-asserted-by":"publisher","first-page":"439","DOI":"10.3341\/kjo.2020.0042","volume":"34","author":"M Choi","year":"2020","unstructured":"Choi, M. et al. Visual outcomes after bilateral implantation of an extended depth of focus intraocular lens: A multicenter study. Korean J. Ophthalmol. 34, 439\u2013445 (2020).","journal-title":"Korean J. Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-26315-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-26315-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-26315-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T17:09:02Z","timestamp":1671124142000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-022-26315-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,15]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["26315"],"URL":"https:\/\/doi.org\/10.1038\/s41598-022-26315-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,15]]},"assertion":[{"value":"10 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21716"}}